N594EL
2004 Airbus A318 standard FAA →
earlier registrations
1 past record
- 2004
service difficulty reports
6 reports
- 10 Sep 2018
Warning System, activated
DURING TAKE OFF MESSAGE APPEAR L/G DOORS NOT CLOSED. DMI WAS CREATED 32-31-00 CAT B.
- 29 Apr 2016
Hinge Fitting, vibration
SEVERE ACFT VIBRATION FELT AT FL 290 WITH A SPEED OF APROX 290 KTS & THROUGHOUT 260 KTS VIBRATION STOPPED. IAW TSM 05-50-00-810-801-A IDENTIFICATION OF THE…
- 18 Feb 2015
Servo Control, faulty
DURING CLIMB AT FLIGHT LEVEL 320 STRONG HARMONICS VIBRATION WAS FELT ON THE ENTIRE ACFT. IAW AMM 27-34-00-200-001A & 27-24-00-200-002A, ELEVATOR & RUDDER, THE…
- 14 Feb 2015
Seal, vibration
DURING CLIMB PASSING FL300, CLIMB SPEED NOTING CONDITION & NO TURBULENCE. THE ACFT HAD A VERY STRONG VIBRATION FOR ABOUT 30 SECONDS. AFTER REDUCING SPEED &…
- 26 Jan 2015
Proximity Switch, out of adjust
DOOR AFT AVIONICS OPEN ON ECAM DURING INITIAL CLIMB THROUGH 11.000 FT. RETURNED, WAS REQUIRED BY ECAM DUE TO MEMO. ACCOMPLISHED VISUAL CHECK OF AVIONICS…
- 5 Oct 2013
Valve, failed
DURING CLIMB, ECAM DISPLAYED VENT AVIONICS SYSTEM FAULT. OPS TEST OF THE AVIONICS EQUIMENT VENTILATION FROM MCDU WAS PERFORMED TEST SATISFACTORY IAW-AMM…