service difficulty reports
122 reports
- 19 Nov 2013
Handle, obstructed
R1 DOOR ARMING HANDLE DIFFICULT TO ARM & DISARM. REPOSITIONED STATIC LINE IAW AMM. DOOR HANDLE ARMS NORMAL.
- 14 Nov 2013
Connector, damaged
PC AIR CONNECTOR IS DAMAGED & PC AIR WILL NOT REMAIN ATTACHED TO AIRCRAFT.
- 7 Oct 2013
Girt Bar, out of adjust
DOOR 1L ARMING LEVER VERY DIFFICULT TO OPERATE FOR ARMING & DIS-ARMING. ADJUSTED GIRT BAR, OPERATION CHECKED OKAY.
- 23 Aug 2013
Light, loose
EMERGENCY FLOOR LIGHTING SEAT 11ABC IS FLASHING ON & OFF INFLIGHT. DEBRIEF FLIGHT ATTENDANTS STATED EMERGENCY EXIT LIGHT PATH LIGHTING AT SEAT 11C WAS LOOSE.…
- 21 Aug 2013
Cover, loose
11C EMERGENCY LIGHT STRIP IS LOOSE. SECURED EMERGENCY EXIT LIGHT COVER.
- 9 Jul 2013
Valve, leaking
DURING PRE-FLT, FLUID DRIPPING FROM PORT UNDER AFT CARGO BAY. DRAIN PORTABLE WATER TANK AND WATER STOPPED. PORTABLE WATER SYS INOPERATIVE FOR ENTIRE ACFT.…
- 7 Jul 2013
Girt Bar, obstructed
FOUND LANYARD UNDER GIRT BAR. SECURED LANYARD AND DOOR OPS NORMAL.
- 30 Jun 2013
Actuator, leaking
HYDRAULIC FLUID LEAKING FROM LT ENGINE. OTBD UPPER REVERSER ACTUATOR LEAKING BEYOND LIMITS.
- 28 Jun 2013
Girt Bar, obstructed
R1 DOOR WILL NOT ARM. FOUND R-1 DOOR STATIC LINE EXCESS LENGTH INTERFERS WITH GIRT BAR LATCH STOWED LINE. DOOR ARMS NORMAL, ALL OPS NORMAL.
- 22 Jun 2013
Light, loose
EMERGENCY LIGHT BETWEEN 12C & 11C IS LOOSE. SECURED, LIGHT CHECKED GOOD.
- 25 May 2013
Bottle, discharged
R2 DOOR SLIDE PRESSURE IN RED. REMOVED AND REPLACED R2 DOOR ASSIST BOTTLE AS PER AMM.
- 19 May 2013
Skin, gouged
FUSELAGE SKIN GOUGED BS 1320 + 1 INCH AND 4 INCHES BELOW S28R. REMOVED DAMAGE, NDT FOR METAL LOSS. FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGE FABRICATED AND…
- 18 May 2013
Floorbeam, damaged
FLOORBEAM, BS 1600, RBL 8-11 DAMAGED. INSTALLED REPAIR STRAPS AND ANGLES. MAJOR REPAIR.
- 18 May 2013
Skin, dented
DENT FOUND AT BS 650, STRINGER 15, LT FORWARD OF DOOR 2L ON EXISTING DOUBLER. FOUND DENT WITHIN LIMITS OF SRM 53-00-01, PAGE 104.
