N575UA
Airbus A340-642 FAA →
earlier registrations
1 past record
NTSB
- 29 Oct 1999
incident, Chicago IL
service difficulty reports
117 reports
- 20 Jan 2014
Generator, tripped
CREW REPORTS LT GENERATOR TRIPPED OFF & WILL NOT RESET.
- 11 Dec 2013
Handset, inoperative
AFT HANDSET PA INOPERATIVE, REPLACED AFT HANDSET. OPERATIONS CHECKED GOOD. AIRCRAFT OK TO CONTINUE.
- 10 Oct 2013
Lens, broken
1ST CLASS EMERGENCY EXIT FLOOR LIGHT CLEAR COVER BROKEN & NEEDS TO BE REPLACED. REPLACED EMERGENCY EXIT LIGHT STRIP CLEAR LENS COVER AS REQUIRED.
- 9 Oct 2013
Floor Panel, damaged
FLIGHT ATTENDANT REPORTS FLOOR SOFT AT ROW 4. MUSHY FLOOR PANEL FWD CABIN FLOOR. BEGAN REMOVAL OF FLOOR PANEL IN FWD CABIN, ALL SCREWS REMOVED. PANEL LEFT IN…
- 29 Sep 2013
Connector, unsecure
4L FLT ATTENDANT HANDSET PHONE DOES NOT RING OR LIGHT UP. RESET CONNECTOR FOR FLT ATTENDANT HANDSET AT 4L HANDSET, OPERATIONS CHECKED GOOD. LIGHT COMES ON &…
- 22 Sep 2013
Clamp, unsecure
BS 1020 LT SIDE EMERGENCY EXIT LIGHT POWER SUPPLY WIRING CLAMP DISBONDED FROM DUCT ASSEMBLY. SECURED WIRING CLAMP.
- 2 Sep 2013
Bleed Valve, faulty
SMELL OF TURBO ENGINE OIL IN CABIN AFTER APU STARTED & PACKS OPERATED AT GATE SFO. APU BLEED VALVE DEF INOPERATIVE IAW MEL PROCEDURE.
- 31 Aug 2013
Scavenge Pump, faulty
SMOKE IN COCKPIT. AMBER. MAX TEMP 163. EPCS CLEAN PROPLEM WITH OIL SYSTEM. ACCOMPLISHED BLOCK 22 OIL SCAV PUMP REPLACED ON PTT SEQ 4192004. OIL TEMP GOOD ON…
- 31 Aug 2013
Oil System, overheated
NR 1 ENGINE OIL TEMPERATURE HIGH.
- 30 Aug 2013
Motor, faulty
FOUND PRESSURE LEAK & SQUEAL AROUND CAPTAINS WINDSHIELD WIPER MOTOR. REPLACED CAPTAINS WIPER MOTOR IAW AMM. LEAK CHECKED AND OPERATIONS CHECKED GOOD.
- 29 Aug 2013
Motor, defective
FOUND PRESSURE LEAK & SQUEAL AROUND CAPTAIN`S WINDSHIELD WIPER MOTOR. REPLACED CAPTAIN`S WIPER MOTOR IAW AMM, LEAK CHECKED & OPERATIONS CHECKED GOOD.
- 29 Aug 2013
Hinge, broken
LAVATORY DOOR AT 2L HINGE BROKEN. DOOR RESECURED.
- 23 Aug 2013
Fastener, missing
TWO EACH FASTENERS MISSING FROM RT WING TO BODY FAIRING. REPLACED FASTENER ON RT WING TO BODY PANEL LEADING EDGE. REMAINING MISSING FASTENER IS NOT IN LEADING…
- 23 Aug 2013
Light, inoperative
EMERGENCY LIGHTING FLOOR EMERGENCY EXIT LIGHT STRIP BY DOOR 2L LAVATORY IS INOPERATIVE & PULLED FROM FLOOR. SECURED STRIP BACK IN PLACE & REPLACED COVER.
- 20 Aug 2013
Cap, missing
FLOOR MOUNTED EMERGENCY EGRESS LIGHTS MISSING ENDCAPS. REPLACED FLOOR MOUNTED EMERGENCY EGRESS LIGHTING END CAPS.
