N624US
Dji AGRAS T70P FAA →
registration
earlier registrations
1 past record
- 1979
service difficulty reports
75 reports
- 29 Aug 2009
Power Supply, defective
DURING A MAINTENANCE VISIT, THE EMERGENCY EXIT SIGN JUST AFT OF DOOR 2R WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE POWER SUPPLY TO BE DEFECTIVE AND…
- 16 Aug 2009
Battery Pack, inoperative
DURING AN OVERNIGHT LINE CHECK THE EMERGENCY LIGHT AT DOOR THREE RIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE ASSOCIATED BATTERY PACK TO BE THE…
- 13 Aug 2009
Battery Pack, discharged
DURING A LINE CHECK THE EMERGENCY EXIT SIGN ABOVE DOOR TWO LEFT WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE BATTERY PACK TO BE DEFECTIVE AND REPLACED…
- 28 Jul 2009
Power Supply, inoperative
DURING A MX VISIT THE EMERGENCY EXIT SIGN ABOVE DOOR 3 RT WAS FOUND TO BE INOPERATIVE. MX FOUND THE ASSOCIATED POWER SUPPLY TO BE DEFECTIVE AND REPLACED IT.…
- 14 Jul 2009
Battery Pack, inoperative
DURING AN OVERNIGHT LINE CHECK THE EMERGENCY EXIT SIGN FOR DOOR 2L WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE ASSOCIATED BATTERY PACK TO BE DEFECTIVE…
- 1 Jul 2009
Battery Pack, defective
DURING A MAINTENANCE VISIT THE EMERGENCY ESCAPE PATH LIGHTING IN THE AFT GALLEY WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE ASSOCIATED BATTERY PACK TO…
- 22 May 2009
Battery Pack, inoperative
DURING OVERNIGHT CHECK FOUND EMERGENCY FLOOR LIGHTS IN UPPER DECK INOP. MAINTENANCE REMOVED AND REPLACED BATTERY. OPERATIONAL CHECKED GOOD AND AIRCRAFT WAS…
- 18 May 2009
Power Supply, inoperative
PILOT REPORTED EMERGENCY LIGHTS IN GALLEY 2 ARE INOP. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY MODULE. OPERATIONAL CHECKED GOOD, AND AIRCRAFT WAS…
- 7 Apr 2009
Power Supply, inoperative
DURING OVERNIGHT CHECK, FOUND DOOR 1 RT AFT OVERHEAD CROSS AISLE EMERGENCY EXIT SIGN INOPERATIVE. MX REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK. OPS…
- 7 Apr 2009
Power Supply, inoperative
DURING OVERNIGHT CHECK FOUND, DOOR 1 RT EMERGENCY SIGN OVER DOOR INOPERATIVE. MX REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK. OPS CHECKED GOOD, AND…
- 7 Apr 2009
Power Supply, inoperative
DURING OVERNIGHT CHECK FOUND DOOR 1 RT FWD OVERHEAD CROSS AISLE EMERGENCY SIGN INOPERATIVE. MX REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK. OPS CHECKED…
- 8 Dec 2008
Battery Pack, inoperative
DURING AN OVERNIGHT LINE CHECK THE EMERGENCY EXIT SIGNAGE WOULD NOT ILLUMINATE WHEN TESTED. MX FOUND THE ASSOCIATED BATTERY PACK DEFECTIVE AND REPLACED IT.…
- 7 Nov 2008
Battery Pack, inoperative
DURING OVERNIGHT FOUND EMERGENCY EXIT SIGNS AT DOOR 2 RT INOP. MX R&R BATTERY PACK. OPS CHECKED GOOD AND ACFT WAS RETURNED TO SERVICE.
- 9 Oct 2008
Battery Pack, discharged
DURING OVERNIGHT CHECK, FOUND EMERGENCY LIGHT EXIT SIGN AT 45C, 51C AND ABOVE 4L DOOR INOP. MX R&R BATTERY PACK. OPS CHECKED GOOD AND ACFT WAS RETURNED TO…
- 26 Jul 2008
Battery Pack, inoperative
DURING OVERNIGHT CHECK, FOUND ZONE-E FLOOR EMERGENCY LIGHTS LEFT SIDE INOP. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK. OPERATIONAL…
- 23 May 2008
Shear Tie, cracked
DURING M-CHECK FOUND CRACKS IN FLOOR TO SKIN SHEAR TIE BETWEEN BS 340-360 LT SIDE. REPAIRED PER EA 66-212930.