- 16 May 2013
Skin, dented
FOUND NUMEROUS DENTS ON THE UPPER SURFACE OF THE RT HORIZONTAL STABILIZER. FOUND DENTS TO BE WITHIN LIMITS IAW SRM 55-10-01. ACCOMPLISHED HFEC IAW NTM…
- 14 May 2013
Structure, misrepaired
LEFT WING NR 3 SLAT UPPER SURFACE T/E WEDGE ATTACH FASTENERS 33" AND 45" FROM INBD EDGE SHOW FOUR LOCK FASTENERS IAW LOCATION REF SM-50-57-56-01-JD, PG 44.…
- 14 May 2013
Skin, misrepaired
LEFT WING NR 5 SLAT UPPER T/E ATTACH FASTENERS AT EACH RIB ATTACH POINT ARE SCREWS WITH A "VF" HEAD MARKING WHILE SM-50-57-56-01-JD, PG 56 CALLS OUT FOR LOCK…
- 14 May 2013
Skin, damaged
DAMAGE NOTED TO FUSELAGE SKIN AT BS 1445-1455 BETWEEN S23-24R. REPAIRED DAMAGE IAW EA130487 AND ECRA5360-01285 HFEC WAS CW IAW NDT PT6 51-00-1 9. NO CRACKS…
- 13 May 2013
Fastener, wrong part
INCORRECT FASTNER INSTALLED 4.5 INCHES AFT OF BS 660 AND 2 INCHES BELOW STR 27R. REMOVED DAMAGE, PERFORMED NDT WITH NO FINDINGS. FABRICATED REPAIR PARTS &…
- 13 May 2013
Pca, no test
MIDDLE RUDDER PCU AND LT HYD SYS FAILED FREE PLAY CHECKS IAW TC 5R27I7014. R & R MIDDLE RUDDER PCA. R & R RUDDER RATIO CHANGER ACTUATOR AMM 27-21-13. ADJUSTED…
- 13 May 2013
Actuator, leaking
LEFT ELEVATOR CENTER ACTUATOR LEAKING ABOVE LIMITS SPECIFIED IN AMM 29-00-99. R & R LT ELEVATOR CENTER ACTUATOR. CHECKED FOR WEAR-ALL DIMENSIONS WITHIN…
- 10 May 2013
Skin, gouged
AFT CARGO DOOR SKIN GOUGED AND BENT AT AFT LOWER CORNER. REMOVED DAMAGE AT AFT LOWER CORNER IAW SRM 51-10-02 AND SRM 52-30-01, REPAIR 4. FABRICATED &…
- 8 May 2013
Skin, gouged
AFT CARGO DOOR SKIN GOUGED AND BENT AT FWD LWR CORNER. REPAIRED AFT CARGO DOOR SKIN IAW SRM 52-30-01 REPAIR 4 FIGURE 201. HFEC INSPECTION ACCOMPLISHED PER NDT…
- 13 Mar 2013
Spring, weak
R1 DOOR HINGE LOWER NOT FLUSH 2R UPPER HINGE NOT FLUSH. R2 DOOR HINGE CHECKED GOOD ON R1 DOOR LOWER HINGE COVER THE SPRING IS WEAK. REMOVED COVER IAW CDL 52A.…
- 4 Mar 2013
Fan, noisy
RIGHT RECIRC IS TOO LOUD WHILE AIRBORNE. REPLACED RIGHT RECIRC FAN.
- 4 Feb 2013
Harness, damaged
L1 DOOR SLIDE HARNESS LOWER LATCH ATTACHMENT RIPPED. REMOVED & REPLACED DOOR SLIDE HARNESS. INSPECTED L1 DOOR SLIDE. OPS CHECKED GOOD.
- 2 Feb 2013
Light, inoperative
DOOR 4R EMERGENCY EXIT LIGHT INOP ON OUTSIDE. RELAMPED EXTERIOR EMERGENCY LIGHT AT DOOR 4R, OPS NORMAL.
- 22 Jan 2013
Socket, dirty
R1 DOOR EXTERIOR EMERGENCY SLIDE LIGHT INOPERATIVE. CLEANED LIGHT SOCKET AND REPLACED LAMP. OPS CHECKED NORMAL.
- 22 Jan 2013
Socket, dirty
L2 DOOR EXTERIOR EMERGENCY SLIDE LIGHT INOPERATIVE. CLEANED LIGHT SOCKET AND REPLACED LAMP LIGHT, OPS CHECKED NORMAL.
