N598JB
2004 Airbus A320-232 standard FAA →
registration
- 2004
service difficulty reports
66 reports
- 27 Aug 2026
Slide, failed
FLT#1727, EWR-MCO. REF LP 4790713 ITEM 1 DURING T/S FOUND L2 DOOR SLIDE LIGHTS BAD. SLIDEREQUIRES REPLACEMENT; REMOVED & REPLACED L2 DOOR SLIDE IAW AMM…
- 14 Jul 2026
Tru, failed
FLT 1761, LGA-PBI. ON WEEKLY CHK; EMERGENCY GEN SYS OPS CHK FAILED. ESS TR & OUTPUT AMPS IN AMBER ; REMOVED & REPLACED ESS TR 1PE IAW AMM 24-34-51-400-001-A.…
- 9 Jun 2025
Oil System, leaking
FLT#1858, AUA-JFK. 'FUME IN COCKPIT DESCENDING BELOW 12K DIRTY SOCK SMELL. NO ODOR IN BACK, FA'S SAID NOTHING; PERFORMED DETAILED VISUAL INSPECTION OF APU,…
- 17 Nov 2023
Unknown, unknown
FLT#271, LGA-FLL. ' DIRTY SOCKS SMELL ON DESCENT BY ROW 19 TO 10, 2 FA'S FRONT SMELLED IT 2 FAS IN BACK DID NOT PILOTS DID NOT SMELL IT; COMPLIED WITH…
- 21 Oct 2023
Unknown, unknown
FLT#613, HPN-FLL. (AIRCRAFT DIVERTED TO JFK) ' AFTER TAKEOFF FROM HPN LANDING GEAR INDICATION AFTER GEAR UP LANDING GEAR DOORS NOT CLOSED W FOLLOWED CHECK…
- 9 Jul 2022
Sensor, dirty
FLT#1731, SLC- LAX. 'FWD CARGO DOOR INDICATION AFTER T/O ( ECAM IND CARGO DOOR (FWD/AFT & BULK) ); CLEANED SENSOR AND CONTACTS AT FWD CARGO DOOR. OPS CHECK…
- 25 Apr 2022
Proximity Sensor, failed
FLT#1379, DCA-FLL. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL). 'AFT CARGO DOOR CAUTION MESSAGE DISPLAYED AFTER TAKEOFF( ECAM IND CARGO DOOR (FWD/AFT & BULK)…
- 2 Mar 2022
None, none
FLT # 2060, RSW-LGA(EMERGENCY DECLARED TO JFK). ON SHORT FINAL WITH FLAP APPLICATION HYD & RESERVOIR FLUID LOW-LEVEL SCHEMATIC SHOWED COMPLETE LOSS OF "G"…
- 22 Sep 2021
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR STRUCTURE LH WEB BTW FR69 & FR 70 AT AFT GALLEY AREA (CPCP RELATED REFER TO MPD TASK 534195-01); R & R FLOOR…
- 22 Sep 2021
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION ON FLOOR BEAM +Y765, FR 68, AT AFT GALLEY AREA (REF CPCP MPD TASK 534195-01); R & R FLOOR BEAM Y765 AT AFT GALLEY AREA IAW…
- 22 Sep 2021
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM SYTRUCTURE L/H WEB BTW FR69 AT AFT GALLEY AREA (CPCP RELATED REFER TO MPD TASK 534195-01); R & R FLOOR…
- 22 Sep 2021
Shear Plate, corroded
DURING HEAVY MAINTENANCE, CORROSION SHEAR PLATE STR 23RH BTW FR69 & FR 70, AFT GALLEY AREA ( CPCP RELATED REFER TO MPD 534195-01); R & R SHEAR PLATE STGR 23…
- 22 Sep 2021
Support, corroded
DURING HEAVY MAINTENANCE, CORROSION ON LOWER SILL, LH FR 69, AFT GALLEY AREA (CPCP RELATED TASK MPD 534195-01); REMOVED CORROSION ON REWORK AREAS P1, P2, & P3…
- 22 Sep 2021
Slide, out of position
DURING HEAVY MAINTENANCE, ESCAPE SLIDE DOOR 841 TOUCHES THE FUSELAGE PER AMM 25-62-44-400-803-A POCEDURE 4.B.12 (C) ; (REF AEROMAN NR 2021-382146) R & R SLIDE…
- 27 Apr 2021
Unknown, odor
FLT # 473, BOS-AUA. STRONG FUMES AFT ON CLIMBOUT WHICH DISAPPEARED @ CRUISE IN DESCENT FUMES STRONG OBSERVED COCKPIT AND CABIN FOLLOWED ALL FROM V1 SUPP…
- 10 Apr 2021
Apu, odor
FLT 2459, BDL-FLL. AFTER FULL THRUST TAKE OFF DIRTY SOCKS SMELL FOR ABOUT 5 MINUTES. SMELL CLEARED UP UNTIL AFTER LANDING, ON TAXI IN SMELL RETURNED TILL…
- 28 Feb 2021
Unknown, odor
FLT 1793, JFK-SJO. FA #3 AND 1 SMELT STRONG ODOR OF DIRTY SOCK SMELL IN THE AFT CABIN. #3 VOMITED WITH HEADACHE. I WAS TOLD OF THIS AFTER LANDING THROUGH…
- 5 May 2020
Battery, failed
FT # 282, UVF-JFK. BATTERY 10WL ESPU FAILED BATTERY CAPACITY CHECK REFER T/C A320-33-51-00-710-003; R & R BATTERY 10WL REFER AMM 33-51-38. OKAY FOR SERVICE .…
- 25 Jan 2020
Battery, no test
WHILE PREFORMING TASKCARD A320-33-51-00-710-003 FIN 11WL BATTERY FAIL DURING BATTERY CAPACITY TEST; R & R EPSU BATTERY IAW AMM 33-51-38. BITE TEST OKAY.