- 19 May 2008
Power Supply, inoperative
DURING OVERNIGHT CHECK, FOUND MAIN DECK GALLEY EMERGENCY EXIT SIGN WITH ARROWS INOP. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY. OPERATIONAL CHECKED GOOD…
- 19 May 2008
Power Supply, inoperative
DURING OVERNIGHT CHECK, FOUND MAIN DECK DOOR 2 LEFT EXIT SIGN ABOVE DOOR INOP. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY. OPERATIONAL CHECKED GOOD AND…
- 4 May 2008
Battery Pack, inoperative
DURING THE DOD (DEPARTMENT OF DEFENSE) PRE-FLIGHT, FOUND CABIN EMERGENCY LIGHTS AT 3L DOOR INOP. MAINTENANCE REMOVED AND REPLACED BATTERY PACK. OPERATIONAL…
- 17 Nov 2007
Light, inoperative
DURING OVERNIGHT CHECK, EMERGENCY LIGHTS INOP AT DOOR 1L AND 1R. MAINTENANCE REMOVED AND REPLACED BATTERY SUPPLY, LIGHT ASSEMBLY, AND REPAIRED BROKEN WIRES.…
- 16 Nov 2007
Battery Pack, discharged
DURING OVERNIGHT CHECK, FOUND 2 EMERGENCY LIGHTS OUTSIDE OF AIRCRAFT ON LEFT SIDE WING ROOT FAIRING INOP. MAINTENANCE REMOVED AND REPLACED BATTERY PACK.…
- 16 Nov 2007
Battery Pack, discharged
DURING OVERNIGHT CHECK, FOUND EMERGENCY LIGHTS MAIN DECK RIGHT SIDE AISLE EXIT SIGNS IN AISLE JUST FORWARD AND AFT OF DOOR 2R INOP. MAINTENANCE REMOVED AND…
- 28 Aug 2007
Powerpack, inoperative
DURING OVERNIGHT CHECK, "A" ZONE EMERGENCY PATH LIGHTS DO NOT ILLUMINATE AT TEST. MAINTENANCE REMOVED AND REPLACED POWER PACK. OPERATIONAL CHECKED GOOD AND…
- 11 Dec 2006
Battery, inoperative
DURING OVERNIGHT MAINTENANCE, UPPER DECK FLOOR PATH LIGHT WILL NOT TURN ON DURING NIGHT CHECK. MAINTENANCE REMOVED AND REPLACED BATTERY. OPERATIONAL CHECKED…
- 11 Dec 2006
Battery, inoperative
DURING OVERNIGHT MAINTENANCE, B ZONE FLOOR PATH LIGHT WILL NOT RUN ON DURING NIGHT CHECK. MAINTENANCE REMOVED AND REPLACED BATTERY, AND POWER SUPPLY.…
- 1 Dec 2006
Beam, corroded
DURING "L" CHECK FOUND CORROSION ON THE LEFT WING TRAILING EDGE BEAM LOWER CHORD AT WBL 320. ACCOMPLISHED TEMPORARY REPAIR PER SECTION I OF EA 66-207130.…
- 21 Nov 2006
Skin, corroded
DURING "L" CHECK, FOUND CORROSION ON SKIN PANEL 48 AT THE JACKSCREW COMPARTMENT DOOR CUTOUT BS 2412 S47R. REPAIRED PER EA 66-208404.
- 24 Jun 2006
Battery Pack, discharged
EMERGENCY PATH LIGHT IN D-ZONE INOP. REMOVED AND REPLACED BATTERY PACK. OPERATIONAL CHECKED GOOD, AIRCRAFT RETURNED TO SERVICE.
