N591NW
2003 Boeing 757-351 standard FAA →
registration
- 2003
NTSB
- 11 Mar 2019
accident, Atlanta GA
service difficulty reports
166 reports
- 2 Oct 2026
Proximity Sensor, faulted
L2 DOOR SLIDE LIGHT STAYS ILLUMINATED WITH DOOR DISARMED. R & R L2 AFT GIRT BAR PROX SENSOR IAW AMM 25-66. OPS CHECKED GOOD. (9112858)(AIRCRAFT GROUNDED)
- 14 Sep 2026
Frame, cracked
A CRACK WAS FOUND OF 0.125IN LENGTH APROX. ON FUSELAGE FRAME STA. 1640 JUST BELLOW STGR 14 LH. REPAIRED PER ERA 636323-14AD (1813334)(AIRCRAFT GROUNDED)
- 12 Sep 2026
Spring, broken
BROKEN SPRING OF OUTSIDE HANDLE UP FLAPPER AT AFT LH EMERGENCY EXIT HATCH. SPRING OF HINGE WAS REPLACED EFECTIVITY WAS VERIFIED PER AIPC 52-22-01-05 ITEM 495.…
- 28 Aug 2026
Seat Track, corroded
CORROSION ON BASE OF SEAT TRACK STA 1640 RBL24 & 48. DAMAGED AREA REPLACED PER B757-300 SRM 51-40-02(1782451)(AIRCRFT GROUNDED)
- 27 Aug 2026
Strap, cracked
CRACKED STABILIZER STRAP OF CABIN FLOOR STRUCTURE AT BS 377.7, LBL 48, AT LH TUNNEL OF MAIN EQUIPMENT COMPARMENT. REPAIRED IAW SRM 53-00 (1780101)(AIRCRFT…
- 27 Aug 2026
Strap, cracked
CRACK ON STABILIZER STRAP AT BS 560, LBL 45, ON CEILING AT FWD CARGO BAY. STABILIZER STRAP AT BS 560, LBL 45, ON CEILING AT FWD CARGO BAY WAS REPAIRED IAW SRM…
- 26 Aug 2026
Strap, cracked
CRACKED STABILIZER STRAP OF CABIN FLOOR STRUCTURE AT BS 395 RBL 0 AT RT TUNNEL OF MAIN EQUIPMENT BAY. REPAIRED IAW SRM 53-00 (1778880)(AIRCRFT GROUNDED).
- 25 Aug 2026
None, none
DURING INSPECTION OF ERA 529959-14. PERMANENT REPAIR STEP 11 REAPIR WAS IDENTIFIED IAW DAL P.S 900-5-1 (1776966)(AIRCRFT GROUNDED)
- 24 Aug 2026
Seat Track, corroded
CORROSION ON RT INBD/OUTBD SEAT TRACK FROM BS 365.25 TO 377.7. SEAT TRACK FROM BS 365.25 TO 377.7 AT W1 WERE REPLACED IAW SRM 51-40-02 (1774822)(AIRCRFT…
- 22 Aug 2026
Deck Plate, corroded
CORROSION ON DECK PLATE STA 1700 RBL 21-24 AT CPAX OUT OF LIMITS ORIGINAL THICKNESS DECK PLATE. REPAIRED IAW SRM 53-60-51 (1770688)(AIRCRAFT GROUNDED)
- 30 Jul 2026
Battery Pack, inoperative
CEILING EMERGENCY LIGHTS AT ROWS 28, 30, 33 INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PACK M11383 IAW AMM 33-51. (9599829)(AIRCRAFT GROUNDED)
- 23 Jul 2026
Wire, broken
EMERGENCY LIGHTS AT SEATS 14-20 INOP. FOUND BROKEN GROUND WIRE AT ROW 20. REPAIRED WIRE PER SWPM 20-10 . EMERG LIGHTS OPS CHECK GOOD PER AMM 33-51.…
- 24 Jun 2026
Lanyard, unsecure
CHORD UNDER DOOR 1L LIFE RAFT. RESECURED LANYARD FOR SURVIVAL KIT ATTACHEMENT TO DOOR SLIDE ASSY. (8709666) AIRCRAFT WAS GROUNDED
- 20 Apr 2026
Girt Bar, lack of lube
ARMING LEVER DOES NOT GO TO THE PROPER POSITION...IT REMAINS SLIGHTLY TILTED FORWARD / INTERIOR. LUBRICATED GIRT BAR ASS. PER B757 AMM 52-11 DOOR OPERATES…
- 15 Apr 2026
Proximity Sensor, faulted
DURING WAKE UP NOTICED R WING SLIDE EICAS MSG CAME BACK. REPLACED PROXIMITY SENSOR S10374 IAW MM 52-71-00. AIRCRAFT WAS GROUNDED
- 26 Mar 2026
Support Angle, cracked
FOUND CRACK IN AFT CARGO DOOR STA 1420 UPPER SUPPORT ANGLE. REMOVED BOLT AT CRACK LOCATION FOR VERIFICATION OF CRACK. REMOVED AFT CARGO DOOR PER B757 AMM…
- 26 Mar 2026
Door, cracked
DAMAGE TOLERANCE EVALUATION (DTE) REQUIRED. ERA 633380-14 SECTION I, AFT CARGO DOOR UPPER EDGE, SUPPORT ANGLE BS 1420 CRACKED. ISSUED TO MTC. FOLLOW ON ACTION…
- 1 Mar 2026
Battery, no test
SHIP 5811, DURING SERVICE CHECK FOUND EMERGENCY EXIT LIGHTS INOPERATIVE AT ROWS 46-49 AND DOOR 4L. R & R POWER SUPPLY BATTERY FOR EMERGENCY LIGHTS IN AFT…
- 5 Jan 2026
Line, unsecure
L2 MOORING LINE LOOSE. SECURED L2 MOORING LINE IAW AMM 25-66. (8402304)
- 15 May 2025
Battery, inoperative
SHIP 5811 ROW 24-27 EEPLS INOP AND RH LWR EMERG EXIT SIGN INOP. R/R BATTERY AND CHARGER ASSY M11488 REF B757 AMM 33-51 OPS GOOD ALSO REPLACED BATT AT M11384…
