N587CA
1957 Convair 640-440D standard FAA →
reservations
earlier registrations
1 past record
- 1957
service difficulty reports
23 reports
- 23 Feb 2011
Pitot Tube, failed
NR 2 PITOT SWITCH TRIPPED IN-FLIGHT, PULLED CIRCUIT BREAKER AS PRECAUTION, SMELLED "ELECTRICAL" ODOR PRIOR TO PITOT TRIPPING. NR 2 PITOT SYS CHECK. ALL…
- 5 Aug 2010
Processor, failed
TCAS INOP. FLAGGED ON ALL INDICATORS. SMELLED SMOKE. TCAS C/B PULLED. R & R TCAS PROCESSOR, PN 066-500002120, SN OFF 1547, SN ON 1687. TEST IAW CV640, MM CH…
- 3 Aug 2010
Relay, failed
NR1 ENGINE FIRE LIGHT CAME ON INTERMITTENTLY DURING TURBULENCE AND ROUGH PAVEMENT. R & R FIRE DETECTOR BOX PN 33958-3, SN OFF 3654, ON 829 TEST OK. TEST IAW…
- 27 Jan 2010
Pcu, failed
ON 6/18/09, WHILE TAXIING FOR TAKEOFF, OBSERVED SMOKE COMING FROM THE RT ENGINE, THE ENGINE WAS SHUTDOWN AND SECURED. THE PROPELLER MOVED OUT OF "FINE" PITCH…
- 18 Jun 2009
Engine, overtemp
WHILE TAXIING FOR TAKEOFF, OBSERVED SMOKE COMING FROM THE RT ENGINE, ENGINE WAS SHUTDOWN AND SECURED. THE PROPELLER MOVED OUT OF "FINE" PITCH POSITION CAUSING…
- 7 Mar 2009
Filter, dirty
RT FUEL FILTER BLOCKED LIGHT CAME ON DURING TAKEOFF. TAKEOFF WAS WITH WATER METH (ON) AND WAS ABORTED, THE WARNING LIGHT WENT OUT ON POWER REDUCTION. MX…
- 14 Nov 2008
Spring Assy, stretched
AILERON CONTROL CABLES BINDING TO THE RIGHT FROM FULL LEFT POSITION. INSPECTION OF AILERON CONTROL CABLES REVEALED STRETCHED SPRING AT RUDDER INTERCONNECT.…
- 5 Feb 2007
Flap System, malfunctioned
FLIGHT 5659 - DURING MDW APPROACH RECEIVED A FLAP FAIL CAUTION MESSAGE, CREW DECLARED AN EMERGENCY AND FLIGHT LANDED WITHOUT INCIDENT. COMPLIED WITH AD…
- 18 Oct 2006
Axle, cracked
WHEN REMOVING NOSE AXLE TO C/W AD83-01-02 FOR THE 12,000 HOUR MAGNETIC PARTICLE TESTING. A CRACK AROUND THE AXLE FLANGE THAT THE BEARING SPACER RIDES AGAINST…
- 23 Jun 2005
Skin Panel, corroded
SURFACE CORROSION WAS FOUND ON THE RT IB SKIN PANEL AT APPROX STA 96.91. THIS CORRODION WAS NOTED UNDER THE INSULATION PANEL LOWER SIDE. REPLACEMENT OF SKIN…
- 7 Jun 2005
Longeron, corroded
INTERGRANULAR CORROSION WAS FOUND ON THE LONGERON CHANNEL AT FUSELAGE BUTTOCK LINE 0, WING STATION 403.0. THIS CORROSION NOTED ON THE LT SIDE, 10 INCHES…
- 6 Aug 2004
Bellmouth, corroded
DURING WATER METHANOL SYSTEM TROUBLESHOOTING, MAINTENANCE PERSONNEL FOUND SEVERE CORROSION AND SEVERAL OF THE WATER METHANOL SYSTEM COMPONENTS LOCATED INSIDE…
- 6 Aug 2004
Door, corroded
BAK - DUIRNG WATER METHANOL SYSTEM TROUBLESHOOTING, MAINTENANCE PERSONNEL FOUND SEVERE CORROSION ON SEVERAL OF THE WATER METHANOL SYSTEM COMPONENTS LOCATED…
- 6 Aug 2004
Transmitter, corroded
DUIRNG WATER METHANOL SYSTEM TROUBLESHOOTING, MAINTENANCE PERSONNEL FOUND SEVERE CORROSION ON SEVERAL OF THE WATER METHANOL SYSTEM COMPONENTS LOCATED INSIDE…
- 6 Aug 2004
Tube, corroded
BAK - DURING WATER METHANOL SYSTEM TROUBLESHOOTING, MAINTENANCE PERSONNEL FOUND SEVERE CORROSOIN ON SEVERAL OF THE WATER METHANOL SYSTEM COMPONENTS LOCATED…
- 6 Aug 2004
Check Valve, corroded
BAK - DURING WATER METHANOL SYSTEM TROUBLESHOOTING, MAINTENANCE PERSONNEL FOUND SEVERE CORROSION ON SEVERAL OF THE WATER METHANOL SYSTEM COMPONENTS LOCATED…
- 20 May 2004
Floorbeam, corroded
DURING A SCID INSPECTION 53-20, A MISSING RIVET HEAD WAS FOUND AT STA 712.0. RT SIDE AT THE FLOORBEAM TO BELTFRAME ATTACH POINT. CORROSION WAS FOUND UNDER…
- 20 May 2004
Floorbeam, corroded
DURING A SCID INSPECTION 53-20, CORROSION WAS FOUND ON FLOORBEAM AT STA 681.0 RT SIDE AT BELTFRAME. AN AREA OF APPROX 3 INCHES X 5 INCHES ON THIS FLOORBEAM…
- 20 May 2004
Beltframe, corroded
DURING A SCID INSPECTION, CORROSION WAS FOUND ON RT BELTFRAME STATION 665.0 AT FLOOR LINE. APPROX. 8.5 INCHES OF THE BELTFRAME IS CORRODED AT THE FLOORBEAM…
- 27 Feb 2003
Line, leaking
AFTER MOVING THE LANDING GEAR HANDLE (DOWN) AND SELECTING FLAPS (DOWN); THE HYDRAULIC PRESSURE GAUGE READ ZERO PSI. NO FLUID WAS VISIBLE IN THE HYDRAULIC…
- 24 Apr 2002
Battery, overheated
AFTER ARRIVAL, AIRCRAFT POWERED BY BATTERY FOR 30 MIN. - FANS, LIGHTS, CARGO DOOR, ECT. WHEN POWERED UP, NOTED 18 V, TURNED ON BATT INTERLOCK OVERRIDE FOR A…
- 10 Dec 1996
Frame, corroded
DURING C-CHECK INSPECTION, FOUND CORROSION ON THE INBOARD LEFT NACELLE FRAME AT STATION 150. THE ABOVE DAMAGE WAS REPAIRED IAW KHA. EA NR CV-54-31. BY…
- 12 Jul 1996
Inverter, failed
YIP/OKC - FLT 587 - TWENTY NM FROM COLUMBIA, MISSOURI, THE ACFT FDR AND GPWS WARNING LIGHTS ILLUMINATED. ABOUT TEN SECONDS LATER, THE FLIGHT CREW NOTED SMOKE…