- 7 Aug 2013
Cover, unsecure
AFT END OF EMERGENCY LIGHT AFT CABIN COVER COMING OFF. SECURED COVER.
- 15 Jun 2013
Charger, faulty
AUXILIARY POWER UNIT WILL NOT START. PLACARDED AUXILIARY POWER UNIT INOPERATIVE IAW MEL. AUXILIARY POWER UNIT HAS FUEL NO IGNITION. REPLACED BATTERY, VOLTAGE…
- 29 Apr 2013
Plate, missing
VERY LOUD AIR NOISE FROM AIR DUCTS NEAR DOOR 2. INTERFERES WITH CREW COMMUNICATION. FOUND SECTION OF DIFFUSER DUCT PLATE MISSING, FWD OF PROJECTOR NR 3.…
- 22 Apr 2013
Skin, dented
LEFT FUSELAGE SKIN HAS A DENT 1INCH WIDE BY 0.029 INCH DEEP AT BS 600, S17L. DENT IS WITHIN LIMITS PER SRM 53-00-01. EDDY CURRENT INSPECTION REVEALED NO…
- 22 Apr 2013
Skin, dented
EXTERNAL FUSELAGE SKIN HAD SEVERAL DENTS BS 600-640 S14-19L. FOUND OUT OF LIMITS. REPAIRED IAW REO EVA G-09691, REV A IAW EVA 40072.
- 20 Apr 2013
Stiffener, damaged
LEFT WING PNEUMATIC DUCT, I/B DUCT CLAMP BRACKET LOCATED BEHIND NR 5 SLAT I/B AUX TRACK, WEARING INTO VERTICAL STIFFENER ON FRONT SPAR. REMOVED AND REPLACED…
- 18 Apr 2013
Skin, dented
FUSELAGE SKIN DENTED AT BS 1620 BELOW S18R. AT C CHECK DENT WAS FOUND TO BE OUT OF LIMITS AND A REPAIR DOUBLER WAS INSTALLED IAW ECRA 5330-045 12.
- 13 Apr 2013
Skin, dented
EXTERIOR BOTTOM RIGHT R2 DOOR DENT AND FRESH PAINT MISSING DOWN TO BARE METAL IN L SHAPE. INSTALLED INTERIM REPAIR AT BS 1617 JUST ABOVE S18R PER ECRA…
- 13 Apr 2013
Skin, dented
EXTERIOR FUSELAGE SKIN DENTED AT S 1622 ABOVE S19R. EVALUATED DENT PER SRM 53-00-01, FIG 101 AND FOUND TO BE WITHIN LIMITS. DENT HFEC INSPECTED, NO CRACKS.…
- 13 Apr 2013
Skin, dented
BOTTOM R2 DOOR DENTED AND FRESH PAINT MISSING DOWN TO BARE METAL IN SHAPE L. INSTALLED INTERIM REPAIR AT BS 1617 JUST ABOVE S18R PER ECRA 5330-04512.
- 4 Apr 2013
Floor Panel, damaged
FORWARD LAVATORY FLOOR PANEL IS SOFT AND SPONGY. REPAIRED PER CMM 25-40-23 AND CE-50-25-40-01-JD.
- 2 Apr 2013
Wedge, dented
RIGHT WING NR 8 SLAT HAS A SMALL DENT ON THE T/E WEDGE THREE FEET FROM I/B END. MEASURED DENT AND FOUND IT TO BE WITHIN LIMITS OF SRM 57-43-02 DETAIL 3.
- 2 Apr 2013
Wedge, dented
RIGHT WING NR 6 SLAT HAS A SMALL DENT ON THE T/E WEDGE 10 INCHEC FROM OUTBOARD EDGE. MEASURED DENT AND FOUND IT TO BE WITHIN LIMITS OF SRM 57-43-02 DETAIL 3.
- 31 Mar 2013
Skin, damaged
FUSELAGE SKIN DAMAGED BS 470 S24R. REPAIRED IAW SRM 53-00-01 REPAIR 3 TABLE 5.