- 10 Apr 2025
Oven, fire
SHIP 5811 -DIV/FIRE/DE- TO ATL DUE TO REPORTED FIRE FROM FORWARD GALLEY OVEN WITH ELECTRICAL SMELL. CORRECTIVE ACTION: INSPECTED LIGHTS, BALLASTS, GALLEY WIRE…
- 31 Mar 2025
Power Supply, inoperative
SHIP 5811 EMERGENCY EXIT ISLE LIGHTS OUT AT SEAT 24, 25, 26. CORRECTIVE ACTION: REPLACED PWR SUPPLY M11488 REF B-757 AMM 33-51 OPS CHECK GOOD. (7137156)
- 29 Mar 2025
Girt Bar, obstructed
SHIP 5811 L4 DOOR WILL NOT ARM. CORRECTIVE ACTION: FOUND LANYARD FOULED GIRT BAR. REMOVED AND STOWED AS REQD. OPS NRML, REF B757 AMM 52-11. (7137148)
- 26 Mar 2025
Sensor, out of limits
SHIP 5811 R AFT ENTRY DOOR EICAS MESSAGE WITH ASSOCIATED DOORS LIGHT WAS INTERMITTANTLY APPEARING WHILE ON DESCENT AND ON APPROACH. CORRECTIVE ACTION:…
- 10 Mar 2025
Girt Bar, fod
SHIP 5811 L4 WILL NOT ARM. CORRECTIVE ACTION: RMVD DEBRIS FROM GIRT BAR MOUNTS OPS CK GOOD. (6529284)
- 9 Feb 2025
Bottle, low
SHIP 5811 ON SVC CVK FOUND AFT LIFE RAFT LOW PSI. CORRECTIVE ACTION: R/R AFT LIFE RAFT IAW B757 AMM 25-64. (6836362)
- 9 Dec 2024
Indicator, out of adjust
SHIP 5811 4R DOOR WILL NOT FULLY ARM. CORRECTIVE ACTION: T/S PER B757 FIM 52-11-20-825-001. CLEARED OBSTRUCTION IN GIRT BAR PATH AND ADJUSTED 4R DOOR KNUCKLE…
- 27 Nov 2024
Sign, missing
SHIP 5811 RIGHT OVERWING HORIZONTAL EXIT SIGN IS MISSING. CORRECTIVE ACTION: INSP AND FOUND THE FWD LENS TABS BROKEN. REPLACED THE RIGHT OVERWING EXIT SIGN…
- 20 Nov 2024
Indicator, malfunctioned
SHIP 5811 4R DOOR LEVER NOT ENGAGING COMPLETELY FOR DISARM AND KNUCKLE KNOCKER NOT FULLY ENGAGING. CORRECTIVE ACTION: THAWED DOOR 4R. PERFORMED…
- 7 Nov 2024
Girt Bar, out of limits
SHIP 5811 A.D. A.A. L4 DOOR GIRT BAR OUT OF LIMITS PER AMDS 2561-01257-01E STEPS 12 AND 14. CORRECTIVE ACTION: SUMMARY OF NRC 00019: GIRT BAR AT L4 DOOR WAS…
- 6 Nov 2024
Slide, unlaced
SHIP 5811 UNLACED LEFT OVERWING SLIDE FUS. CORRECTIVE ACTION: SUMMARY OF NRC 00111: LH OVERWING SLIDE WAS REPLACED UNDER AMDS 5200-8346 AND SCEPTRE LOG.…
- 6 Nov 2024
Girt Bar, out of limits
SHIP 5811 A.D. A.A. R1 DOOR GIRT BAR OUT OF LIMITS PER AMDS 2561-01257-01B STEPS 12 AND 14. CORRECTIVE ACTION: SUMMARY OF NRC.00018: GIRT BAR AT R1 DOOR WAS…
- 5 Nov 2024
Strap, cracked
SHIP 5811 CRACK STABILIZER STRAP STA. 377 AND LBL 24 AT E/E COMPARTMENT CEILING AREA. CORRECTIVE ACTION: SUMMARY OF NRC 00225: STABILIZER STRAP STA. 377 AND…
- 4 Nov 2024
Girt Bar, out of limits
SHIP 5811 A.D. A.A. L2 DOOR GIRT BAR OUT OF LIMITS PER AMDS 2561-01257-01C STEPS 12 AND 14. CORRECTIVE ACTION: SUMMARY OF NRC 00021: GIRT BAR AT L2 DOOR WAS…
- 4 Nov 2024
Girt Bar, out of limits
SHIP 5811 A.D. A.A. R2 DOOR GIRT BAR OUT OF LIMITS PER AMDS 2561-01257-01D STEPS 12 AND 14. CORRECTIVE ACTION: SUMMARY OF NRC 00020: GIRT BAR AT R2 DOOR WAS…
- 17 Aug 2024
Cover, detached
SHIP 5811 PLASTIC EMER DOOR EXIT SIGN COVER FELL OFF. RIGHT SIDE AIRCRAFT. CURRENTLY IN OVERHEAD BIN. CORRECTIVE ACTION: REINSTALLED EMER DOOR EXIT SIGN COVER…
- 3 Aug 2024
Fuel Control, fluctuates
SHIP 5811-DIV/DE- DIVERSION TO PHX DUE TO LEFT ENGINE EPR AND N1 FLUCTUATION UNABLE TO CONTROL WITHOUT REDUCED THRUST. CORRECTIVE ACTION: REPLACED FUEL…
- 22 Jul 2024
Transmission, faulted
SHIP 5811 -FCNT/DE- DUE TO FLAP LOCK OUT ON APPROACH. CORRECTIVE ACTION: T/S FOUND RT AND LT O/B TORQUE LIMITER POPPED. R/R #8 FLAP SKEW SENSOR, R/R RT AND LT…
- 26 Jun 2024
Indicator, inoperative
SHIP 5811 2L DOOR ESCAPE SLIDE ARMED CONDITION INDICATOR (KNUCKLE KNOCKER) INOP CORRECTIVE ACTION: ADJUSTED 2L DOOR LOWER LINING PER B757 AMM 52-11. OPS CHECK…
- 8 May 2024
Light, inoperative
ON SERVICE CHECK FOUND OVERHEAD EMERGENCY LIGHT 32D INOP. CORRECTIVE ACTION: R/R CONNECTOR IAW B757 WDM 33-51 OPS CHECK GOOD.
