N589JB
2004 Airbus A320-232 standard FAA →
registration
- 2004
NTSB
- 18 Feb 2024
incident, Merida MX
service difficulty reports
53 reports
- 21 Nov 2024
Unknown, odor
FLT#779, JFK-MBJ. CREW INFLIGHT AND FLIGHT NOTICED PUNGENT DIRTY SOCKS FUMES IN THE DESCENT CAUSING ORAL AND THROAT IRRITATION PERSISTENT; C/W NOTICE 2017…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: FUSELAGE / REAR FUSELAGE / FR 68 LH / DOOR STOP FITTING #1 / CRACK DAMAGE - TIME-LIMITED REPAIR, A CRACK WAS FOUND ON DOOR STOP…
- 1 Sep 2024
Skin, corroded
DURING HEAVY MAINTENANCE: WINGS / RH WING / TOP SKIN PANEL 2 / UPPER SURFACE / FRONT SPAR & RIBS 19-20 / BONDING SPIGOT /CORROSION DAMAGE – PERMANENT REPAIR;…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: FUSELAGE / REAR FUSELAGE / FR 68 RH / DOOR STOP FITTING #1 / HOLE LWR INB / CRACK - PERMANENT REPAIR; REFERENCES: /1/ AEM EA…
- 1 Sep 2024
Skin, corroded
DURING HEAVY MAINTENANCE: CORROSION TOP SKIN UPPER SURFACE OVERHAND LOC RIB 17 RH WING; REF AEROMAN NR 2024-448504 WO 2024 262/1 ACCOMPLISH THE REPAIR OF THE…
- 1 Sep 2024
Skin, corroded
DURING HEAVY MAINTENANCE: CORROSION TOP SKIN UPPER SURFACE RIB 20 LEADING EDGE RH WING; REF AEROMAN NR 2024-448430 WO 2024 262/1 ACCOMPLISHED THE REPAIR OF…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR68 LH DOOR STOP FITTING Ñ1 AREA AT LOWER O B HOLE. CRACK DIRECTION 6 AND 12 OCLOCK VIEW LOOKING AFT.…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR68 LH DOOR STOP FITTING Ñ1 AREA AT LOWER I NB HOLE. CRACK DIRECTION 6 AND 1 OCLOCK VIEW LOOKING AFT.…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR68 LH DOOR STOP FITTING Ñ1 AREA AT UPPER I NB HOLE. CRACK DIRECTION 6 AND 11 OCLOCK VIEW LOOKING AFT.…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR68 RH DOOR STOP FITTING Ñ1 AREA AT LOWER I NB HOLE. CRACK DIRECTION 6 OCLOCK VIEW LOOKING AFT. CRACK D=…
- 1 Sep 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON OPEN FASTENER HOLE B FRAME 16 R/H SIDE AND CONFIRM INDICATION USING BOROSCOPE VIEW AS PER REF NTM…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR66 LH DOOR STOP FITTING Ñ1 AREA AT LOWER I NB HOLE. CRACK DIRECTION 5 OCLOCK VIEW LOOKING FWD. CRACK D=…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR66 LH DOOR STOP FITTING Ñ1 AREA AT LOWER I NB HOLE. CRACK DIRECTION 5 OCLOCK VIEW LOOKING FWD. CRACK D=…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK FOUND IN OPEN HOLE H3 (LOWER INBOARD LOCATION) ON DOOR STOP 7 FR16 RH SIDE, CRACK DIRECTION 6 OCLOCK, D1-D2+0.065 INCH;…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH SIDE IN OPEN FASTENER HOLE H3 AT DOOR STOP FITTING 7 POSITION. CRACK DIRECTION IS 5 OCLOCK, CRACK…
- 1 Sep 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND IN OPEN HOLE H1(UPPER INBOARD POSITION) ON DOOR STOP FITTING 7 FR 16 LH SIDE. CRACK DIRECTION 5 OCLOCK…
- 6 Feb 2024
Cabin Pressure, faulted
FLT#426, TPA-JFK. (AIRCRAFT PERFORMED AN AIR TURN BACK TO TPA). 'ON CLIMB OUT V/S INDICATED EXCESSIVE CABIN CLIMB. CABIN ALTITUDE STARTED TO CLIMB ABOVE…
- 18 Dec 2023
Unknown, unknown
FLT#1975, JFK-YVR. 'DURING FLIGHT CABIN CREW REPORT A BURNING ODOR FROM SEAT ROW 7 TO 13 MID CABIN. THE LTV SYSTEM WAS DEACTIVATED PER QPH PROCEDURE. AFTER…
- 5 May 2023
Light, failed
FLT#2534, PBI-DCA. 'DURING EMERGENCY LIGHT CK OF WEEKLY, FOUND FWD GALLEYS LIGHT - INOP; REMOVED AND REPLACED FWD EPSU BATTERY PACK IAW AMM 33-51-38. OPS…
- 17 Sep 2022
None, failed
FLT#41, FLL-MDE. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) ' IN-FLIGHT FMGC 1 FAILED AND BLANKED CAUSING AP1 TO TRIP. CAME BACK AND THEN FAILED WITH 2FD2…
- 9 Sep 2022
None, none
