N625MB
1964 Cessna Wren 182G 460 standard FAA →
registration
- 1964
service difficulty reports
20 reports
- 7 Mar 2002
Battery, discharged
LEAD ACID BATTERY HAS WEAK POWER OUTPUT. VOLTAGE DROPS TO 15-16 VOLTS DURING STARTS AND SHOWS A CONSTANT HIGH RATE OF CHARGE IN-FLIGHT. REPLACED WITH NEW…
- 14 Oct 2001
Bearing, corroded
ANNUALAR BALL BEARING HAS EXCESSIVE PITTING. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 14 Oct 2001
Seal, leaking
NR 3 BEARING SEAL LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 14 Oct 2001
Thermocouple, shorted
THERMOCOUPLE HAS AN INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 14 Oct 2001
Thermocouple, shorted
THERMOCOUPLE HAS AN INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 14 Oct 2001
Bearing, corroded
TURBINE ANNULAR BALL BEARING HAS EXCESSIVE PITTING. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 14 Oct 2001
Seal, leaking
NUMBER 2 BEARING SEAL LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 1 Jul 2001
Bearing, damaged
FOUND EXCESSIVE PITTING ON ANNULAR BALL BEARING. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)
- 21 Apr 2001
Bearing, damaged
FOUND EXCESSIVE PITTING ON CYLINDER ROLLER BEARING NR 2. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)
- 23 Sep 2000
Seal Ring, worn
WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNITS, CORRECTED PROBLEM.
- 23 Sep 2000
Spring, worn
WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 23 Sep 2000
Shroud, damaged
EXCESSIVE GP BLADE TIP RUB. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 23 Sep 2000
Seal, leaking
LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 23 Sep 2000
Seal, leaking
LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 29 Mar 2000
Transducer, inoperative
PRESSURE TRANSDUCER UNIT INOPERATIVE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)
- 9 Aug 1999
Transducer, inoperative
TRANSDUCER INOPER ATIVE. CAUSES NR 2 TORQUE NEEDLE TO READ 20 PERCENT HIGH. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 10 Jun 1999
Transducer, malfunctioned
DURING FLIGHT, TQ READS 20 PERCENT AT ITS HIGHEST POINT. WITH AC MASTER ON, THE TQ INDICATOR SPINS CLOCKWISE 2 TIMES, THEN FLICKERS BELOW ZERO. REPLACED WITH…
- 8 Jan 1999
Cap, cracked
CAP CRACKED BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. THIS PART BEING RETURNED FOR PRODUCT INVESTIGATION.
- 19 Nov 1996
Switch, failed
PRESSURE SWITCH WILL NOT ILLUMINATE AT MINIMUM PRESSURE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 6 Jun 1995
Rotor Assy, blade shift
FAILED SB LT101-72-10-0153. EXCESSIVE IBPT BLADE SHIFT NR 11, MINUS 0.011 INCH. REPLACED WITH NEW UNIT(S) CORRECTED PROBLEM. PART TOTAL CYCLES, 3314.5.