- 8 Jan 2024
Unknown, unknown
SHIP 5811 BEFORE PUSHBACK R FWD ENTRY DOOR WOULD NOT CLOSE AND ARM. CORRECTIVE ACTION: CYCLED DOOR, NO TROUBLE FOUND. (8392930)
- 1 Nov 2023
Unknown, unknown
SHIP 5811 -MISC/DE- DUE TO LEADING EDGE SLAT DISAGREE ON APPROACH. CORRECTIVE ACTION: COMPLETED FIM TASK, CLEARED FAULTS, FLAPS/SLATS OPS CHECK COMPLETED.
- 18 Oct 2023
Unknown, unknown
SHIP 5811 FIRST CLASS MONITORS AT SEATS 1 C&D, 2 C&D, AND 3 C&D FAILED. AN ELECTRICAL BURNING SMELL WAS OBSERVED WHICH QUICKLY DISSAPATED. CORRECTIVE ACTION:…
- 27 May 2023
Unknown, unknown
SHIP 5811 EXIT SIGN ON BACK OF OVERHEAD SIGN MISSING NEAR DOOR 3 L/R. CORRECTIVE ACTION: RE-ATTACHED EXIT SIGN NEAR DOOR 3. OPS CK NML. (4745612)
- 27 Apr 2023
Unknown, unknown
SHIP 5811 LEFT AFT OVERWING EMERGENCY EXIT COVER LOOSE CAUSING LOUD VIBRATION AND CUSTOMER CONCERNS. CORRECTIVE ACITON: RESECURED LOOSE EMERG EXIT SIGN COVER…
- 24 Jan 2023
Frame, cracked
SHIP 5811 A.A. A.D. CRACKS ON BS 1640 FUSELAGE FRAME LEFT AS FOLLOW: ON UPPER OUTBOARD HOLE OF OUTER CHORD AND FRAME AT 03:00 AND 9:00 O CLOCK POSITION, ON…
- 24 Jan 2023
Skin, gouged
GOUGE ON UPPER SKIN AT LH HORIZONTAL STABILIZER BETWEEN STA128.248/STA152.248 AND REAR SPAR. GOUGE ON UPPER SKIN AT LH HORIZONTAL STABILIZER BETWEEN…
- 23 Jan 2023
None, none
SHIP 5811 DTE, ERA 605415-14, MONITOR INSPECTION LOG REPAIR TO LH HORIZONAL STABILIZER UPPER SKIN, AT STAB STA 128 AND S2. CORRECTIVE ACTION: REF ERA 605415-14.
- 22 Jan 2023
None, none
SECTION II REPAIR TO LH WING DRY BAY BARRIER AT WSTA 258.65- 313.50 REQUIRES SECTION III REPAIR WITHIN 24 MONTHS PER ERA 588939-14 REV A. REV ERA 588939-14…
- 21 Jan 2023
Snubber, out of limits
SHIP 5811 PERFORMING AMDS, ROTARY SNUBER PIN EXTENSION IS OUT OF LIMITS IN R4 DOOR. CORRECTIVE ACTION: SUMMARY OF NRC 00130: ROTARY SNUBBER 4R DOOR WAS…
- 20 Jan 2023
Girt Bar, unserviceable
SHIP 5811 AD RELATED: INITIAL INSPECTION: GIRT BAR LEAF SPRINGS 2 E/A DOES NOT RETAIN THE SLIDERS OF R2 DOOR (NEED REPLACE GIRT BAR PER AMM 25-66-10-201 AND…
- 20 Jan 2023
Snubber, inoperative
SHIP 5811 PERFORMING AMDS 2040-0191-2L STEP 7, ROTARY SNUBER PIN EXTENSION IS OUT OF LIMITS IN L2 DOOR. CORRECTIVE ACTION: SUMMARY OF NRC 00129: ROTARY…
- 19 Jan 2023
Skin, gouged
SHIP 5811 GOUGE AND DENT BTW STA 740 & STA 760 AND STR -15L & STR-16L ON EXTERNAL FUSELAGE SKIN. CORRECTIVE ACTION: SUMMARY OF NRC 00030: GOUGE AND DENT BTW…
- 15 Jan 2023
Leaf Spring, damaged
GIRT BAR LEAF SPRINGS 2 E/A DOES NOT RETAIN THE SLIDERS OF R4 DOOR (NEED REPLACE GIRT BAR IAW AMM 25-66-10-201 AND PERFORM CARD INSTRUCTIONS. R2 DOOR GIRT BAR…
- 14 Jan 2023
Snubber, out of limits
PERFORMING AMDS 2040-0191-1L, ROTARY SNUBER PIN EXTENSION IS OUT OF LIMITS IN L1 DOOR. ROTARY SNUBBER 1L DOOR WAS REPLACED PER AMM 52-11-10 AND PASSENGER DOOR…
- 12 Jan 2023
Strap, cracked
CRACK ON STABILIZATION STRAP STA 365 BL 0 AT NLG WHEEL WELL UPPER AREA. CORRECTIVE ACTION: SUMMARY OF NRC 00189: STABILIZATION STRAP WAS REPAIRED PER B757-…
- 6 Jan 2023
Intercostal, corroded
SHIP 5811 REFERENCE ER/A 596280-14 B757-300 / FUSELAGE / STA 1540 - 1560 / STR 27R TO 29R / LAV PAN INTERCOSTAL / CORROSION. CORRECTIVE ACTION: REF ERA…
- 9 Aug 2022
Cover, broken
SHIP 5811 RT AFT OVER WING EXIT COVER BROKEN AND WILL NOT STAY IN PLACE. CORRECTIVE ACTION: REPLACED HANDLE COVER ASSY PER B757 AMM 52-22. (8239198)
- 30 Jun 2022
None, none
SHIP 5811 MID CABIN EXIT SIGN FELL OFF. CORRECTIVE ACTION: RE-ATTACHED EXIT SIGN LENS. (8846790)
- 2 May 2022
Girt Bar, misaligned
SHIP 5811 4R-SLIDE LIGHT WILL NOT LIGHT WHEN IN ARM POSITION. CORRECTIVE ACTION: HAD TO ADJUST AND REALIGN GIRT BAR INTO PROPER POSITION PER B757 AMM 25-66.…
- 2 Apr 2022
None, none
SHIP 5811 AFT SIDE OF 3 DOOR HANGING EXIT SIGN FELL OFF. CORRECTIVE ACTION: REATTACHED EXIT COVER LENS AS REQUIRED. (8146699)