- 24 Jun 2006
Battery Pack, discharged
EMERGENCY PATH LIGHT IN D-ZONE INOP. REMOVED AND REPLACED BATTERY PACK. OPERATIONAL CHECKED GOOD, AIRCRAFT RETURNED TO SERVICE.
- 8 Feb 2006
Power Supply, discharged
DURING LINE CHECK, FOUND ZONE A FLOOR PATH EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY AND BATTERIES. OPERATIONAL CHECK GOOD. A/C RETURNED TO SERVICE.
- 27 Jan 2006
Web, cracked
DURING LINE CHECK FOUND CRACKS IN AFT CARGO ROTARY ACTUATOR SUPPORT WEB AT BS 1900 RBL 110. REPAIRED PER EA 66-204586.
- 28 Oct 2005
Skin, cracked
DURING M-CHECK FOUND CRACK IN SKIN AND BEAR STRAP AT LOWER FORWARD CORNER OF NR 3 RT ENTRY DOOR CUTOUT AREA. REPAIRED PER EA 66-205513.
- 25 Oct 2005
Skin, cracked
DURING M-CHECK FOUND CRACK IN SKIN AND BEAR STRAP AT UPPER AFT CORNER OF NR 3 RT DOOR CUTOUT. REPAIRED PER EA 66-205514.
- 20 Oct 2005
Frame, cracked
DURING "M" CHECK, FOUND CRACKS ON FRAME AT BS 520 BETWEEN S9 AND S11. REPAIRED PER EA 66-205522.
- 20 Oct 2005
Frame, cracked
DURING "M" CHECK, FOUND CRACK ON FRAME AT BS 520 BETWEEN S10 AND S11. REPAIRED PER EA 66-205523.
- 19 Oct 2005
Bulkhead, cracked
DURING "M" CHECK FOUND CRACK IN CANTED BULKHEAD WEB AT BS 260 ST 26L. REPAIRED PER EA 66-205518.
- 18 Oct 2005
Clip, cracked
DURING "M" CHECK, FOUND CRACKS IN INTERCOSTAL ATTACHED SUPPORT CLIP AT BS 340 STR 26L. REPAIRED PER EA 66-205519.
- 18 Oct 2005
Intercostal, cracked
DURING M-CHECK FOUND CRACKS IN INTERCOSTAL ATTACHED SUPPORT CLIP AT BS 340 STR 26L. REPAIRED PER EA 66-205519.
- 18 Oct 2005
Frame, cracked
DURING M-CHECK FOUND CRACK IN FRAME AT BS 240 BETWEEN S13L AND S14L. REPAIRED PER EA 66-205837.
- 16 Oct 2005
Stiffener, cracked
DURING "M" CHECK, FOUND CRACK IN INBOARD STIFFENER OF NR 4 PYLON AT NAC STA 217. REPAIRED PER EA 66-205836.
- 16 Oct 2005
Frame, cracked
DURING "M" CHECK, FOUND CRACK IN FRAME AT BS 2231 S26L. REPAIRED PER EA 66-205517.
- 12 Jan 2005
Engine, bird ingestion
THE CREW ABORTED TAKEOFF AT APPROXIMATELY 100 KTS AFTER SUFFERING A BIRD STRIKE ON THE NR 1 ENGINE. MAINTENANCE INSPECTED THE ENGINE AND FOUND AN UNCONTAINED…
- 14 Nov 2004
Battery, inoperative
DURING LINE CHECK, FOUND ZONE 'D' AND 'E' FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY AND BATTERIES. OPERATIONAL CHECK GOOD.
- 4 Oct 2004
Battery Pack, inoperative
DURING LINE CHECK, FOUND E-ZONE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK AND POWER SUPPLY. OPERATIONAL CHECK GOOD.
- 28 Aug 2004
Electrical Box, odor
BURNING SMELL NOTICED IN AREA BY DOOR 3. SMELL WAS MOST PRONOUNCED IN ROWS 35-39D-G. SEB'S AT THE BOTTOM OF SEATS -E- AND -F- FELT HOT TO TOUCH. TURNED OFF…
- 18 Jun 2004
Battery Pack, inoperative
DURING LINE CHECK, FOUND D-ZONE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK GOOD.