- 25 Jan 2020
Battery, no test
WHILE PREFORMING TASKCARD A320-33-51-00-710-003 FIN 12WL BATTERY FAIL DURING BATTERY CAPACITY TEST; R & R EPSU BATTERY IAW AMM 33-51-38. BITE TEST OKAY.
- 4 Aug 2019
Unknown, odor
FLT 96, RETURNED TO FIELD. INFLIGHT, SMELLED SMOKE IN AFT GALLEY AND ROWS 25, 26, AND 27. ACCOMPLISHED CHAPTER 5 INSPECTION IAW AMM 05-50-00-810-831-A FOUND…
- 6 Jun 2019
Structure, cracked
DURING HEAVY MAINTENANCE, LH OVERWING AFT EMERGENCY EXIT HATCH FORWARD & AFT UPPER & LOWER SEGMENT 1 IS CRACKED AT SEVERAL FASTNER LOCATIONS. REF 440573 -…
- 6 Jun 2019
Structure, cracked
DURING HEAVY MAINTENANCE, RH AFT OVERWING EMERGENCY EXIT HATCH FORWARD & AFT UPPER & LOWER FRAME SEGMENT 1 IS CRACKED AT SEVERAL FASTNER LOCATIONS. REF.…
- 6 Jun 2019
Structure, cracked
DURING HEAVY MAINTENANCE, REF 440573 38553&38551 LH OVERWING FWD EMERGENCY EXIT HATCH FORWARD UPPER AND LOWER AFT FRAME SEGMENT 1 CRACKED AT FASTENER…
- 6 Jun 2019
Structure, cracked
DURING HEAVY MAINTENANCE, RH FWD OVERWING EMER HATCH UPPER AND LOWER AFT FRAME SEGMENT 1 IS CRACKED AT HOLES 2.5.6.7.8.9.14.16.17. AND 18 TOTAL LENGTH 0.830"…
- 6 Jun 2019
Door Sill, corroded
DURING HEAVY MAINTENANCE, R2 PAX DOOR SILL FRAME 68 STR 23RH HAD CORROSION NOT CPCP TASK CARD; REF HAECO NR S/O# 440573 NR# 38637 REPAIRED AREA AT FR68 STR…
- 6 Jun 2019
Frame, cracked
DURING HEAVY MAINTENANCE, R/H CENTER WING BOX FRAME 36 PRESSURE PANEL ATTACHMENT HOLE B IS CRACKED IN THE TITANIUM ANGLE AT 6:00; REF HAECO SO# 440573 NR#…
- 6 Jun 2019
Skin, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION FOUND ON THE FUSELAGE RH CENTER WING BOX PRESSURE PANEL ATTACHMENT HOLE B BETWEEN FR 35& FR 36. NOTE: NO…
- 7 Mar 2019
Unknown, odor
FLT 668, PSE-MCO. MAGIC MARKER ODOR SMELL IN FLIGHT DECK AT APPROX 3000FT DURING APPROACH FOR LANDINGS ENGINES WERE AT IDLE THRUST; PER CABIN ODOR REPORT…
- 9 Sep 2018
Switch, faulty
FLT 882, UVF-JFK. CABIN EMERG EXIT LIGHTS REMAIN ILLUMINATED ALL FLIGHT. FOUND EMERG LIGHT SWITCH TO BE AT FAULT. REPLACED LIGHT SWITCH REF ESPM 20-45-00 &…
- 15 Jun 2018
Power Supply, failed
POWER SUPPLY 10WL FAULTED. REMOVED & REPLACED THE POWER SUPPLY IAW AMM 33-51-38.