- 9 Feb 2022
None, none
SHIP 5811 REPAIR TO LH WING UPPER SKIN COMMON TO DRAG FITTING ATTACHMENT REQUIRES SUPPLEMENTAL INSPECTIONS PER ERA 589116-14 REV A. CORRECTIVE ACTION: REF ERA…
- 31 Dec 2021
None, none
SHIP 5811 ON WAKE UP WALK AROUND FOUND AFT LAV SERVICE PANEL CORROSION AROUND OUTER EDGE POPPING THRU SEALER AND PAINT. CORRECTIVE ACTION: REPAIRED PER ERA…
- 30 Dec 2021
None, none
SHIP 5811 CORROSION FOUND ON INTERCOSTAL ON TOP OF LAV PAN IN THE FWD INBD CORNER. THREE SPOTS. CORRECTIVE ACTION: SUMMARY SEE NR FOR ADDITIONAL INFORMATION…
- 30 Dec 2021
None, none
SHIP 5811 CORROSION DAMAGE DISCOVERED COMMON TO THE FUSELAGE SKIN IN THE VICINITY OF THE AFT LAVATORY SERVICE PANEL CUT-OUT. FUSELAGE SKIN REPAIR ADDRESSED IN…
- 22 Dec 2021
None, none
SHIP 5811 EMERGENCY BATTERY PACK FAILS DEEP CYCLE TEST. CORRECTIVE ACTION: REMOVED AND REPLACED EMERGENCY BATTERY PACK M00730 BATTERY PER B757 AMM 33-51-07…
- 9 Dec 2021
None, none
SHIP 5811 DOOR 2R DOSE NOT SHOW SLIDE LIGHT ILLUMINATED WITH DOOR ARMED. CORRECTIVE ACTION: CYCLED SLIDE ARM LEVER. SLIDE LIGHT INOP. OPENED DOOR WITH SLIDE…
- 5 Nov 2021
None, none
SHIP 5811 EMERGENCY EXIT COVER DIFFUSER LENS DAMAGED OR MISSING / LOCATIONS:655. CORRECTIVE ACTION: REINSTALLED EMERGENCY EXIT SIGN OPS CHECK OK. (2007423)
- 26 Sep 2021
None, none
SHIP 5811 4R DOOR WONT ARM AT DEPT. CORRECTIVE ACTION: RESECURED GIRT BAR OPN NOW CHECKS GOOD PER B757 AMM 52-11. (7767374)
- 30 Aug 2021
Light, unsecure
SHIP 5811 EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATIONS:14D. CORRECTIVE ACTION: EMER LIGHT AT 14D CHECKS GOOD.. FOUND LOOSE EMER LIGHT ASSY AT…
- 12 Aug 2021
Circuit Breaker, tripped
SHIP 5811 B R-34 "GRIT BAR ENT DIM" POP. CORRECTIVE ACTION: REMOVED AND REPLACED C/B. T/S PER B757 WDM 25-66-11, FOUND 1R SLIDE ARM IND LIGHT SORTED AT L404.…
- 14 Jun 2021
Light, inoperative
SHIP 5811 SLDE LIGHT 1L DOES NOT ILLUMINATE. CORRECTIVE ACTION: T/S PER B757 WDM 25-66 FOUND S10215 BAD RPLCD SAME CKS GOOD. (7601777)
- 7 May 2021
Guide, missing
SHIP 5811 R4 DOOR GIRT BAR MISSING GUIDE. CORRECTIVE ACTION: INSTALLED NEW GIRT BAR LOCK REF 757 AMM 25 66.
- 17 Apr 2021
Static Wick, damaged
SHIP 5811 STATIC DISCHARGBE RT WINGLET T/E 34" UP FROM ATTACH POINT. CORRECTIVE ACTION: PERFORMED BLEND OUT REPAIR IN ACCORDANCE WITH BOEING 757 SRM AND APPLY…
- 17 Apr 2021
Skin, damaged
SHIP 5811 BURNED RIVET AT FS 230, A/C RIGHT, 5" OUTBOARD FROM BLO, 2" FWD OF FWD ELECRICAL BAY. CORRECTIVE ACTION: BLENDED PNL PER 757 SRM. (1784240)
- 15 Mar 2021
Switch, faulted
SHIP 5811 R1 DOOR SLIDE LIGHT WILL NOT EXTINGUISH. CORRECTIVE ACTION: R/R BOTH FWD AND AFT GIRT BAR SWITCHES PER B757 WDM 25-66. (7387303)
- 15 Feb 2021
Ground Wire, unsecure
SHIP 5811 EMERGENCY LIGHTS ARE ROW 33-40 ARE INOPERATIVE. MAINTENANCE FOUND GROUND WIRE WITH POOR CONNECTION AND SECURED GROUND WIRE. SYSTEM OPERATION IS…
- 9 Feb 2021
Battery Pack, inoperative
EMERGENCY AISLE LIGHT ARE INOPERATIVE AT ROWS 33-40. MAINTENANCE REPLACED THE BATTERY PACKS. SYSTEM OPERATION IS NORMAL.(LP 6292575)
- 27 Dec 2020
Skin, corroded
DURING REMOVAL OF FASTENERS, ELONGATE HOLES AND BULGED SKIN WERE FOUND BETWEEN STA 660 TO 6680, BETWEEN S-27R TO 27L AT OUTER FUSELAGE SKIN. REPAIRED PER ERA…
- 24 Dec 2020
Skin, damaged
SHIP 5811 ERA 589133-14 ISSUED FOR REPAIR TO STA 660-680, S-28L TO S-28R. ENLONGATED HOLES / DENTS. CORRECTIVE ACTION: REF ERA 589133-14. (1686644)
- 23 Dec 2020
Structure, scratched
DURING INSPECTION MAINTENANCE FOUND SCRATCH ON DRY BAY (INNER FACE OF SETTLEMENT AREA) IN LT MAIN FUEL TANK BETWEEN WS 285.65/WS 313.50. REPAIRED PER ERA…
- 23 Dec 2020
Retainer, corroded
FOUND DURING INSPECTION CORROSION ON RETAINER PLATE OF GIRT BAR AT LIDES L1 AND L4. CORRECTIVE ACITON: RETAINER PLATE REPLACED.