- 12 May 2004
Connector, loose
DURING LINE CHECK, FOUND ZONE E-FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. RESEATED EMERGENCY LIGHT POWER SUPPLY CONNECTOR. OPERATIONAL CHECK GOOD.
- 6 Aug 2003
Floorbeam, cracked
DURING "L" CHECK FOUND CRACKS IN THE FLOORBEAM WEB, UPPER SECTION AND FRAME WEB AT BS 340 LT. THERE WERE CRACKS IN THE FLOORBEAM UPPER SECTION AT BS 340 RT.…
- 1 Mar 2003
Wire, shorted
During takeoff the left wing leading edge overheat light illuminated. Aircraft aborted takeoff at 110 knots resulting in 7 blown tires. Passengers were bussed…
- 25 Oct 2002
service difficulty reports
DURING APPROACH, THE OUTBOARD TRAILING EDGE FLAPS WOULD NOT EXTEND WITH EITHER PRIMARY OR ALTERNATE SYSTEMS. DECLARED A YELLOW EMERGENCY AND FOLLOWED THE COM…
- 5 Jul 2002
Oven, malfunctioned
DURING CLIMB, A BURNING ODOR EMITTED IN ZONE-A, ZONE-B AND UPPER DECK. SHUT OFF UPPER DECK OVENS AND PULLED CIRCUIT BREAKERS AND THE ODOR DISSIPATED. AIRCRAFT…
- 14 May 2002
Odor, detected
DURING DESCENT, A STRONG ELECTRICAL BURNING SMELL EMITTED ABOVE THE NR 1 MAIN DECK GALLEY AND UPPER DECK GALLEY. AIRCRAFT LANDED WITHOUT INCIDENT. VISUALLY…
- 27 Mar 2002
Reservoir
WHILE FLAT FIRING THE DOOR SLIDE ASSEMBLY PRIOR TO OVERHAUL, THE RESERVOIR DELAYED THREE SECONDS AFTER THE MANUAL FIRING LANYARD WAS PULLED. OVERHAULED THE…
- 19 Mar 2002
Sensor, malfunctioned
DURING CRUISE, A BURNING SMELL EMITTED AROUND DOOR 1L. PULLED ESSENTIAL TRANSFORMER RECTIFIER CIRCUIT BREAKER AND DEACTIVATED THE ESSENTIAL TRANSFORMER…
- 8 Mar 2002
Transformer, malfunctioned
DURING DESCENT, A STRONG BURNING SMELL EMITTED IN THE FLIGHT DECK AND BEHIND DOOR 1L FOLLOWED BY A MASTER FIRE WARNING AND BELL. PULLED ESSENTIAL TRANSFORMER…
- 30 Jan 2002
Power Supply, failed
DURING LINE CHECK, FOUND CABIN FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLIES IN ZONES B, C, D, AND E. OPERATIONAL CHECK OK.
- 21 Jan 2002
Skin, cracked
During "H" check found crack on NBR 3 pylon inboard skin lower left side at nacelle station 175. Repaired per EA 66-187314.
- 3 Jan 2002
Floorbeam, cracked
DURING "H" CHECK FOUND CRACK IN UPPER DECK FLOORBEAM AT BS 300 RBL 64. REPAIRED PER EA 66-188018.
- 8 Dec 2001
Battery Pack, discharged
DURING LINE CHECK, FOUND ZONE 'C' AND 'E' FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACKS. OPERATIONAL CHECK GOOD.
- 23 Aug 2001
Connector, disconnected
DURING LINE CHECK, FOUND EMERGENCY ESCAPE PATH LIGHTING IN 'A' ZONE INOPERATIVE. RECONNECTED ELECTRICAL CONNECTORS. OPERATIONAL CHECK NORMAL.
- 6 Dec 2000
Seat Track, corroded
During "L" check found corrosion on upper deck seat track at BS 514 LBL 46. Repaired per EA 66-179481.