- 31 Mar 2013
Skin, damaged
DIMPLE LOCATED AT RIGHT SIDE OF ACFT AT APPROX 28.75 IN BEHIND BS 440 AND 14.5 INCH BELOW RVS BOTTOM.
- 31 Mar 2013
Skin, dented
DENT ON RIGHT SIDE OF ACFT, APROX 37 INCHES AFT BS 440 AND 13.75 INCHES FROM BOTTOM OF RVSM. INSTALLED CATEGORY B REPAIR IAW SRM 53-00-01 REPAIR 3.
- 19 Feb 2013
Diffuser, misinstalled
EXCESSIVE NOISE IN FLT DECK AND AT ROWS 10-12. AIRFLOW AND NOISE VERYLOUD IN CABIN ROWS 10-12. MT 21-22-00 FOUND 4-5 DECIBLE DROP WITH RT RECIRC FAN BEING…
- 24 Jan 2013
Unknown, odor
EQUIPMENT FAN FAILED CREATED A ELECTRICAL SMELL IN CABIN. BPCU FAULTS AS FOLLOWS LEFT GEN POWER STS UNDER VOLT TRIP, OPPOSITE BUS OVERLOAD AND GCU 58. REF FIM…
- 26 Nov 2012
Spring, damaged
FLIGHT ATTENDANT REPORTED THE AFT EMERGENCY LIGHT SWITCH SPRING IS SPRUNG. REPLACED EVAC PANEL. OPS CHECK OK.
- 12 Oct 2012
Light, inoperative
EMERGENCY AISLE PATH LIGHTING STRIP INOP AT SEAT ROW 40C. REMOVED AND REPLACED THE FLOOR AISLE PATH LIGHT STRIP AT ROW 40C, COMPLIED WITH OPERATIONAL CHECK OF…
- 11 Oct 2012
Light, inoperative
EMERGENCY AISLE PATH LIGHT INOPERATIVE AT SEAT ROW 40C. EMERGENCY FLOOR LIGHT END CAP MISSING. INSTALLED END CAP.
- 30 Sep 2012
Inverter, faulty
STANDBY POWER TEST GENERATES A 'STBY INVERTER' STATUS MSG. REPLACED STATIC INVERTER AS PER MM, OPS CHECK NORMAL.
- 24 Jul 2012
Skin, dented
EXT BOTTOM RIGHT DOOR 2R DENT AND FRESH PAINT MISSING DOWN TO BARE METAL. DENT IS FWD OF D4R S17 AND 18 FWD OF STA 1640 AFT OF 1596. 2.25W X .046 DEEP.…
- 16 Apr 2012
Lanyard, misrouted
DOOR 3 LEFT LANYARD IS ON WRONG SIDE. ROUTED LANYARD CORRECTLY.
- 21 Mar 2012
Bolt, missing
DURING DOOR 1 RT SLIDE CHANGE FOUND GATE ROD END BOLT MISSING. INSTALLED BOLT, WASHERS, BUSHING AND NUT. ADJUSTING NUT WAS TIGHT, NO RIG REQUIRED.
- 16 Mar 2012
Heat Exchanger, ruptured
PRESSURIZATION LOSS, RTFL LEFT SECONDARY HEAT EXCHANGER HAS RUPTURED. REPLACED RUPTURED HEAT EXCHANGER ON LEFT PACK AND DAMAGED CONDITIONED AIR DUCT &…
- 11 Feb 2012
Door, open
COCKPIT DOOR OPENED ON FINAL APPROACH BY ITSELF. NO PRIOR PROBLEMS DURING FLT. ACCOMPLISHED ELECTRIC STRIKE SYSTEM TEST AS PER MM. NO FAULTS NOTED. SYS CKS…
- 9 Nov 2011
Structure, cracked
FERRY FROM SEA TO SFO FOR REPAIR BY SFO. DOOR 2R UPPER HINGE CUTOUT IS CRACKED APPROXIMATELY 0.28". ACP WALK AROUND OF ACFT. MED 2R. UPPER HINGE CUT OUT CRACK…
- 21 Sep 2011
Girt Bar, dirty
THE 1R DOOR WILL NOT ARM HANDLE IS JAMMED. FOUND DEBRIS IN GIRT AREA, ARMING OPS CHECKED GOOD.