- 18 Dec 2020
Floor Support, corroded
DURING INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRINGERS, RBL 7.55 AT STA 1333, STA 1362, STA 1374, RBL 10.45 AT STA 1360, STA 1371…
- 17 Dec 2020
Floor Support, corroded
DURING INSPECTION CORROSION LEVEL 2 WAS FOUND ON FLOOR STRINGERS LBL 2.90, 7.55 AND 10.45, STA 1510 AT AFT CARGO COMPARTMENT. MAINTNENACE REPAIRED, PER SRM.
- 17 Dec 2020
Floor Support, corroded
DURING INSPECION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS LBL 2.90, 7.55, 10.45 16.10, STA. 1470 AT AFT CARGO COMPARTMENT. STRINGER REPAIRED,…
- 16 Dec 2020
Floor Support, corroded
INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR SUPPORT NEXT TO FLOOR STRINGER 10.45 RBL FROM STA 1460/1480 AT AFT CARGO COMPARTMENT. FLOOR…
- 16 Dec 2020
Panel, corroded
DURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON RT SIDE PANEL (UPPER AND LOWER SURFACE), BETWEEN STA 1440 TO 1520 AT AFT CARGO COMPARTMENT.…
- 16 Dec 2020
Floor Support, corroded
REWRITE DUE TO MEASUREMENTS OF THE FLOOR STRINGERS ARE INCORRECT. CORROSION LEVEL 2 ON FLOOR STRINGERS RBL 2.90, 7.55, 10.45 16.10, STA 1470 AT AFT CARGO…
- 16 Dec 2020
Fitting, corroded
DURING INSPECTION MAINTENANCE FOUND CORROSION ON FLOOR FITTING ON G4. FITTING REPLACED PER ERA.
- 14 Dec 2020
Floor Support, corroded
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGER RBL 7.55 STA 1510 AT AFT CARGO COMPARTMENT. REPAIRED PER SRM 53-00-53.
- 11 Dec 2020
None, none
SHIP 5811 ERA 588939-14 ISSUED FOR LH WING DRY BAY REPAIR AT WING STATION 258.65-313.50. CORRECTIVE ACTION: REF ERA 588939-14. (1676433)
- 10 Dec 2020
Panel, corroded
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON LT SIDE PANEL AT AFT CARGO COMPARTMENT FROM STA 1420/1440. REPLACED SIDE PANEL PER SRM.
- 8 Dec 2020
Web, damaged
DURING INSPECTION, MAINTENANCE FOUND HIDDEN DAMAGE ON WEB OF INTERCOSTAL BETWEEN STA 1500 TO STA 1500 TO 1520 BL 0 PASSENGER CABIN. REPAIRED PER SRM 51-70-13.
- 7 Dec 2020
Floor Support, corroded
DURING INSPECTION, MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRUCTURE OF PASSENGER CABIN. REPAIRED PER SRM.
- 7 Dec 2020
Floor Support, corroded
DURING INSPECTION, FOUND CORROSION LEVEL 2 ON FLOOR STRUCTURE OF PASSENGER CABIN BETWEEN STA 980 AND 1020 AND RBL 64.5 AT WING CENTER AREA. CORROSION REPAIRED…
- 6 Dec 2020
Intercostal, corroded
DURING INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON INTERCOSTAL BETWEEN STA 600 AND 620 AND BETWEEN S 26R AND 27R AT FWD CARGO COMPARTMENT.…
- 2 Dec 2020
Floor Support, corroded
DURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON LIMITS ANGLE FLOOR SUPPORT FROM STA 1596 TO 1602 AND 64 RBL PASSENGER CABIN. REPAIRED PER SRM.
- 28 Nov 2020
Strap, cracked
DURING INSPECTION MAINTENANCE FOUND A CRACK ON STABILIZER STRAP LBL 25, STA 365 AT PASSENGER FLOOR STRUCTURE. CRACK REPAIRED PER SRM.
- 28 Nov 2020
Strap, cracked
DURING INSPECTION MAINTENANCE FOUND A CRACK ON STABILIZER STRAP STA 1620 AND 45 RBL AT PASSENGER CABIN FLOOR STRUCTURE AND REPAIRED, PER SRM.
- 28 Nov 2020
Strap, cracked
DURING INSPECTION MAINTENANCE FOUND A CRACK ON STABILIZER STRAP STA 1640 AND 25 LBL AT PASSENGER CABIN FLOOR STRUCTURE. CRACK REPAIRED PER SRM.
- 27 Nov 2020
Strap, cracked
DURING INSPECTION FOUND CRACK ON STABILIZER STRAP STA 1661 AND 25 RBL AT PASSENGER CABIN FLOOR STRUCTURE. STRAP REPAIRED, PER SRM 53-00-51.