- 23 Mar 2018
Target, out of adjust
RETURNED TO FIELD DUE TO A DOOR FWD CARGO LIGHT ILLUMINATED AFTER TAKEOFF AT 200 FT. LEVELED OFF AT 4000 FT. CABIN PRESSURE CLIMBED TO 4000 FT. CABIN WAS NOT…
- 6 Jan 2018
Duct, contaminated
FLT 1095, BOS-PUJ. RETURNED TO FIELD (BOS). AFTER TAKEOFF CLIMBING THROUGH 10,000, FUMES SMELT IN COCKPIT & CABIN. DESCRIBE SMELL AS BURNING PLASTIC. CABIN…
- 30 Sep 2017
Battery Pack, no test
EMERGENCY LIGHT BATTERY 11WL FAILED TO TEST. R & R THE BATTERY IAW AMM 33-51-38. OPS CHECKED OK.
- 22 Jun 2017
Power Supply, no test
DURING HEAVY MAINTENANCE, EMERGENCY EXIT LIGHT TEST FOUND EPSU EMERGENCY LIGHT (11WL) INTERNAL FAULT IN PASSENGER CABIN . REPLACED EPSU ON EMERGENCY EXIT…
- 19 Mar 2017
Warning Message, illuminated
PERFORMED AIR RETURN, DUE TO ELECTRIC DC BATTERY BUSS FAULT. ECAM CAME ON THREE TIMES DURING CLIMB OUT. R & R THE NR 2 SDAC IAW AMM 31-55-34 AND R & R…
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND AFT CABIN FLOORBEAM -Y765, FR 66 CORRODED. REPLACED THE FLOORBEAM IAW SRM 51-72-11.
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE FOUND REF PEMCO RT OTBD SEAT TRACK -1292, FRAME 20 CORRODED. REPLACED FLOORBEAM IAW SRM 51-42-11.
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE FOUND AFT CABIN FLOORBEAM Y1292, FR68 CORRODED. REPLACED FLOORBEAM IAW SRM 51-42-11.
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE FOUND AFT CABIN FLOORBEAM FR 66, Y765, Y1292 CORROSION. REPLACED FLOORBEAM IAW SRM 51-72-11. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL…
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE FOUND AFT CABIN FLOORBEAM -Y1292, FR 66 CORRODED. REPLACED FLOOR BEAM IAW SRM 51-42-11.
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND AFT CABIN FLOOR STRUCTURE FLOORBEAM, -Y1292, FR 67 CORRODED. REPLACED FLOORBEAM IAW SRM 51-42-11.
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE FOUND FLOORBEAM, Y1292, FR 66, CORRODED. REPLACED THE FLOORBEAM IAW SRM 51-72-11.
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE FOUND AFT CABIN FLOORBEAM Y1292, FR 68 CORRODED. REPLACED THE FLOORBEAM IAW SRM 51-72-11.
- 3 Nov 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND AFT CABIN FLOORBEAM -Y1732, FR 66, CORRODED. REPAIRED THE FLOORBEAM IAW SRM 53-41-14.
- 24 Mar 2014
Eec, failed
AIRCRAFT DIVERTED. AFTER LEVELING AT CRUISE, STATUS PAGE SHOWED STATUS INOPERATIVE SYS, WHEN SLATS OUT, REVERSER 2, ENG 2 AT IDLE ENG 2 THRUST ON GROUND MAX…
- 10 Feb 2014
Power Supply, failed
ON HEAVY MAINTENANCE CHECK, FOUND LT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. R & R EMERGENCY POWER SUPPLY UNIT 11 WL IAW AMM 33-51-38. OPS CHECK GOOD IAW…
- 27 Dec 2013
Control Valve, failed
CREW DECLARED AN EMERGENCY AND ACFT DIVERTED, PACK 2 FAULT IN FLIGHT. RESET DID NOT WORK WITH PACK 1 ON MEL, CAUSED CABIN ALT TO EXCEED 11500'. CREW PERFORMED…
- 21 Oct 2012
Connector, out of position
FLT 984 TPA-LGA, EXIT LIGHT NOT ILLUMINATED AIRCRAFT SERVICE DOOR A/C LEFT EMERGENCY OVERHEAD DOOR LIGHT ILLUMINATED. PERFORMED TEST OF EPSU'S AS PER AMM…
- 10 Oct 2012
Appu, failed
FLT 362 PBI-LGA, CREW DECLARED EMERGENCY AND DIVERTED TO JFK DUE TO WHEN EXTENDING FLAPS TO "FLAP 2" A ECAM "F/CTL FLAPS LOCKED" APPEARED. RAN QRH 7-9.…
- 22 Jun 2012
O-Ring, damaged
FLT 893 BOS-STI, CREW DECLARED AN EMERGENCY DUE TO HYD Y RESERVOIR LO LEVEL ECAM APPEARED AT FL200, CONFIRMED HYD PAGE. FOUND LEAK AROUND NR 2 ENG CHECK VALVE…
- 2 Sep 2011
Epsu, failed
FLT 11 JFK-FLL, DURING MAINTENANCE EMERGENCY LIGHT TEST FAILED AT LEFT FWD EPSU. REMOVED AND REPLACED LEFT FWD EPSU IAW AMM 33-51-38, CHECK OK.
