N590JB
2004 Airbus A320-232 standard FAA →
registration
- 2004
NTSB
- 26 Aug 2010
incident, Sacramento CA
service difficulty reports
62 reports
- 17 Sep 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: LOUD SQUEAL ON CLIMBOUT. DIFFICULT TO HEAR ATC; FOUND F/O SLIDING WINDOW SEAL TORN. REF STS NR0006 W/O003140.REMOVED AND REPLACED…
- 13 Nov 2022
Control Unit, failed
FLT # 48, TPA-LGA. SMOKE LAV SMOKE ECAM ON TAXI OUT MOC ADVISED RETURN TO GATE.; R/R SDCU IAW AMM 26-17-34, R/R AFT L/H LAV SMOKE DETECTOR IAW AMM 26-17-15.…
- 13 Nov 2022
Smoke Detector, failed
FLT # 48, TPA-LGA. SMOKE LAV SMOKE ECAM ON TAXI OUT MOC ADVISED RETURN TO GATE.; R/R SDCU IAW AMM 26-17-34, R/R AFT L/H LAV SMOKE DETECTOR IAW AMM 26-17-15.…
- 20 Feb 2021
Oil Cooler, leaking
FLT 733, MCO-SJU. DIRTY SOCK ODOR REPORTED BY FA'S FROM ROW 17 AND TOWARDS THE REAR OF THE AIRCRAFT. ODOR SMELLED DURING TAKEOFF AND DESCENT BELOW 10,000';…
- 6 Jan 2021
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION SEAT TRACK -Y 765 LOCATED BETWEEN FR 12-24 FWD GALLEY AREA. R & R SEAT TRACK -Y 765, REF AEROMAN NR 2020-383969 FOR DETAILS.
- 6 Jan 2021
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION SEAT TRACK +Y765 LOCATED BETWEEN FR 12-24. RESOLVED ON W/O: 1075575 TASKCARD: NR-00011. R & R SEAT TRACK +Y765, REF…
- 6 Jan 2021
Dummy Rail, corroded
DURING HEAVY MAINTENANCE, CORROSION RAIL DUMMY Y 503.2 LOCATED BETWEEN FR 12-16 FWD GALLEY AREA. R & R RAIL DUMMY Y 503.2, REF AEROMAN NR 2020-384008.
- 6 Jan 2021
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION SEAT TRACK -Y1292 LOCATED BETWEEN FWD GALLEY AREA. R & R SEAT TRACK -Y1292 LOCATED BETWEEN FR 12 TO FR 24 FWD GALLEY AREA,…
- 6 Jan 2021
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM +Y254 LOCATED FR 12-24 FWD GALLEY AREA. R & R FLOOR BEAM +Y254 LOCATED FR 12 TO FR 24 FWD GALLEY AREA, IAW A320…
- 6 Jan 2021
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION SEAT TRACK +Y1292 LOCATED BETWEEN FR 12-24 FWD GALLEY AREA. R & R SEAT TRACK +Y1292, REF AEROMAN NR 2020-383994.
- 6 Jan 2021
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM -Y464 FR 64-67 AT AFT GALLEY AREA. RESOLVED ON W/O: 1075575 TASKCARD: NR-00015. R & R FLOOR BEAM -Y464 LOCATED…
- 6 Jan 2021
Slide, inadequate
DURING HEAVY MAINTENANCE, IMPROPERLY PACKED SLIDE, DOOR 842 (HITS FUSELAGE WHEN OPEN), REF AEM NR 2020/159/1-2020-383866. R & R SLIDE RAFT 842, IAW A320 AMM…
- 6 Jan 2021
Slide, inadequate
DURING HEAVY MAINTENANCE, IMPROPERLY PACKED SLIDE, DOOR 831 (HITS FUSELAGE WHEN OPEN), REF AEM NR 2020-159/1-2020-383864. R & R SLIDE RAFT 831, IAW A320 AMM…
