N573SC
2016 Czech Sport Aircraft A S SPORTCRUISER light sport FAA →
registration
- 2016
earlier registrations
1 past record
service difficulty reports
63 reports
- 20 Jul 1997
Smoke Detector, dirty
THE NUMBER 8 LAVATORY SMOKE DETECTOR CHIRPS AND WILL NOT RESET. CLEANED DUST FROM SMOKE DETECTOR AND UNIT OPS CHECKED GOOD.
- 13 Jul 1997
Wire, broken
A TEN FOOT LENGTH OF PATH LIGHTING, BETWEEN DOORS L-2 AND L-3, WAS FOUND TO BE INOPERATIVE. FOUND BROKEN WIRING IN TWO PLACES. REPAIRED WIRING, PATH LIGHTING…
- 4 Apr 1997
Bulb, failed
NR 2 SMOKE DETECTOR LIGHT DID NOT TEST. RELAMPED SMOKE DETECTOR AND FUNCTIONALLY TESTED GOOD.
- 16 Mar 1997
Light, inoperative
FOUND RIGHT AFT SECTION OF AFT CABIN FLOOR EMERGENCY TRACK LIGHTS FLASHING ON AND OFF. REMOVED AND REPLACED ALL FLOOR TRACK LIGHTING ASSOCIATED WITH THE…
- 2 Mar 1997
Test Switch, inoperative
R1 DOOR SLIDE BOTTLE CHARGE TEST LIGHT WAS FOUND INOP. REPLACED TEST SWITCH IN ACCORDANCE WITH 25-61-03 AND REPAIRED BROKEN WIRE, OPS CHECKED GOOD.
- 1 Mar 1997
Battery Pack, discharged
LEFT MID CABIN FLOOR EMERGENCY TRACK LIGHTING, INOP. REMOVED AND REPLACED LEFT HAND MID CABIN FLOOR TRACK LIGHTING. BATTERY PACK AND OPS CHECKED GOOD.
- 21 Feb 1997
Lamp, failed
FOUND RANDOM EMERGENCY FLOOR TRACK LIGHTS BURNED OUT UNDER THE FLOOR EXIT PLACARDS NEAR R1, R2, R4, L2 AND L4 DOORS. REMOVED AND REPLACED LAMPS.
- 16 Feb 1997
Wire, broken
FOUND EMERGENCY FLOOR TRACK LIGHTING INOP IN FORWARD CABIN, FIRST ZONE ON LEFT SIDE. REPAIRED BROKEN WIRE AT L1 DOOR AND SYSTEM OPS CHECKED GOOD.
- 22 Jan 1997
Battery Pack, discharged
FOUND LEFT SIDE EMERGENCY FLOOR TRACK LIGHTING INOP AT MID CABIN. REPLACED POWER SUPPLY IN ACCORDANCE WITH MM 33-51-01 AND OPS CHECKED NORMAL.
- 22 Dec 1996
Battery Pack, discharged
FOUND EMERGENCY FLOOR TRACK LIGHT IN MID CABIN RIGHT SIDE INOP. REMOVED AND REPLACED BATTERY PACK AND OPS CHECKED GOOD.
- 8 Dec 1996
Prox Elec Unit, failed
ALL THREE GEAR UNSAFE LIGHTS ILLUMINATED AFTER GEAR RETRACTION. REPOSITIONSED WIRE BUNDLE INTERFERING WITH HANDLE INTERLOCK SWITCH, REMOVED AND REPLACED…
- 6 Dec 1996
Pump, failed
INFLIGHT, SMOKE WAS REPORTED IN AFT LAV, DISCHARGED TWO FIRE EXTINGUISHERS. DIVERTED TO MSP AND DUMPED FUEL. REMOVED AND REPLACED AFT LAV PUMP AND OPS CHECKED…
- 1 Nov 1996
Power Supply, inoperative
FOUND RIGHT FORWARD EMERGENCY FLOOR LIGHTS INOP. REMOVED AND REPLACED BATTERY PACK POWER SUPPLY AND OPS CHECKED GOOD.
- 1 Nov 1996
Lamp, inop
NO INDICATION OF GREEN ON LEFT MAIN GEAR. VISUALLY CONFIRMED GEAR WAS DOWN AND LOCKED, AND PULLED EMERGENCY EXTENSION. FOUND BULB BURNT OUT. REMOVED AND…
- 27 Oct 1996
Smoke Detector, inoperative
NUMBER 1 CARGO SMOKE DETECTOR DOES NOT TEST. REPLACED BEACON LAMP IN SMOKE DETECTOR AND OPS CHECKED GOOD.