- 8 Jul 2020
Indicator, out of adjust
R4 DOOR KNUCKLE KNOCKER ARMED IN DICATION NOT PROPERLY RETRACTING AND EXTENDING PER PILOT AND FA PROCEDURES. ADJUSTED THE KNUCKLE KNOCKER, CHECKS NORMAL IAW…
- 6 Jul 2020
Reservoir, low pressure
DURING A SERVICE CHECK, FOUND THE L2 DOOR EMP POWER RESERVOIR EMPTY. REMOVED AND REPLACED L2 DOOR ASSIST RESERVOIR ASSY IAW AMM 52-11-30. PRESSURE CHECKED GOOD.
- 28 Jun 2020
Battery Pack, discharged
EMERGENCY LIGHTS INOP AT L4 DOOR AND ROWS 46-49. R/R BATTERY PACK AT M737 PER AMM 33-51. OPS CHK GOOD.
- 26 Mar 2020
Warning System, false activation
SHIP 5811 RECEIVED L CTR ENT DOOR EICAS MESSAGE. REFERENCED QRH. CORRECTIVE ACTION: PERFORMED DOOR CHECK ON 2L REF B757AMM 52-11. DOOR OPERATES AND INDICATES…
- 11 Feb 2020
Bypass Valve, leaking
SHIP 5811 -FUME- A OILY DIRTY SOCK ODOR WAS REPORTED IN THE COCKPIT AND CABIN, O2 MASKS WERE DONNED. CORRECTIVE ACTION: FOUND SLAT BYPASS VALVE LEAKING INTO…
- 31 Jan 2020
Battery Pack, inoperative
SHIP 5811 SEAT 28E LOWER EMERGENCY EXIT SIGN INOP. CORRECTIVE ACTION: FOUND BATTERY PACK EQUIPMENT # M11384 DEAD R/R BATTERY PACK IAW B757 AMM 33-51. OPS NML.…
- 29 Dec 2019
Battery Pack, inoperative
EMERGENCY EXIT LIGHTS INOPERATIVE AT SEATS 24 - 26DEF, BINS 34, 42 AND 44, OVERWING EXITS, AND EXIT. R & R TWO BATTERY PACKS FOR EMERGENCY LIGHTING IAW AMM…
- 29 Nov 2019
Fuse, failed
SHIP 5811 EMER LIGHTS INOP ROWS 46-49. CORRECTIVE ACTION: REPLACED FUSE POWER SUPPLY M737 REF B757 WDM 33-51-22 AND B757 AMM 33-51-07-962-017-002. OPS GOOD.…
- 10 Oct 2019
Battery Pack, no test
EMERGENDCY LIGHT POWER SUPPLY BATTERY PACKS M11613 AND M11487 WILL NOT KEEP EMERGENCY LIGHTS ILLUMINATED FOR AT LEAST 15 MINS. REPLACED THE BATTERY PACKS. OK…
- 22 Sep 2019
Cap, defective
(AIRCRAFT 5811, L/P 1282803) SLIDE INDICATOR LIGHT INOP OR DAMAGED / LOCATIONS: 4R. 4R SLIDE LIGHT WAS ON BUT TURNING OFF AFTER TAKEOFF EVEN THOUGH DOOR WAS…
- 20 Sep 2019
Engine, making metal
SHIP 5811- IFSD & DIV - AIRCRAFT DIVERTED INTO DEN DUE TO PILOT REPORT OF RIGHT ENGINE STALL THEN ROLL BACK TO IDLE. ENGINE SUBSEQUENTLY SHUT DOWN. CORRECTIVE…
- 20 May 2019
Sensor, defective
SHIP 5811 -DIV- DIVERED TO DEN DUE TO LEFT ENGINE BLEED OFF LIGHT AND EICAS MESSAGE AT FL 360 AND ENGINE ANTI-ICE ON. FOLLOWED QRH AND RECEIVED RIGHT ENGINE…
- 16 May 2019
Power Supply, inoperative
(AIRCRAFT 5811, L/P 5646771) DURING SVC CK FOUND EMERGENCY BATT POWER SUPPLY M11383 INOP. R/R PWR SUPPLY & BATTERY POS M11383 REF AMM 33-51. OPS NML.
- 16 Mar 2019
Angle, damaged
SHIP 5811 LWR AFT T-ANGLE ON RT HORIZONTAL STAB DAMAGED 30" IB FROM O/B EDGE. CORRECTIVE ACTION: REPAIRED PER ERA 576304-14 REV A. (5818719)
- 3 Jan 2019
Lens, missing
SHIP 5811 EMERGENCY EXIT SIGN LENS MISSING AT ROW 38. CORRECTIVE ACTION: REPLACED LENS, CKS OK PER AMM 33-51. (5280258)
- 7 Nov 2018
Pin, broken
(AIRCRAFT 5811, L/P 0817270) L-4 DOOR EMERGENCY EXITSLIDE HAS LACING PIN DAMAGED/ BROKEN. DOT 004. I-29. REMOVED AND REPLACED L-4 DOOR EMERGENCY ESCAPE SLIDE…
- 22 Jun 2018
Engine, malfunctioned
LEFT ENGINE POPPING NOISE REPORTED BY TOWER AND OTHER AIRCRAFT. INSPECTED BOTH ENGINE INLETS AND OUTLETS, MASTER CHIP DETECTORS AND MCD'S IAW AMM 79-21- NTF.…
- 18 Oct 2017
Lamp, inoperative
ROW 30 AND 33 OVERHEAD BIN MOUNTED EMERGENCY LIGHTS INOPERATIVE. REPLACED THE LAMPS. OPS CHECKED GOOD. OK FOR SERVICE.
- 2 Sep 2017
Fuse, tripped
LEFT OVERWING DOOR EMERGENCY LIGHTS INOPERATIVE. FOUND THE FUSE TRIPPED ON THE PSU, AFTER REPLACING FUSES ON PSU. FOUND SHORTED LIGHT BULB HANDLE LIGHT IAW…
- 31 May 2017
Light, detached
EMERGENCY LIGHT AT 48 D IS DETACHED. INSTALLED NEW BRACKET. OK FOR SERVICE.