- 15 Sep 1999
Pump, leaking
DURING CRUISE, THE NR 4 HYDRAULIC SYSTEM QUANTITY DECREASED. AIRCRAFT DIVERTED TO ANC AND LANDED WITHOUT INCIDENT. REPLACED THE NR 4 ENGINE DRIVEN HYDRAULIC…
- 4 Sep 1999
Valve, malfunctioned
DURING TAKEOFF ROLL, THE NR 1 ENGINE WAS UNABLE TO OBTAIN TAKEOFF EPR WITH THE POWER LEVER AT THE MECHANICAL STOP. THE TAKEOFF WAS ABORTED AT APPROXIMATELY…
- 27 Jun 1998
Compressor, stalled
WHILE CLIMBING THROUGH 1400 FEET AGL, THE NR 4 ENGINE AUDIBLY COMPRESSOR STALLED AND FLAMED OUT. THE CREW SECURED THE ENGINE, DUMPED FUEL, RETURNED TO MSP,…
- 11 Nov 1997
Bleed Valve, failed
DURING CLIMB, THE NR 1 ENGINE FIRE WARNING LIGHT ILLUMINATED. AIRCRAFT RETURNED TO GUM AND LANDED WITHOUT INCIDENT. REPLACED THE NR 1 ENGINE HIGH STAGE BLEED…
- 26 Aug 1997
Compressor, stalled
DURING LANDING ROLLOUT AND WHILE IN REVERSE THRUST, THE NR 3 ENGINE EXPERIENCED A COMPRESSOR STALL. N1 AND N2 DECREASED WHILE EGT ROSE TO 505C. THE ENGINE WAS…
- 6 Jun 1997
Tr Unit, malfunctioned
NR 1 ENGINE THRUST REVERSER WOULD NOT STOW AFTER LANDING. CREW RECYCLED THE NR 1 REVERSER LEVER AND THE ENGINE COMPRESSOR STALLED. EGT PEAKED AT 550C FOR 2 TO…
- 4 Feb 1997
Floorbeam, corroded
DURING PERIODIC CHECK, FOUND CORROSION ON FLOORBEAM AT FS 450 TO 456, RBL 22 TO RBL 32. REPAIRED PER EA 66-121373.
- 4 Feb 1997
Spar Chord, corroded
DURING PERIODIC CHECK, FOUND CORROSION ON CHORD AT FRONT SPAR FS 1501. REPAIRED PER EA 66-121372.
- 15 Jun 1996
Terminal Block, failed
DURING CLIMB, THE RED NOSE LANDING GEAR LIGHT ILLUMINATED AFTER LANDING GEAR RETRACTION. RECYCLED LANDING GEAR AND LIGHT EXTINGUISHED. AIRCRAFT CONTINUED TO…
- 31 Mar 1996
Oil Syst, reqd service
AFTER LANDING IN NRT AND SUBSEQUENT TAXIING, THE NR 1 ENGINE OIL TEMPERATURE INCREASED INTO CAUTION RANGE, THE OIL PRESSURE DECREASED TO CAUTION AS WELL. CREW…
- 15 Sep 1995
Skin, corroded
DURING PERIODIC CHECK, FOUND CORROSION ON THE RIGHT WING LOWER SKIN FORWARD OF THE FRONT SPAR, FS 1309 AT THE LEADING EDGE TENSION ROD FITTING PAD. REPAIRED…
- 14 Sep 1995
Skin, cracked
DURING PERIODIC CHECK, FOUND A PREVIOUS REPAIR CRACKED AND DISBONDING ON THE RIGHT WING INBOARD MIDFLAP LOWER FORWARD PANEL, WBL 210. REPAIRED PANEL (P/N…
- 9 Sep 1995
Fitting, cracked
DURING PERIODIC CHECK, FOUND A CRACK IN THE NR 3 STRUT DIAGONAL BRACE FORWARD ATTACH FITTING. REPLACED FITTING.
- 9 Sep 1995
Skin, cracked
DURING PERIODIC CHECK, FOUND A .25 INCH CRACK IN THE NR 1 PYLON INBOARD SKIN AT NACELLE STATION 175, WATER LINE 151. REPAIRED SKIN PER EA 66-99085.