N618JB
2005 Airbus A320-232 standard FAA →
registration
- 2005
service difficulty reports
59 reports
- 24 Oct 2026
Drive Unit, failed
FLT 1535, FLL-CLO (RETURN TO FIELD). WEATHER RADAR INTERMITTENTLY FAILS SHOWING WXR ANT IN RED; ITEM ALREADY ON DEFFERAL REF MDDR 634190 R+R WXR ANTENNA DRIVE…
- 13 Jul 2026
Apu, odor
FLT 2144, PBI-EWR. DIRTY SOCKS ODOR WITH APU ON. C/W INFO NOTICE 2017-T015M IDENTIFIED AS TYPE 1 APU , ACCOMPLISHED LEVEL A DECONTAMINATION NO ODOR PRESENT AT…
- 3 Jul 2026
Oil System, leaking
FLT # 375, PHL-FLL. INFLIGHT NOTICED DIRTY SOCK ODOR IN CABIN AFTER APU BLEED TURNED ON; COMPLIED WITH I/N 2017-T015-M. INDENTIFIED SOURCE OF ODOR TYPE 1 APU…
- 9 Jun 2026
Unknown, odor
FLT#105, EWR-FLL, REAR FA'S REPORT DIRTY SOCK SMELL AT 2,500 FT ON APPROACH. APU WAS NOT RUNNING. PILOTS DID NOT SMELL ANYTHING. IDENTIFIED ODOR TYPE 1 PER…
- 30 May 2026
Unknown, odor
FLT#1480, FLL-DCA. "ON DESCENT 10,000 TO 6000 FEET STRONG DIRTY SOCK FUME ODOR IN COCKPIT. TURNED OFF PACK 1 AND SMELL DISSAPATED WITHIN 4 MINS; COMPLIED WITH…
- 20 Apr 2026
A/C Pack, odor
FLT#1687, PBI-PVD. PERSISTENT ACRID ODOR IN THE FLIGHT DECK DURING TAKEOFF AND CLIMB UNTIL PACK 1 SELECTED OFF AND ODOR DISSIPATED.
- 28 Jan 2026
A/C Pack, odor
FLT 1691, JFK-LIR. DIRTY SOCK ODOR NOTED DURING DESCENT ON PREVIOUS FLIGHT. FA REPORTED SMELL IN CABIN. UPON ENTERING AIRCRAFT, SMELLED SIMILAR ODOR. ISOLATED…
- 30 Oct 2025
Unknown, odor
FLT#2169, BOS-FLL. "STRONG ODOR AFTER TAKE OFF FIRST FEW ROWS AND FWD GALLEY. OPEN
- 29 Oct 2025
Battery, no test
FLT#391, BOS-TPA. "EMERG LIGHT BATTERY 13WL FAILED TEST; REMOVED AND REPLACED EMERG LIGHT BATTERY FIN 13WL IAW AMM 33-51-38"
- 27 Sep 2025
Hinge Fitting, corroded
DURING HEAVY MAINTENANCE: AFTER REMOVED BEARING CORROSION FOUND ON THE BORE OF HINGE N7 VERTICAL STABILIZER; REF AEROMAN WO 2025 282/1 NR 2025-530866. REMOVED…
- 27 Sep 2025
Skin, dented
DURING HEAVY MAINTENANCE: DENT EXTERNAL SKIN LOCATED BTW FR 79 AND FR 80 AND BTW STRINGER 2LH A ND STRINGER 2RH ON UPPER FUSELAGE; (RESOLVED ON W/O: 1409303…
- 27 Sep 2025
Fitting, cracked
DURING HEAVY MAINTENANCE: CONTINUITY FITTTING CRACKED & RH FWD WINDSHIELD CENTER POST; REF AEROMAN NR 2025-506691 & NR 2025-530843 WO 2025 282/1 FOR WORK…
- 27 Sep 2025
Smoke Warning, false activation
FLT#8650, SAL-FLL. "LAV B SMOKE ECAM SMOKE LAVATORY SMOKE NO SMOKE WAS PRESENT IN LAV B; RESET CIDS 1 & 2 PER A320 AMM 23-93-01 OPS CHECKS OK OF LAV B SMOKE…
- 5 Apr 2025
Flashlight, not reported
DURING HEAVY MAINTENANCE: REF STS WO W003857 NR W003857 N0024 REMOVED AND REPLACED WITH NEW FLASHLIGHT FOR FO IAW A320 AMM 25-65-00-00;
- 8 Mar 2025
Oil System, leaking