- 14 Sep 2011
Control Unit, faulty
DURING FLIGHT, F/A REPORTED THAT DURING TAXI OUT CABIN LOST ALL LIGHTS & VIDEO TWICE-REPEAT. REPLACED BPCU. TAXI AIRCRAFT WITH FLT CREW SETUP OF LT ENGINE…
- 9 Aug 2011
Skin, dented
LT HORIZONTAL STAB HAS A DENT, UNDER SIDE APPROX STA 135. MEASURES 2.25 X 1.375. FOUND ON ARRIVAL. DENT LOCATED AT STA 135.249- 12.25\ AFT OF PANEL L/E- REF…
- 9 Aug 2011
Skin, damaged
LT HORIZONTIAL STAB HAS A DENT UNDERSIDE, APPROX STA 192 MEASURES 3 X 1.375. FOUND ON ARRIVAL. DENT LOCATED STA 191.249- 8.5\ AFT OF PANEL L/E- REF SRM…
- 9 Aug 2011
Skin, dented
LT HORIZONTIAL STAB HAS A DENT ON THE UNDERSIDE, APPROX STA 195 MEASURES 1.25 X 1.25. DENT LOCATED AT STA 193.249- 10.34" AFT OF PANEL L/E- REF SRM 55-10-01…
- 2 Aug 2011
Seal, leaking
CREW REPORTS LOUD NOISE AT DOOR 2R. CHECKED DOOR 2R SEAL & SEALING AREA. FOUND ALL IN SERVICEABLE CONDITION. PRESSURIZED ACFT TO 4.5 PSID. HAD AUDIBLE LEAK AT…
- 12 Jun 2011
Acm, malfunctioned
HEAVY VIBRATION AND NOISE IN CRUISE FL 410 WITH RT PACK STANDBY NORMAL AND LT PACK RETURNED TO AUTO. LT ACM WAS REPLACED. RIGHT PACK PUTS OUT VERY LOW AIR…
- 10 Jun 2011
Flex Hose, out of position
LOUD NOSE & MAIN GEAR NOISE. STARTED AT 17500 290 KTS. CONSTANT AIRFRAME VIBRATION NOISE. NOISE WENT AWAY WHEN THROTTLE PULLED BACK, IT WAS LIKE A MOTOR GOING…
- 9 Jun 2011
Module, faulty
GEAR DISAGREE LIGHT ILLUM. DEBRIEFED CREW AND NOTED GEAR AMBER LIGHT ILLUMINATED WITH ASSOCIATED GEAR DISAGREE EICAS MSG. THIS HAPPENS 3X DURING GEAR CYCLES…
- 16 May 2011
Sill, corroded
CORROSION FOUND ON OUTER CHORD OF LOWER MAIN SILL OF THE AFT CARGO DOOR BS 1440 TO BS 1460 AT STRINGER 27R. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE & ACP…
- 15 May 2011
Crease Beam, cracked
MED R4 CREASE BEAM (HOCKEY STICK) CRACKED AT STA 1681 RBL. REMOVED DAMAGE AT BS1683 & BS 1639. ACP NDT OF CHORD & FASTENER HOLES REF NDT MANUAL, NO DEFECTS.…
- 15 May 2011
Stringer Splice, corroded
AFT CARGO PIT PRODUCTION SPLICE CORRODED AT STR 29L AT STA 1465, SPLICE GOES FROM STA 1453 TO STA 1465. MAJOR REPAIR ACCOMPLISHED: REMOVED CORRODED STRINGER…
- 15 May 2011
Frame, corroded
CORROSION ON FRAME AT STA 1420, BETWEEN S-30 AND STR 28L. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION FROM THE FRAME. ACP NDT OF FASTENER HOLES & BLENDED…
- 13 May 2011
Structure, corroded
CORROSION AT STA 324 PREVIOUS REPAIR RBL 52 - 70 CORR. MAJOR REPAIR ACCOMPLISHED: REPAIRED PER DETAILED INSTRUCTIONS ON EA PD57-53-116 AND UAL EVA 80818…
- 13 May 2011
Ram Air Turb, defective
RAT FAILED OPS CHECK ON TC 5R29I3046, FOUND FILTERS CONTAMINATED, FILTER REPLACEMENT REQUIRED. REMOVED AND INSTALLED NEW RAT HYDRAULIC PUMP IAW B757 MM, OPS…
- 10 May 2011
Floor Panel, corroded
