N571JB
2003 Airbus A320-232 standard FAA →
registration
- 2003
service difficulty reports
88 reports
- 15 Aug 2026
Pump, leaking
FLT 585, JFK-RDU (AIRTURN BACK TO JFK) G RSVR KO LVL ON TAKEOFF-ECAM-HYD PAGE SHOWED B SYS RSVR LO LVL.. R & R GREEN SYS EDP (1030EK) IAW AMM 29-11-51 UP TO…
- 24 Oct 2025
Apu, odor
FLT#1233, MCO-SJU. "DURING CLIMB AND CRUISE INFLIGHT CREW REPORTED STRONG ODOR/SMELL OF STINKY CHEESE/DIRTY SOCKS . REPORT FROM FWD GALLEY TO ROW 4. MODERATE…
- 1 Oct 2025
Battery, failed
FLT#591, BOS-TPA. "EMERGENCY EXIT SIGNS AIRCRAFT RIGHT REMAINED ON ENTIRE FLIGHT AND AIRCRAFT RIGHT WAS OFF ENTIRE FLIGHT; ED TSM 33-51-00-810-837A PERFORMED…
- 1 Oct 2025
Battery, failed
FLT#591, BOS-TPA. "DURING CHECK OF EMERGENCY BATTERY CABIN IAW AMP TASK 335100-03-1 FWD L BATT FAULT FOUND; REMOVED AND REPLACED L FWD BATT 10WL IAW AMM…
- 25 Feb 2025
Cooling Fan, leaking
FLT#1979, DCA-FLL. 'UPON LANDING INFLIGHT WORKING REAR OF AIRCRAFT COMPLAINED OF ODOR ON DECENT, NO SMELL IN COCKPIT OR FRONT CABIN; FOUND APU COOLING FAN…
- 6 Nov 2024
Frame, cracked
DURING HEAVY MAINTENANCE: FUSELAGE / NOSE FWD FUSELAGE / WINDSHIELD FRAME / CENTER POST LOWER NODE & CONTINUITY FITTING LH/RH AREAS / CRACKS - PERMANENT…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: FUSELAGE / NOSE FWD FUSELAGE / FR 20 RH / DOUBLE JOGGLE AREA / DOOR STOP FITTING 7 HOLE 6 / CRACK - PERMANENT REPAIR (FRAME…
- 6 Nov 2024
Hinge, worn
DURING HEAVY MAINTENANCE: FUSELAGE / CENTER FUSELAGE / FR 35 & STR 30L / PRESSURE BULKHEAD / HOLES #2 & 6 / CRACK DAMAGE – TIME LIMITED REPAIR; REFERENCES:…
- 6 Nov 2024
Hinge, worn
DURING HEAVY MAINTENANCE: CORROSION STRINGER 31R LOCATED BTW FR64 TO FR65 IN AFT CARGO COMPARTMENT (CPCP FINDING); REF AEROMAN WO 2024 275/1 NR 538820 *…
- 6 Nov 2024
service difficulty reports
DURING HEAVY MAINTENANCE: WEAR ON STRINGER 39R LOCATED BTW FR47 TO FR 48 AFT CARGO COMPARTMENT; REF AERMAN W.O. 2024 275/1 NR 538884 * REMOVED AND REPLACED…
- 6 Nov 2024
Hinge, worn
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FASTENER HOLE FR16 RH STOP FITTING 7 UPPER I/B HOLE. CRACK DEPTH IS 0.18; EF AEROMAN W.O. 2024 275/1 NR 538514 *…
- 6 Nov 2024
Stabilizer, worn
DURING HEAVY MAINTENANCE: WEAR ON HINGE 6 UPPER SIDE LOWER AREA ON VERTICAL STABILIZER; (RESOLVED ON W/O: 1318564 TASKCARD: NR-00042) REF AE WO 2024-275/1.…
- 6 Nov 2024
Fastener, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON OPEN FASTENER HOLE LOC. ON FR.20 RH DOOR STOP FITTING 7 UPPER I/B HOLE. CRACK DEPTH IS 0.081 INCH APPROX;…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 16 RH SIDE FROM HOLE D OF JOGGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA. CRACK…