- 27 Aug 2012
Connector, corroded
NR 1 VHF HAS INTERMITTENT SHORT BURSTS OF STATIC. SOME JUST SECONDS APART. REMOVED ANTENNA CONNECTOR WAS VERY CORRODED BUT ANTENNA CABLE AND CONNECTOR CLEANED…
- 23 Jun 2012
Inlet, gouged
NR 1 ENGINE NACELLE HAS A DENT IN THE INLET COWL LOCATED AT THE 12:00 POSITION, DENT IS IN THE LIP, SKIN PORTION OF THE INLET COWL. DENT DIMENSIONS REPORTED…
- 29 May 2012
Rudder Control, malfunctioned
EICAS MESSAGE 'RUDDER RATIO' DISPLAYED, RUDDER RATIO LIGHT ILLUMINATED ON GROUND. RUDDER RATIO LIGHT ON TAKEOFF ROLL AND IN FLIGHT CROSS WIND LIMITED TO 15…
- 8 Mar 2012
Switch, faulty
LEFT SIDE WINDOW HEAT INOPERATIVE. DF AS PER 3141J, SUSPECT SWITCH. REPLACED SWITCH, OPS NORMAL AND TEST OKAY.
- 16 Feb 2012
Control Valve, faulty
A/C NOISE VERY LOUD EVEN WITH RT RECIRC FAN OFF WITH ALL VENTS OPEN. CHK'D FLIGHT DECK NOISE LEVEL PER SVC TIP 21-22-00 & FOUND DB LEVEL TO MEASURE AT 79,…
- 23 Dec 2011
Compressor, stalled
RT ENG COMPRESSOR STALL, RTFL. RIGHT ENGINE HAD COMPRESSOR STALL DURING T-O CLIMB AND LANDING (REVERSE) SAMC TEXT: ESN 726514. CHECK PER FIM. SEAMM REPORTS…
- 22 Dec 2011
Compressor, stalled
AIR RETURN DUE TO RIGHT ENGINE COMPRESSOR STALL DURING TAKE OFF, CLIMB AND LANDING. CHECKED PER MM. REPLACED ENGINE.
- 12 Nov 2011
Power Cable, burned
PC POWER CABLE FROM SIDEWALL TO SEAT 1CD BURNT AT SEAT CONNECTION, BREAKERS POPPED AT P37 PNL. WALL TO SEAT CABLE AND JUNCTION BOX DAMAGED. NIS SEA. INOPED…
- 9 Oct 2011
Life Vest, missing
OBSERVER LIFE VEST IS MISSING. SEAT TO BE RENDERED INOP UNTIL LIFE VEST REPLACED. DEFERRED PER SAMC. REPLACED OBSERVER LIFE VEST.
- 29 Aug 2011
Seal, damaged
CREW REPORT: VERY LOAD SQUEAL FROM DOOR 1R ON CLIMB BETWEEN 15K & FL30K. NOISE ON LOWER RT SIDE. REPAIRING REN ON LOWER RT CORNER, NEED TO SMOOTH OUT REN AND…
- 3 Aug 2011
Pbe, out of tolerance
FLIGHT DECK PBE POUCH IS SOFT. REPLACED PBE.
- 21 Jul 2011
Pseu, unknown
LANDING GEAR STATUS MSG ON LANDING. NO FAULTS FOUND, REPLACED PSEU PER MM. BITE NORMAL.
- 17 Jul 2011
Aileron, out of adjust
LATERAL TRIM OUT OF LIMITS AT 350 F0 1.8R, 250 F0 1.0R 180 F5 0.5R, 160 F20 0, 140 F25 0.2R, 130 F30 0. ADJUSTED THE FLAP SHIMS AND SPOILER GAPS PER MM. CREW…
- 15 Jul 2011
Skin, dented
DENT AT BS 458 AT S-17L. MAJOR REPAIR. REPAIRED DENT IAW EA PD57-53-147 AND EVA 81000.