- 6 Jan 2021
Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION EXIT DOOR 844 FWD AND AFT INNER FRAME SEGMENTS, REF AEM NR 2020-159/1-2020-383896. ACCOMPLISHED MODIFICATION TO…
- 6 Jan 2021
Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION EXIT DOOR 833 FWD AND AFT INNER FRAME SEGMENTS, REF AEM NR 2020-159/1-2020-383897. ACCOMPLISHED MODIFICATION TO…
- 6 Jan 2021
Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION EXIT DOOR 843 FWD AND AFT INNER FRAME SEGMENTS, REF AEM NR 2020-159/1-2020-383898. ACCOMPLISHED MODIFICATION TO…
- 6 Jan 2021
Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION EXIT DOOR 834 FWD AND AFT INNER FRAME SEGMENTS, REF AEM NR 2020-159/1-2020-383899. ACCOMPLISHED MODIFICATION TO…
- 6 Jan 2021
Power Supply, no test
DURING HEAVY MAINTENANCE, EPSU 11WL FAILED OPERATIONS TEST, REF AEM NR 2020-159/1-2020-383782. PERFORMED TSM OF 11WL EPSU 33-51-00-810-801-A STEP 1-3A.…
- 6 Jan 2021
Floor Support, corroded
DURING HEAVY MAINTENANCE, REFERENCE AEROMAN NR 2020-383925. CORROSION FLOOR STRUCTURE WEB LOCATED FR 69 TO 70 AND STR 23R AT AFT GALLEY AREA. RESOLVED ON W/O:…
- 6 Jan 2021
Support, corroded
DURING HEAVY MAINTENANCE, REFERENCE AEROMAN NR 2020-383928. CORROSION LOWER SILL LOCATED FR 66 AT LEVEL STRINGER 23RT SIDE OF AFT GALLEY. RESOLVED ON W/O:…
- 6 Jan 2021
Web, corroded
DURING HEAVY MAINTENANCE, REFERENCE AEROMAN NR 2020-383921. CORROSION FLOOR STRUCTURE WEB LOCATED FR 69 TO FR 70 AND STR 23L AT AFT GALLEY AREA. RESOLVED ON…
- 17 Oct 2020
Power Supply, failed
FLT 92, TPA-BOS. RT EMERGENCY LIGHT OVERWING INOPERABLE (12WL). REMOVED AND REPLACED EPSU 12WL AND BATTERY PACK, IAW 33-51-38. OPERATIONS CHECK GOOD, NO…
- 17 Oct 2020
Battery, failed
FLT 92, TPA-BOS. RT EMERGENCY LIGHT OVERWING INOPERABLE (12WL). REMOVED AND REPLACED EPSU 12WL AND BATTERY PACK, IAW 33-51-38. OPERATIONS CHECK GOOD, NO…
- 17 Oct 2020
Epsu, failed
FLT 92, TPA-BOS. EMERGENCY LIGHTS IN CENTER CABIN INOPERABLE. FOUND EXPOSED AND SHORTED WIRES ON ESPU TO ROW 5 SEAT HARNESS (FIN 7260VC). REPLACED CONNECTOR…
- 16 Oct 2020
Power Supply, failed
FLT 91, BOS-TPA. OVERHEAD EXIT LIGHT INOPERABLE CENTER CABIN AND LEFT SIDE MID CABIN. R & R EMERGENCY LIGHT BATTERY AND PACK. OPERATIONS CHECKS OK, IAW…
- 16 Oct 2020
Battery, failed
FLT 91, BOS-TPA. OVERHEAD EXIT LIGHT INOPERABLE CENTER CABIN AND LEFT SIDE MID CABIN. R & R EMERGENCY LIGHT BATTERY AND PACK. OPERATIONS CHECKS OK, IAW…
- 16 Sep 2020
Epsu, failed
FLT 828 MCO-EWR. AFT EXIT LIGHTS INOPERABLE (AFT DOORS AND OVERHEAD). R & R EPSU AND EPSU BATTERY (AFT LEFT), PER AMM 33-51-38. OPS CK GOOD, OK FOR SERVICE.