- 17 May 2017
Gasket, leaking
ENROUTE, AIRCRAFT LOST THE RT HYD QTY FLUID. DURING APPROACH WITH FLAPS AT 30, THE AIRCRAFT EXPERIENCED A ROLL TO THE LEFT. CREW DID A GO AROUND, EXTEND THE…
- 16 Apr 2017
Wire, broken
EMERGENCY LIGHT AT ROW 33D INOPERATIVE. FOUND A WIRE BROKEN UNDER SEAT. REPAIRED IAW SWPM 20. OPS CHECKED GOOD. OK FOR SERVICE.
- 6 Mar 2017
Sign, missing
BACK SIDE OF CENTER AISLE OVERHEAD "EXIT SIGN MISSING BY ROW 38. REPLACED MISSING OVERHEAD EXIT SIGN AT ROW 38.
- 2 Mar 2017
Light, inoperative
DURING A SERVICE CHECK, FOUND EMERGENCY LIGHT INOPERATIVE AT ROW 43. REMOVED AND REPLACED THE LIGHT ASSY IAW AMM 33-50. OPS CHECKED GOOD.
- 12 Jan 2017
Wire, broken
FLOOR PATH EMERGENCY LIGHTS ARE INOP AT SEATS 14 DEF TO 20 DEF. INSP AND FOUND EMERGENCY LIGHT WIRING BROKEN UNDER SEAT ROW 20 DEF. REPAIRED WIRING UNDER…
- 10 Nov 2016
Housing, damaged
SEAT 35 RT EEPLS HOUSING DAMAGED. R&R SEAT 35 RT EEPLS HOUSING OK FOR SERVICE.
- 6 Jun 2016
Light, broken
EMERGENCY LIGHT UNDER 42D BROKEN. SEAT 42D UNDERSEAT EMERGENCY ESCAPE PATH LIGHT IS OPERATIVE BUT LIGHT ASSY BROKEN. TEMPORARILY SECURED IN PLACE WITH…
- 10 May 2015
Power Supply, inoperative
DURING ACFT SERVICE CHECK, FOUND EMERGENCY LIGHTING INOPERATIVE AT ROWS 33-36, 37-39. FOUND POWER SUPPLY AT FS 1334 OVERHEAD INOPERATIVE 1 OF 2. ABOVE CEILING…
- 15 Feb 2015
Engine, making metal
DURING FLIGHT, DIVERTED DUE TO RT ENGINE OIL FILTER EICAS MESSAGE. INDICATION DID NOT EXTINGUISH WITH THROTTLE AT IDLE. ENGINE WAS SHUTDOWN IAW QRH.…
- 9 Nov 2014
Stringer, cracked
CRACK ON END OF STRINGER 16L AT BS 780+36 RG3. REPAIRED STRINGER IAW ER/A 528685-14, REV ORIGINAL.
- 9 Nov 2014
Stringer, cracked
CRACK ON END OF STRINGER 16R AT BS 780+36 RG1. REPAIRED STRINGER IAW ER/A 515773-14, REV ORIG.
- 6 Nov 2014
Structure, punctured
PREVIOUS REPAIR HAS A VOID IN SEALANT ON THE LT WING OTBD AFT FLAP LOWER SURFACE AT APPROXIMATELY STA 537. REPAIRED HONEYCOMB PUNCTURE DAMAGE, PERFORMED WATER…
- 5 Nov 2014
Crease Beam, corroded
CORROSION ON RT MAIN CABIN CREASE BEAM INNER ANGLE AT BS 1260. REPAIRED IAW ERA 529963-14, REV-ORIG.
- 5 Nov 2014
Cable, out of adjust
DOOR FAILED EMERGENCY POWER ACTUATION CABLE TRAVEL CHECK. ADJUSTED EMERGENCY POWER ACTUATION CABLE IAW AMM 52-11.
- 4 Nov 2014
Girt Bar, no test
R1 DOOR FORWARD FLOOR FITTING ON GIRT BAR FAILED GO-NO-GO TEST. R & R R-1 DOOR GIRT BAR.
- 3 Nov 2014
Stringer, corroded
CRACK ON END OF STRINGER 16R BS 780+24. REMOVED, FABRICATED AND INSTALLED STRINGER SECTION AT STRINGER IAW SRM.
- 2 Nov 2014
Strap, cracked
FWD CARGO BAY CEILING STABILAZATION STRAP LBL 25 IS CRACKED AT BS 580. CEILING STABILIZATION STRAP REPAIRED IAW ERA 384483-14 REV.-D.
- 2 Nov 2014
Stringer, cracked
CRACK ON END OF STRINGER 16L AT BS 780+24. REMOVED, FABRICATED AND INSTALLED NEW STRINGER IAW SRM.
- 2 Nov 2014
Strap, cracked
FWD CARGO CEILING STABILIZER STRAP RBL 25 IS CRACK AT BS 700. REPAIRED IAW ERA 384483-14 MA REV-D.
- 2 Nov 2014
Crease Beam, corroded
CORROSION ON THE RIGHT CREASE BEAM INNER ANGLE BETWEEN BS 730 TO 740. REMOVED CORROSION AND FOUND OUT OF LIMITS. R & R CREASE BEAM IAW SRM.
- 2 Nov 2014
Seat Track, corroded
CORROSION ON MAIN CABIN SEAT TRACK BS 377.7, LBL 071 94. FOUND OUT OF LIMITS IN IAW SRM. R & R SEAT TRACK SUPPORT.
- 29 Oct 2014
Angle, cracked
FWD CARGO DOOR INTERNAL STRUCTURES HAS UPPER ANGLES CRACKED ON FWD AND AFT CORNERS 97-09. FABRICATED AND INSTALLED 2EA UPPER ANGLES ON FWD CARGO COMPARTMENT…
- 28 Oct 2014
Seat Track, corroded
CORROSION ON MAIN CABIN SEAT TRACK AT BS 1640, RBL 46. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS. R & R THE SEAT TRACK IAW SRM.
