N630JB
2005 Airbus A320-232 standard FAA →
registration
- 2005
service difficulty reports
64 reports
- 26 Apr 2026
Unknown, odor
FLT 1145, RIC-FLL. DURING CLIMB (APPROXIMATLEY) PASSING THROUGH 10,OOOFT THREE FLIGHT ATTENDANTS REPORTED A STRONG CHEMICAL ODOR COMING FROM THE FORWARD…
- 21 Apr 2026
Pbe, unraveled
DURING HEAVY MAINTENANCE: COCKPIT PBE FOUND UNRAVELED; REMOVED AND REPLACED PBE AT FIN 5776HM IAW A320 AMM 35-31-52-400-002.
- 21 Apr 2026
Floor Support, corroded
DURING HEAVY MAINTENANCE: EVIDENCE OF CORROSION ON FLOOR BEAM AT -Y1292; REF STS WO W004338 NR N00592 FLOOR BEAM -Y1292 REMOVED AND REPLACED AT FR68 TO FR69…
- 21 Apr 2026
Floor Support, corroded
DURING HEAVY MAINTENANCE: EVIDENCE OF CORROSION ON FLOOR BEAM AT Y1292; REF STS WO W004338 NR N0593 REMOVED & REPLACED FLOOR BEAM AT Y1292 BETWEEN FR68-FR69…
- 9 Jun 2025
Unknown, odor
FLT#1084, MCO-JFK. 'FUME IN COCKPIT DESCENDING BELOW 12K DIRTY SOCK SMELL. NO ODOR IN BACK, FA'S SAID NOTHING; PERFORMED DETAILED VISUAL INSPECTION OF APU,…
- 28 May 2025
Unknown, odor
FLT#1129, PVD-JFK. 'INBOUND FLIGHT ATTENDANTS REPORT ODOR/FUMES IN CABIN; ACCOMPLISHED TSM 05-50-00-810-831-A. ODOR IDENTIFIED AS TYPE 10 REF L/P # 4336570-2…
- 27 May 2025
Coffeemaker, odor
FLT#1520, ATL-JFK. 'FLIGHT ATTENDANTS REPORTED MOMENTARY BURNING SMELL IN AREA AROUND COFFEE POTS. AFT GALLEY; C/W INFO NOTICE 2017-T015 SECTION A. FOUND…
- 27 May 2024
Cabin Air Sys, odor
FLT#2433, DCA-PBI. 'DIRTY SOCK SMELL PROM COCKPIT EYEBALL VENTS PASSING 7000 ON DESCENT TURNED PACK 1 OFF AND IT WENT AWAY; COMPLIED WITH INFORMATION NOTICE…
- 1 May 2024
Apu, contaminated
FLT#813, HPN-FLL. 'CABIN ODOR EVENT; COMPLIED WITH INFO NOTICE 2017-T015J IDENTIFIED ODOR EVENT AS TYPE 1 LVL A. APU FOUND CONTAMINATED WITH OIL. PERFORMED…
- 26 Apr 2024
Apu, contaminated
FLT#469, BOS-FLL. 'STRONG LEVEL 2 DIRTY SOCK. DESCENDING FROM 4K TO 3K ON APPROACH. PILOTS THOUGHT IT SOMEWHAT DISSIPATED. FLIGHT ATTENDANT'S DID NOT; FOUND…
- 17 Apr 2024
Apu, odor
FLT#253, FLL-SJU. ', ODOR FELT ON DECENT. SLIGHT DIRTY SOCK SMELL THROUGH 14000. MUCH MORE AT THE GATE WITH APU BLEED RUNNING; COMPLIED WITH INFO NOTICE…
- 4 Apr 2024
Unknown, odor
FLT#269, BOS-FLL. ' DURING CLIMB OUT OF BOSTON AND DURING DESCENT INTO FT LAUDERDALE, CREW OBSERVED SMELL OF ODOR IN COCKPIT AND CABIN. DURING CRUISE FLIGHT,…
- 19 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: WINGS / LH WING / FIXED LEADING EDGE / CLOSEOUT RIB AT WFX 365.514 / WEAR DAMAGE AND ELONGATED HOLES - PERMANENT REPAIR. (CONSIDERED…
- 19 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: WEAR ON LH WING LEADING EDGE AT WING ROOT UPPER AREA; REF AEROMAN NRC 2023-170674 WO# 2023-3/1 PERFORMED PERMANENT REPAIR IAW…
- 19 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION ON SHEAR TIE AT FR 65 BTW STR 43L AND STR 44L IN AFT CARGO COMPARTMENT; FOUND CORROSION TO BE OUT OF LIMITS PER SRM…