- 1 Sep 2020
Epsu, failed
FLT 6459, MCO-TPA. (REF. PEMCO N/R 2906N156) EMERGENCY LIGHTS ABOVE R2 AND L2 INOP; (PER PEMCO N/R 2906N156) R & R EPSU AND EMERGENCY BATTERY IAW AIRBUS A320…
- 29 Jul 2020
Epsu, failed
FLT 560, WHILE T/S PROBLEM FOR EPSU FIN 11WL, SWAPPED EPSU ON RT SIDE FIN 12WL OVER TO LEFT SIDE. NO HELP, PLACED 12WL BACK IN NORMAL POSITION ON RT SIDE. NOW…
- 29 Jul 2020
Battery, failed
FLT 560, WHILE T/S PROBLEM FOR EPSU FIN 11WL, SWAPPED EPSU ON RT SIDE FIN 12WL OVER TO LEFT SIDE. NO HELP, PLACED 12WL BACK IN NORMAL POSITION ON RT SIDE. NOW…
- 29 Jul 2020
Epsu, failed
FLT 560, LEFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R EPSU (11WL) IAW AMM 33-51-38. R & R OVERWING AFT LIGHT ASSY IAW AMM 33-51-15. R & R AISLE EXIT SIGN…
- 29 Jul 2020
Battery, failed
FLT 560, LEFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R EPSU (11WL) IAW AMM 33-51-38. R & R OVERWING AFT LIGHT ASSY IAW AMM 33-51-15. R & R AISLE EXIT SIGN…
- 29 Jul 2020
Light, failed
FLT 560, LEFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R EPSU (11WL) IAW AMM 33-51-38. R & R OVERWING AFT LIGHT ASSY (63WL) IAW AMM 33-51-15. R & R AISLE…
- 27 Jan 2020
Epsu, no test
AFT LH EPSU FAILED DURING A CAPACITY TEST. R & R ESPU IAW AMM 33-51-58. OPS CHECK PASSED. ACFT OK FOR SERVICE.
- 25 Mar 2019
Lens, missing
FLT 1136, LGB-SFO. ON-FLIGHT CREW REPORTS EMER LIGHT LENS COVER MISSING AT 13C AISLE; REPLACED MISSING EMERG. LIGHT COVER AS REQUIRED. OPS CKS GOOD.
- 22 Jan 2019
Epsu, failed
FLT 857, HPN-PBI. FOUND LOWER EMERGENCY EXIT WALL LIGHTS AT OVERWING EXITS INOP; FOUND ESPU 12WL TO BE AT FAULT. R&R ESPU ASSY. OPS TEST NORMAL IAW AMM…
- 6 Nov 2018
Fan, failed
FT # 1234, SJU-FLL. DURING CRUISE WE RECEIVED A SMOKE LIGHT AND AURAL WARNING ON THE AFT AVIONICS COMPT PANEL; PERFORMED INSP FOR ELEC BURNING SMELL IN CABIN…
- 15 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM FROM FR 66 + 4" TO FR 67 + 16" BTW +Y1292 & +Y1162 AFT GALLEY AREA; REPLACED FLOORBEAM FROM FR…
- 15 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y317.9 BETWEEN FR 65 TO FR 67 AT AFT GALLEY AREA; REPLACED FLOORBEAM -Y317.9 BETWEEN FR 65 TO…
- 15 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM +Y1162 BETWEEN FR 67 + 16' TO FR 70 AT AFT GALLEY AREA; REPLACED FLOORBEAM +Y1162 BETWEEN FR…
- 15 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y1162 BETWEEN FR 67 + 16' TO FR 70 AT AFT GALLEY AREA; REPLACED FLOORBEAM -Y1162 BETWEEN FR…
- 15 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y 1292 FROM FR 64 TO FR 66 +4" AT AFT GALLEY AREA; REPLACED FLOORBEAM -Y1292 FROM FR 64 TO FR…
- 15 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM FROM FR 66 +4 " TO FR 67 + 16" BTW -Y1262 TO -Y1162 AT AFT GALLEY AREA; REPLACED FLOORBEAM…
- 15 Sep 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON HOLES SEAT TRACK -Y765 PAX CABIN AFT GALLEY AREA (1EA); REPLACED FLOORBEAM -Y765 BTW FR 64 TO FR 66 + 4"…
- 22 May 2018
Battery Pack, no test
EPSU BATTERY 12WL FAILED AN EMERGENCY LIGHT TEST. R & R THE BATTERY IAW AMM 33-51-38, SYSTEM OPS CHECKED NORMAL.
- 22 May 2018
Battery Pack, no test
EPSU BATTERY 11WL FAILED AN EMERGENCY LIGHT TEST. R & R THE BATTERY IAW AMM 33-51-38, SYSTEM OPS CHECKED GOOD.
- 22 May 2018
Battery Pack, no test
EPSU 10WL FAILED AN EMERGENCY LIGHT TEST. R & R THE BATTERY IAW AMM 33-51-38, SYSTEM OPS CHECKED NORMAL.