AFT CARGO PIT FLOOR PAN JUST INBOARD OF CARGO DOOR HAS SEVERAL AREAS OF EROSION AT FLOOR PAN EDGES AND THROUGH OUT PAN. STARTED FLOOR PANEL REMOVAL FOR…
- 6 May 2011
Floorbeam, corroded
CORROSION AT STA 365 FROM RBL 20 - 56 ON FLOORBEAM (CORR TASK #CP53-222-01I). MAJOR REPAIR ACCOMPLISHED: REPLACED T-CAP STA 365 FROM RBL 00 TO RBL 65,…
- 6 May 2011
Stringer, corroded
CORROSION AT STA 563 ON STR 27R IN FWD CGO BILGE AREA (WITHIN 20 INCHES OF THE CARGO DOOR, CORR TASK #C53-119-02). MAJOR REPAIR ACCOMPLISHED: REPLACED…
- 4 May 2011
Feeder Cable, burned
GALLEY POWER FEEDER CABLES BURNED AND BROKEN AT PREVIOUS SPLICE STA 1600-1620, STR 3R. REPAIRED THE AMP COPPER, ALUMINUM SPLICE OF THE POWER FEEDER WIRES FOR…
- 4 May 2011
Intercostal, corroded
CORROSION ON INTERCOSTAL BOTH SECTIONS UNDER R4 DOOR. MAJOR REPAIR ACCOMPLISHED: CORROSION OUT OF LIMITS, REPLACED INTERCOSTAL STA 1640 - 1660 PER SRM.
- 3 May 2011
Floor Support, damaged
AFT CARGO RT FLOOR SUPPORT DAMAGED BY OLD FLOORBOARD REPAIR. APPROX RBL 22, STA 1408. MAJOR REPAIR ACCOMPLISHED: REMOVED STRINGER FROM STA 1345 - 1445 RBL…
- 20 Apr 2011
Floorbeam, corroded
AFT CABIN FLOORBEAM CORRODED AT STA 1660, RBL 3 TO RBL 5. REPLACED FLOORBEAMS FROM RBL 3 TO RBL 24 PER SRM. ACP ON PEMCO NR 2537N00118, BY MECH AND INSPECTOR.
- 25 Mar 2011
Structure, damaged
CREW REPORT: LEFT ELEVATOR TRAILING EDGE BY FUSELAGE SMALL AREA OF DAMAGE. SAMC TEXT: DAMAGE IS 8 INCHES FROM INBD EDGE OF LEFT ELEVATOR, THE DAMAGE IS A DENT…
- 11 Mar 2011
Computer, faulted
CREW REPORTED ELEVATOR FORCES ABNORMALLY HEAVY. RT SYSTEM ELEV PCA AT LT ELEVATOR (OTBD) IS LEAKING AT ROD END. OPERATED AILERONS. NO LEAKS NOTED. SUSPECT…
- 28 Feb 2011
Bracket, inoperative
INTERPHONE HANDSET DOOR 1L WON'T STAY SECURED. DOOR 1L HANDSET IS SECURE. DOOR 4L HANDSET INTERIM SECURED TO CRADLE. HANDSET IS CONSIDERED INOP. REPLACED CUP…
- 12 Jan 2011
Feeder Cable, faulty
EMERGENCY LIGHT STRIP AT 14ABC DAMAGED. EMERGENCY LIGHTS ARE INOP FROM ROW 9 TO ROW 14. EMERGENCY LIGHT PULLED UP AND CUT IN HALF AY ROW 14. REPLACED CABLE…
- 27 Dec 2010
Actuator, faulty
HEAVY ELEVATOR CONTROL FORCES NEEDED. IAW THE FLIGHT CREW ELEVATOR NEEDED MORE PRESSURE THEN NORMAL TO MOVE. REPLACED ELEV FEEL ACTUATOR IAW MM, LEAK CHECK…
- 24 Nov 2010
Control Column, stiff
STICK FORCES VERY HEAVY. PITCH CONTROL ON GROUND TEST AND DURING LANDING FLARE OUT VERY HEAVY. ACCOMPLISHED ELEVATOR FEEL SYSTEM FORCES TEST PER MM. CHECKED…
- 24 Sep 2010
Fan, malfunctioned
EQUIP COOLING STATUS MESSAGE ACCOMPANIED W-HOT ODOR. NR1 E&E COOLING FAN MAKING EXCESSIVE NOISE DURING OPERATION. REPLACED COOLING FAN. ALSO CHANGED COOLING…
- 18 Jul 2010
Extinguisher, leaking
AFT H2O FIRE EXTINGUISHER LEAKING. REPLACED FIRE EXTINGUISHER.
- 18 Jul 2010
Extinguisher, leaking
FWD H2O FIRE EXTINGUISHER LEAKING. REPLACED H20 FIRE EXT FWD POSITION AT DOOR 1 LT.
- 20 Jun 2010
Wire, open
GALLEY CHILLER INOP AT R1 DOOR GALLEY G1B. C/B C3023 ON P37 PANEL WAS TRIPPED. C/B RESET BUT WOULD TRIP AFTER APROX 10 SEC. WITH C.B FOR CHILLER ON FWD GALLEY…
- 13 Jun 2010
Lens, cracked
SMALL SECTION OF EMERGENCY STRIP AT LOCATION 14C HAS A CRACK IN PLASTIC LENS. INTERIM REPAIR, TAPED THE CRACK SECTION OF EMERGENCY STRIP PLASTIC COVER, SYS…
- 2 Apr 2010
Inverter, inoperative
FLOOR EMERGENLCY LIGHT INOP ROW 9 THRU 15. REPLACED EMERGENCY LIGHT POWER INVERTER M10827. FLOOR EMERGENCY LIGHTS ROWS 9 - 15 CK OK.
- 14 Aug 2009
O-Ring, leaking
LOW BOTTLE PRESSURE. LEAKING AT BURST DISK O-RING. REMOVED & REPLACED O-RING.
- 1 Jul 2009
Bottle, reads low
DOOR 1L SLIDE PSI LOW. EVACUATION SLIDE BOTTLE PRESS (LOW, ZERO) AT DOOR 1. REPLACED DOOR MOUNTED SLIDE RAFT REF MM 25-66-01.
- 30 Dec 2008
Fuel/Oil Cooler, failed
LOST LT GENERATOR. FUEL COOLED OIL COOLER REPLACED. UNIT SO FAR PASSING TEST. ONLY RAN 100 PSI BUT NO LEAKS DETECTED.
- 21 Aug 2008
Bulb, inoperative
EXTERIOR EMERGENCY LIGHT BY DOOR 2L AND LT OVERWING ESCAPE HATCH FWD LIGHT INOP. FOUND BULBS INOP. RELAMPED BULBS, ALL OPS TEST NORMAL.
- 9 Apr 2008
Video Unit, odor
F/A REPORTS ACRID ODOR AND HAZE FROM VIDEO SYSTEM PROG. VIDEO SYSTEM WAS CLEANED AND RETESTED WITH NO SMELL, NO REPEATS.
- 27 Mar 2008
Sensor, faulty
FOUND DOOR 2R SLIDE LIGHT INDICATOR INOP. FOUND A WEAK PROX SENSOR. REPLACED PROX SENSOR 585-3162 AT DOOR 2R AT AFT POSITION.
- 19 Mar 2008
Lamp, inoperative
EXTERIOR EMERGENCY LIGHTS INOP AT DOOR 4L AND 4R. FOUND LAMP INOPERATIVE. REPLACED LAMP, CHECKED OK.