- 19 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CORROSION ON CLEAT BTW STR43L AND STR43R AT FRAME 33 IN FWD CARGO COMPARTMENT; FOUND CORROSION TO BE OUT OF LIMITS PER SRM REMOVED…
- 19 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATION ON LH CONTINUITY FITTING LOCATED ON WINDSHIELD CENTRA L LOWER NODE AT COCKPIT. THE CRACK LENGTH IS 0.240 INCH…
- 19 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FOUND ON THE UPPER INBOARD HOLE AT THE INTERCOSTAL LAYER LOC ATED FRAME 16 LH SIDE AT LEVEL OF DOOR STOP…
- 19 Apr 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: CRACK INDICATIONS FOUND ON LOWER INBOARD HOLE AT THE INTERCOSTAL LAYER LOC ATED FRAME 16 RH SIDE AT LEVEL OF DOOR STOP FITTING Ñ 7.…
- 18 Apr 2022
None, none
FLT#768, PSE-MCO.'DIRTY SOCK SMELL BELOW 3000 APPARENT IN COCKPIT AND NOT IN CABIN TURNED OFF PACK 1 AND SMELL DISSIPATED; ACCOMPLISHED LEVEL B ECS…
- 1 Dec 2021
Smoke Detector, failed
FLT 2110, SDQ-JFK. SMOKE DET FAULT ON ECAM ; UPON INITIAL INSPECTION COULD NOT RUN SYS TEST ON SDCU, SUSPECT SDCU. REMOVED & REPLACED SDCU PER AMM 26-17-34,…
- 1 Dec 2021
Smoke Detector, fault message
FLT 2110, SDQ-JFK. SMOKE DET FAULT ON ECAM ; UPON INITIAL INSPECTION COULD NOT RUN SYS TEST ON SDCU, SUSPECT SDCU. REMOVED & REPLACED SDCU PER AMM 26-17-34,…
- 2 Oct 2021
Warning Message, false activation
FLT # 108, MBJ-EWR. SEC 1 FAULT INFLIGHT ; RESET CB B8. MESSAGE CLEARED AC OK FOR SVC.
- 2 Oct 2021
Computer, failed
FLT # 316, TPA-LGA (DIVERTED TO JFK). SEC 1 FAULT ; R&R SEC 1 PER AMM 27-94-34 OPS CHECK GOOD A/C RETURNED TO SVC MCC NOTIFIED
- 24 Aug 2021
Hinge Fitting, excess play
FLT # 2761, FLL-SXM(AIR TURNBACK TO FLL). EXPERIOENCED A VIBRATION AT FL 250 CLIMBING @ 300KTS. SLOWED SPEED TO 280KTS, ONCE AIRCRAFT ACCELERATES AGAIN TO…
- 30 Jul 2021
Pump, failed
FLT 1122, CUN-BOS. DIVERTED TO BOS. GREEN HYDRAULIC SYSTEM ALL FLUID LOST IN FLIGHT; R & R ENG #1 HYD PRESS SUPPLY LINE, AND HYD EDP) OPS CHK GOOD, NO LEAKS…
- 18 Jul 2021
Power Supply, no test
DURING HMV, INOP EPSU 10WL IN PASSENGER CABIN DURING OPS TEST OF THE EMERGENCY LIGHTS ; REF AEROMAN N/R 2021- 298604, REMOVED AND REPLACED EPSU POSITION 10WL,…
- 18 Jul 2021
Power Supply, no test
DURING HMV, EPSU 13WL IN AFT GALLLEY DOES NOT PASS TEST ; REF AEROMAN N/R 20221- 298537, REMOVED AND REPLACED EPSU 13WL IAW AMM 33-5138-000-001 &…
- 18 Jul 2021
Slide, inadequate
DURING HMV, IMPROPERLY PACKED PASSENGER CREW DOOR L2 (832) SLIDE RAFT ; REF AEROMAN N/R 2021-298526, REMOVED AND REPLACED PASSENGER CREW DOOR L2 ( 832) ESCAPE…
- 18 Jul 2021
Slide, no test
DURING HMV, CREW DOOR L1 (831) SLIDE FAILS OPS TEST OF EMERGENCY LIGHTS ; REF AEROMAN N/R 2021- 298587, REMOVED AND REPLACED ESCAPE SLIDE RAFT CREW DOOR L1…
- 11 Apr 2021
Cabin Air Sys, odor
FLT 1133, MCO-SJU. INFLIGHT REPORTED FUMES FROM MIDDLE TO AFT OF CABIN DURING DESCENT. SLIGHT ODOR IN COCKPIT ON DESCENT. FA STATED FUMES IN REAR OF A/C WAS…
- 2 Apr 2021
Unknown, odor
