N607JB
2005 Airbus A320-232 standard FAA →
registration
- 2005
service difficulty reports
66 reports
- 1 Apr 2025
None, none
FLT#2637, JFK-STI. 'WE ENCOUNTERED SEVERE TURBULENCE ON DEPARTURE LASTING 2 - 3 MINUTES CLEAN CONFIGURATION AND BETWEEN 5000-9000 FEET NO ADVERSER EFFECTED…
- 10 Mar 2025
Frame, cracked
DURING HEAVY MAINTENANCE: REF AEROMAN WO# 2025 17/1 NR# 2025-120246. CRACK INDICATION ON FRAME (1 EA) (CRACK INDICATION ON OPEN HOLE 8 FR20LH JOGGLE AREA.…
- 10 Mar 2025
Lug, cracked
DURING HEAVY MAINTENANCE: REF AEROMAN WO# 2025 17/1 NR# 2025-120296. CRACK ON LUG O/B ACTUATOR ON RH HORIZONTAL STABILIZER, (RESOLVED ON W/O: 1353259…
- 10 Mar 2025
Frame, cracked
DURING HEAVY MAINTENANCE: REF AEROMAN WO# 2025 17/1 NR# 2025-120245. CRACK INDICATION ON OPEN HOLE 6 FR20LH JOGGLE AREA. CRACK DEPTH 0.100 INCH, CRACK…
- 26 Oct 2024
Elec Connector, disconnected
FLT#391, BOS-TPA. 'EMERGENCY LIGHT AT 1L DOES NOT COME ON FOR LANDING; FOUND CANNON PLUG DISCONNECTED. RECONNECTED PLUG PER AMM 33-51-17. OPS OK.'
- 13 Aug 2024
Unknown, fumes
FLT#1889, EWR-SJU. 'STRONG FUMES IN COCKPIT & CABIN. AFTER STARTING ENG 2 AND TURNING ON ENG 2 BLEED; C/W INFO NOTICE 2017-T015(K), DECONTAMINATION LEVEL (B)…
- 16 Jun 2024
Servo Control, failed
FLT#2448, SDQ-FLL. (AIRCRAFT DECLARED AN EMERGENCY). ' FLT CTL AIL SERVO FAULT; REMOVED AND REPLACED R/H INBD AIL SERVO CONTROL PER AMM 27-14-51. SEE LP…
- 8 Apr 2024
Actuator, failed
FLT#583, JFK-MCO. 'PER THE INBOUND FLIGHT CREW LANDING GEAR DID NOT RETRACT; REMOVED AND REPLACED R/H MLG LOCKSTAY ACTUATING CYLINDER IAW AMM 32-11-21. OPS…
- 1 Jul 2022
None, none
FLT#1692, LIR-JFK. (AIRCRAFT DECLARED AN EMERGENCY ) 'HYD GREEN RSVR LOW-LEVEL ECAM IN FLIGHT PERFORMED ECAM AND QRH PROCEDURES HEARD VIBS NOISE; REF LOG PAGE…
- 27 Jan 2022
Unknown, odor
FLT # 603, EWR-SDQ. FUMES EVENT PASSING THROUGH 4000' ENTIRE CREW EXPERIENCED HEADACHE BURNING EYES THROAT ETC; COMPLIED WITH INFO NOTICE 2017-T015, SECTION A…
- 21 Dec 2021
Battery, failed
FLT 604, AUS-JFK. FWD EPSU BATTERY REQ'D REPLACEMENT ; R/R FWD EPSU BATTERY IAW AMM 33-51-00, OPS CHECK GOOD
- 21 Dec 2021
Battery, failed
FLT 604, AUS-JFK. MID LH EPSU BAT REQ'D REPLACEMENT ; R/R MID LH EPSU BATTERY IAW AMM 33-51-00, OPS CHECK GOOD.
- 21 Dec 2021
Battery, failed insp
FLT 694, AUS-JFK. MID RH EPSU BAT REQ'D REPLACEMENT ; R/R MID RH EPSU BATTERY IAW AMM 33-51-00, OPS CHECK GOOD.