FLT#2137, JFK-STI. 'INFLIGHT REPORTS STRONG ODOR ON DECENT; FOLLOWED IFO NOTICED 2017-T015K AND BY DECISION TABLE FILED UP WITH THE MX-270 IT WAS DETERMINED…
- 25 Feb 2025
Engine, failed
FLT#967, HPN-PBI. (AIRCRAFT DIVERTED TO JFK AND DECLARED AN EMERGENCY) 'AT 2000' ENG 2 FAILED FULL A/C VIBRATION FA REPORTS SMELL & SMOKE IN CABIN. RAN ECAM…
- 18 Aug 2023
Unknown, unknown
FLT#2020, FLL-ORH. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) 'SIMILAR TO THE PREVIOUS WRITEUP DURING THE ACCELERATION CLIMB PACKS SOUNDED LIKE THEY WENT…
- 14 Aug 2023
Unknown, unknown
FLT#2260, KIN-JFK. (AIRCRAFT PERFORMED AN AIR TURN BACK TO KIN) ' CLIMBING THRU 12000FT AIRCRAFT EXPERIENCED LARGE INCREASE IN AIR FLOW FROM ENVIRONMENTAL…
- 15 Apr 2023
Unknown, unknown
FLT#1255, FLL-GYE. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) 'AIR ENG BLEED 2 FAULT CAUTION MSG DISPLAYED; FOUND THRM 7170HM2 LEAKING- REPLACED THERMOSTAT…
- 20 Dec 2022
None, none
FLT# 460, FLL-BDL. FO EMERGENCY FLASHLIGHT INOPERATIVE. ACCOMPLISHED AN OPS CHECK OF THE F/O FLASHLIGHT. OPS CHECKED GOOD IAW AMM 25-60-00. NO DEFECTS NOTED.
- 6 Dec 2022
Door Frame, not reported
DURING HEAVY MAINTENANCE, REPLACED SEGMENT EMERGENCY EXIT DOOR IAW NRC 2022-628109, WO 2022-184/1. ACCOMPLISHED EC A320-52-1144 ON EMERGENCY EXIT DOOR FRAME…
- 19 May 2022
Cabin Air Sys, odor
FLT#2303, JFK-SJU. 'INFLIGHT CREW REPORTS ODOR IN AFT CABIN. MX-270 FORM FILLED OUT; COMPLIED WITH INFO NOTICE 2017-T015I SECTION A(A), ISOLATED FAULT TO TYPE…
- 12 Mar 2022
None, none
FLT#1033, MCO-SJU. "DIRTY SOCK SMELL DURING FLT IDLE DESENT CONTINUE FOR REMAINDE OF FLIGHT; COMPLIED WITH INFO. NOTICE 2017-T015 I SECTION A. INSOLATED FAULT…
- 8 Jan 2022
Unknown, odor
FLT # 471, LGA-FLL. "MAGIC MAKER" SMELL IN COCKPIT @ 6000' ON DESCENT- WENT AWAY WITH PACK 1 OFF ; COMPLIED WITH INFO NOTICE 2017-T015I SECTION A. ISOLATED…
- 27 Nov 2021
Battery, failed
FLT 2752, SJU-TPA. EMERGENCY LIGHT BATTERY FIN 12WL FAILED TEST ; REMOVED AND REPLACED EMERGENCY LIGHT BATTERY 12WL IAW AMM 33-51-38
- 14 Sep 2021
Unknown, odor
FLT 787, JFK-SXM. ELECTRICAL SMELL IN CABIN DURING DESCENT BELOW FL 100; PERFORM TSM 24-00-00-810-823A AND 05-50-00-810-831-A. NO DEFECTS OR ABNORMAL SMELL…
- 14 Sep 2021
Unknown, odor
FLT 788, SXM-JFK. INFLIGHT REPORTED SAME "ELECTRICAL SMELL" IN-CABIN DURING DESCENT BELOW 10,000' CORRECTION: INFLIGHT SAID SMELL WAS SIMILAR TO A DIRTY SOCK;…
- 20 May 2021
Slide, obstructed
DURING HEAVY MAINTENANCE, L1 PASS CREW DOOR SLIDE RAFT HITS THE FUSELAGE WHEN DOOR IS FULLY OPEN (REF TO AEROMAN W/O 1109562 REF AEROMAN NON ROUTINE…
- 20 Mar 2020
Floorbeam, corroded