FLT 1134, SJU-MCO. DIRTY SOCK ODOR/SMELL ON DECENT PACKS ON ENGINES APU OFF SECOND LEG IN A ROW ( APU SYSTEM ); ITEM TRANSFERRED TO MEL 49-10-01. MX4 UPDATED…
- 13 Feb 2021
Unknown, odor
FLT 1570, LAX-CUN. INFLIGHT REPORTED ODOR IN CABIN DURING DESCENT BETWEEN 10,000- 9,000 FT IN CLOUDS WITH ANTI ICE ON; COMPLIED WITH INFORMATION NOTICE…
- 16 Aug 2020
Door Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION ON EMERGENCY EXIT DOOR 833 LOCATED ON FRAME SEGMENT ( 1) (2EA) IN PASSENGER CABIN (6 EA) (CRACK LENGTH: 0.280 INCH…
- 16 Aug 2020
Door Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION ON EMERGENCY EXIT DOOR 843 LOCATED ON FRAME SEGMENT ( 1) 10 INCHES TO AFT UPPER CORNER PASSENGER CABIN (1 EA)…
- 16 Aug 2020
Door Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION ON EMERGENCY EXIT DOOR 844 LOCATED ON FRAME SEGMENT ( 1) (2EA) IN PASSENGER CABIN (3 EA) (CRACK LENGTH: 0.250…
- 4 Mar 2019
Lens, missing
FLT 1692, LIR-JFK. EMERGENCY LIGHTS @ FLOOR IN ROWS 5AC & 15AC MISSING LENSES; INSTALLED NEW LENSES AT 5AC & 15AC. REF AMM 33-51-00. OPS CHECK GOOD.
- 22 Jan 2019
Battery Pack, discharged
FLT 1973, EWR-TPA. EMERGENCY LIGHT FAILS TEST; REMOVED AND REPLACED EMERGENCY BATTERY PACK IAW AMM 33-51-38 OPS CKS GOOD FIN 11WL AND 13WL.
- 22 Jan 2019
Battery Pack, discharged
FLT 1973, EWR-TPA. EMERGENCY LIGHT FAILS TEST; REMOVED AND REPLACED EMERGENCY BATTERY PACK IAW AMM 33-51-38 OPS CKS GOOD FIN 11WL AND 13WL.
- 14 Jun 2018
Wire Harness, damaged
ROW 13C SEAT MOUNTED EMERGENCY LIGHT WAS INOPERATIVE. FOUND THE HARNESS UNDER THE SEAT DAMAGED. R & R THE WIRE HARNESS AND OPS TESTED GOOD IAW AMM 33-51-19.
- 9 Jan 2018
Unknown, odor
ODOR DURING DESCENT BETWEEN 15,000 FEET TO 5,000 FEET. COMPLIED WITH INFORMATION NOTICE 2017-T015B SECTION A. AIRCRAFT IS OK FOR SERVICE.
- 19 Nov 2017
Battery, discharged
FLT 1674, CHS-JFK. EPSU BATTERY EMER RT FAIL MESSAGE DURING EMERGENCY SYS TEST THRU CIDS. R & R OF THE BATTERY OF THE EPSU AT 12WL IAW AMM 33-51-38. SYS AND…
- 5 Oct 2017
Unknown, odor
DIRTY SOCK ODOR IN THE MID CABIN AND AFT, AT GATE. PERFORMED A DETAILED INSPECTION OF THE APU COMPARTMENT AND THE APU PNEUMANTIC SYSTEM, NO INDICATION OF AN…
- 6 Jun 2017
Computer, malfunctioned
DURING FLT AT 34K FT, LOST CAPTAIN`S PFD & ND INFO. FOB, TAT,SAT, ECAM SHOWED THE NR 1 ENG EGT OVER LIMITS, THRUST LEVER 1 BELOW LIMITS. ENG 2 N1 DISCREPANCY,…
- 9 May 2017
Fan, odor
DURING APPROACH AT 2000 FT, SMELLED ELECTRICAL FUMES, NO INDICATIONS IN COCKPIT OR ECAM/INDICATION LIGHTS. ON LANDING STOPPED. ODOR DISAPATED. NR 1 F/A HEARD…
- 9 May 2017
Switch, failed
ALL EMERGENCY LIGHT SYSTEMS ARE ON WITH EMERGENCY EXIT LIGHT SWITCH IN ARM. ATTEMPTED RESET IN ALL POSITIONS BUT STILL INOPERATIVE. R & R EMERGENCY LIGHT…
- 16 Mar 2017
Plate, corroded
DURING HEAVY CHECK MAINTENANCE, THE L2 DOOR AFT WEB PLATE BETWEEN FRAME 69 - 70 WAS SEVERELY CORRODED. REMOVED AND REPLACED WEB PLATE IAW SRM 51-42-11 PARA I.