- 17 Sep 1996
Power Supply, inoperative
OVERWING EMERGENCY LIGHT FAILED TEST. REMOVED AND REPLACED OVERWING EMERGENCY POWER SUPPLY IN ACCORDANCE WITH MM 33-51-01 AND OPS CHECKED GOOD.
- 12 Sep 1996
Track, inoperative
EMERGENCY FLOOR TRACK LIGHTING IN FORWARD CABIN, RIGHT SIDE FROM SEAT 5 TO SEAT 11, LIGHT INOP. FOUND DAMAGED RIBBON WIRE. REPAIRED WIRES, OPS CHECKED…
- 6 Sep 1996
Smoke Detector, inoperative
THE SECOND LIGHT ON THE SMOKE DETECTOR PANEL WOULD NOT TEST. PLACED SMOKE DETECTOR ON MEL 26-15A.
- 15 Aug 1996
Lower Rail, corroded
DURING INSPECTION, FOUND CENTER CARGO PIT CUT OUT LOWER RAIL UPPER SURFACE CORRODED AT BS 1709.5. BLENDED OUT CORROSION PER SABRE TECH EA DC10-53-004.
- 15 Aug 1996
Door Frame, corroded
DURING INSPECTION, FOUND FORWARD CARGO DOOR CUTOUT FRAME AT BS 885.8, FORWARD VERTICAL LEG HAS CORROSION AT APPROXIMATELY LONGERON 42R. REPAIRED ANGLE IN…
- 13 Aug 1996
Tee Fitting, corroded
DURING INSPECTION, FOUND CENTER CARGO PIT FORWARD LOWER CORNER TEE FITTING CORRODED. REPLACED TEE IN ACCORDANCE WITH SABRE TECH EA DC10-53-004.
- 13 Aug 1996
Frame, corroded
DURING INSPECTION, FOUND CENTER CARGO COMPARTMENT LOWER FORWARD FRAME CORRODED. BLENDED OUT CORROSION IN ACCORDANCE WITH SABRE TECH EA DC10-53-004.
- 13 Aug 1996
Fitting, corroded
DURING INSPECTION, FOUND FORWARD CARGO COMPARTMENT LOWER FORWARD CORNER FITTING CORRODED. REMOVED AND REPLACED FITTING IN ACCORDANCE WITH SABRE TECH EA…
- 13 Aug 1996
Tee Fitting, corroded
DURING INSPECTION, FOUND FORWARD CARGO COMPARTMENT LOWER AFT CORNER TEE FITTING CORRODED. REMOVED AND REPLACED TEE FITTING IN ACCORDANCE WITH SABRE TECH EA…
- 13 Aug 1996
Door Jamb, corroded
DURING INSPECTION, FOUND CORROSION ON FORWARD CORNER OF LOWER JAMB IN FORWARD CARGO PIT. BLENDED CORROSION IN ACCORDANCE WITH SABRE TECH EA DC10-53-003.
- 30 Jul 1996
Lamp, inoperative
CARGO SMOKE DETECTOR FAILED TEST ON THE NUMBER 3 POSITION. RELAMPED NUMBER 3 SMOKE DETECTOR AND OPERATIONAL CHECKED NORMAL.
- 18 May 1996
Bulb, failed
ONE EMERGENCY LIGHT BY THE FORWARD LEFT HAND LAV WAS FOUND INOP. PLACED ON MEL. REMOVED AND REPLACED LIGHT BULB IN FLOOR TRACK LIGHT.
- 17 May 1996
Oven, smoking
WHILE OFF, SMOKE STARTED TO COME OUT OF LATCHING MECHANISM ON OVEN NR 3. CIRCUIT BREAKERS WERE PULLED AND GALLEY POWER WAS TURNED OFF. RESET CIRCUIT BREAKER…
- 6 Apr 1996
Detector, faulty
THE RIGHT FORWARD LAVATORY CAUSED A CONTINUOUS AURAL WARNING IN THE GALLEY. REMOVED AND REPLACED SMOKE DETECTOR, OPS CHECKED GOOD.
- 3 Mar 1996
Smoke Detector, failed
THE SMOKE DETECTOR IN LAVATORY NUMBER 8 WAS FOUND TO SOUND INTERMITTENTLY. CLEANED OPTICAL LENS AND DETECTOR, OPS CHECKED GOOD.
- 21 Feb 1996
Track, inoperative
THE AFT CABIN, LEFT SIDE, REAR HALF OF EMERGENCY PATH LIGHTING WAS FOUND TO BE INOPERATIVE. REPLACED DAMAGED SECTION OF FLOOR TRACK LIGHTING AND FLOOR TRACK…
- 9 Feb 1996
Smoke Detector, failed
THE NUMBER 3 LAVATORY SMOKE DETECTOR SOUNDED CONTINUOUSLY FOR NO APPARENT REASON. REMOVED AND REPLACED NUMBER 3 LAVATORY SMOKE DETECTOR AND DETECTOR TESTED…
- 2 Feb 1996
Track, failed
EMERGENCY TRACK LIGHTING FROM SEATS 11ABC TO 13ABC WAS FOUND TO BE INOPERATIVE. FOUND BROKEN WIRE. REPAIRED WIRE AND LIGHTS OPS CHECKED NORMAL.