- 26 Jan 2008
Bottle, low pressure
THE 1L DOOR ASSIST BOTTLE NOT IN GREEN BAND. REPLACED DOOR ASSIST BOTTLE 1L DUE TO CHRONIC LEAKING.
- 29 Dec 2007
Trim System, out of rig
RUDDER TRIM OUT OF LIMITS. FOUND RUDDER RIG OFF SLIGHTLY. RE-RIGGED ENTIRE RUDDER SYSTEM AND STANDBY RUDDER LVDT. NO HISTORY SINCE ORIGINAL.
- 10 Jul 2007
Light, damaged
FOUR EEL LIGHTING END CAPS MISSING THROUGHOUT CABIN. [08-17-07] REPLACED MISSING END CAPS.
- 12 Aug 2006
Warning Message, illuminated
LEFT AUX PITOT MESSAGE AND LIGHT CAME ON DURING CLIMBOUT. RELAY REPLACED WITH NEW UNIT WHICH TRIGGERED FAULTS WITHIN RELAY OR AT RELAY CONNECTIONS. A…
- 8 Jul 2005
Radar, failed
WEATHER RADAR FAILED JUST AFTER TAKEOFF. FLIGHT DIVERTED DUE TO THUNDERSTORMS. MAINTENANCE REPLACED THE RADAR ANTENNA ASSY (P/N 2041444-0401). THE COMPONENT…
- 24 Nov 2004
Crease Beam, corroded
AFT PIT BETWEEN STA 1180L AND STA 1200L AT STRINGER 17L, CREASE BEAM WEB HAS CORROSION. REPLACED CREASE BEAM WEB.
- 24 Nov 2004
Frame, dented
AFT PIT FRAME DENTED ON UPPER FLANGE AT STA 1520 AND STR 26L. INSTALLED NESTED J ANGLE REPAIR.
- 24 Nov 2004
Frame, dented
AFT PIT FRAME DENTED AT UPPER FLANGE AT STA 1440, STR 26L. REPAIRED FRAME WITH J ANGLE REPAIR SECTION.
- 24 Nov 2004
Frame, dented
AFT PIT FRAME DENTED UPPER FLANGE AT STA 1420, STR 26L.
- 24 Nov 2004
Frame, dented
AFT PIT FRAME DENTED UPPER FLANGE AT STA 1500 AND STR 26L. INSTALLED J ANGLE REPAIR DOUBLER.
- 24 Nov 2004
Frame, dented
AFT PIT FRAME DENTED ON UPPER FLANGE STA 1400 AND STR 26L. INSTALLED NESTED J ANGLE REPAIR.
- 24 Nov 2004
Skin, damaged
RT EXT FUSELAGE AT STA 595 AND STR 8R, REPAIR DOUBLER AREA DAMAGED, CUTOUT CORNERS HAVE INSUFFICIENT RADII. *S/D* REMOVED EXISTING REPAIR DOUBLER, ENLARGED…
- 24 Nov 2004
Strap, corroded
AFT PIT AFT STA 1400L BETWEEN STR 28L AND 29L, PRODUCTION SPLICE PLATE CORRODED. SPLICE STRAP REMOVED AND REPLACED.
- 24 Nov 2004
Skin, damaged
STATION 1380 LBL 19, INTERNAL SKIN DOUBLER CORRODED BEYOND LIMITS IN AFT PIT.
- 19 Nov 2004
Firewall, gouged
NR 2 PYLON I/B FIREWALL BULKHEAD IS GOUGED.
- 18 Nov 2004
Floorbeam, corroded
CABIN FLOORBEAM STA 324 AND RBL 53 HAS CORROSION. REMOVED DAMAGED T CAP SECTION AND INSTALLED NEW SECTION SPLICED WITH DOUBLERS.
- 16 Nov 2004
Skin, damaged
FUSELAGE SKIN HAS LIGHTNING STRIKE DAMAGE. DAMAGED SKIN WAS CUTOUT AND A DOUBLER REPAIR WAS INSTALLED.