- 29 Sep 2021
Ecs, odor
FLT # 1460, FLL-BDL. STRONG "DIRTY SOCK: ODOR/FUMES WHILE DECENDING THROUGH 4000 FEET TO TOUCHDOWN FORM MX 270 COMPLETED ( PACKS ) ; REF TSI 451093 FOR…
- 17 Sep 2021
Unknown, odor
FLT 667, HPN-PBI. DESCENDING THRU 20,000 FT, AFTER SOME LIGHT TO HEAVY RAIN STRONG MAGIC MARKER / NEW SHOW SMELL DOWN TO 1 K. CHECKED W / FA'S NO ODOR / FUMES…
- 9 Sep 2021
Display, failed
FLT 852, CUN-CHS. EIS DMA #2 FAILED TWICE ON RETURN FLIGHT. STAYED FAILED AFTER 2ND TIME ; REMOVED AND REPLACED #1 DMC IAW AMM 31-63-34 OPS CK GOOD. OK FOR…
- 9 Sep 2021
Display, failed
FLT 852, CUN-CHS. EIS DMC #1 FAILED OPERATED ON #3 ONLY WITH CAPT EIS DMC 1 IN INVALID DTAT "MODE" ; REMOVED AND REPLACED #2 DMC IAWAMM 31-64-34 OPS CHECK…
- 18 Dec 2020
Electrical Box, failed
FLT 1532, CTG-JFK. DIVERTED TO FLL. EMERGENCY DECLARED. BURNING ELECTRICAL ODOR REPORTED BY ALL INFLIGHT, DIVERT TO FLL/ROWS 17-22, BETWEEN ROWS 17-22. NO…
- 30 Jan 2020
Battery, no test
FT # 391, BOS-TPA. EMERGENCY LIGHT TEST FAILED; REMOVED & REPLACED EMERGENCY LIGHT BATTERY AT FIN# 11WL IAW AMM 33-51-38.
- 20 Dec 2019
Unknown, odor
DIRTY SOCK ODOR DURING DESCENT THROUGH PRECIP 10,000 FT, COULD NOT ISOLATE EITHER PACK TO DETERMINATE SOURCE, NUMEROUS PAX NOTICED. COMPLIED WITH INFORMATION…
- 2 Sep 2019
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION UPPER SURFACE LOCATED POINT N1 RIB 4 +9 POINT 2 RIB 4 +15 STR 11 RT WING. PERFORMED PERMANENT REPAIR ON LOC UPPER SURFACE…
- 2 Sep 2019
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON UPPER SURFACE RIB9 +18 STR 11 RT WING. PERFORMED PERMANENT REPAIR ON UPPER SURFACE RIB 9+8 STR 11 ON RT…
- 2 Sep 2019
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON UPPER SURFACE LOCATED POINT N1 RIB 16 +6 POINT 2 2 RIB 16+10 POINT 3 RIB 16+15.5 STR 11 RT WING.…
- 2 Sep 2019
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON UPPER SURFACE LOCATED POINT N1 RIB 10+8 POINT 2 RIB 10+14 STR 11 RT WING. PERFORMED PERMANENT REPAIR ON…
- 2 Sep 2019
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON UPPER SURFACE LOCATED RIB 12 +24 STR 8 RT WING. PERFORMED PERMANENT REPAIR ON UPPER SURFACE LOC RIB 12…
- 2 Sep 2019
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED UPPER SURFACE LOCATED RIB 13+16 STR 11 RT WING. PERFORMED PERMANENT REPAIR ON UPPER SURFACE 13 +16 ON STR…
- 2 Sep 2019
Skin, dented
DURING HEAVY MAINTENANCE, EXISTING REPAIR SKIN RT AFT FUSELAGE DENT INSIDE UPPER FUSELAGE. REF NR 2019 258264 REMOVED EXISTING REPAIR DOUBLER ON LOWER…
- 2 Sep 2019
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON UPPER SURFACE LOCATED POINT N1 RIB 14 +16 POINT N2 RIB 14+18 STR 9 RT WING. PERFORMED PERMANENT REPAIR…
- 2 Sep 2019
Skin Panel, corroded
DURING HEAVY MAINTENANCE, C8 CHECK + INTERIOR MODIFICATION AT SAL, REPORTED EXISTING CORROSION REWORK + NEW CORROSION LOCATIONS ON THE UPPER AND LOWER…
- 2 Sep 2019
Doubler, damaged
DURING HEAVY MAINTENANCE, DURING THE AGING AIRCRAFT REPAIR INSPECTION DATED 08/19 PER REF.(1), AN EXISTING REPAIR DOUBLER WAS FOUND INSTALLED ON THE LOWER…
- 2 Sep 2019
Doubler, damaged