- 30 Jan 1996
Interlock Crank, frozen
DURING CLIMB HAD TO USE THE OVERRIDE GEAR RELEASE TO RAISE LANDING GEAR. THE MAIN GEAR HYDRAULIC INTERLOCK CYLINDER CRANK WAS FOUND FROZEN WITH ICE IN THE…
- 16 Dec 1995
Slide Press Ind, malfunctioned
THE L-2 DOOR SLIDE WOULD NOT TEST. REMOVED AND REPLACED SLIDE PACK PRESSURE INDICATOR IAW MM 25-61-03 AND SLIDE TESTED GOOD.
- 21 Nov 1995
Slide, failed
WHEN OPENING THE R-3 DOOR THE SLIDE WAS DEPLOYED INADVERTENTLY AND THE UPPER PORTION OF THE SLIDE FAILED TO INFLATE. REMOVED AND REPLACED THE R-3 DOOR SLIDE.
- 14 Nov 1995
Batteries, discharged
THE L-3 DOOR SLIDE WOULD NOT TEST. REMOVED AND REPLACED BATTERIES FOR L-3 DOOR SLIDE LIGHT AND SLIDE TESTED GOOD.
- 9 Nov 1995
Smoke Detector, dirty
THE SMOKE DETECTOR IN THE NUMBER 3 LAV SOUNDED DURING LANDING, NO APPARENT REASON. CLEANED SMOKE DETECTOR AND UNIT PASSED SELF TEST.
- 8 Nov 1995
Smoke Detector, failed
THE NUMBER 8 LAVATORY SMOKE DETECTOR WAS FOUND TO SOUND FOR NO APPARENT REASON. REMOVED AND REPLACED NUMBER 8 LAV SMOKE DETECTOR, NEW DETECTOR OPS CHECKED GOOD.
- 5 Oct 1995
Frame, corroded
DURING SCHEDULED INSPECTION, CORROSION WAS FOUND ON THE AFT FACE OF STATION 1505 FRAME LOWER CAP AT APPROXIMATELY BS 78. THE FRAME WAS REPAIRED IAW SUN…
- 5 Oct 1995
Blkhd Stiffener, corroded
DURING SCHEDULED INSPECTION, CORROSION WAS FOUND ON THE VERTICAL STIFFENER ATTACHED TO THE FORWARD SIDE OF THE STATION 1521 BULKHEAD AT APPROXIMATELY BS 78.…
- 5 Oct 1995
Intercostal, corroded
DURING SCHEDULED INSPECTION, CORROSION WAS FOUND ON THE INTERCOSTAL AT STATION 1505, APPROXIMATELY BS 78. REMOVED AND REPLACED THE INTERCOSTAL AT STATION 1505…
- 20 Sep 1995
Slide Indicator, failed
THE R-3 DOOR SLIDE WOULD NOT TEST. REPLACED THE R-3 DOOR TEST INDICATOR AND SLIDE TESTED GOOD PER MM 25-61-03.
- 20 Sep 1995
Slide, faulty
THE L-3 DOOR SLIDE WOULD NOT TEST. REPLACED THE L-3 DOOR SLIDE IAW MM 25-61-01 AND THE SLIDE TESTED GOOD.
- 2 Sep 1995
Smoke Detector, failed
SMOKE DETECTOR IN MID GALLEY CEILING WAS INTERMITTENTLY SOUNDING. REPLACED SMOKE DETECTOR WHICH WAS CAUSING ALARM SOUND, NEW DETECTOR OPS CHECKED GOOD PER MM…
- 12 Aug 1995
Smoke Detector, malfunctioned
THE SMOKE DETECTOR IN LAVATORY NUMBER 8 WENT OFF TWICE FOR NO APPARENT REASON. REMOVED AND REPLACED NUMBER 8 LAV SMOKE DETECTOR AND UNIT TESTED GOOD.