- 12 Jul 2011
Crease Beam, corroded
CORROSION ON CREASE BEAM WEB AT STA 1120 - 1140. MAJOR REPAIR ACCOMLISHED: REMOVED WEB AND FABRICATED A REPLACEMENT. TREATED, PRIMED AND TOPCOATED AND…
- 12 Jul 2011
Crease Beam, corroded
CORROSION CREASEBEAM INNER CHORD BETWEEN BS 1580-1600 AT LBL 60. MAJOR REPAIR ACCOMPLISHED: REPAIRED CREASE BEAM INNER CHORD BETWEEN PER EA PD 57-53-149.…
- 11 Jul 2011
Floorbeam, corroded
CORROSION ON FLOORBEAM AT BS 324 RBL 35-58 IN MAIN CABIN (N-R 2775N00263). MAJOR REPAIR ACCOMPLISHED: REPAIRED PER INSTRUCTIONS PROVIDED IN EA PD57-53-146 AND…
- 6 Jul 2011
Doubler, corroded
CORROSION ON DOUBLER ON AFT PRESSURE DECK BS 1681 RBL 5-40 MAIN CABIN (N-R 2775N00390). MAJOR REPAIR ACCOMPLISHED: REPLACED DOUBLER SAME SIZE AND SHAPE PER SRM.
- 6 Jul 2011
Stringer Splice, corroded
CORROSION ON PRODUCTION SPLICE AT BS 1460 S-28L. (N-R 2775N00421). MAJOR REPAIR ACCOMPLISHED: FABBED AND INSTALLED STR SPLICE AND ATTACH CLIP AT STA 1460,…
- 5 Jul 2011
Floorbeam, corroded
CORROSION ON FLOORBEAM AT BS 365.25 RBL 0 - RBL 58 MAIN CABIN (N-R 2775N00239). MAJOR REPAIR ACCOMPLISHED: FABBED T-CHORD, STRAPS, ANGLES, SHIMS AND…
- 3 Jul 2011
Floorbeam, damaged
FLOORBEAM AT BS 660 HAS TOOLING MARK AT RBL 37-41.5 (N-R 2775N00559). MAJOR REPAIR ACCOMPLISHED: FABBED AND INSTALLED SUPPORT BEAM, ANGLES AND STRAPS AT STA…
- 3 Jul 2011
Floorbeam, corroded
CORROSION ON FLOORBEAM AT BS 1640 FROM LBL 5 -RBL 58. (N-R 775N00395) MAJOR REPAIR ACCOMPLISHED: REMOVED OLD REPAIR, FABBED AND INSTALLED T-CHORD AT STA 1640,…
- 1 Jul 2011
Floorbeam, corroded
CORROSION ON LOWER PART FLOORBEAM AT BS 345 RBL 58 RBL 12 (N-R 2775N00237). MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED STA 345 FLOORBEAM RBL 8 - RBL 60…
- 27 Jun 2011
Skin, dented
SKIN DENT AT BS 430 AT S-17L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED AREA AND INSTALLED A .063 INCH DOUBLER IAW SRM. IDENTIFIED REPAIR IAW GNMM.
- 27 Jun 2011
Skin, corroded
CORROSION AT BS 1681-1691 AT RBL. FABRICATED DOUBLER IAW SRM AND PWIT1422. TREATED AND PRIMED DOUBLER PER SRM AND RESTORED FINISH IAW AMM.
- 26 Jun 2011
Skin, dented
FWD CARGO DOOR DENT AFT EDGE OF DOOR, APPROX 4\ FWD OF AFT EDGE, CTR OF DOOR. DENT IS 1.25 X 1.25 X .046 DEPTH. FOUND IT OUT OF LIMITS PER SRM. DENT LESS THAN…
- 9 May 2011
Indicator, faulty
EXCESSIVE RUDDER TRIM. ACCOMPLISHED UP TO BLOCK 7 RUDDER RIG HIGH AND LOW SPEED GOOD. NEED TO CONTINUE BLOCK 8 PG 116 CHECK THERMAL COMPENSATION. BOTTOM…
- 20 Apr 2011
Control Valve, defective
COCKPIT AIR NOISE EXCESSIVE. DUCT CLEAN UP IS DONE, PREP TO ACP ENG RUN TO CHECK DUCT PRESS AND DECIBLE READINGS. COMPLETED NOISE CHECK WITH METER WITH ENGINE…
- 3 Apr 2011
Radio Altimeter, faulty
WHEN THRUST IDLE IN DESCENT EICAS GEAR NOT DOWN CAME ON L RA YELLOW BOX FLASHING ON AND OFF. REPLACED LEFT RADIO ALTIMETER IAW MM. LANDING CONFIG SYS TEST…
- 14 Dec 2010
Lamp, inoperative
EMERGENCY EXIT EXTERIOR LIGHT INOP AT 2 LT MED, 4 RT MED AND AFT LT OVERWING. REPLACED LAMP, OPS GOOD.