DURING HEAVY MAINTENANCE, THE ACCOMPLISHMENT OF THE AGING AIRCRAFT REPAIR INSPECTION (PER REF /4/), AN EXISTING REPAIR DOUBLER WAS FOUND ON THE LOWER AFT…
- 18 Jul 2019
Light, inoperative
DURING HEAVY MAINTENANCE, L1 DOOR LOWER EMERGENCY LIGHT EXIT INOP; REMOVED AND REPLACED EMERGENCY LIGHT IDENTIFIER OF L1 DOOR IAW AMM 33-51-10-400-01 OPS CHK…
- 4 Jul 2019
Battery, failed
FLT 321, BOS-PBI. EMERGENCY LIGHTS DON'T WORK WHEN ON OR WHEN LOSS OF POWER; FOUND EMERG. LIGHT BATTERIES 10WL AND 12 WL FAIL TO TEST. R & R BATTERIES 10WL…
- 4 Jul 2019
Battery, failed
FLT 321, BOS-PBI. EMERGENCY LIGHTS DON'T WORK WHEN ON OR WHEN LOSS OF POWER; FOUND EMERG. LIGHT BATTERIES 10WL AND 12 WL FAIL TO TEST. R & R BATTERIES 10WL…
- 17 Jun 2019
Fan, failed
FT # 299, LGA-MCO. DIVERTED TO JFK. ON TAKE OFF OF LGA WE EXPERIENCED A STRONG ELECTRICAL BURNING SMELL. CONTACTED THE FLIGHT ATTENDANTS. THEY ALSO CONFIRMED…
- 3 May 2019
Apu, leaking
FLT 1255, FLL-GYE. RETURNED TO FIELD. DIRTY SOCKS ODOR PRESENT DURING TAXI TO CLIMB. ODOR WAS NOTED THROUGHOUT CABIN & FLIGHT DECK. ODOR WAS LEAST PRESENT…
- 4 Apr 2019
Filter, odor
FT # 6150, GND-FLL. A STRONG OILY SMELL ON DECENT BELOW 10000 FEET IN CABIN AND IN COCKPIT. ( PACKS - BOTH ); AS PER INFO NOTICE 2017-T015D PERFORMED…
- 4 Apr 2019
Filter, odor
FT # 6150, . A STRONG OILY SMELL ON DECENT BELOW 10000 FEET IN CABIN AND IN COCKPIT. ( PACKS - BOTH ); AS PER INFO NOTICE 2017-T015D PERFORMED DECONTAMINATION…
- 4 Apr 2019
Control Valve, failed
FT # 6150, A STRONG OILY SMELL ON DECENT BELOW 10000 FEET IN CABIN AND IN COCKPIT. ( PACKS - BOTH ); AS PER INFO NOTICE 2017-T015D PERFORMED DECONTAMINATION…
- 25 Feb 2019
Seal, leaking
FT # 251, STRONG ODOR AND FUMES EVENT DESCENDING THROUGH 40000 MUSTY DIRTY SOCK ODOR/FUME PRESENT. INTENSITY DID NOT DIMINISH AND WAS PERSISTENT THIS…
- 16 Aug 2017
Wire Harness, damaged
EMERGENCY EXIT LIGHT INOPERATIVE AT ROW 11DEF. FOUND THE WIRE HARNESS DAMAGED. THE WIRE HARNESS WAS REPLACED IAW AWM 94-40-01. EMERGENCY LIGHTS OPS CHECKED…
- 20 May 2017
Engine, overserviced
FA'S REPORTED A TOXIC, DIRTY SOCK ODOR ON GROUND, IN FLIGHT, AND DURING DESCENT FOR THE THREE LEGS FLOWN. MX FOUND THE NR 2 ENGINE OVERSERVICED BY 2 QUARTS.…
- 12 Mar 2017
Pin, malfunctioned
AIRCRAFT LEFT EMERGENCY EXIT LIGHT NOT ARMED. SLIDE INDICATION MISSING ON ECAM DOOR PAGE. SLIDE INDICATION ON ECAM, OVERWING EXIT NOT ARMED. FOUND THE LT FWD…
- 12 Feb 2017
Relay, failed
PILOT REPORTED THAT ALL CABIN EMERGENCY LIGHTS REMAINED ON AND COULD NOT GET THEM TO EXTINGUISH. R & R RELAY 8WL IAW TSM 33-51-00. OPS CHECK PASSED.
- 14 May 2016
Floorbeam, corroded
DURING MAINTENANCE, AT A HEAVY CHECK BS, CORROSION WAS FOUND ON UPPER SURFACE OF FLOORBEAM, Y-765, RT AFT FRAME 68. R & R RT FLOORBEAM AT FRAME 68, Y-765 IAW…
- 14 May 2016
Dummy Rail, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON FWD CABIN WET AREA DUMMY RAIL, LOCATION: ALONG FRAMES 12-16, STR 23LT; R & R DUMMY BEAM IAW SRM 51-72-11 AND…
- 14 May 2016
Floorbeam, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON UPPER SURFACE OF FLOORBEAM, 765 AT FRAME 66, LAV MOUNT. R & R FLOORBEAM IAW SRM 51-42-11.
