N608JB
2005 Airbus A320-232 standard FAA →
registration
- 2005
service difficulty reports
61 reports
- 23 Mar 2026
Unknown, odor
FLT # 525 PVD-SJU." INFLIGHT REPORTED FUMES EVENT ON DESCENT THROUGH 10,000'.; ACCOMPLISHED INFO NOTICE 2017-T015M, STEPS 1 AND 2 IDENTIFIED AS TYPE 9…
- 21 Sep 2025
Unknown, odor
FLT#1405, MCO-SDQ. "DESCENTING THROUGH 14000FT STRONG SMELL ( ELECTRICAL/ OIL SMELL) ISOLATED SOURCE TO PACK 1 ON THE GROUND..
- 30 Aug 2025
Line, leaking
FLT#1952, MCO-BOS. "FUMES EVENT ON ARRIVAL AT 10,000 FT MUSTY DIRTY SCCK SMELL IN FLIGHT DECK AND FWD CABIN SMELL WENT AWAY WHEN #1 PACK TURNED OFF VIA…
- 27 Aug 2025
Unknown, odor
FLT#699, LGA-MCO. #3&4 INFLIHT CREW REPORTS A VERY STRONG CHEMICAL SMELL IN AFT GALLEY PRODUCING A METALLIC TASTE IN THE MOUTH, SORE THROAT AND HEADACHE…
- 12 Aug 2025
Filter, odor
FLT#562, SJU-BOS. LEVEL 2 ODOR EVENT. DISSIPATED WITH PACK 1 TURNED OFF VIA ODOR CHECKLIST. DIRTY SOCK/ BURNT CRAYON; REMOVED AND REPLACED LH OZONE FILTER IAW…
- 9 Aug 2025
Window Frame, cracked
DURING HEAVY MAINTENANCE: WINDSHIELD FRAME CENTER POST LOWER NODE AREA CRACKED. POST REPAIR INSPECTIONS OF THE MIRROR FITTINGS (TBD) AEROMAN EA 53-0371-22…
- 9 Aug 2025
Window Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON WINDSHIELD CENTER LOWER POST ON UPPER TENSION BOLT AREA ON LH SIDE CRACK LENGTH = 0.250 INCH APPROX;…
- 9 Aug 2025
Fitting, not reported
DURING HEAVY MAINTENANCE: REPLACE THE CONTINUITY FITTINGS IAW EA #53-0053-25 PART# 3 AND 4 ; REF AEROMAN WO# 2025-190/1 WCC# 2025-416752 FOR WORK PERFORMED.…
- 6 Mar 2025
Unknown, odor
FLT#613, HPN-FLL. DURING DESCENT ODOR OBSERVED IN FLIGHT DECK AND CABIN DIRTY SOCK/ HOT PLASTIC MX-270 FILLED OUT; COMPLIED WITH INFO. NOTICE 2017-T015 ,…
- 26 Jan 2025
Unknown, odor
FLT#1145, RIC-FLL. 'FA REPORTS BURNING SMELL DURING LAST 10 MINUTES OF FLIGHT IN AFT GALLEY; VISUAL CHECK OF AFT GALLEY AND BOTH LAV'S, NO EVIDENCE OF…
- 20 Jan 2025
Actuator, faulted
FLT#704, RSW-BDL. (AIRCRAFT DIVERTED TO MCO). 'NOSE GEAR DID NOT RETRACT PROPERLY AFTER TAKEOFF. NOSE GEAR UNLOCKED ECAM PERFORMED GEAR EXTENDED NORMAL…
- 30 Dec 2024
Unknown, odor
FLT#1098, MCO-LGA. 'FA'S REPORT CLIMBING OUT OF MCO DIRTY SOCK SMELL. THE SMELL DISSIPATED + RETURN HEAVY AGAIN ON DESCENT INTO LGA. THE SMELL WAS NOTICED…