- 21 Sep 2017
Linkage, out of adjust
R2 DOOR SLIDE ARMED INDICATION GOES OFF AND ARMED WITH HANDLE IN THE ARMED POSITION. ARMING HANDLE DOES NOT FULLY STAY DOWN, BOUNCES UP SLIGHTLY FROM CLOSED…
- 8 Aug 2017
Battery, no test
AFT EMERGENCY LIGHT BATTERY (13WL) FAILED THE EMERGENCY LIGHT TEST. R & R AFT BATTERY IAW AMM 33-51-38, BATTERY AND EMERGENCY LIGHT SYSTEM TESTED OK.
- 17 May 2017
Engine, failed
CAPTAIN REPORTED AN ODOR IN THE COCKPIT AFTER TAKEOFF. THE ODOR DISSIPATED AND THEN REAPPEARED DURING DESCENT. NR 1 ENGINE REMOVED AND REPLACED. OPS CHECK…
- 10 Mar 2016
Epsu, failed
BOTH FRONT EXIT SIGNS DID NOT ILLUMINATE WHEN GEAR WAS EXTENDED; R & R EPSU FWD OVERHEAD LT SIDE AND BATTERY EMERGENCY UNIT IAW AMM 33-51-38. OPS CK SYS IAW…
- 10 Mar 2016
Battery, failed
BOTH FRONT EXIT SIGNS DID NOT ILLUMINATE WHEN GEAR WAS EXTENDED; R & R EPSU FWD OVERHEAD LT SIDE AND BATTERY EMERGENCY UNIT IAW AMM 33-51-38. OPS CK SYS IAW…
- 11 Jan 2016
Power Supply, failed
EMERGENCY EXIT SIGN OVER L1 DOOR WILL NOT ILLUMINATE. R & R EPSU IAW 33-51-18. OPS CHECKED NORMAL.
- 6 Dec 2013
Valve, leaking
CREW DECLARED AN EMERGENCY DUE TO Y HYD RESERVOIR LOW ECAM, Y HYD QTY DECREASED TO 2010 AND ACCUMULATOR PRESSURE BLED TO ZERO. R & R PARKING BREAK VALVE IAW…
- 9 May 2013
Power Supply, failed
FLT 780 MBJ-JFK, ON MAINTENANCE CHECK FOUND EMERGENCY LIGHT BATTERY LOW MESSAGE DURING CIDS TEST. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT PER…
- 30 Mar 2013
Sensor, dirty
FLT 796 SXM-BOS, AIRCRAFT DIVERTED TO SJU. CLIMBING THROUGH FL 320 COCKPIT AND CABIN BECAME EXCESSIVELY HOT TEMP EXCEEDING 94 DEG F. DESCENT THROUGH 6000 FEET…
- 8 Dec 2011
Light, inoperative
FLT 399 LGA-MCO, CREW REPORTED EMERGENCY EXIT LIGHTS OVER L1 AND R1 PASSENGER DOORS INOP. THE TECHNICIAN REMOVED AND REPLACED EMERGENCY EXIT LIGHT ASSY (41WL)…
- 16 Jun 2010
Unknown, odor
FLT 1757 FLL-SJU A/C DIVERTED TO NASSAU - STRONG BURNING SMELL REPORTED BY MULTIPLE FLT CREW MEMBERS AND FAA JUMPSEATER ROWS 5-13. PERFORMED TSM…
- 13 Jun 2010
Proximity Sensor, failed
FLT 1432 LGB-SFO RT REAR CABIN DOOR OPEN INDICATION IN FLIGHT. FLIGHT RETURNED TO FIELD (LGB). PER TSM 52-13-00-810-804 REMOVED AND REPLACED PROX SENSOR 17WV2…
- 31 Jul 2007
Power Cable, faulty
FLT 728, APPROX 8 AM, BQN TO JFK - ELECTRICAL/SMOKE ODOR AT ROW 24/25. SMELL CEASED WHEN TV'S WERE SHUT OFF. PERFORMED TSM 23-39-00-810-801 PROCEDURE. FOUND…
- 29 Apr 2005
Actuator, malfunctioned
AIRCRAFT EXPERIENCED WING FLUTTER ON CLIMB-OUT PASSING 6000 FT STEADY 250KIAS WHILE TURNING. NO ABNORMAL YAW, NO ABNORMAL INDICATION ON FLIGHT CONTROL ECAM…
- 16 Apr 2005
Actuator, leaking
L2 DOOR ASSIST DAMPER CYLINDER LEAKING. REPLACED L2 DOOR ASSIST ACTUATOR PER AMM 52-13-14-04. NO LEAKS NOTED.