FLT#2119, ORH-FLL. 'DIRTYSOCK SMELL REAR CABIN LANDING & FRONT; "COMPLIED WITH INFORMATION NOTICE 2017-T015, SECTION A, ISOLATED FAULT TO TYPE 10, (A), 1, C…
- 5 Jun 2022
Actuator, failed
FLT#1327, FLL-MBJ. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) ' ENG 2 COMPRESSOR VANE IN FLIGHT AND AFTER LANDING. DID NOT LAND OVERWEIGHT (145,200 #);…
- 11 May 2022
None, none
FLT#819, JFK-ATL. 'BELOW 10,000 CABIN ODOR / FUME DIRTY SOCK SMELL ( APU SYSTEM ); PERFORMED APU CLEANING PROCEDURE AND INSP APU AREA FOR LEAKS. GAINED ACCESS…
- 14 Mar 2022
Door, false indication
FLT#2312, CUN-SMF. 'DOOR 2L ON ECAM SHOWING DOOR SLIDE ARMED ERRONEOULY (SLIDE INDICATIONS ON ECAM - PAX DOOR ARMED IND); PERFORMED OPS TEST OF LS DOOR AMM…
- 17 Apr 2021
Ecs, contaminated
FLT 512, AUS-FLL. STRONG DIRTY SOCK ODOR FROM PACKS WHEN ON APU BLEED OR ENGINE BLEED. *REPEAT WRITE UP. (4-10-21); INSP APU COMP & FOUND MINOR OIL SATURATION…
- 16 Dec 2020
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION LOWER SILL FR 66RT AFT GALLEY AREA (CPCP RELATED 534147-01). REMOVED AND REPLACED LOWER SILL LOCATED ON RT SIDE AT LEVEL…
- 16 Dec 2020
Door Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION ON EMERGENCY EXIT DOOR 834 INNER FRAME SEGMENT 1 IN PASSENGER CABIN, REF AEROMAN NR 2020-359260 W/O 2020 160/1.…
- 16 Dec 2020
Door Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION ON EMERGENCY EXIT DOOR 844, INNER FRAME SEGMENT 1, IN PASSENGER CABIN, REF AEROMAN NR 2020-359260 W/O 2020 160/1.…
- 16 Dec 2020
Door Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION ON EMERGENCY EXIT DOOR 843 INNER FRAME SEGMENT 1, IN PASSENGER CABIN, REF AEROMAN NR 2020-359258 W/O 2020 160/1.…
- 16 Dec 2020
Door Frame, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION ON EMERGENCY EXIT DOOR 833, INNER FRAME SEGMENT 1, IN PASSENGER CABIN, REF AEROMAN NR 2020-359259 W/O 2020 160/1.…
- 16 Dec 2020
Power Supply, no test
DURING HEAVY MAINTENANCE, REF N/R 2020-359482 W/O 2020 160/1, INOPERABLE EPSU-EMERGENCY POWER SUPPLY UNIT 11WL IN PASSENGER CABIN. R & R EMERGENCY POWER…
- 16 Dec 2020
Slide, faulted
DURING HEAVY MAINTENANCE, EPSU EXTERNAL LOAD FAULT INDICATION ON EPSU 10WL IN FWD CABIN, REF AEROMON NR 2020-359485 W/O 2020 160/1. PERFORMED TSM FAULT…
- 16 Dec 2020
Epsu, failed
DURING HEAVY MAINTENANCE, INOPERABLE EPSU, EMERGENCY POWER SUPPLY UNIT 12WL IN PASSENGER CABIN. R & R EMERGENCY POWER SUPPLY UNIT EPSU FIN (12WL), IAW AMM…
- 25 Jun 2020
Sensor, failed
FLT 647, RETURNED TO FIELD. ON CLIMB OUT, AP 1 ENGAGED FL 280, ACFT PITCHED DOWN, SAT & TAT SHOWED EXTREME NEG NUMBERS. DISENGAGED AP, LEVELED AT FL 320. SAT…
- 22 Jun 2020
Fcu, failed
FLT 533, BDL-TPA. EXPERIENCED TWO UNCOMMANDED PITCH DOWNS DURING CLIMB ON AP1. DISCONNECTED AP BOTH TIMES TO RECOVER. TAT, SAT & ISA ALL SHOWED -80C DURING…
- 2 Jun 2019
Battery, failed
FT 225, DURING EMERGENCY CABIN BITE TEST, BATT FAULT. FOUND BATTERY FAULT AT 10WL & 13WL. REMOVED AND REPLACED ESPU BATTERY AT 10WL & 13WL IAW AMM 33-51-38.…
- 2 Jun 2019
Battery, failed
FT 225, DURING EMERGENCY CABIN BITE TEST, BATTERY FAULT. FOUND THE BATTERY FAULT AT 10WL & 13WL. REMOVED AND REPLACED ESPU BATTERY AT 10WL & 13WL IAW AMM…
- 13 Apr 2019
Light, detached
FT # 668, PSE-MCO. EMERGENCY EXIT LIGHT NEAR FLOOR AND BETWEEN L1 DOOR AND FWD FA JUMPSEAT HAS DETACHED FROM WALL; ATTACHED LIGHT MOUNT PLATE TO PANEL AMM…
- 18 Aug 2017
Unknown, odor
AT FL 350, DURING CRUISE, APPROXIMATELY 42 MIN INTO FLIGHT, A DISTINCT ODOR PERSISTED WHILE IN CRUISE, SMELLED LIKE DIRTY LAUNDRY. STRONG IN COCKPIT. CABIN…
- 4 Oct 2016
Battery Pack, inoperative
AFT EMERGENCY LIGHTING FAULTED DURING CIDS EMERGENCY TEST. R & R THE BATTERY PACK 13WL IAW AMM 33-51-38, TEST PASS, OPS CHECKED GOOD.
- 7 Jan 2015
Fairing, unsecure
AIR RETURN TO DEPARTURE DUE TO A VIBRATION DURING CLIMB. FOUND SPEED TAPE PARTIALLY OFF FROM WTB PANEL 191BT. APPLIED NEW SPEED TAPE IAW SRM 53-35-00.
- 14 Jul 2013
Transducer, failed
CREW DECLARED AN EMERGENCY AFTER LANDING GEAR EXTENSION DUE TO ECAM BRAKES /A-SKID/NWS FAULT. ACCOMPLISHED TROUBLESHOOTING IAW TSM 32-42-00, AND FOUND BRAKE…
- 24 Feb 2013
Battery, failed
FLT 866 PUJ-JFK, DURING MAINTENANCE LEFT AFT EPSU FAILED BATTERY CAPACITY TEST. REMOVED AND REPLACED BATTERY FOR THE LEFT EPSU AFT POSITION. OPS CHECK NORMAL…
- 14 Jul 2012
Battery, failed
FLT 654 SJU-TPA, DURING MAINTENANCE THE RIGHT EMERGENCY LIGHT FAILED TEST. REMOVED AND REPLACED BATTERY FOR RIGHT EPSU IAM AMM 33-51-38. OPS CHECK GOOD.
- 28 Apr 2012
Release Cable, faulty
FLT 6407 JFK-LCQ, ON HEAVY MAINTENANCE CHECK FOUND RT SIDE OPERATIONAL TEST OF EMERGENCY EXIT HATCHES FAILED TRAVEL REQUIREMENTS. RIGHT SIDE SLIDE RELEASE…
- 13 Jun 2011
Control Unit, binding
FLT 139 BUF-JFK, THE FLIGHT CREW EXECUTED A GO AROUND AT 2000 FEET DUE TO FLAP HANDLE BINDING FROM POSITION 1 TO POSITION 2. THE F/O WAS ABLE TO RECOVER…
- 3 Feb 2011
Cooling Fan, failed
FLT 1783 MCO-BOG, A/C DIVERTED TO KIN - THE CREW DECLARED EMERGENCY DUE TO AFT AVIONICS BAY ALARM CAME ON. THERE WAS NO SIGN OF SMOKE EITHER IN CABIN OR IN…
- 5 Jun 2010
Epsu, failed
FLT 526 MCO-EWR ON GROUND MAINTENANCE CHECK - RT EPSU (EMERGENCY POWER SUPPLY UNIT) FAILED OPERATION CHECK ON EMERGENCY LIGHTS SYSTEM. REMOVED AND REPLACED RT…
- 28 Mar 2010
Module, intermittent
FLT JB477 BOS-OAK AIRCRAFT HAD 3 UNCOMMANDED PITCH DOWNS WITH LOSS OF 100 FT NO ASSOCIATED ECAMS/FLIGHT CONTROL FAULTS. AIRCRAFT WAS AT CRUISE AT…
- 22 Mar 2007
A/C Pack, odor
APRX 1645Z, NO VISIBLE SMOKE (BURNING RUBBER SMELL) DURING APPROACH QRH COMPLIED WITH MID CABIN. EMERGENCY DECLARED. SMELL SUBSIDED UPON EXITING TAXIWAY.…
- 20 Mar 2006
Smoke, detected
JUST PRIOR TO LANDING FLT ATTENDANTS SMELLED SMOKE MID CABIN. TV'S WERE TURNED OFF WITH MASTER SWITCH, SMELL WENT AWAY. ACCOMPLISHED ELECTRICAL ODOR SYSTEM…
- 18 Mar 2006
Electrical Box, unknown
ROW 14ABC TV'S INOP. PAX SMELLED BURNING COMING FROM UNDER THE SEAT AND THEN THE ROW OF TV'S QUIT WORKING. MASTER SWITCH TURNED OFF AS A PRECAUTION, SMELL…
- 7 Aug 2005
Computer, malfunctioned
ECAM MSG FLAPS LOCKED FLT CNTRL - ALIGNMENT FAULT. DURING FINAL APP TO BUR, FLAP HANDLE MOVED TO FLAP 2 POSITION. FLAPS LOCKED BETWEEN POS 1 AND POS 2. SLATS…