N574RP
2004 Embraer EMB-145LR standard FAA →
aircraft radio
earlier registrations
1 past record
- 2004
service difficulty reports
39 reports
- 17 Jun 2016
Marker, missing
MAIN CABIN DOOR UPPER RT CORNER RED LINE UP MARK IS MISSING. REMARKED MAIN DOOR ALIGNMENT MARKS IAW AMM 52-11-00.
- 15 Mar 2016
Seal, damaged
MAIN CABIN DOOR IS HARD TO OPEN RT BEFORE THE DOOR GETS COMPLETELY OPEN, IT MAKES A LOUD POP SOUND. REPAIRED FRAME SEAL IAW AMM 52-00-04. CLEANED, LUBED…
- 20 Mar 2015
Shear Tie, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 24 AND STRINGERS 16R AND 17R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.
- 20 Mar 2015
Shear Tie, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 25 BETWEEN STRINGERS 15R AND 16R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.
- 20 Mar 2015
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE CENTER OMEGA BEAM AT FRAME 20. THE BEAM WAS REPLACED IAW SRM 51-40-02.
- 20 Mar 2015
Shear Tie, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 24 BETWEEN STRINGERS 15L AND 16L. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.
- 20 Mar 2015
Shear Tie, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 26 AND STRINGERS 15R AND 16R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.
- 20 Mar 2015
Support, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE RT INBD BEAM SUPPORT BETWEEN FRAME 47 AND 48. THE BEAM WAS REPLACED IAW SRM 53-23-02.
- 20 Mar 2015
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE RT OMEGA BEAM BETWEEN FRAMES 24 AND 25. THE BEAM WAS REPLACED IAW SRM 53-00-10.
- 20 Mar 2015
Threshold, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE CARGO DOOR THRESHOLD BETWEEN FRAME 65 AND FRAME 68. THE THRESHOLD WAS REPLACED IAW SRM 51-40-02.
- 20 Mar 2015
Support, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE NLG UPLOCK SUPPORT. THE SUPPORT WAS REPLACED IAW SRM 51-40-02.
- 20 Mar 2015
Door Frame, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE "L" SHAPE FRAME 65 CARGO DOOR STOP. THE "L" SHAPE FRAME 65 DOOR STOP WAS REPLACED IAW SRM 53-31-04.
- 20 Mar 2015
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE LT OMEGA BEAM BETWEEN FRAME 24 AND 25. THE BEAM WAS REPAIRED IAW SRM 53-00-10.
- 20 Mar 2015
Threshold, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE SERVICE DOOR THRESHOLD. THE THRESHOLD WAS REPAIRED IAW SRM 53-21-02.
- 20 Mar 2015
Tee Fitting, corroded
DURING INSPECTION, THE FRAME 65 TEE FITTING WAS FOUND TO BE CORRODED. THE FITTING WAS REPLACED IAW SRM 51-40-02.
- 14 Jul 2014
Transducer, unsecure
CREW REPORTED THAT UPON LANDING THAT THEY EXPERIENCED REDUCED BRAKING ACTION & THAT THE BRAKES SEEMED TO BE GRABBING. MX SECURED THE NR 4 WHEEL SPEED…
- 12 Jul 2014
Electronic Unit, failed
THE CREW REPORTED THAT AFTER TAKEOFF THAT THE LG WOULD NOT RETRACT & THEY HAD A LG AIR & GND FAIL MSG. THE CREW ALSO REPORTED THAT THEY RECEIVED A SPOILER…
- 11 Jul 2014
Windshield, cracked
THE CREW REPORTED THAT ON CLIMB OUT, THE FIRST OFFICER`S WINDSHIELD CRACKED. THE ACFT WAS RETURNED TO FIELD & LANDED WITHOUT FURTHER INCIDENT. THE RT…
- 11 Apr 2014
O-Ring, leaking
CREW REPORTED THAT THEY RECEIVED A BLEED 1 LEAK MSG AFTER TAKEOFF. THE CREW RETURNED TO FIELD & LANDED WITHOUT INCIDENT. REPLACED THE O RING AT JOINT 3.…
- 2 Aug 2013
Light, inoperative
DURING INSPECTION, THE LT AFT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MX REPLACED THE LT HOUSING ASSY AND OPS CHECKED GOOD.