- 11 Nov 2004
Floorbeam, corroded
CABIN FLOORBEAM STA 1640 HAS CORROSION RBL 44 TO 52, UPPER CAP. CORRODED SECTION REMOVED AND A FLOORBEAM DOUBLER REPAIR WAS INSTALLED.
- 10 Nov 2004
Floorbeam, buckled
CARGO PIT FLOOR JUST IN FRONT OF DOORWAY IS SEVERELY BUCKLED.
- 18 Feb 2004
Skin, dented
EXTERNAL FUSELAGE SKIN HAS SEVERAL DENTS AT BS 600-640, AND STR 14L TO 19L. MAJOR REPAIR ACCOMPLISHED. INSTALLED SKIN SPLICE DOUBLER REPAIR.
- 6 Jan 2002
Stator, failed
NUMBER 1 ENGINE COMPRESSOR STALL. FOUND 10TH STAGE STATOR FAILED. THIS STATOR HAD THE NEW GOLD/NICKEL BRAZE MATERIAL AS PER PWA SERVICE BULLETIN. STATOR HAD…
- 4 Aug 2001
Engine, vibration
LEFT ENG VIB IND FLUCTUATES BETWEEN 1.0 & 1.5 IN CRUISE AT 350. VIB FELT THROUGHOUT AIRCRAFT AND INCREASES INVERSELY WITH THROTTLE. FOUND METAL IN THE TAILPIPE.
- 11 Jun 2001
Skin, dented
FUSELAGE DENTED STA 1688-1701, STR 18R. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER AND TRIPLER.
- 28 Oct 1999
Elevator, fluttered
FLIGHT DIVERTED TO ORD UNDER AMBER ALERT DUE TO A CONTROL FLUTTER PROBLEM. CONCURRENT REPORTING OF UNITED'S FINDINGS TO FAA IS ONGOING THROUGH UNITED'S FLIGHT…
- 4 Oct 1999
Pump, overheated
LANDED UNDER AMBER ALERT DUE TO A NR 2 HYDRAULIC SYSTEM FAILURE. S/D, THE PARTING SURFACE OF THE ENGINE DRIVEN PUMP FAILED WHEN THE PUMP OVERHEATED, ALLOWING…
- 26 Feb 1999
Wire, failed
RETURNED TO FIELD AT ORD UNDER AMBER ALERT DUE TO A LEADING EDGE ASYMMETRY LIGHT. *S/D* FOUND A WIRE ASSOCIATED WITH THE LEADING EDGE SLAT SYSTEM SHORTING TO…
- 20 Jan 1999
Warning, activated
DIVERTED TO PHX UNDER AMBER ALERT DUE TO FLAP/SLAT PROBLEM. *S/D* CHECKS OF THE SYSTEM DID NOT REVEAL A ROOT CAUSE, AND PROBLEM COULD NOT BE DUPLICATED.…
- 15 Jan 1999
Switch, failed
OXYGEN MASKS DEPLOYED ON TOUCH DOWN. *S/D* RECEPTICLE ON S119 ALTITUDE PRESSURE SWITCH WAS FOUND DETACHED FROM SWITCH BODY. REPLACED S119 AND PERFORMED…
- 8 Oct 1997
Light, inoperative
FLOOR EEL LIGHT INOP AT ROW 13. RECONNECTED EEL LIGHT STRIP.
- 25 Sep 1997
Charger, inoperative
EEL LIGHTS AT ROW 19 THROUGH 24 DO NOT COME ON. REPLACED CHARGER M10770. SYSTEM CHECKS OK.
- 19 Sep 1997
Battery, discharged
FLASHLIGHT AT DOOR 1L INOP, BATTERY DEAD. REPLACED BATTERY.
- 18 Feb 1997
Battery, discharged
EMERGENCY EXIT LIGHT AT ENTRY DOOR 2L INOP. REPLACED BATTERY AND CHARGER AT DOOR 2L, OPERATION CHECKS NORMAL.
- 30 Dec 1996
Battery, discharged
CEILING EMERGENCY EGRESS LIGHTING AT OVERWING POSITION INOP. REPLACED BATTERY PACK, OPERATION CHECKS NORMAL.