- 16 Mar 2005
Skin, cracked
CLT - RON - SKIN, 1.75 INCHES, CRACKED, STA 727E, STR 18L. INSTALLED DOUBLER IAW SRM. (K)
- 4 Oct 2004
Skin, cracked
SKIN, 1 INCH CRACK, STRINGER 24R, BETWEEN STA 727D AND 727E. INSTALLED DOUBLER IAW SRM 53-00-01, FIG 229.
- 4 Oct 2004
Skin, cracked
SKIN, 3.125 INCH CRACK, AT STRINGER 25R, STATION 727E. INSTALLED DOUBLER IAW SRM 53-00-01, FIG 229.
- 25 Jun 2004
Rod, damaged
PHL - FLT 301 - ON CLIMB-OUT FROM PHL, EN ROUTE TO MCO, THE AIRCRAFT WOULD NOT PRESSURIZE. CREW SWITCHED ON THE ENGINE BLEEDS WITH NO HELP. QUICK REFERENCE…
- 20 Jan 2004
Stiffener, corroded
PIT - FOUND STIFFENER CORRODED 1 INCH BY 1 INCH, BS 1016 APBH BL-0. CUT OUT DAMAGE AND INSTALLED REPAIR DOUBLER PER BOEING DWG 65C28106 REF EO 5302V112A. (M)
- 22 Aug 2003
Skin, cracked
FOUND SKIN CRACKED 2.25 INCH, S23R 4 INCHES AFT 727D. INSTALLED DOUBLER PER EA 94640, SRM 737-300 AND 53-00-01. (M)
- 18 Sep 2002
Csd, failed
TPA - FLT 1883 - FLIGHT DEPARTED CLT, EN ROUTE TO SRQ, WITH MEL 49-1 APPLIED TO APU FOR NOT STARTING. DURING DESCENT INTO SRQ, AT 8,000 FEET, THE NR 2 ENGINE…
- 13 Mar 2002
Charger, failed
SYR - MAINTENANCE REPORTED THE CABIN CENTER OVERHEAD EMERGENCY LIGHT AND THE LEFT OVERWING EMERGENCY EVACUATION LIGHT INOPERATIVE. MAINTNANCE REMOVED AND…
- 27 Mar 2001
Floor Support, corroded
PIT - FOUND BEAM SUPPORT CORRODED .5 INCH TO 6 INCHES AT NUTPLATES, BS 727D-827 ON ALL LEFT SIDE FLOOR SUPPORT. CORROSION LEVEL 1, TASK NR C53-208-01.…
- 22 Mar 2001
Floor Support, corroded
PIT - FOUND FLOOR SUPPORT BEAM CORRODED 160 INCHES, STATION 500D TO STATION 380 FLOOR SUPPORT BEAM 26L. CORROSION LEVEL 1, TASK C53-208-01. REMOVED CORROSION,…
- 20 Mar 2001
Bracket, cracked
PIT - FOUND BRACKET CRACKED .375 INCH, 14 INCHES INBOARD OF ENGINE PYLON LEFT WING REAR SPAR. REPAIRED PER 2024-T3 DWG NR 69-43586-7 SH 26 ZONE B6 PER SRM…
- 20 Mar 2001
Link, corroded
PIT - FOUND LINK WITH 3 INCH DIAMETER FRETTING, RIGHT WING INBOARD DOG BONE LINK LUG ON AFT SIDE OF SPAR. BLENDED AREA, DAMAGE TREATED AND PRIMED. (M)
- 8 Mar 2001
Spar, damaged
PIT - FOUND REAR SPAR WITH PLY SEPARATION .5 INCH BY .5 INCH, BOTTOM INBOARD SPAR END. REMOVED SPLINTER PLY THEN COMPLETED 2 WET LAY UP THEN RESEALED EDGES…
- 26 Feb 2001
Floorbeam, corroded
PIT - FOUND FLOORBEAM CORRODED, .5 INCH BY 1 INCH IS LARGEST, 1 INCH, .75 INCH, AND .25 INCH STATION 996.5 LBL 50 RBL 50. PER TYPICAL REPAIR 53-15-01B. (M)
- 13 Jun 2000
Outflow Valve, failed
CLT - FLT 665 - EN ROUTE FROM CLT-PBI, AT FL350, THE CABIN ALTITUDE WARNING HORN SOUNDED. CABIN ALTITUDE WAS AT 10,000 FEET AND CLIMBING. CAPTAIN DECLARED AN…
- 8 Apr 2000
Skin, cracked
PIT - FOUND SKIN CRACKED .25 INCH, STATION 380 AT A/C BELLY CENTER LINE. INSTALLED EXTERIOR DOUBLER PER SRM 53-30-04. (M)
- 29 Jan 1999
Strap, out of position
CLT - FLT 83 - IMMEDIATELY AFTER DEPARTING CLT, A LOUD RAPPING NOISE AT THE AFT LEFT ENTRY DOOR WAS HEARD BY PASSENGERS AND THE FLIGHT ATTENDANTS IN THE REAR…
- 25 Jul 1997
Position Sensor, loose
PIT - FLT 183 - UNSAFE NOSE GEAR INDICATION AFTER TAKEOFF. DURING TROUBLESHOOTING PROCEDURES, FOUND CIRCUIT BREAKER WAS TRIPPED. RESET. ALL INDICATIONS WERE…
- 27 Jun 1997
Battery Pack, discharged
ORD - MAINTENANCE FOUND THE FORWARD LEFT SECTION OF CABIN EMERGENCY EXIT LIGHTING INOP. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK. OPS CHECK NORMAL. (M)
- 15 Apr 1997
Floor Beam, corrosion
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH CORROSION STA 312 RBL 10 FLOOR BEAM. INSTALLED T-CAP STA RBL 20 TO LBL 19. REPAIRED PER…
- 15 Apr 1997
Skin, cracked
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 1 INCH CRACK INBOARD LEADING EDGE OF LEFT OUTBOARD MID-FLAP SKIN. INSTALLED DOUBLER, REPAIRED PER EA 42280.…
- 15 Apr 1997
Bulkhead Skin, cracked
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 3 CRACKS IN BULKHEAD 1 INCH, 1 INCH AND 2.0 INCH 178 BULKHEAD SKIN RLB 5, LBL 7, 6 INCH - 9 INCH BELOW FLOOR…
- 15 Apr 1997
Beam, corrosion
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 2 INCH CORROSION BS 312 RBL 12 BEAM. FABRICATED UPPER T-CHORD, REPAIRED PER TYPICAL REPAIR 53-10-03.…
- 10 May 1995
Eel, inoperative
LGA - FORWARD ENTRY EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY IN FORWARD ENTRY AREA. OPS CHECK OK. (M)