N632JB
2006 Airbus A320-232 standard FAA →
registration
- 2006
NTSB
- 12 Aug 2016
incident, Wood SD
service difficulty reports
65 reports
- 27 Mar 2026
Air Filter, contaminated
FLT 808 SJU- BOS. AFTER ENG SHUTDOWN FA'S IN THE AFT CABIN COMPLAINED OF A DIRTY SOCKS ODOR AND THE ODOR WAS OBSERVED IN FORWARD CABIN. ODOR IN AFT DISSIPATED…
- 14 Feb 2026
Skin, damaged
DURING HEAVY MAINTENANCE: ELONGATED HOLES AT 2 LOCATION, BOTTOM SKIN EXTERNAL SURFACE OF CUT OUT FUEL TANK AREA BTW RIB 16 TO RIB 17 ON RT WING; REF AEROMAN…
- 14 Feb 2026
Skin, damaged
DURING HEAVY MAINTENANCE: ELONGATED HOLE EXTERNAL SKIN LOWER SURFACE OF CUT OUT FUEL TANK AREA BT W RIB16 TO RIB17 ON RH WING; REF AEROMAN NR 2026-39866 WO…
- 14 Feb 2026
Post, damaged
DURING HEAVY MAINTENANCE: ELONGATED HOLE UPPER AREA VERTICAL MEMBER Y254 AT FRAME 24A ON FWD CARGO BAY, REF AEROMAN NR 2026-39980 WO 2026 25/1. REMOVED AND…
- 14 Feb 2026
Post, damaged
DURING HEAVY MAINTENANCE: ELONGATED HOLE UPPER AREA VERTICAL MEMBER -Y765 AT FRAME 24A ON FWD CARGO BAY, REF AEROMAN NR 2026-39979 WO 2026 25/1 REMOVED AND…
- 14 Feb 2026
Post, damaged
DURING HEAVY MAINTENANCE: ELONGATED HOLE UPPER AREA VERTICAL MEMBER Y765 AT FRAME 24A ON FWD CARGO COMPARTMENT; REF AEROMAN NR 2026-39978 WO 2026 25/1 REMOVED…
- 14 Feb 2026
Post, damaged
DURING HEAVY MAINTENANCE: ELONGATED HOLE UPPER AREA VERTICAL MEMBER -Y254 AT FRAME 24A ON FWD CA RGO BAY REF AEROMAN NR 2026-39977 WO 2026 25/1 REMOVED AND…
- 4 Jan 2025
Unknown, odor
FLT#1015, EWR-PUJ. 'THE INFLIGHT CREW NOTICED A "DIRTY SOCK" SMELL AT TOP OF DESCENT. THEY CALLED ON THE GROUND TO TELL US IT GOT VERY STRONG. APU WAS NOT…
- 4 Jan 2025
Unknown, odor
FLT#2319, EWR-AUA. 'LEVEL 1 ODOR EVENT IN DESCENT. OIL SMELL STARTED AT 10,000 AND DISSIPATED AT 3,000. FLT CREW AND FWD FA SMELLED ODOR, AFT FA SMELLED…
- 23 Dec 2024
Wire, damaged
FLT#1745, JFK-PSE. 'L-1 INOP SEAT EXIT LT + COVER INOP ( EXIT MARKING SIGNS (WITHOUT PASSENGERS) ); REPLACED EMERGENCY EXIT SIGN ASSEMBLY AT DOOR L1 AND…
- 14 Nov 2023
Unknown, unknown
FLT#803, JFK-SJU. 'STRONG FUMES ODOR ON DESCENT- THRUST AT IDLE PACKS ON APU OFF IN FLIGHT DECK AND CABIN BELOW 10,800 FEET; PERFORMED LEVEL B DECONTAMINATION…
- 3 Nov 2023
Unknown, unknown
FLT#182, BNA-FLL. ' DURING DESCENT APPROACHING 10,000 DETECTED A STRONG DIRTY SOCK SMELL TOXIC FUMES ODOR WAS PRESENT UNTIL LANDING AND PERSISTENT. ODOR WAS…
- 11 Oct 2023
Unknown, unknown
FLT#1015, EWR-PUJ. 'DIRTY SOCKS SMELL ON FINAL APP; PERFORMED DECONTAMINATION OF PACK 1 AND 2 IAW AMM 21-00-00-615-803-A. REF ITEM I LG 3634450 (PER INFO…