- 27 May 2024
Compressor, stalled
FLT#1537, JFK-STI. (AIRCRAFT DIVERTED TO BOS AND DECLARED AN EMERGENCY) ' ON CLIMB THROUGH 14000 FT ABOUT 6 LARGE THUMPS NOISES, VIBRATION, YAWING FOLLOWED BY…
- 14 Jun 2023
Unknown, unknown
FLT#1936, STI-JFK. 'IN DESCENT AND APPROACH BELOW 10000, WE NOTICED A MUSTY SMELL LIKE CRAYONS. IN THE FLIGHT DECK. ODOR WAS ONLY APPARENT IN THE FLIGHT DECK.…
- 16 Jan 2023
Unknown, fumes
FLT#22, MBJ-MCO.' HAD A LEVEL 2 FUMES IN CLIMB OUT. TURNED OFF PACK 2 AND THE FUMES SEEMED TO DISSIPATE; INTEROGATED PILOT SURVEY. ALL POINTS TOWARDS DEICE…
- 1 Sep 2022
None, none
DURING HEAVY MAINTENANCE: CRACK INDICATION FRAME SEGMENT 1 AT OVERWING EMERGENCY EXIT DOOR (AFT RH EEH DOOR 844) CRACK L=0. 197 INCH APPROX; REF AEROMAN N/R…
- 1 Sep 2022
None, none
DURING HEAVY MAINTENANCE: CRACK INDICATIONS WERE FRAME SEGMENTS 1 AT THE OVERWING EMERGENCY EXIT DOOR (FWD RH EEH DOOR 843) CRACK L=0.194 INCH APPROX; REF…
- 1 Sep 2022
None, none
DURING HEAVY MAINTENANCE: CRACK INDICATION FRAME SEGMENT 1 AT THE OVERWING EMERGENCY EXIT DOOR (FWD LH EEH DOOR 833) CRACK L=0.196 INCH APPROX; REF AEROMAN…
- 1 Sep 2022
None, none
DURING HEAVY MAINTENANCE: CRACK INDICATION FRAME SEGMENT 1 AT OVERWING EMERGENCY EXIT DOOR (AFT LH EEH DOOR 834) CRACK L=0.250 INCH APPROX; ACCOMPLISHED EC#…
- 1 Sep 2022
None, none
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE ATTACHMENT AREA CONTINUITY FITTING, RH SIDE, CRACK LENGTH IS 0.200…
- 1 Sep 2022
None, none
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE ATTACHMENT AREA CONTINUITY FITTING, LH SIDE, CRACK LENGTH IS 0.200…
- 27 Jun 2022
None, none
FLT#173, FLL-PUJ. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) 'AT 8500 FEET AVIONICS DOOR SHOWED UNSAFELY. WE JUST HAD WORK ACCOMPLISHED ON AVIONICS. OUT OF…
- 3 Nov 2021
Battery, no test
FLT 2424, MCO-DCA. BATTERY ENERGENCY LIGHT 12WL FAILED CAPACITY TEST ; REMOVED AND REPLACED EMERGENCY LT BATTERY AT RH CENTER CABIN IAW AMM 33-51-38, OPS…
- 29 Jun 2021
Battery, inoperative
FLT 959, BDL-FLL. FO'S EMERGENCY FLASHLIGHT NOT CHARGING ; REPLACED FO'S EMERGENCY FLASHLIGHT BATTERY AS REQUIRED, OPS NORMAL.