- 6 Nov 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 16 RH SIDE FROM HOLE B OF JOGGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA. CRACK…
- 6 Nov 2024
Stringer, corroded
DURING HEAVY MAINTENANCE: CORROSION STRINGER 42L AND BTW FR58 TO FR59 AFT CARGO COMPARTMENT (CPCP FINDING);(RESOLVED ON W/O: 1318564 TASKCARD: NR-00037) REF…
- 6 Nov 2024
String, corroded
DURING HEAVY MAINTENANCE: CORROSION STRINGER 43L AND BTW FR58 TO FR60 AFT CARGO COMPARTMENT (CPCP FINDING); (RESOLVED ON W/O: 1318564 TASKCARD: NR-00036) REF…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 16 RH SIDE FROM HOLE A OF JOOGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA. CRACK…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON OPEN FASTENER HOLE LOC. ON FR.16 LH DOOR STOP FITTING 7 LOWER I/B HOLE, CRACK DEPTH IS 0.123 INCH APPROX;…
- 6 Nov 2024
Door Frame, no discrepancy
DURING HEAVY MAINTENANCE: (RESOLVED ON W/O: 1318564 TASKCARD: NR-00033) REF AE WO 2024-275/1. N/R# 2024 - 538516. REMOVED AND REPLACED INTERCOSTAL FITTING…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON OPEN FASTENER HOLE LOC. ON FR.16 RH DOOR STOP FITTING 7 LOWER I/B HOLE. CRACK DEPTH IS 0.165 INCH APPROX;…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 16 RH SIDE FROM HOLE 8 OF JOOGLE AREA LOC ATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA.…
- 6 Nov 2024
Door, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 16 LH SIDE FROM HOLE 7 OF JOOGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA. CRACK…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 20 RH SIDE FROM HOLE 3 OF JOOGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA. CRACK…
- 6 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR 20 LH SIDE FROM HOLE 7 OF JOOGLE AREA LOCATED AT LEVEL OF DOOR STOP FITTING 7 AT FWD GALLEY AREA. CRACK…
- 12 Jul 2024
Pressure Switch, failed
FLT#1691, JFK-LIR. (AIRCRAFT DIVERTED TO MCO) 'APU AUTO SHUTDOWN IN CRUISE FLIGHT -ATTEMPTED RESTART IN COORDINATION WITH MCC BUT IT WAS NOT SUCCESSFUL UNIT…
- 11 Jul 2024
Unknown, odor
FLT#131, MCO-LAX. 'ON FINAL APPROACH FLIGHT ATTENDANT NOTED BR/EF DIRTY SOCK TYPE ODOR. THIS WENT AWAY SHORTLY AFTER LANDING ROLL-OUT. NEITHER CAPT NOR F/O…
- 12 May 2024
Unknown, odor
FLT#975, JFK-MSY. ' ODOR IN AFT CABIN ON DESCENT; C/W INFO NOTED, 2017-7015 SEC:A ISOLATED FAULT TO TYPE. 10. REF: 75M 05-50-00, ACFT OK FOR SERVICE.'