- 8 Oct 2023
Unknown, unknown
FLT#894, EWR-STI. ' FA'S REPORTED STRONG DIRTY SOCK SMELL ON FINAL STATED REALLY STRONG IN THE AFT C THEN FWD CABIN; COMPLIED WITH INFORMATION NOTICE…
- 29 Apr 2023
Unknown, unknown
FLT#766, GCM-JFK. ' STRONG ODER DURING DESCENT VERY SIMILAR TO PREVIOUS FLT APU WAS MEL'D OUT OF SERVICE, PASSING 8000FT 220 KTS IDLE LASTED UNTIL LANDING…
- 29 Apr 2023
Unknown, unknown
FLT#765, JFK-GCM. 'STRONG DIRTY SOCK SMELL PASSING 8,000FT, 250KTS POWER IDLE, APU NOT ON SMELL REMAINED. AFTER LANDING AND PARKING APU ON AND APU BLEED ON (…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION UPPER SURFACE OF BOTTOM SKIN PANEL NO3 BTW GEAR RIB 5 AND RIB 5A ON LH WING (CPCP RELATED MPD TASK 575167-01); PERFORMED…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATION FR16 RH OPEN FASTENER HOLE H3 DOOR STOP FITTING 7 CRACJ DIRECTION IS 6 & 9 OCLOCK; REMOVED AND REPLACED INTERCOSTAL…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 RH SIDE IN OPEN FASTENER HOLE H2 AT DOOR STOP FITTING 7, CRACK DIRECTION IS 6 O'CLOCK, AT FWD GALLEY…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: ACCOMPLISH DOOR/EMERGENCY EXIT/OVERWING EMERGENCY EXIT HATCH (AFT RH EEH) FRAME/REINFORCE DOOR STRUCTURE MODIFICATION FOR TRACKING…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH SIDE IN OPEN FASTENER HOLE H3 AT DOOR STOP FITTING 7, CRACK DIRECTIONS ARE 12, 2, AND 3 CLOCK, AT…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH SIDE IN OPEN FASTENER HOLE H2 AT DOOR STOP FITTING 7, CRACK DIRECTION IS 3 OCLOCK, AT FWD GALLEY…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: REF JB 534195-01-2-A. CRACK FLOOR STRUCTURE SECTION CONNECTION FR 66 AT LEVEL Y1292 IN PASSENGER CABIN; REF AEROMAN WO 2023-90/1, NR…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: REF A320-52-1145-02-JB. CRACK INDICATIONS WERE FOUND ON THE INSIDE OF THE INNER EMERGENCY EXIT HATCH FRAME SEGMENT )1) AT EMERGENCY…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: REF A320-52-1145-03-JB. CRACK INDICATIONS WERE FOUND ON THE INSIDE OF THE INNER EMERGENCY EXIT HATCH FRAME SEGMENT )1) AT EMERGENCY…
- 21 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: REF A320-52-1145-01-JB. CRACK INDICATIONS WERE FOUND ON THE INSIDE OF THE INNER EMERGENCY EXIT HATCH FRAME SEGMENT )1) AT EMERGENCY…
- 8 Nov 2022
None, none
FLT#841, JFK-SAV. 'DIRTY SOCK SMELL PLUS FUME/ ODOR ON DEPARTURE OUT OF JFK AND VERY STRONG AT 1500 FEET COMING INTO SAV. EXPERIENCED THRU OUT THE CABIN…