- 30 Jul 1995
Eel Battery Pack, discharged
THE FORWARD LEFT AND RIGHT EMERGENCY FLOOR LIGHTS ILLUMINATED SHORTLY AFTER TAKEOFF. THE EMERGENCY LIGHTS WERE FOUND SHORTED DUE TO A RIGHT FORWARD LAV…
- 21 Jul 1995
Eel Connector, shorted
FOUND THE OVERWING (OVERHEAD) EMERGENCY LIGHTS INTERMITTENT. CONNECTOR PI-2069 WAS FOUND INTERNALLY SHORTING WHEN CONNECTED TO THE EMERGENCY LIGHT BATTERY…
- 19 Jul 1995
Eel Power Supply, failed
DURING LINE CHECK FOUND THE MID CABIN OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED MID CABIN POWER SUPPLY IAW MM 33-50-00. LIGHTS CHECKED GOOD.
- 15 Jul 1995
Eel Power Supply, failed
DURING LINE CHECK, FOUND MID CABIN FLOOR EMERGENCY LIGHTS DIM. REMOVED AND REPLACED MID CABIN POWER SUPPLY IAW MM 33-50-00. LIGHT OPS CHECKED GOOD.
- 14 Jul 1995
Smoke Detector, failed
FOUND NUMBER 3 LAVATORY SMOKE DETECTOR GOING OFF FOR NO APPARENT REASON. REMOVED AND REPLACED NUMBER 3 LAVATORY SMOKE DETECTOR PER MM 26-00. SMOKE DETECTOR…
- 2 Jul 1995
Smoke Detector, malfunctioned
SMOKE DETECTOR IN THE NR FOUR LAVATORY WENT OFF FOR NO APPARENT REASON DURING FLIGHT. BLEW DUST OUT OF SMOKE DETECTOR AND UNIT TESTED GOOD.
- 1 Jul 1995
Smoke Detector, failed
SMOKE DETECTOR ON FORWARD GALLEY BEEPS ONCE EVERY 10 MINUTES. TIGHTENED CANNON PLUG ON SMOKE DETECTOR AND DETECTOR CHECKED GOOD.
- 13 Jun 1995
Indicator, failed
FOUND THE R2 DOOR SLIDE INTEGRITY TEST INOPERATIVE. REMOVED AND REPLACED THE R2 DOOR SLIDE LIGHT INDICATOR, LIGHT TESTED GOOD.
- 30 May 1995
Test Lamp, faulty
FOUND R-2 SLIDE BOTTLE INTEGRITY TEST INOPERATIVE. RELAMPED R-2 DOOR TEST MODULE AND SLIDE TESTED GOOD.
- 3 Mar 1995
Eel Track, failed
EMERGENCY FLOOR TRACK LIGHTING IN FORWARD CABIN, LEFT SIDE INOPERATIVE. REPAIRED WIRE AT L1 PORTION OF FLOOR TRACK LIGHTING AND OPS CHECK GOOD.
- 20 Feb 1995
Eel Track, failed
MSP - EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE IN FWD CABIN, LT AND RT SIDES. ON LT SIDE OF FWD CABIN, REPAIRED BROKEN WIRE, REPLACED FLOOR TRACK COVER AND…
- 10 Feb 1995
Smoke Detector, faulty
MSP - THE NR 1 LAV SMOKE DETECTOR RINGING IN OVERHEAD PANEL. REMOVED AND REPLACED SMOKE DETECTOR, OPERATION CHECK GOOD. (W)
- 9 Feb 1995
Smoke Detector, dirty
MSP - THE FWD NR 1 LAV SMOKE DETECTOR GOES OFF FOR NO APPARENT REASON. CLEANED SMOKE DETECTOR AND RESEATED CANNON PLUG. SMOKE DETECTOR CHECKED GOOD. (W)
- 8 Feb 1995
Sump Line, leaks
MSP - FLT 67 - THE NR 2 ENGINE OIL PRESSURE DROPPED BELOW THE RED LINE, OIL QUANTITY DROPPED TO 3 QUARTS, PRECAUTIONARY SHUTDOWN OF NR 2 ACCORDING TO…
- 20 Jan 1995
Smoke Det, dirty
MSP - THE FWD GALLEY SMOKE DETECTOR BEEPS INTERMITTENTLY. UNABLE TO DUPLICATE PROBLEM, BLEW DUST OUT OF ALL LAV SMOKE DETECTORS PRECAUTIONARY AND OPERATIONAL…
- 9 Dec 1994
Eel, inoperative
GSO - THE FWD LT C-SECTION EMERGENCY PATH LIGHTING INOPERATIVE AND DAMAGED. REMOVED AND REPLACED FWD LT C-SECTION OF EMERGENCY PATH LIGHTING IAW DC 10 MM…
- 30 Nov 1994
Spar Caps, corroded
GSO - THE LT AND RT HORIZONTAL STABILIZER FWD LOWER SPAR CAPS HAS TRAPPED FLUID AND EXFOLIATION CORROSION. AREA LOCATED JUST O/B OF CONSTANT BOX CAN BE SEEN…