- 14 Dec 2010
Oxygen Mask, leaking
F/O O2 MASK HARNESS LEAKS. REPLACED FIRST OFFICERS OXYGEN MASK ASSEMBLY. OPS NORMAL.
- 29 Aug 2010
Lamp, inoperative
L3 DOOR (EXTERIOR) EMERGENCY LIGHT INOPERATIVE. RELAMPED, OPS CHECKED GOOD.
- 29 Aug 2010
Lamp, inoperative
L2 DOOR EMERGENCY LIGHT INOPERATIVE (EXTERNAL). RELAMPED, OPS CHECKED GOOD.
- 19 Aug 2010
Controller, faulty
COCKPIT TEMP STILL UNCONTROLLABLE OVER 91 DEGREES IN AUTO. SUPPLEMENTAL DATA UPDATE WORKING WITH LM5719, REPLACED RT PACK TEMP CONTROLLER. DURING BITE TEST OF…
- 14 Jun 2010
Latch, failed
AFT LIFE RAFT IN OVERHEAD AISLE, DOOR LATCH NOT HOLDING. REMOVED RAFT. INSTALLED NEW BASE ASSEMBLY ON RIGHT SIDE. REPLACED SPRING ACTUATORS CMPT. OPS CK OKAY.…
- 15 Apr 2010
Frame, delaminated
LEFT WING AILERON, OTBD MOST, LOWER TRAILING EDGE, HAS SKIN DELAMINATING. CONDUCTIVE FRAME IS DELAMINATING FROM LOWER SURFACE OF AILERON, REMOVED ENTIRE…
- 29 Jan 2010
Light, inoperative
FOUND EMERGENCY EGRESS LIGHTING OUT AT FWD MID LAV DOOR. REPLACED EMERGENCY EGRESS LIGHTING STRIP IN FRONT OF MID LAV DOOR.
- 8 Jan 2010
Oven, odor
CREW REPORTED OVEN NR 010 FIRST CLASS GALLEY. ELECTRICAL ODOR. REMOVED POWER & ODOR DISSIPATED. OPERATED OVEN HALF AN HOUR, NO PARTICULAR ODOR NOTED. INSIDE…
- 15 Dec 2009
Oxygen Mask, leaking
F-O 02 MASK HARNESS LEAKS. FOUND HEAD HARNESS INFLATION COMPLETELY INOP DUE TO DISCONTINUITY OF BLADDER IN HARNESS. REPLACED MASK ASSY.
- 18 Oct 2009
Girt Bar, unsecure
DOOR 1R WILL NOT TURN ON SLIDE LIGHT GIRT BAR APPEARS TO BE OUT OF POSITION. SECURED GIRT BAR FWD BAR LOCK ON DOOR 1R. OPS CHECK NORMAL.
- 2 Oct 2009
Unknown, odor
CREW REPORT: THREE MINUTES PRIOR TO LANDING F/A REPORTED ACRID SMELL IN LAST THREE ROWS, GONE ON LANDING. SAMC TEXT: FA'S REPORTED ACRID RUBBER TYPE SMELL IN…
- 27 Aug 2009
Duct, damaged
CEILING & PANEL UNSECURE, RTFL. INSPECTED AREA AROUND OVERWING EXITS AND FOUND DAMAGE ON TOP OF OVAL MAIN DISTRIBUTION DUCT BETWEEN ROWS 17 AND 18. REMOVED…
- 13 Aug 2009
Lanyard, frayed
THE 2R MED EVAC SLIDE GIRT BAR LANYARD FRAYED. ACP ON WU K6903D, REPLACED SLIDE.
- 12 Jun 2009
Lanyard, unsecure
DOOR 1R SLIDE PACK RETAINER RING HANGING OUT OF COVER MAKING DOOR HARD TO CLOSE AND ARM. SECURED LANYARD AND DOOR CHECKS OKAY.