- 4 Aug 2022
None, failed
FLT#1463, LAX-CUN. (AIRCRAFT PERFORMED AN AIR TURN ABCK TO LAX) 'DURING CLIMB THROUGH 15000 FEET NOTICEABLE CABIN PRESSURE FLUCTUATION OCCURRED WITH…
- 3 Aug 2022
None, failed
FLT#1463, LAX-SJD. (AIRCRAFT PERFORMED AN AIR TURN ABCK TO LAX) 'DURING CLIMB CABIN PR SYS 1 FAULT LEVELED AT 21000 DUETO STRONG PRESSURE FLUCTUATIONS. THE…
- 16 Mar 2022
Hydraulic Line, leaking
FLT#54, PBI-JFK. (AIRCRAFT DECLARED EMERGENCY). ' LOST "PARTIAL" GREEN HYDRAULIC FLUID WITH ASSOCIATED LO PRESSURE ECAM GEAR EXTENDED NORMALLY; REF LOG PAGE…
- 31 Oct 2021
Window, dirty
FLT 924, STI-BOS (DIVERTED TO FLL). POSSIBLY WINDOW 24F CRACKED; INSPECTED WINDOW AND FOUND THIN GREASE STREAK ON EXTERNAL CABIN WINDOW AT 24F. CLEANED GREASE…
- 16 Aug 2021
A/C Pack, contaminated
FLT# 1944, PBI-EWR. DIRTY SOCK ODOR AT FL360 IN HIGH ALTITUDE PRECIP - PRIMARILY IN COCKPIT - ODOR REPORT FILLED OUT ; PERFORMED PACK 1 ECS DECONTAMINATION…
- 14 Aug 2021
Unknown, odor
FLT 2028, MCO-EWR. INFLIGHT DURING DESCENT SMELLED TRANSIET ODOR SMELL (DIRTY SOCKS) AND ALSO INFLIGHT CREW REPORTED SAME ODOR IN ROW 7 & 8 AREA AFTER LANDING…
- 12 Aug 2021
Battery, faulted
FLT 1134, SJU-MCO. FWD EMERGENCY LT BATTERY FAULTING. R & R THE FWD EMERGENCY LT BATTERY PER AMM 33-51-38, OPS CHK GOOD.
- 19 Dec 2020
Computer, failed
FLT 799, FLL-HAV. RETURNED TO FIELD. F/CTL AIL SERVO FAULT. L AIL BLUE SYSTEM BOXED AMBER ON F/CTL PAGE, REF TSM 27-93-34. R & R NR 1 ELAC, IAW AMM 27-93-34.…
- 1 Sep 2019
Unknown, odor
I (F4) WAS PERFORMING MY SAFETY DEMO, WHEN I WAS DEMONSTRATING THE OXYGEN MASK I NOTICED A STRONG MUSTY, DIRTY SOCK LIKE SMELL AND STARTED TO FEEL SLIGHTLY…
- 30 Apr 2019
Unknown, odor
FLT 2824, MEX-MCO. ON DESCENT AT APPROX 6000 TO SURFACE AT IDLE PWR. STRONG "DIRTY SOCK" SMELL OBSERVED. THROAT AND LUNG IRRITATION NOTED; COMPLIED WITH…
- 15 Jan 2019
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM Y1292 FRAME 69-70 STR LT; REMOVED AND REPLACED FLOORBEAM IAW SRM 51-72-11. WORK…
- 15 Jan 2019
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM -Y1292 FRAME 69-70 STR 23R; REMOVED AND REPLACED FLOORBEAM -Y1292 IAW SRM 51-72-11.…
- 15 Jan 2019
Floorbeam, cracked
DURING HEAVY MAINTENANCE, FWD CABIN FLOORBEAM Y254 FRAME 21-22 STR 23L HAD A CRACK (REF N/R 440541-20262); REF N/R 440541-20262 - REMOVED AND REPLACED FWD…
- 15 Jan 2019
Light, inoperative
DURING HEAVY MAINTENANCE, 15C- EMERGENCY LIGHT ON ISLE INOP; RELAMPED EMERGENCY LIGHT AT 15C IAW AMM CH. 33-51-16. OPS CHECK GOOD.