- 16 Mar 2017
Floorbeam, corroded
DURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON INBD SIDE OF OF THE FLOORBEAM AT Y1292 AT FRAME 15. REMOVED AND REPLACED THE FLOORBEAM.
- 16 Mar 2017
Door Sill, corroded
DURING HEAVY CHECK MAINTENANCE, THERE WAS EVIIDENCE OF CORROSION UNDER DOOR SILL PLATE CENTER SECTION OTBD BETWEEN THRESHOLD AND R2 DOOR SILL. REMOVED…
- 16 Mar 2017
Beam, corroded
DURING HEAVY CHECK MAINTENANCE, DISCOVERED THAT AT R2 DOOR BEAM CORRODED FWD SIDE. Y-1292 BETWEEN FRAMES 65-66. R & R THE BEAM IAW SRM 51-42-11.
- 16 Mar 2017
Beam, corroded
DURING HEAVY CHECK MAINTENANCE, IT WAS DISCOVERED THAT L2 DOOR BEAM HAD CORROSION. R & R THE BEAM IAW SRM 51-42-11.
- 16 Mar 2017
Beam, corroded
DURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT L2 DOOR FRAME 68L SIDE, Y1292. R & R THE BEAM IAW SRM 51-42-11, & 51-72-11.
- 16 Mar 2017
Plate, corroded
DURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON AFT CARGO DOOR THRESHOLD PLATE AREA BETWEEN FRAMES 53 TO 56; REMOVED AND REPLACED THE PLATE IAW…
- 21 Jan 2017
Wire, broken
DURING MAINTENANCE, SEAT 18 EMERGENCY LIGHT INOPERATIVE. FOUND A BROKEN WIRE.; R & R SEAT 18 TERMINAL IAW AMM 33-51-08. OPS CHECKED GOOD IAW AMM 33-51-00.
- 18 Jan 2016
Receiver, failed
FLT 1488, NOTICIED NR 1 VOR RED ON MFD, STARTED SMELLING A FAINT BURNING ODOR, THE CIRCUIT BREAKER TRIPPED MESSAGE APPEARED AND CIRCUIT BREAKER G13 TRIPPED.…
- 30 Oct 2015
Coffeemaker, failed
COFFEMAKER NR 2 IN FWD GALLEY SMELLS LIKE ELECTRICAL WHEN ON; R & R COFFEEMAKER, AMM 25-35-15, CHECK NORMAL.
- 21 Sep 2015
Battery, no test
DURING MAINTENANCE AND PERFORMING TASK CARD A320-33-51-00-710-003, BATTERY CAPACITY FAILED TEST. R & R BATTERY AT 13WL IAW AMM 33-51-38. OPS CHECK GOOD. NO…
- 9 Sep 2015
Battery Pack, inoperative
DURING HEAVY MAINTENANCE, FOUND EMERGENCY LIGHTS FAIL EPSU BATTERY FWD LT. R & R 10WL EPSU BATTERY. OPS CHECK NORMAL REF AMM 33-51-38 PB 401.
- 7 Feb 2014
Fms, failed
AIR RETURN, GROSS NAV ERROR DURING TAKE OFF, NO ECAM. TROUBLESHOT NR 1 FMGC, UNABLE TO DUMP DATA FROM KPBI TO KBOS, EVEN WHEN SWITCHING DATABASES. ATTEMPTED…
- 23 May 2013
Fan, malfunctioned
FLT 485 BOS-LAX, CREW DECLARED AN EMERGENCY AND AIRCRAFT DIVERTED TO MSP. DURING CRUISE THE FLT ATTENDANT NOTIFIED COCKPIT OF AN ODOR IN THE MIDDLE SECTION OF…
- 24 Sep 2012
Probe, failed
FLT 765 MCO-BQN, AIR RETURN TO MCO DUE TO NAV TCAS DISCREPANCY NR 1 CAPT PFD AIRSPEED NOT DISPLAYING LOST DURING TAKEOFF ROLL WOULD NOT RETURN TO NORMAL IN…
- 5 Oct 2011
Light, inoperative
FLT 534 TPA-EWR, ON GROUND MAINTENANCE CHECK FOUND EMERGENCY LIGHTS FAIL "EXT LOAD EMERG L". RELAMPED LEFT EMERGENCY OVERWING AFT LIGHTS IAW AMM 33-51-15. OPS…
- 3 Jun 2010
Line, leaking
FLT 46, DECLARED EMERGENCY AND RETURN TO MCO. AFTER TAKEOFF LANDING GEAR DOORS WOULD NOT RETRACT DUE TO LOSS OF GREEN HYD SYS PRESSURE. AIRCRAFT LANDED…
- 4 Jun 2006
Stator Vane, lack of lube