- 24 Oct 2014
Strap, cracked
FWD NOSE COMPARTMENT LT TUNNEL CEILING STABILIZATION STRAP IS CRACKED AT LBL 46 BS 365. REPAIRED THE STRAP IAW ER/A 384483-14MA, REV D.
- 24 Oct 2014
Seat Track, misaligned
SEAT TRACK SPLICE AT BS 1600, FOUND MISMATCH CONDITION RBL 24, RBL 45 AND LBL24 AND LBL 45. REPAIRED THE SEAT TRACK MISMATCH CONDITION IAW ER/A 528656-14 REV…
- 11 Oct 2014
Battery Pack, no test
BATTERY PACK DID NOT POWER LIGHTS FOR 15 MINUTES. R & R BATTERY PACK IAW AMM 33-51.
- 13 Jul 2014
Lens, missing
EXIT ROW SEAT 26C RED LENS MISSING. R & R EMERGENCY LIGHT ASSY.
- 8 Feb 2014
Wire, broken
SEAT ROWS 14-20 EMERGENCY LIGHTS INOPERATIVE. WIRE BROKEN FOUND. REPAIRED WIRE IAW WSPM 20-30. OPS CHECKED OK.
- 10 Dec 2013
Wire, damaged
BOTH EMERGENCY LIGHT MODULES ON SEAT 25C INOPERATIVE. FOUND BROKEN SPLICE ON HARNESS. REPAIRED SPLICE IAW SWPM CHAP 20-30. BOTH LIGHT MODULES ON SEAT 25C, OPS…
- 5 Oct 2013
Bulb, inoperative
SEVERAL EMERGENCY PATH SEAT LIGHTS BURNED OUT. REPLACED BULB. OPS GOOD.
- 6 Jun 2013
Unknown, odor
CREW REPORTED ACRID ODOR IN THE CABIN AND COCKPIT. PILOTS FOLLOWED QRH AND ODOR WENT AWAY THEN ODOR RETURNED. FLIGHT DIVERTED AS A PRECAUTION. MX REMOVED LT…
- 25 Oct 2012
Support, cracked
FCB CEILING PANEL SUPPORT IS CRACKED BELOW BS 720 FLOORBEAM, LBL 24, WL 200. FCB CEILING PANEL SUPPORT IS CRACKED BELOW BS 720 FLOORBEAM, LBL 24, WL 200 C/W…
- 24 Oct 2012
Floor Support, cracked
MX DISCOVERED THE FLOOR SUPPORT CRACKED ON LOWER FLANGE AT AFT END OF BS 364.5 LBL 24. R & R CRACKED FLOOR SUPPORT AT BS 364.5, LBL 24, WL 206 IAW SRM 51-40-02.
- 12 Sep 2011
Connector, loose
DURING A SERVICE CHECK, MAINTENANCE FOUND THE EMERGENCY PATHLIGHT AT SEAT 23C INOPERATIVE. MAINTENANCE RESECURED THE CONNECTOR. OPERATIONAL CHECK WAS GOOD.
- 16 Oct 2010
Panel, delaminated
DURING L-CHECK FOUND DELAMINATION ON THE TOP SIDE OF PANEL 431AT. REPAIRED PER ERA 401869-14.
- 16 Oct 2010
Skin, damaged
DURING LINE CHECK FOUND DAMAGE TO FUSELAGE SKIN AT BS 305 S22R. REPAIRED PER ERA 486183-14 SECTION I, SECTION II OF ERA 486183-14 TO PER ACCOMPLISHED NO LATER…
- 15 Oct 2010
Skin Panel, cracked
DURING L-CHECK FOUND CRACK ON LEFT WING UPPER SURFACE FIXED LEADING EDGE PANEL OSS 438. REPAIRED PER ERA 483182-14.
- 14 Oct 2010
Skin Panel, damaged
DURING L-CHECK FOUND RIGHT WING FIXED LEADING EDGE SKIN PANEL BULGING AND CRACKED AT OSS 436. REPAIRED PER ERA 486181-14.
- 1 Sep 2010
Angle, cracked
PYLON TO FAIRING FIRESEAL ANGLE CRACKED JUST AFT OF AFT ENG MOUNT. VERIFIED WITH EDDY CURRENT (CRACKS BY 3 FASTENERS FROM OTBD END) REPLACED CRACKED ANGLE IAW…
- 1 Sep 2010
Support Angle, cracked
LT PYLON VERTICAL SUPPORT ANGLE ABOVE SKATE ANGLE CRACKED. R & R CRACKED ANGLE IAW SRM 51-10-02.
- 1 Sep 2010
Angle, cracked
PYLON TO FAIRING FIRESEAL ANGLE CRACKED JUST AFT OF AFT ENG MOUNT. VERIFIED WITH EDDY CURRENT (CRACKS BY 3 FASTENERS FROM OTBD END) REPLACED CRACKED ANGLE IAW…
- 27 Aug 2010
Brake Assy, fire
WHILE TAXIING INTO THE GATE, THE BELOW-THE-WING PERSONNEL NOTICED THAT THERE WERE FLAMES COMING FROM THE NR2 AND NR6 BRAKES. ACS EXTINGUISHED FIRE ON BRAKES…
- 22 Oct 2007
Brake Assy, fire
DURING ROLL UP TO GATE, NR 1 BRAKE CAUGHT FIRE AND THEN SPREAD TO NR 2 BRAKE. GROUND PERSONNEL USED FIRE EXTINGUISHERS TO EXTINGUISH THE FIRE. THERE WERE NO…
- 10 Dec 2005
Cartridge, inoperative
NR 1 LEFT OVERWING SLIDE SQUIB LIGHT INOP. FOUND SQUIB BLOWN, REPLACED SQUIB AND RETURNED AIRCRAFT TO SERVICE.
- 22 Sep 2004
Line, chafed
THE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE…