N612JB
2005 Airbus A320-232 standard FAA →
registration
- 2005
service difficulty reports
65 reports
- 17 Oct 2026
Warning Message, illuminated
FLT#773, BOS-AUA-RTF. ON GEAR RETRACTION WE GOT ECAM L/G DOORS NOT CLOSED. ECAM TOLD US TO CYCLE THE GEAR BELOW 220 KTS, WE STILL HAD 1 FLAP AND APP 190 KTS,…
- 8 Apr 2026
Switch, intermittent
FLT#1389, GCM-GCM. "CREW REPORTS EMERGENCY LIGHTS INOP. LIGHTS COME ON AND WILL NOT TURN OFF AFTER ENGINE START ( INTERIOR AND EXTERIOR EMERGENCY LIGHTING…
- 21 Dec 2025
Hydraulic System, warning message
FLT # 2930 SJU- RDU ( AN EMERGENCY WAS DECLEARED ) "LOW ALMOST 0 GREEN RESERV. ECAM HYD G ENG 1 PUMP LO PR G SYS LO PR ECAM AND QRH ACTIONS COMPLETED. FOUND…
- 21 Dec 2025
Reservoir, leaking
FLT #2930 SJU - RDU (AN EMERGENCY WAS DECLARED ) "OW ALMOST 0 GREEN RESERV. ECAM HYD G ENG 1 PUMP LO PR G SYS LO PR ECAM AND QRH ACTIONS COMPLETED.; FOUND RH…
- 28 Aug 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 68 RH SIDE IN OPEN FASTENER HOLE ( INBOARD LOWER HOLE ) AT DOOR STOP FITTING 1 POSITION,CRACK DIRECTION IS…
- 28 Aug 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 68 RH SIDE IN OPEN FASTENER HOLE ( INBOARD LOWER HOLE ) AT DOOR STOP FITTING 4 POSITION,CRACK DIRECTION IS…
- 28 Aug 2025
Skin, damaged
DURING HEAVY MAINTENANCE: LIGHTNING STRIKE EXTERNAL SKIN LOC. BTW FRAME 26 AND FRAME 27 AND BTW STRINGER 41L AND 42L AT LOWER FUSELAGE; WORK ACCOMPLISHED ON…
- 28 Aug 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 68 LH SIDE IN OPEN FASTENER HOLE ( INBOARD LOWER HOLE ) AT DOOR STOP FITTING 1 POSITION, CRACK DIRECTION…
- 28 Aug 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON EMERGENCY EXIT DOOR (843) FRAME SEGMENT (1) (2EA), CRACK LENGTH: 3.50 INCH; ACCOMPLISHED DOORS / EMERGENCY…
- 28 Aug 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON EMERGENCY EXIT DOOR (833) FRAME SEGMENT (1) (2EA), CRACK LENGTH: 2.500 INCH; ACCOMPLISHED DOORS /…
- 28 Aug 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON EMERGENCY EXIT DOOR (834) FRAME SEGMENT (1) (2EA), CRACK LENGTH: 3.100 INCH; ACCOMPLISHED DOORS /…
- 28 Aug 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON EMERGENCY EXIT DOOR (844) FRAME SEGMENT (1) (1EA), CRACK LENGTH: 0.100 INCH; ACCOMPLISHED DOORS /…
- 5 Oct 2024
Unknown, odor
FLT#605, MCO-SDQ. 'ON DESCT <10,000' HAD STRONG ODOR- TURNED OFF PACK 1 AS PER FCOM - SMELL; COMPLIED WITH INFO NOTICE 2017-T015, SECTION B2 IDENTIFIED ODOR…
- 25 Aug 2023
Selector, failed
FLT#2005, BOS-MCO. 'L/G DOORS NOT CLOSED UPON CYCLING L/G DOWN; REMOVED AND REPLACED LANDING GEAR DOORS SELECTOR VALVE (41GA)IAW AMM CH 32-31-34. PERFORMED…
- 22 Jun 2023
Unknown, unknown
FLT#1348, SJU-DCA. 'FOUND R2 DOOR EMERGENCY EXIT SIGN ONE LAMP INOP; RELAMP R2 DOOR CABIN-WALL MOUNTED EMERGENCY -EXIT-MARKERS IN REFERENCE A320 AMM 33-51-13.…
- 23 Dec 2022
Unknown, odor
FLT#98, DEN-JFK. 'DIRTY SOCK SMELL IN DESCENT ALL THE WAY TO LANDING STARTED AT 15000'; PERFORMED LEVEL A DECONTAMINATION OF ECS IAW AMM 21-00-00-615-802A.…
- 10 Dec 2022
A/C Pack, odor
FLT#1295, JFK-AUS. 'STRONG DIRTY SOCK SMELL REPORTED BY INFLIGHT BELOW 4 K ON APPROACH FLYING THROUGH MULTIPLE LAYERS OF CLOUDS AT THE TIME SMELL DISSIPATED…
- 19 Nov 2022
Unknown, odor
FLT#757, DURING DESCENT THRU FL10.0 STRONG DIRTY SOCK ODOR FUMES EVENT STRONG IN THE MID CABIN. ECS DECONTAMINATION ACCOMPLISHED. OZONE FILTERS WERE REPLACED…
- 16 Nov 2022
Cooling Fan, contaminated
FLT # 613, HPN-FLL(DIVERTED TO JFK). FUME EVENT IN CABIN AND COCKPIT DURING CLIMBOUT STAYED AT 12000 DIVERT TO JFK NO OVERWEIGHT LANDING LEVEL 2 TO 3 EVENT…
- 3 Nov 2022
None, none
FLT#2102, FLL-JFK. 'IN-FLIGHT CREW ON INBOUND FLIGHT REPORTED DIRTY SOCK SMELL ON CLIMB AND DESCENT; COMPLIED WITH INFO NOTICE 2017-T015J PERFORMED ENGINE 1 &…
- 2 Oct 2022
None, none
DURING HEAVY MAINTENANCE: CORROSION LOWER SILL AT LEVEL FR68 AND STR 23L AFT GALLEY AREA (CPCP RELATED MPD TASK 534195-01): PERFORMED REPAIR AT LOWER SILL AND…
- 10 Apr 2022
Cabin Air Sys, odor
FLT#350, GND-JFK. 'FAINT ODOR ENROUTE AT CRUISE ALTITUDE A PLASTIC OR ELECTRIC BURN SMELL LASTED APPROX 2 MIN AND QUICKLY DISSIPATED NO ASSOCIATED ISSUES…
- 28 Feb 2022
None, none
FLT # 1505, EWR-FLL. FUME EVENT DESC 8000' UNTIL TOUCHDOWN BOTH COCKPIT & CABIN ; COMPLETED WITH INFORMATION NOTICE 2017-T015, SECTION A (A), ISOLATED FAULT…
- 15 Feb 2022
Computer, failed
FLT # 2029, JFK-RSW. SEC 2 FAULT. ( SPOILER ELEVATOR COMPUTERS - SEC2 (A320 W/O SHARKLETS AND A321'S) ) ; SEC 2 PLACED ON MEL 27-94-01D CAT C. “PULLED AND…
- 15 Feb 2022
Module, failed
FLT # 2029, JFK-RSW. SEC 2 FAULT. ( SPOILER ELEVATOR COMPUTERS - SEC2 (A320 W/O SHARKLETS AND A321'S) ) ; SEC 2 PLACED ON MEL 27-94-01D CAT C. “PULLED AND…
- 15 Feb 2022
Module, failed
FLT # 2029, JFK-RSW. SEC 2 FAULT. ( SPOILER ELEVATOR COMPUTERS - SEC2 (A320 W/O SHARKLETS AND A321'S) ) ; SEC 2 PLACED ON MEL 27-94-01D CAT C. “PULLED AND…
- 5 Jul 2021
Selector Valve, failed
FLT 193, L/G LGCIU 2 FAULT AT GEAR RETRACTION DEPARTING EWR FOR STI DIVERTED TO JFK ;REF L/P 3112277 ITEM # & #2 L/G SELECTOR VALVE 40GA REPLACED IAW AMM…
- 24 Oct 2019
Lamp, burned out
FT # 1348, SJU-DCA. FWD BULKHEAD AT 1ABC RED EMER LIGHT ASSY BURNT OUT; RELAMPED PER AMM 33-51-18. OP CHK GOOD. OK FOR SVC.
- 27 Jan 2019
Unknown, odor
FLT 1151, TPA-SJU. STRONG FUMES DURING DESCENT CABIN NOTICED STRONG FUMES IN AFT AND FRONT OF CABIN ( PACKS - SINGLE (SPEEDBRAKES OK) (N503-N665) ); PERFORMED…
- 1 Aug 2018
Coffeemaker, failed
FAINT ELECTRICAL ODOR IN THE FWD GALLEY DURING CRUISE. PULLED BOTH COFFEE CIRCUIT BREAKERS, THE ODOR WENT AWAY. REMOVED THE NR 1 AND 2 FWD GALLEY COFFEEMAKERS…
- 1 Aug 2018
Coffeemaker, failed
FAINT ELECTRICAL ODOR IN THE FWD GALLEY DURING CRUISE. PULLED BOTH COFFEE CIRCUIT BREAKERS, THE ODOR WENT AWAY. REMOVED THE NR 1 AND 2 FWD GALLEY COFFEEMAKERS…
- 23 Jul 2018
Power Unit, odor
FLT 797, BOS-ATL. 21B POWER BOX HOT AND SMELLS OF ELEC ODOR ( LIVE TV SYS - ENTIRE SYSTEM ); ACCOMPLISHED ELECTRICAL ODOR SYSTEM INTEGRITY CHECK PER LTV-535,…
- 14 Jun 2018
Fan, failed
STRONG BURNING ELECTRICAL ODOR REPORTED NEAR ROWS 1, 2, & 3. ODOR STOPPED AND DISSIPATED QUICKLY. PERFORMED A CABIN ODOR INSPECTION IAW AMM 05-50-810-831-A.…
- 6 Mar 2018
Battery Pack, no test
FWD LEFT EPSU BATTERY 10WL FAILED AN EMERGENCY LIGHT SYS TEST. R & R THE BATTERY PACK IAW AMM 33-51-38, SYSTEM TESTED OK.
- 22 Oct 2017
Engine, overserviced
ON FINAL, AT 2000 FT, THE FA REPORTED A DIRTY SOCK ODOR IN THE FRONT AND AFT CABIN. ODOR DISSIPATED AFTER LANDING. THERE WAS NO ODOR IN THE FLIGHT DECK.…
- 1 Aug 2017
Unknown, odor
DIRTY SOCK ODOR NOTICED DURING DESCENT & APPROCH. NORMAL BLEED OPERATION. CRUISE, AND DESCENT ODOR MORE TOWARD AFT OF CABIN. OPERATED PACKS ON THE GROUND WITH…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 64-67, Y512. R & R FLOOORBEAM FROM FRAME 64-67, Y512 IAW SRM 51-72-11, REV 114 AND…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 67-70 -Y765. R & R FLOORBEAM, FRAME 67-70, Y765. REPLACED IAW SRM 51-72-11, REV 114…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 12-16, Y503.2. R & R FLOORBEAM FRAME 12-24, Y1292 IAW SRM 51-72-11 REV 114 & SRM…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 64-67-Y465. R & R FLOORBEAM, FRAME 64-67-Y465 IAW SRM 51-72-11 REV 114 & SRM…
- 30 Aug 2016
Seat Track, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON SEAT TRACK AT FRAME 64-67-Y765. R & R SEAT TRACK FRAME 64-67-Y765 IAW SRM 51-72-11, REV 114 & SRM…
- 30 Aug 2016
Seat Track, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON SEAT TRACK AT FRAME 12-24-Y1292. R & R SEAT TRACK FRAME 12-24-Y1292 IAW SRM 51-72-11 REV 114 & SRM…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 66-68 -Y1162 THROUGH -Y1292. R & R FLOORBEAM FRAME 66-FRAME 68 BETWEEN -Y1162…
- 30 Aug 2016
Seat Track, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON SEAT TRACK AT FRAME 64-66 -Y1292. R & R SEAT TRACK FRAME 64-68 - Y1292 IAW SRM 51-72-11, REV 114-0,…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 65-67 -Y919. R & R FLOORBEAM 65-67-Y919 IAW SRM 51-72-11, REV 114 SRM 51-42-11, REV…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 68-69 -Y1162. R & R FLOORBEAM FRAME 68-69 -Y1162 IAW SRM 51-72-11 REV 114, SRM…
- 30 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM AT FRAME 68-69 -Y1162. R & R DOG LEG Y1162, FRAME 68-69 IAW SRM 51-72-11 AND SRM 51-42-11,…
- 30 Aug 2016
Shear Plate, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR PLATE, CORRODED FRAME 69-70 LT. R & R SHEAR PLATE IAW SRM 51-72-11 AND 51-42-11 .
- 30 Aug 2016
Shear Plate, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR PLATE FRAME 69-70 RT. R & R SHEER PLATE IAW SRM 51-72-11 AND 51-42-11.
- 30 Aug 2016
Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR PLATE SUPPORT FRAME 69-70 RT. R & R SHEER PLATE SUPPORT BETWEEN FRAME 69-70 RT IAW SRM 51-72-11…
- 30 Aug 2016
Beam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON DOG LEG BEAM BETWEEN Y1162-Y1292, FRAME 66-FRAME 67. DOG LEG BEAM BETWEEN Y1162-Y1292, FRAME 66-67 WAS…
- 9 Feb 2016
Lamp, inoperative
SEAT 1 ABC EMERGENCY LIGHT WILL NOT ILLUMINATE. REPLACED THE LAMP IAW 33-51-19. OPS CHECKED GOOD.
- 6 Nov 2014
Battery Pack, no test
OPS CHECK OF EMERGENCY LIGHTS FAILED. FOUND BATTERY FAULT AT EPSU 11WL, EMERGENCY LEFT, R & R BATTERY AT EPSU 11WL IAW AMM 33-51-38. OPS TEST OF EMERGENCY…
- 29 Aug 2014
Power Supply, failed
DURING MAINTENANCE EPSU UNIT FAILED AFT LT ON EMERGENCY LIGHT TEST. R & R AFT LEFT EPSU IAW AMM 33-51-00. OPS CHECK NORMAL. TEST OK.
- 14 Aug 2014
Seal, leaking
FLT 3, PRECAUTIONARY AIR RETURN TO DEPARTURE FOR NR 1 ENGINE LOW OIL QUANTITY AND HIGH TRENDING OIL CONSUMPTION. INSPECTED NR 1 ENGINE FOR OIL LEAKS, FOUND…
- 28 Mar 2014
Battery Pack, faulted
DURING MAINTENANCE IT WAS DISCOVERED THE EPSU BATTERY FAULTED AT 12WL. ACCOMPLISHED TSM 33-51-00-810-A. R & R EPSU AT FIN 12WL. OPS CHECKED OK.
- 17 Mar 2013
Hydraulic Line, leaking
FLT 746 SJU-MCO, CREW DECLARED EMERGENCY DUE TO HYD G RSVR LO LVL ECAM. FOUND GREEN SYS PRESSURE LINE ON LEFT WING TO FITTING ON MANIFOLD "E" LEAKING. C/W…
- 8 Sep 2012
Power Unit, defective
FLT 852 SJU-BOS, DURING CRUISE, IN-FLIGHT CREW REPORTED A BURNING SMELL ADJACENT TO ROW 23-25. ALL COCKPIT INDICATIONS WERE NORMAL. AS PRECAUTION THE FLIGHT…
- 14 Mar 2012
Cable, failed
FLT 6404, ON GROUND HEAVY MAINTENANCE CHECK FOUND LT CABIN OVERWING EMERGENCY ESCAPE HATCH CABLE FAILED THE TRAVEL TEST (REF JB TASK CARD…
- 14 Mar 2012
Cable, failed
FLT 6404, ON GROUND HEAVY MAINTENANCE CHECK FOUND RT CABIN OVERWING EMERGENCY ESCAPE HATCH CABLE FAILED THE TRAVEL TEST (REF JB TASK CARD…
- 16 Jan 2012
Pressure Sensor, failed
FLT 191 JFK-LAS, AIR RETURN TO JFK DUE TO AT ALTITUDE WITH NR 2 PACK FLOW SELECTED HIGH (DUE PACK 1 MEL) THE PACK FLOW OSCILLATED BETWEEN FULL LOW AND FULL…
- 20 Dec 2011
Servo Control, failed
FLT 842 SJU-BOS, 1.5 HRS INTO FLIGHT AT FL380 ECAM WHEEL N/W STEERING FAULT. AIRCRAFT LANDED IN BOS WITH NO WHEEL STEERING. REMOVED AND REPLACED NOSE WHEEL…
- 13 Jan 2010
Battery, discharged
FLT JB21 JFK-TPA DURING RON MX OPS CHECK OF EMERGENCY LIGHTS, EMERGENCY LIGHT BATTERY TEST FOUND FWD/LT FAULT. REMOVED AND REPLACED FWD/LT EMERGENCY LIGHT…
- 24 May 2006
Fire Detector, malfunctioned
DURING CRUISE FLIGHT THE CREW RECEIVED -APU LOOP A FAULT- AND 2 MINUTES LATER APU FIRE BOTTON ILLUMINATED RED WITH NO ECAM MESSAGE. CREW AFTER 10 SECONDS…
- 13 Feb 2006
Pressure Switch, malfunctioned
OIL CLOG NR 1 ENG IN FLIGHT. REMOVED AND REPLACED NR 1 ENG SCAVENGE OIL FILTER ELEMENT IAW AMM 79-21-44 & ALSO REMOVED AND REPLACED NR 1 ENG SCAVENGE FILTER…