N592QS
2007 Cessna 560XL standard FAA →
registration
- 2007
service difficulty reports
21 reports
- 6 Aug 2026
Fire Loop, false activation
RIGHT FIRE DET SYS CAUTION LIGHT ILLUMINATED AT 2500 FEET AGL 160 KIAS IN LIGHT RAIN. REMAIN ILLUMINATED FOR REMAINDER OF FLIGHT. REMOVED FALLED FIRE LOOP PN…
- 24 Apr 2026
Vertical Beam, corroded
DURING EMPENNAGE COVE INSP, FOUND VERTICAL AFT SPAR HAS CORROSION ON RH ANGLE ABOVE TOP RUDDER HINGE. BLENDED AND REMOVED ALL VISIBLE SIGNS OF CORROSION ON…
- 24 Apr 2026
Skin Panel, corroded
FOUND SEVERAL SPOT OF CORROSION ON FWD FUSELAGE RH LOWER SECTION JUST FWD PANEL 153AC. BLENDED AND REMOVED CORROSION FROM FWD FUSELAGE RH LOWER SECTION JUST…
- 1 Mar 2026
Door, binding
WHEN OPENING OR CLOSING THE MAIN CABIN DOOR YOU CAN HEAR AND PHYSICALLY FEEL THAT SOMETHING IS BINDING. IT HAPPENS WHEN YOU OPEN THE DOOR IS ABOUT 3/4 OPEN AS…
- 14 Sep 2025
Precatch, malfunctioned
DOOR PRECATCH DOES NOT RELEASE THE DOOR WHEN PULLED TO RELEASE, THE PRECATCH HOLDS THE DOOR WHEN PRECATCH HANDLE IS NORMAL BUT DOES NOT RELEASE IT WHEN PULLED…
- 3 Jul 2025
Precatch, faulted
THE MAIN CABIN DOOR PRE-CATCH WILL NOT RELEASE THE DOOR. PERFORMED LUBRICATION OF LH & RH TR GUIDE RODS AND PIVOT POINTS USING D5100NS LUBRICANT. NO DEFECTS…
- 17 Mar 2025
None, no discrepancy
ON DESCENT THROUGH 17000FT AT 295 KIAS, WE ENCOUNTERED SEVERE TURBULENCE FOR APPROXIMATELY 10SECONDS. WE HAD THE FLAPS AND GEAR UP, CLEAN CONFIGURATION, BUT…
- 7 Mar 2025
Light, faulted
WHILE FLYING AS THE SUN SET, WE HAD THE PASSENGER SAFETY SWITCH IN THE OFF POSITION, AS WELL AS SEAT BELT ON POSITION, AND NOTICED THE FRONT CABIN EMERGENCY…
- 11 Feb 2025
Floorboard, cracked
DURING 24-MONTH LOWER AFT CABIN INTERNAL (BELOW EXTERNALLY SERVICED TOILET) STRUCTURAL AND CORROSION SPECIAL DETAILED INSPECTION PANEL 262HR WAS FOUND CRACKED…
- 2 Jan 2025
Thrust Reverser, damaged
DURING MAINTENANCE, THE LH TR WAS DAMAGED WHEN IT STRUCK THE FLOOR CORRECTIVE ACTION: INSTALLED SEAL FLANGE REPAIR DOUBLER. IAW SRM 51-40-03
- 16 Jul 2024
Rod, binding
MAIN CABIN DOOR IS DIFFICULT TO OPEN AND CLOSE. THE FORWARD TELESCOPING ROD IS BINDING AT ABOUT MID TRAVEL. GVI OF MAIN CABIN DOOR FOUND THE LOWER HARDWARE ON…
- 11 Apr 2018
Unknown, odor
AT 40000 FT, DETECTED AN OIL ODOR IN THE COCKPIT AND CABIN. RAN THE CHECKLIST FOR ODOR. INSPECTED APU INLET DUCT FOR PRESENCE OF OIL. NONE FOUND. REMOVED AND…
- 23 Nov 2015
Control Wheel, out of adjust
ELEVATOR TRIM WHEEL IS LOOSE, ELEVATOR TRIM IS JAMMED & WILL NOT MOVE AFT OF MID TAKEOFF RANGE ELECTRICALLY OR MANUALLY. INSPECTED ELEVATOR TRIM AFT CABLE…
- 1 Feb 2014
Steering Sys, misaligned
AFTER RETRACTING THE GEAR AFTER TAKEOFF THERE WAS A RED GEAR UNLOCK LIGHT ON. LG EXTENDED NORMALLY. AFTER LANDING WITH THE NOSE WHEEL STRAIGHT THE RUDDER…
- 28 Jun 2013
Acm, failed
DURING PREFLIGHT WITH THE APU BLEED IN NORMAL, ACM FAN MADE A LOUD NOISE, NOTICED A BURNING ODOR IN CABIN, CABIN SUPPLY TEMP STARTED IN 130'S AND CLIMBED TO…
- 13 Nov 2012
Hinge Bracket, cracked
DURING A SCHEDULED INSPECTION, FOUND THE RT ELEVATOR OTBD HINDGE BRACKET CRACKED. PERFORMED AN EDDY CURRENT CHECK AND VERIFIED THE HINGE WAS CRACKED ON THE…
- 30 Mar 2012
Brake Sys, none
BRAKES WON'T KEEP THE ACFT STOPPED WITH POWER SET TO TAKEOFF SETTING. INSPECTED BRAKE ASSEMBLIES, FOUND NO DEFECTS. ALL CHECKED GOOD AT THIS TIME IAW MM…
- 12 Jun 2011
Windshield, failed
RIGHT WINDSHIELD FAULT LIGHT ILLUMINATED. NO OVERHEAT LIGHT. SHORTLY AFTER RT WINDSHIELD SHATTERED. WINDSHIELD SEAL LOOKS BUCKLED ON TOP CENTER PORTION.…
- 1 Sep 2010
Pulley, damaged
IN FLT, GEAR UP, & FLAPS RETRACTED, A PRONOUNCED GRINDING/BINDING OF ELEVATOR WHEN YOKE IS MOVED FORE & AFT. NOTICABLE WHEN HAND FLYING BETWEEN 160KIAS & 220…
- 5 May 2008
Apu, leaking
ON THE GROUND WITH THE APU RUNNING FOR SEVERAL MINUTES, SECONDS AFTER SWITCHING BLEED AIR ON, SMOKE STARTED COMING INTO THE CABIN FROM ALL WEMACS VENTS.…
- 27 Nov 2007
Unknown, odor
WHILE ON GROUND WITH APU RUNNING AND BLEED AIR ON HAD BURNING ODOR COMING THRU COCKPIT DUCTS. REMOVED & REPLACED DEFECTIVE TEMP CONTROLLER OPERATIONAL CHECK…