- 14 May 2016
Floor Support, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON UPPER SURFACE OF FLOOR SUPPORT 765 LT AT FRAME 68-70. CORROSION WAS REMOVED. FLOORBEAM WAS R & R IAW SRM 51-42-11.
- 14 May 2016
Shear Plate, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON LOWER SIDE OF FLOOR STRUCTURE UNDER SHEAR PLATE, LOCATION,-1292; R & R FLOOR SUPPORT IAW SRM 51-72-11.
- 14 May 2016
Shear Plate, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON SHEAR PLATE LOCATION:-1292 RT BETWEEN FRAMES 69 AND 70; R & R SHEAR PLATED IAW SRM 51-72-11.
- 14 May 2016
Floor Support, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON FLOOR SUPPORT UPPER SURFACE, 1292 FR 67 AND 68. R & R FLOOR SUPPORT IAW SRM 51-42-11.
- 14 May 2016
Floor Support, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON FLOOR SUPPORT 1292 LT AT FRAME 66. R & R FLOOR SUPPORT FROM FRAME 64 TO 66 IAW SRM 51-42-11.
- 14 May 2016
Floor Support, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON AFT CABIN LT SIDE, FLOOR SUPPORT 1292 AFT BEAM OF TRIPLE BEAM AND THE FWD SPLICE HAS ELONGATED HOLES. FRAMES 67 +10…
- 14 May 2016
Shear Plate, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON SHEAR PLATE 1292 LT BETWEEN FRAMES 69 AND 70; R & R SHEAR PLATE IAW SRM 51-42-11.
- 14 May 2016
Floor Support, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON LOWER SIDE OF FLOOR SUPPORT, FRAMES 69-70. R & R FLOOR SUPPORT IAW SRM 51-42-11.
- 14 May 2016
Floor Support, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON FWD CABIN WET AREA FLOOR SUPPORT 1292, FRAME 20. R & R THE FLOOR SUPPORT IAW SRM 51-42-11.
- 14 May 2016
Floor Support, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON UPPER SURFACE OF FLOOR SUPPORT -1292 RT AT FRAME 68. R & R THE FLOOR SUPPORT IAW SRM 51-42-11.
- 14 May 2016
Door Sill, corroded
DURING MAINTENANCE, CORROSION WAS FOUND ON AFT CARGO BAY BULK DOOR SILL, STR 38R BETWEEN 60 AND 62. R & R AFT CARGO BAY BULK DOOR SILL IAW SRM 51-42-11.
- 18 Jan 2016
Battery, failed
EMERGENCY LIGHT FAILS TEST; R & R EMERGENCY LIGHT BATTERY AT 13WL. BITE AND OPS CHECKS GOOD IAW AMM 33-51-11.
- 23 Aug 2015
Wire Harness, damaged
DURING MAINTENANCE, FOUND EMERGENCY LIGHT 15ABC INOPERATIVE. R & R INSEAT CABLE HARNESS AT 15LT IAW ESPM 20-33-11. OPS NORMAL.
- 15 Mar 2015
Connector, unsecure
DURING GROUND STOP, EMERGENCY LIGHT INOPERATIVE AT ROW 15. FOUND LOOSE CONNECTOR. TIGHTEN AND SECURED CONNECTOR. OPS CHECKED GOOD.
- 24 Apr 2014
Battery, failed
ON MAINTENANCE CHECK, FOUND EMERGENCY POWER SUPPLY UNIT FWD LT AT FAULT. R & R FWD LT EPSU BATTERY IAW AMM 33-51-38. OPS CHECK NORMAL.
- 9 Feb 2013
Battery, failed
FLT 654 SJU-TPA, ON GROUND MAINTENANCE CHECK FOUND EPSU FIN 12WL BATTERY FAULT. REMOVED AND REPLACED EPSU BATTERY AT FIN 12WL IAW AMM 33-51-38.
- 16 Oct 2011
Antenna, failed
FLT 753, JFK-CUN, AIRCRAFT DIVERTED TO MCO DUE TO WEATHER RADAR SYS INOP. QRH RESET PROCEDURE WAS ATTEMPTED WITH NO SUCCESS. FOUND RADAR DRIVE ANTENNA STUCK…
- 18 Jul 2011
Transceiver, failed
FLT 1761 FLL-SJU, WX RADAR HAD TO BE TURNED OFF AFTER A RED SWEEP ON HALF OF THE ND FOLLOWING BY A BURNED/ELECTRICAL ODOR DURING BAD WX AND STATIC…
- 23 May 2006
Damper, leaking
DURING C-1 CHECK PER ROUTINE CARD 10100-J1-1/8 DISCOVERED R1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER HAS BEEN DISCHARGED INDICATING 0 PRESSURE IN THE…