- 1 Jun 2009
Cover, broken
ONE (1) FT OF EEL COVER BROKEN AT SEAT 34C. REPLACED SECTION OF COVER.
- 31 May 2009
Blade, dented
CREW REPORT: ON PREFLIGHT FOUND DIME SIZED DENT ON LEADING EDGE OF LEFT ENGINE NR 26 1ST STAGE BLADE. BLENDED SMALL DING ON NR 1 ENGINE, BLADE NR 26 LEADING…
- 10 Jan 2009
Battery, discharged
FLOOR EEL LIGHTS INOP FROM ROW 23 TO REAR OF ACFT. REPLACED EEL BATTERY, SYS CHECKS GOOD.
- 10 Jan 2009
Battery, discharged
COVE EMERGENCY LIGHTING INOP FROM ROW 27 RT SIDE TO REAR AND EMERGENCY EXIT SIGN ABOVE AFT RT EXIT DOOR. REPLACED BATTERY, SYS CHECKS GOOD.
- 10 Jan 2009
Switch, stuck
FLOOR EMERGENCY EXIT EEL LIGHTS FROM ROW 28 TO REAR OF ACFT, AFT MOST CTR LINE EMERGENCY EXIT SIGN AND EMERGENCY EXIT SIGN ABOVE AFT LT EXIT DOOR ARE…
- 30 Jul 2008
Slide, low
NR 1 RT MED SLIDE PRESSURE INDICATOR IS AT LOW EDGE OF GREEN BAND. *S/D* UNKNOWN PRESSURE LEAK. REPLACED SLIDE ASSY, OPS CHECKED NORMAL.
- 16 Jul 2008
Cover, failed
NR 2 ENGINE OIL PRESSURE READING 0 ON THE QUANTITY OIL TEMP READING NORMAL. PSI BETWEEN 100-140. FLIGHT DIVERTED. *S/D* FOUND COVER SEAL DEFECTIVE AND BLOWN…
- 14 Jul 2008
Light, unsecure
CABIN EMER LT STRIP COMING UP NEAR ROW 13. SECURED STRIP, OPS CHECKED OK.
- 18 Mar 2008
Lamp, inoperative
EXTERIOR EMERGENCY LIGHT AT DOOR 2L INOP. REPLAMPED ASSY, OPS CHECKED NORMALLY. FOUND LAMP INOPERATIVE. REPLAMPED ASSY, OPS CHECKED NORMALLY.
- 18 Mar 2008
Lamp, inoperative
EXTERIOR EMERGENCY LIGHT AT DOOR 4R INOP. RELAMPED ASSY, OPS CHECKED NORMAL. FOUND AMP INOPERATIVE. RELAMPED ASSY, OPS CHECKED NORMAL.
- 18 Mar 2008
Slide, low
DOOR 1L MOUNTED ESCAPE SLIDE BOTTLE PRESSURE AT THE LOW END OF THE GREEN BAND AFTER 2 HOURS. FOUND SLOW LEAK ON SLIDE BOTTLE. REPLACED ESCAPE SLIDE ASSY.
- 18 Mar 2008
Sign, shorted
LAST EXIT SIGN IN FIRST CLASS INOP. FOUND SHORT IN SIGN. REPLACED EMER EXIT SIGN, OPS CHECKED NORMALLY.
- 6 Mar 2008
Lifter, worn
DOOR 4R IS HARD TO ARM. FOUND AFT LIFTER ASSY WORN. FOUND METAL BURRS ON SLIDER. FILED OFF BURRS AND CLEANED SLIDERS, DOOR ARMS AND DISARMS NORMALLY.
- 5 Dec 2007
Bulb, burned out
EMERGENCY LIGHT AT OVERHEAD BIN SEAT 5C. FOUND BURNED OUT BULB. REPLACED BULB ASSY FOR OVERHEAD BIN 5C.
- 5 Dec 2007
Lamp, inoperative
EEL LIGHT STRIP SEGMENT AFT OF SEAT 6B INOPERATIVE. FOUND LAMP ASSY BURNED OUT. REPLACED LIGHT ASSY (RELAMPED).