DURING HMV CORROSION ON FLOOR BEAM Y1162.5 BTW FR68 TO FR69 ON AFT GALLEY AREA ; REF: ARM W/O 2020 69/1 N/R 2020-73270 R & R FLOOR BEAM Y1162-5 AND FASTENERS…
- 20 Mar 2020
Floorbeam, corroded
DURING HMV CORROSION ON FLOOR BEAM Y1162.5 BTW FR68 TO FR69 ON AFT GALLEY AREA ; REF: ARM W/O 2020 69/1 N/R 2020-73270. REMOVED AND REPLACED FLOOR BEAM…
- 20 Mar 2020
Floorbeam, corroded
DURING HMV CORROSION ON FLOOR BEAM Y1162.5 BTW FR68 TO FR69 ON AFT GALLEY AREA ; REF: ARM W/O 2020 69/1 N/R 2020-73270. REMOVED AND REPLACED FLOOR BEAM…
- 20 Mar 2020
Floorbeam, corroded
DURING HMV CORROSION ON FLOOR BEAM Y1292 BTW FR66 TO FR68 ON AFT GALLEY AREA ; R & R FLOOR BEAM Y1292 AND FASTENERS LOC BTW FR66 TO FR68 ON AFT GALLEY ARE,…
- 20 Mar 2020
Floorbeam, corroded
DURING HMV CORROSION ON FLOOR BEAM Y1162.5 BTW FR68 TO FR69 ON AFT GALLEY AREA ; R & R FLOOR BEAM Y1162.5 AND FASTENERS LOC BTW FR68 TO FR69 ON AFT GALLEY…
- 20 Mar 2020
Floorbeam, corroded
DURING HMV CORROSION ON FLOOR BEAM Y1292 BTW FR66 TO FR68 ON AFT GALLEY AREA ; R & R FLOORBEAM Y1292 AND FASTENERS LOCATED BETWEEN FR66 TO FR68 ON AFT GALLEY…
- 20 Mar 2020
Skin, corroded
DURING HMV, WING / LH TRAILING EDGE / TOP SKIN OVERHANG RIBS 15-17 / CORROSION / WV 017 UPGRADE - PERMANENT REPAIR ; THIS REPAIR IS CLASSIFIED AS MAJOR. THIS…
- 28 Oct 2019
Connector, loose
FT # 1729, JFK-RSW. EMERGENCY EXIT LIGHT INOP ROW 17 LT SIDE ( FLOOR PROX EMERG ESCAPE PATH MARK SYS - INCANDESCENT LIGHTING SYS - NOT APPLICABLE TO (N703 AND…
- 24 Jun 2019
Battery Pack, no test
FT # 225, EMERGENCY LIGHT BATTERIES 10WL & 13WL FAIL TEST; R & R BATTERIES 10WL & 13WL IAW AMM 33-51-38. OPS CKS OK.
- 24 Jun 2019
Battery Pack, no test
FT # 225, EMERGENCY LIGHT BATTERIES 10WL & 13WL FAIL TEST; R & R BATTERIES 10WL & 13WL IAW AMM 33-51-38. OPS CKS OK.
- 30 Sep 2018
Unknown, odor
FLT 8066, ABQ-JFK. DESCENDING AT A HIGH RATE OF DESCENT THROUGH 10,000 ENCOUNTERED DIRTY SOCK SMELL FROM AC PACKS NO VISIBLE SMOKE ONLY SMELL, NORMAL BLEED…
- 27 Sep 2018
Unknown, odor
FLT 878, LAS-BOS. VERBAL REPORT FROM FLIGHT CREW. DIRTY SOCK SMELL IN CABIN IN DESCENT AT 8000 FT; THIS REPORT DESCRIBES A LEVEL 1 ODOR. COMPLIED WITH…
- 12 Oct 2017
Power Supply, failed
SEAT ROWS 1 AND 5 EMERGENCY LIGHTS INOPERATIVE. R & R EPSU IAW AMM 33-51-38. OPS CHECKED GOOD.
- 3 Feb 2017
Light, inoperative
SEAT 19 ABC EMERGENCY SEAT/AISLE LIGHT WAS INOPERATIVE DURING TEST. R & R SEAT 19 ABC EMERGENCY SEAT/AISLE LIGHT IAW AMM 33-51-19. PERFORMED OPS CHECK. OPS…
- 30 Oct 2016
Dummy Rail, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON THE DUMMY RAIL AT FRAMES 12 - 16 Y520. REMOVED AND REPLACED THE DUMMY RAIL.