- 31 Jan 2020
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM -Y1162.5 LOCATED FR 68-FR69 RH SIDE AT AFT GALLEY AREA; REF AEROMAN NR 2019 398172 WO 2019 341/1 R & R FLOOR…
- 31 Jan 2020
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM -Y1292 FR 66-68 RH SIDE AFT GALLEY; REF AEROMAN NR 2019-398171 WO 2019 341/1 R & R FLOOR BEAM -Y1292 FR66-68 RH…
- 31 Jan 2020
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM - Y 1292 LOCATED FR 66-FR68 RH SIDE AT AFT GALLEY AREA; REF AEROMAN NR 2019 398171 WO 2019 341/1 R& R FLOOR…
- 31 Jan 2020
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM -Y1292 FR 66-68 RH SIDE AFT GALLEY; (REF AEROMAN NR 2019-398171 WO 2019 341/1) R & R FLOOR BEAM -Y1292 FR66-68…
- 31 Jan 2020
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM +N Y 1162 FR 68-FR69 LH SIDE AFT GALLEY; (REF AEROMAN NR 2019-398173 WO 2019 341/1) R & R FLOOR BEAM Y 1162.5…
- 31 Jan 2020
Dampener, corroded
DURING HEAVY MAINTENANCE, CORROSION CREW DOOR 831 DOOR DAMPNER; (REF AEROMAN NR 2019-398006 WO 2019 341/1) R & R DOOR DAMPNER & EMERGENCY OPERATION CYLINDER…
- 31 Jan 2020
Slide, mismanufactured
DURING HEAVY MAINTENANCE, IMPROPERLY PACKED SLIDE DOOR 831; (REF AEROMAN NR 2019 398007 WO 2019 341/1) R & R SERVICEABLE ESCAPE SLIDE DOOR 831 IAW AMM…
- 31 Jan 2020
Skin, corroded
DURING HEAVY MAINTENANCE, WV UPGRADE RH WING CORROSION TOP SKIN LOWER SURFACE TE RIB 13 EC A 17-790-19; (REF AEROMAN NR 2019-398193 WO 2019 341/1 JB EC…
- 31 Jan 2020
Slide, no test
DURING HEAVY MAINTENANCE, PER AEROMAN W/O 2019-341/1 WCC 2019-398297, THE SLIDE RAFT ON DOOR 841 DID NOT PASS OPERATIONAL TEST DURING INSTALLATION PROCEDURE.…
- 31 Jan 2020
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM + Y1162.5 LOCATED FR 68-69 LH SIDE AFT GALLEY; (REF AEROMAN NR 2019 398173 WO 2019 341/1) R & R NEW FLOOR BEAM…
- 24 Oct 2018
Light, malfunctioned
FLT 993, BOS-DEN. UPON PREFLIGHT EXIT ROW LIGHT 10DEF REMAINS ON - END; RESET AND OPS CHECK OF EMER LIGHT SYS OK IAW AMM 33-50-00.
- 23 Apr 2018
Slide, not reported
DURING HEAVY MAINTENANCE, L1 DOOR SLIDE PRESSURE; REMOVED AND REPLACED L1 DOOR SLIDE IAW A320-AMM 25-62-44-000-012-A & 25-62-44-400-007-A.
- 23 Apr 2018
Epsu, no test
DURING HEAVY MAINTENANCE, THE LEFT EPSU FAILED SELF TEST. REMOVED AND REPLACED EPSU IAW AMM 33-51-36-000-001, & 33-51-36-420-050-A. OPS CHECKED GOOD IAW AMM…
- 22 Oct 2017
Landing Gear, malfunctioned
LANDING GEAR LGCIU 2 FAULT ECAM DURING DESCENT. FOLLOWED QRH FOR BOTH LGCIU’S AT FAULT AND PERFORMED THE LG GRAVITY EXTENSION. UNDER THIS CONDITION THE…
- 2 Sep 2017
Unknown, odor
DURING FINAL APPROACH, CAPTAIN AND FIRST OFFICER EXPERIENCED A SLIGHT BURNING ODOR FROM APPARENT AIR CONTAMINATION; RAN ENVIRONMENTAL SYSTEM ISOLATED PACKS NO…
- 15 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOOR SUPPORT -Y1292, 8 INCHES AFT OF FRAME 64. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 15 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOOR SUPPORT -Y1292, 10 INCHES AFT OF FRAME 66. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 15 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOOR SUPPORT -Y1292, 5 INCHES AFT OF FRAME 68. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 15 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM -Y765 AT FRAME 66. REMOVED AND REPLACED FLOORBEAM.