- 5 Dec 2007
Spring, broken
DOOR 4R MODE SELECTOR GUARD FOR SLIDE HAS BROKEN SPRING. REPLACED SELECTOR GUARD.
- 5 Dec 2007
Guard, out of adjust
DOOR 4L MODE SELECTOR GUARD DOES NOT PREVENT SLIDE HANDLE FROM BEING MOVED. FOUND SELECTOR GUARD OUT OF ADJUSTMENT. ADJUSTED SELECTOR GUARD, OPS CHECKED NORMAL.
- 20 Nov 2007
Slat, damaged
NR 3 OUTBOARD L/E SLAT HAS DAMAGE. NR 3 SLAT WAS DAMAGED AND REMOVED AND SENT TO SHOP FOR REPAIR.
- 14 Nov 2007
Girt Bar, out of adjust
FOUND DOOR 3R DIFFICULT TO ARM.
- 10 May 2007
Bottle, reads low
EMERGENCY ESCAPE LIGHT REMAINED EXTINGUISHED DURING SLIDE SQUIB TEST 2 ON SIDE 5 (05=L, 06=R). [SUP 06-06-07] FOUND LEFT OVERWING EVAC SLIDE BOTTLE PRESS LOW.…
- 25 Nov 2006
Connector, failed
EICAS MESSAGE MAIN BATTERY CHARGER DISPLAYED AND BATTERY DISCHARGE LIGHT EXTINGUISHED. ACCOMPLISHED CHRONIC REVIEW. FOUND DEFECTIVE PIN ON BATTERY CHARGER.…
- 27 Oct 2006
Oxygen Mask, leaking
OXYGEN MASK DEFECTIVE AT 1 (1=CAPT,2=1ST OFF,3=1ST OBS) CAPT O2 MASK LEAKS AIR WHEN RED HANDLES ARE SQUEEZED AND HEADSTRAP INFLATED. REPLACED DEFECTIVE…
- 17 May 2006
O-Ring, damaged
FOUND LOW BOTTLE PRESSURE FILLER VALVE O-RING FOUND DAMAGED AND LEAKING. REPLACED FILLER VALVE O-RING.
- 25 Dec 2005
Frame, damaged
AFT PIT STA 1600 FRAME HAS A DENT BETWEEN STR 25L AND 26L ON UPPER FLANGE. CUT OUT DAMAGE, INSURANCE CUT, INSTALLED DOUBLER REPAIR PER RE0-G10199, AND…
- 25 Dec 2005
Frame, damaged
AFT PIT STA 1520 FRAME HAS A DENT BETWEEN STR 25L AND 26L ON UPPER FLANGE. TRIMMED OUT DAMAGE TO FRAME, INSURANCE CUT, INSTALLED ANGLE REPAIR PER REO G10198…
- 25 Dec 2005
Frame, dented
AFT PIT FRAME STA 1500, STR 25L AND 26L HAS DENT UPPER FLANGE. CUTOUT DAMAGE AND REPAIRED PER REO G10197 AND EVA-50005.
- 25 Dec 2005
Frame, dented
AFT PIT STA 1580 FRAME HAS A DENT BETWEEN STR 25L AND 26L ON UPPER FLANGE. TRIMMED DAMAGE, INSURANCE CUT, INSTALLED ANGLE DOUBLER PER REO G-10195 AND EVA-50003.
- 14 Nov 2005
Slide, dislodged
DOOR 1L SLIDE PACK OFF OF DOOR. PER AMIS HISTORY, DURING THE PERIOD OF 1OCT&14NOV 2005, THERE WAS NO REPORTED PREVIOUS ACTIVITY RELATED TO THE 1L DOOR SLIDE…
- 1 Oct 2005
Light, burned
SMOKE COMING FROM LIGHT FIXTURE IN FORWARD GALLEY. ACCOMPLISHED VISUAL INSPECTION. FOUND NO BURNT WIRES NO CHAFFING, BALLASTS OK , NO ARCING, 0-2 GEN OK. OP…
- 7 Jan 2005
Shear Tie, corroded
AFT PIT SHEAR TIE CORRODED, BS 1440 STR 29L-30L. FABRICATED AND INSTALLED NEW SHEAR-TIE.
- 7 Jan 2005
Shear Tie, corroded
AFT PIT SHEAR TIE CORRODED, BS 1420 STR 28L-29L. FABRICATED AND INSTALLED NEW SHEAR-TIE.
- 7 Jan 2005
Frame, dented
AFT CARGO PIT FRAME UPPER FLANGE DENTED, BS 1340 STR 25L-26L. INSTALLED J ANGLE REPAIR.
- 7 Jan 2005
Frame, dented
AFT CARGO PIT FRAME UPPER FLANGE DENTED AT BS 1480 STR 25LTO 26L. INSTALLED J ANGLE REPAIR.
- 7 Jan 2005
Frame, dented
AFT CARGO PIT FRAME UPPER FLANGE DENTED AT BS 1380 STR 25L TO 26L. INSTALLED J ANGLE REPAIR.
- 7 Jan 2005
Frame, dented
AFT PIT STA 1520 FRAME HAS A DENT BETWEEN STR 25L AND 26L ON UPPER FLANGE. INSTALLED ANGLE REPAIR.
- 7 Jan 2005
Frame, dented
AFT PIT STA 1580 FRAME HAS A DENT BETWEEN STR 25L AND 26L ON UPPER FLANGE. INSTALLED ANGLE DOUBLER.
- 7 Jan 2005
Frame, dented
AFT PIT STA 1600 FRAME HAS A DENT BETWEEN STR 25L AND 26L ON UPPER FLANGE. INSTALLED DOUBLER REPAIR.
- 7 Jan 2005
Skin, damaged
FUSELAGE SKIN IS DAMAGED AT BS 1712 STR 14R. INSTALLED DOUBLER REPAIR.
- 7 Jan 2005
Frame, dented
AFT PIT FRAME STA 1500, STR 25L AND 26L HAS DENT UPPER FLANGE. INSTALLED DOUBLER REPAIR.
- 23 Jul 2004
Skin, bird strike
OUTBOARD END L/E SKIN DAMAGED BY BIRD STRIKE. REPLACED SECTION OF L/E SKIN.
- 4 Jan 2004
Shear Web, corroded
CABIN AFT FLOOR SHEAR WEB HAS UPPER SURFACE CORROSION IN AREAS FROM BS 1680-1720 FROM LBL 62 TO RBL 56.
- 4 Jan 2004
Attach Angle, corroded
ATTACH ANGLE FOR BS 940 FRAME BELOW LEFT FWD OVERWING DOOR CUTOUT CORRODED BETWEEN STR 16L.
- 4 Jan 2004
Floorbeam, corroded
FLOORBEAM HAS AREAS OF CORROSION FROM BL 0 TO RBL 60 AT BS 365.
- 4 Jan 2004
Floorbeam, corroded
CABIN FLOORBEAM AT STA 324 RBL 40 IS CORRODED BEYOND LIMITS.
- 4 Jan 2004
Frame, dented
FWD PIT FUSELAGE FRAME PRODUCTION SPLICE HAS A DENT ON INNER FLANGE AT STA 580 ABOVE STR 26L.
- 4 Jan 2004
Floorbeam, corroded
CABIN FLOORBEAM T-CAP CORRODED ON PREVIOUS REPAIR DOUBLER AT BS 1640, RBL 48-56.
- 14 Nov 1996
Inflation Tube, chafed
DURING TIME CONTROLLED OVERHAUL, SLIDE UNIT INFLATABLE SHOWS CHAFE DAMAGE CAUSED BY THE PRESSURE RELIEF VALVE SCREWS. HOLES ARE WORN THROUGH THE CHAFE COVER…
- 22 Jul 1996
Battery Pack, failed
EMERGENCY ESCAPE FLOOR LIGHTING INOPERATIVE. FINAL 10 FEET IN AFT SECTION. REPLACE EMERGENCY ESCAPE LIGHTING BATTERY PACK. OPERATION CHECKS NORMAL.
- 16 Oct 1995
Eel Lamp, failed
SLIDE EMERGENCY LIGHT INOP AT DOOR ONE LEFT. RELAMPED, CHECKS OK.