- 25 Nov 2017
Fan, failed
FLT 182, BNA-FLL. METALLIC ODOR IN CABIN & FLIGHT DECK. NOTICED 1ST FROM PAX IN ROW 8. 1 FA USED O2 AND WAS DIZZY FROM THE EVENT DURING DESCENT; ODOR PRESENT…
- 31 Mar 2017
Slide, failed
RIGHT AFT DOOR SHOWS DISARMED ABOVE 8000 FT. LEVER ALSO WORKS OUT OF FLUSH DETENT. R & R THE R2 DOOR SLIDE IAW AMM 25-62-44. OPS CHECKED OKAY. OPS CHECKED THE…
- 30 Mar 2017
Floor Support, corroded
DURING HEAVY CHECK, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT Y503.2, BETWEEN FRAMES 12 - 16 IN PAX CABIN. R & R THE FLOOR SUPPORT IAW SRM 51-72-11 AND…
- 30 Mar 2017
Support, corroded
DURING A HEAVY CHECK, CORROSION WAS DISCOVERED ON THE LOWER SUPPORT AT FRAME 66 AND STRINGER 23L AT AFT GALLEY AREA PERFORMED PERMANENT REPAIR IAW SRM…
- 30 Mar 2017
Door Sill, corroded
DURING A HEAVY CHECK, CORROSION WAS DISCOVERED ON AFT CARGO DOOR SILL. REPAIRED THE AREA IAW EA 53-0130-17, REV 1 & EC A17 247-01. MAJOR REPAIR.
- 30 Mar 2017
Cover, corroded
DURING A HEAVY CHECK, CORROSION WAS DISCOVERED ON COVER SHEET FRAMES 52A - 56 IN AFT CARGO BAY. REWORKED & EVALUATED COVER SHEET IAW EA 53-0164-17, & EC…
- 30 Mar 2017
Power Supply, inoperative
DURING A HEAVY CHECK, LOW CAPACITY BATTERY EPSU 10WL, 11WL, 12WL, 13WL WERE DISCOVERED IN PASSENGER CABIN. R & R THE BATTERY EPSU 10WL, 11WL, 12WL, 13WL IAW…
- 30 Mar 2017
Power Supply, inoperative
DURING A HEAVY CHECK, LOW CAPACITY BATTERY EPSU 10WL, 11WL, 12WL, 13WL WERE DISCOVERED IN PASSENGER CABIN. R & R THE BATTERY EPSU 10WL, 11WL, 12WL, 13WL IAW…
- 30 Mar 2017
Power Supply, inoperative
DURING A HEAVY CHECK, LOW CAPACITY BATTERY EPSU 10WL, 11WL, 12WL, 13WL WERE DISCOVERED IN PASSENGER CABIN. R & R THE BATTERY EPSU 10WL, 11WL, 12WL, 13WL IAW…
- 30 Mar 2017
Power Supply, inoperative
DURING A HEAVY CHECK, LOW CAPACITY BATTERY EPSU 10WL, 11WL, 12WL, 13WL WERE DISCOVERED IN PASSENGER CABIN. R & R THE BATTERY EPSU 10WL, 11WL, 12WL, 13WL IAW…
- 30 Mar 2017
Box Beam, cracked
DURING HEAVY CHECK, THERE WAS A CRACK INDICATION IN THE BOX BEAM FLANGE LOCATED 1.5 INCHES FWD FROM FRAME 43. PERFORMED A REPAIR IAW EC 53-1251 AND EA…
- 30 Mar 2017
Box Beam, cracked
DURING HEAVY CHECK, THERE WAS A CRACK INDICATION ON THE BOX BEAM FLANGE LOCATED 1.5 INCHES FWD FROM FRAME 43. PERFORMED A REPAIR IAW EC 53-1251, EA 53-0126-17…
- 30 Mar 2017
Pressure Panel, cracked
DURING HEAVY CHECK, THERE WAS A CRACK INDICATION FOUND IN PRESSURE PANEL ATTACHMENT HOLE ON FRAME 36 LOCATED 1.5 INCH INBD FROM BS 1292 AT 12 O`CLOCK.…
- 30 Mar 2017
Pressure Panel, cracked
DURING HEAVY CHECK, THERE WAS A CRACK INDICATION FOUND IN PRESSURE PANEL ATTACHMENT HOLE ON FRAME 36 LOCATED 13.25 INCHES INBD FROM Y1292 AT 12 O`CLOCK.…
- 17 Nov 2014
Battery Pack, no test
DURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHT FAILED THE TEST. R & R BATTERY PACK 13WL AND 12WL IAW AMM 33-51-38. EMERGENCY LIGHT CHECKS GOOD.