- 15 Aug 2016
Dummy Rail, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON DUMMY RAIL AT NUT PLATE FRAME 16 -Y254. REMOVED AND REPLACED THE DUMMY RAIL.
- 15 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON THE FLOORBEAM FRAME 20, Y1292. REMOVED AND REPLACED THE FLOORBEAM.
- 15 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON THE FLOORBEAM Y1292 AT FRAME 67. REMOVED AND REPLACED THE FLOORBEAM.
- 15 Aug 2016
Door Sill, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON L2 PAX DOOR CUT OUT DOOR SILL GIRT BAR FITTING, FRAME 68. REMOVED AND REPLACED SILL.
- 15 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON THE FLOORBEAM - Y765, DIRECTLY ABOVE FRAME 68. REMOVED AND REPLACED FLOORBEAM.
- 15 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM Y 1292 AT FRAME 68. REMOVED AND REPLACED THE FLOORBEAM.
- 15 Aug 2016
Door Sill, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON L2 DOOR MID SHAPE SILL AT FRAME 67. REMOVED AND REPLACED THE SILL.
- 15 Aug 2016
Floorbeam, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM -Y1732 AT FRAME 66. REMOVED AND REPLACED THE FLOORBEAM.
- 28 May 2015
Computer, failed
UNCOMMANDED PITCH DURING ROTATION. R & R ELAC NR 1 AND ELAC NR 2.
- 28 May 2015
Computer, failed
UNCOMMANDED PITCH DURING ROTATION. R & R ELAC NR 1 AND ELAC NR 2.
- 9 Aug 2014
Landing Gear, malfunctioned
CREW DECLARED AN EMERGENCY, DUE TO LANDING GEAR DID NOT COME UP DOWN & LOCK ON INITIAL EXTENSION. RECEIVED AN ECAM WARNING DURING DESCENT ON FINAL APPROACH.…
- 24 Mar 2013
Coffeemaker, malfunctioned
FLT 545 EWR-PBI, CREW REPORTED COFFEEMAKER NR 2 PRODUCED SOME SMOKE WHILE BREWING. COFFEEMAKER WAS TURNED OFF. REMOVED AND REPLACED FWD GALLEY NR 2…
- 18 Nov 2012
Battery, discharged
FLT 447 BOS-TPA, ON GROUND MAINTENANCE CHECK FOUND EMERGENCY LIGHT FWD BATTERY FAIL. REMOVED AND REPLACED FORWARD EMERGENCY BATTERY IAW AMM 33-51-00.…
- 3 Apr 2011
Unknown, malfunctioned
FLT 177 JFK-PHX, CREW DECLARED EMERGENCY AND AIRCRAFT RETURN BACK TO JFK DUE TO GPS PRIMARY LOST AND LOW ACCURACY INDICATED ON ND 1. MCDU HEADING INFORMATION…
- 7 Oct 2009
Clamp, worn
FLT 304 IAD-BOS - CREW REPORTED WHILE CLIMBING THROUGH FL240 BOTH CABIN AND FLIGHT DECK CREW FELT SEVERE VIBRATIONS THROUGHOUT AIRCRAFT. AIRCRAFT DIVERTED TO…
- 12 Jan 2008
Unknown, odor
FLT 576, MCO-SWF, AT APPROX 15:00Z, F/A REPORTED STRONG BURNING RUBBER ODOR IN REAR OF A/C AND LAST TEN ROWS. RAN AIR COND SYS AND UNABLE TO DUPLICATE ODOR OF…
- 1 Jan 2008
Power Supply, discharged
REAR EMERGENCY LIGHTS INOP. REMOVED AND REPLACED AFT CABIN EPSU POWER SUPPLY (13WL) PER AMM 33-51-38-04. OPS CHECKS OK.
- 26 Oct 2006
Power Supply, discharged
EMERGENCY LIGHT IN AFT CABIN WOULD NOT OPERATE. REPLACED POWER SUPPLY UNIT IN AFT CABIN OVERHEAD CEILING & BATTERY PER AMM 33-51-38. OPS CHECK OK.