- 26 Jul 2013
Wire Harness, faulty
AFTER TAKEOFF, WHEN LANDING GEAR WAS SELECTED UP, RECEIVED A LANDING GEAR AIR-GROUND FAIL MESSAGE AND LANDING GEAR DID NOT RETRACT. FOLLOWED THE QUICK REF…
- 26 Jul 2013
Proximity Switch, faulty
AFTER TAKEOFF, WHEN LANDING GEAR WAS SELECTED UP, RECEIVED A LANDING GEAR AIR-GROUND FAIL MESSAGE AND THAT THE LANDING GEAR DID NOT RETRACT. FOLLOWED THE…
- 14 Jul 2013
Valve, leaking
CREW REPORTED THAT THEY RECEIVED A BLEED 2 LEAK MESSAGE DURING CLIMB. THE CREW UTILIZED THE QUICK REF HANDBOOK AND THE ISSUE DID NOT RESOLVE. THE CREW…
- 21 Jun 2013
Wire, damaged
DURING INSPECTION, MAIN ENTRY DOOR HAND RAIL EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MX FOUND A DAMAGED WIRE IN THE MAIN ENTRY DOOR WIRING HARNESS AND…
- 5 Mar 2013
Floor Support, cracked
DURING INSPECTION, A CRACK WAS FOUND IN THE RIGHT OMEGA BEAM OUTBOARD SUPPORT BETWEEN FRAMES 47 AND 48. THE OMEGA BEAM SUPPORT WAS REPLACED IN ACCORDANCE WITH…
- 5 Mar 2013
Floor Support, cracked
DURING INSPECTION, A CRACK WAS FOUND ON THE LEFT OMEGA BEAM OUTBOARD SUPPORT BETWEEN FRAMES 47 AND 48. THE OMEGA BEAM SUPPORT WAS REPLACED IN ACCORDANCE WITH…
- 5 Mar 2013
Fitting, cracked
DURING INSPECTION, A CRACK WAS FOUND IN THE SHEAR CLIP AT FRAME 68 BETWEEN STRINGERS 6L AND 7L. THE SHEAR CLIP WAS REPLACED IN ACCORDANCE WITH SRM 53-31-04.
- 11 Mar 2012
O-Ring, leaking
CREW REPORTED, RECEIVED A BLEED 1 LEAK MESSAGE WHILE CLIMBING THROUGH 21,000 FEET, WHILE IN ICING CONDITIONS. THE CREW DIVERTED AND THE AIRCRAFT LANDED…
- 13 Oct 2011
Sense Line, cracked
CREW REPORTED THAT DURING FLIGHT RECEIVED A ENGINE 2 ANTI-ICE FAIL MESSAGE ON THE EICAS. THE ENGINE 2 ANTI-ICE VALVE WAS PREVIOUSLY LOCKED OPEN AND DEFERRED.…
- 20 Apr 2011
Duct, leaking
DURING FLIGHT, THE CREW REPORTED A BLEED 2 LEAK MESSAGE ON EICAS. THE AIRCRAFT DIVERTED TO ROC WHERE THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE…
- 8 Jan 2011
Static Port, faulty
CREW REPORTED A PITOT 2 HEAT INOP MESSAGE IN ICING CONDITIONS AND RETURNED TO FIELD. UPON EXTENSION OF THE LANDING GEAR WITH FLAPS AT 45, THE PITOT 2 HEAT…
- 5 Dec 2009
Wire, shorted
AT APPROXIMATELY FL100 THE CAPTAIN TURNED ON THE LEFT SIDE CHART HOLDER LIGHT AND IT BEGAN TO SMOKE. THE CHART HOLDER LIGHT WAS TURNED OFF AND NO FURTHER…
- 28 Sep 2009
Computer, malfunctioned
FLIGHT 6025, CVG TO SBN. ON TAKEOFF THE CREW NOTICED A ELECTRICAL BURNING SMELL, UNSURE IF IT WAS JUST IN THE COCKPIT OR IN CABIN ALSO. THE CREW RETURNED TO…
- 6 Sep 2009
Actuator, faulty
FLIGHT 6094, CMH TO BOS. WHILE CLIMBING THROUGH 2,500FT THE CREW RECEIVED A MASTER WARNING PT MAIN FAIL. AN AUTO TRIM FAIL MESSAGE ALSO APPEARED BUT…
- 22 Feb 2008
Thermostat, faulted
CMH TO BOS - ON INITIAL CLIMB, THE CREW RECEIVED A MASTER WARNING AND EICAS MESSAGE FOR BLEED 2 OVERTEMP. AFTER RUNNING THE QRH, IT WAS DECIDED TO RETURN TO…
- 1 Feb 2008
Valve, malfunctioned
CVG TO GSP - AFTER TAKEOFF, THE FLIGHT CREW RECEIVED A BLEED 2 OVER-TEMP MASTER WARNING. THE FLIGHT RETURNED TO FIELD AT CVG AND LANDED WITHOUT INCIDENT.…
- 12 Apr 2006
Bulb, burned out
EMERGENCY LIGHT ON MAIN DOOR STAIR HANDRAIL FELL OUT. REMOVED AND REPLACED LAMP IAW EMB 145 MM 33-50-10. OPS CHECK GOOD.
- 21 Sep 2005
Smoke Detector, false indication
FLIGHT 6378 - CMH-RSW - LAVATORY SMOKE WARNING PRESENTED ON EICAS (AND ASSOCIATED MASTER WARNING) AT 400 FEET AGL ON TAKEOFF. FLIGHT ATTENDANT REPORTED SMOKE…
- 26 Jun 2005
Smoke, detected
ON INITIAL CLIMB AT APPROX 500 AGL, RECEIVED LAV SMOKE WARNING EICAS. SMOKE ODOR IN COCKPIT, SMOKE NOT VISIBLE. SMOKE MASKS DONNED AND EMERGENCY RETURN TO…