- 5 May 2011
Paddle, misinstalled
FLT 445 BOS-TPA, ON GROUND MAINTENANCE CHECK FOUND L2 DOOR SLIDE ARMED LIGHT INOP. FOUND YELLOW ARM LEVER PADDLE INSTALLED INCORRECTLY. RE-INSTALLED PADDLE ON…
- 20 Dec 2010
Servo Control, out of limits
FLT 1797 FLL-SDQ, AIR RETURN TO FLL - DURING CLIMBOUT OF 27,000 FEET EXPERIENCED EXTREME AIRFRAME VIBRATION. AUTO PILOT WAS DISCONNECTED AND AIRCRAFT WAS…
- 25 Mar 2010
Power Supply, failed
FLT JB986 FLL-JFK AFTER FLIGHT DURING RON MX FOUND L2 AND R2 LWR EXIT EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED AFT POWER SUPPLY PER AMM 33-51-38,…
- 14 Oct 2009
Fan, seized
FLT 834 STI-JFK, VENT BLOWER FAN FAULT IN FLT A LOUD SQUEALING SOUND FOR APPROX 10 MINUTES. SQUEAL ABRUPTLY ENDED FOLLOWED BY A BURNT ELECTRICAL SMELL…
- 1 Oct 2009
Computer, malfunctioned
FLT 126 DEN-JFK - DECLARED EMERGENCY TO JFK DUE TO FLAPS STUCK A ZERO WHEN HANDLE MOVED TO FLAPS 2 AND 3 POSITION. SLATS WORKED AS ADVERTISED. PER TSM…
- 29 Sep 2008
Power Supply, discharged
LT EPSU FAILED DURING EMERGENCY LIGHT SYSTEM TEST (13WL). REMOVED AND REPLACED LT EPSU AS PER AMM 33-51-38-04. SYSTEM OPS CHECK NORMAL.
- 14 Apr 2008
Electrical Box, faulty
FLT 760, SJU-BOS, FLT ATTENDANT DETECTED BURNED ELECTRICAL ODOR AROUND MID CABIN (ROWS 6-8) ABOUT 1 HOUR AND 20 MINUTES INTO FLT. THE LTV'S WERE TURNED OFF…
- 5 Sep 2005
Sign, failed
FWD EMERGENCY EXIT LIGHT INOP WHEN ARMED AND GEAR DOWN. REMOVED AND REPLACED EMERGENCY EXIT SIGN (40 WL) ABOVE R1 DOOR IAW AMM 33-51-16, OPS CHECK GOOD. THE…
- 4 Sep 2005
Battery, failed
FWD EPSU FAILED BATTERY SYSTEM CHECK. REPLACED FWD EPSU FIN 10WL PER AMM 33-51-38-04.
- 4 Sep 2005
Power Supply, failed
FORWARD ENTRY EXIT LIGHTS BOTH SIDES DID NOT ACTIVATE WITH GEAR EXTENSION NOR ACTIVATE MANUALLY. EPSU FWD -L- FAILS BITE CHECK. REMOVED AND REPLACED EPSU AND…
- 28 Aug 2005
Sign, failed
FWD EMERGENCY EXIT LIGHTS NOT WORKING. REPLACED EXIT SIGN 50WL, CHECKS OK REF 33-51-00. THE 50WL LIGHT HOUSING IS A CONSUMABLE PART WITH NO SERIAL NUMBER.
- 24 Aug 2005
Power Supply, inoperative
L & R FORWARD EXIT LIGHTS INOPERATIVE. REMOVED AND REPLACED EPSU 10WL IAW AMM 33-51-38-04.
- 17 Aug 2005
Power Supply, inoperative
DURING PREFLIGHT, FOUND BOTH FWD CABIN DOOR EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED EPSU PER 33-51-38, OPERATIONS CHECK NORMAL.
- 16 Aug 2005
Cooling Fan, failed
JUST PRIOR TO DESCENT AFT AVIONICS COMPARTMENT INDICATED SMOKE. RESET SYSTEM AND TESTED OK. LEFT SYSTEM OFF FOR REST OF FLIGHT. R&R COOLING FAN ASSY IAW LTV…