- 30 Oct 2016
Cusp Web, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON CUSP WEB AT FRAME 20; REMOVED AND REPLACED IAW SRM 51-42-11.
- 30 Oct 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM Y1292 +2" INBOARD OF L2 DOOR; REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11, 51-42-11,…
- 30 Oct 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM AT Y1292 + 10" INBOARD OF L2 DOOR. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11 & 51-42-11.
- 30 Oct 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM Y1292 FRAME 68 INBOARD OF L2 DOOR. REMOVED AND REPLACED THE FLOORBEAM.
- 2 Jul 2016
Servo Control, failed
DECLARED EMERGENCY, WHEEL N/W STEERING FAULT WHILE IN FLIGHT. RESET N/W STEERING SWITCH TWICE IN FLIGHT AND ONCE ON GROUND, WOULD NOT FUNCTION NORMALLY. R & R…
- 28 Feb 2015
Wire, broken
DURING HEAVY MAINTENANCE CHECK, FOUND WIRES CUT AT LT AFT OVERWING EXIT UNDER SEAT ROW 11L. REMOVED DAMAGED SECTION OF WIRES IAW ESPM 20-33-11 AND REATTACHED…
- 17 Feb 2015
Line, chafed
ENROUTE FLIGHT LEVEL 360 ECAM GREEN HYD LEVEL. GREEN HYD SYSTEM SHOWED 0 FLUID. CREW DECLARED AN EMERGENCY AND LANDED SAFELY. FOUND LT CASE DRAIN GREEN SYSTEM…
- 25 Jun 2014
Light, inoperative
DURING PRE-FLIGHT CHECK, F/A FOUND THE EMERGENCY FLOOR LIGHT ROW 9 RT INOPERATIVE. REPLACED EMERGENCY LENS, RED, COVER. OPS CHECK NORMAL IAW AMM 33-51-11.
- 8 Aug 2013
Light, damaged
CREW REPORTED EMERGENCY LIGHT PANEL INOPERATIVE BELOW SEAT 9D. REPLACED THE SEAT MOUNTED EMERGENCY LIGHT HOUSING IAW AMM 33-51-19. OK FOR SERVICE AS OF THIS…
- 22 Jun 2013
Battery Pack, failed
DURING MX CHECK, FOUND FWD EPSU BATTERY FAILED. REPLACED FWD EPSU BATTERY IAW 33-51-38. OPS CHECKED NORMAL.
- 17 Feb 2012
Power Supply, failed
FLT 981, FLIGHT CREW REPORTED LEFT WING EMERGENCY LIGHT OUT. FOUND EMERGENCY POWER SUPPLY UNIT AT FAULT. REMOVED AND REPLACED IAW 33-51-38. OPS CHECKED GOOD.
- 13 Jul 2010
Unknown, odor
FLT 32 TPA-JFK, AIRCRAFT DIVERTED TO ACY AFTER ENCOUNTERING HOLDING INTO JFK FOR THUNDERSTORMS. UPON DESCENT INTO ACY, CREW STARTED APU INFLIGHT AND RECEIVED…
- 28 Jun 2010
Control Unit, illuminated
FLT 473 BOS-LAX, ENG 1 BLEED FAULT ON ECAM, DURING QRH PROCEDURES ENG 2 PRECOOLER TEMP RISE ABOVE 255 C TRIGGERING AIR ENGINE 2 BLEED FAULT. THIS RESULTED IN…
- 11 Jun 2010
Fan, failed
FLT 132 RSW-JFK ON SHORT FINAL, FAINT ELECTRICAL BURNING SMELL FOLLOWED BY VENT BLOWER FAULT ECAM, SELECTED OVRD, SMELL DISSIPATED. REMOVED AND REPLACED…
- 2 Sep 2006
Odor, detected
ON DESCENT ROW 28 AND AFT INFLIGHT CREW REPORTED BURNING ODOR (ELECTRICAL). ODOR SUBSIDED WHEN LTV SHUT-OFF. LTV REMAINED SHUT-OFF REMAINDER OF FLIGHT.…
- 4 Aug 2005
Display, burned
DURING TAXI OUT FROM GATE, SMOKE WAS COMING OUT OF VDU AT SEAT ROW 7A. RETURNED TO GATE. INITIALLY THE ITEM WAS PLACED ON MEL AND WAS REPLACED ON 8/05/05.