- 17 Nov 2014
Battery Pack, no test
DURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHT FAILED THE FUNCTIONAL TEST. R & R BATTERY PACK 13WL AND 12WL IAW AMM 33-51-38. EMERGENCY LIGHT CHECKED GOOD.
- 22 Feb 2014
Lamp, inoperative
DURING HEAVY MAINTENANCE CHECK, PERFORMED A CABIN EMERGENCY LIGHT CHECK. SEVERAL LIGHTS NOT WORKING. TROUBLESHOT AND REPLACED LAMPS INOPERATIVE EMERGENCY…
- 14 Jul 2013
Connector, damaged
DURING MX CHECK, FOUND ROW 25 SEAT EMERGENCY WHITE LIGHT INOPERATIVE. FOUND CONNECTOR PIN LOOSE FROM WIRE. CRIMPED NEW PIN IAW ESPM 20-44-00. OPS CHECKED OK.
- 21 Dec 2012
Safety Valve, failed
FLT 390 MCO-LGA, CREW DECLARED EMERGENCY AND AIRCRAFT DIVERTED TO JFK DUE TO BRAKES HOT ECAM ILLUMINATED. ON TAKEOFF AT ROTATION THE LEFT BRAKES WERE SHOWING…
- 1 Jun 2012
Pressure Switch, failed
FLT 1557 FLL-BOG, AIRCRAFT DIVERTED TO MCO DUE TO G ENGINE 1 PUMP ON ECAM IN CLIMB. FOUND NR 1 ENGINE PRESSURE SWITCH AT FAULT. REMOVED AND REPLACED IAW…
- 4 Feb 2011
Brake Assy, malfunctioned
FLT 462 RSW-BOS, AIR RETURN TO RSW - CREW DECLARED EMERGENCY DUE TO AFTER LIFT-OFF LEFT SIDE BRAKES OVERHEAT FROM 45 DEGS TO OVER 600 DEGS ON INDICATION IN 15…
- 18 Oct 2010
Warning System, malfunctioned
FLT 1784 BOG-MCO, AIR TURNBACK TO BOG DUE TO FLT CONTROL AIL 1 AND 2 FAULT ON ECAM. FLT CONTROL ALT LAW LOST. RESET ELAC 1 C/B B11 AND A01. PERFORMED OPS TEST…
- 10 Aug 2010
Fan, malfunctioned
FLT 809 JFK-SDQ A/C DIVERTED TO MCO, AT CRUISE A MOMENTARY 10 SEC AROMA OF ELECTRICAL FUMES AND DISSIPATED RAPIDLY. CABIN CREW REPORTED AROMA AT ROW 5 AND…
- 22 Nov 2007
Wire, damaged
EMERGENCY LIGHTING A ROW 7 INOP. WIRES PULLED FROM CONNECTOR. ITEM IS (OPEN) PLACED ON MEL 33-50-03, CAT C UNDER CONTROL NUMBER L01907.