- 12 Mar 2024
Unknown, odor
FLT#1079, JFK-MBJ. 'ODOR EVENT BEGAN AT TOP OF DESCENT. LAST 5 ROWS OF A/C EXPERIENCED A CLEANING LIKE SMELL REPORTED TO FLT CREW AT GATE. ( PACKS );…
- 11 Nov 2023
Unknown, unknown
FLT#5, JFK-PTP. 'BEGINING AROUND 12000 FEET ON DEC. BEGAN TO SMELL STRONG DIRTY SOCK SMELL.CONTACTED #1 FA AND ALL CREW MEMBERS EXPERIENCED THE SAME SMELL BUT…
- 29 Sep 2023
Unknown, unknown
FLT#1167, HPN-PBI. 'APPARENT TRICRESYLPHISPATE FUMES ( OIL FUMES ) ON DEP OUT OF HPN. DISSIPATED QUICKLY MUCH STRONGER FUMES ODOR ON IDLE DESCENT PACK 1 OFF…
- 9 Jul 2022
Blade, damaged
FLT#1359, JFK-KIN. (AIRCRAFT PERFORMED AN AIR TURN BACK TO JFK) ' BIRD STRIKE ON TO ROLL ENG 2 VIBE (N1) N 5.1 ON CLIMB OUT AND NOTICED HIGHER ENG 2 VIB ON…
- 2 May 2022
None, none
FLT#2295, EWR-MIA. ' DIRTY SOCK SMELL FROM T/O AND DURING DECENT. GOT A CALL FROM FA( AFT) AT 15000 CLEAR SKIES DURING DESCENT. RAINING DURING TAKE OFF APU…
- 23 Apr 2021
Flap System, warning message
FLT 2894, MIA-EWR. F/CTL FLAPS LOCKED - WING TIP BRK ON ECAM CAME ON WHEN CONFIGURING TO LAND. IN SELECTING FLAPS 2 THE FLAP HANDLE OVERSHOT 1/1 WAY TO FLAPS…
- 20 Mar 2021
Unknown, odor
FLT 2459, BDL-FLL. DURING FINAL TO ILS 28L, F/O SMELLED DIRTY SOCK SMELL. AFTER LANDING FLT ATT'S REPORTED NOTHING SIGNIFICANT UNTIL REACHING GATE. (NO…
- 15 Oct 2020
Proximity Sensor, out of adjust
FLIGHT NR 104, SDQ-EWR. L1 DOOR SLIDE INDICATION INOPERABLE. REMOVED AND REINSTALLED SLIDE PAC AT L1 DOOR TO VERIFY PROPER INSTALLATION, REF AMM 25-62-44.…
- 19 Jul 2020
Valve, failed
FLT 2137, AFTER TAKEOFF, ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH THE HP VALVE & PRESSURE REGULATING VALVE. PERFORMED…
- 19 Jul 2020
Valve, failed
FLT 2137, AFTER TAKEOFF, ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH THE HP VALVE, & PRESSURE REGULATING VALVE. PERFORMED…
- 19 Jul 2020
Valve, failed
FLT 2137, AFTER TAKEOFF ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH HP VALVE & PRESSURE REGULATING VALVE. PERFORMED A BLEED…
- 20 Jul 2019
Fan, failed
FLT 61, BOS-SJU. EXCESSIVE NOISE FROM BLOWER FAN FOLLOWED BY A WIFF OF SMOKE. SELECTED FAN TO OVRD . ( BLOWER FAN - NO AVNCS SYS FAULT ECAM CAUTION );…
- 26 Sep 2018
Support Frame, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42714: AFT CABIN WET AREA FR69-70 RH SHEAR WEB SUPPORT FR CORR; REF NR 42714 FOR ALL…
- 26 Sep 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42698: FR20 FLR BEAM Y1292 CORR; REF NR 42698 FOR ALL WORK ACP: CORR BEYOND LIM RPL…
- 26 Sep 2018
Fitting, cracked
DURING HEAVY MAINTENANCE, REF: HAECO NR# 42711 R/H CORNER FITTING AT FR36, ATTACH HOLE CRACKED; REMOVED & REPLACED RH CORNER FITTING AT FR36 IAW A320 SRM…
- 26 Sep 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BULK CARGO DOOR SILL FR60 STR 38R; (REF HAECO NR 440504-42571)REMOVED AND REPLACED BULK CARGO DOOR SILL…
- 26 Sep 2018
Stringer, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CARGO COMP STR BILGE AREA 58-59 STR 43LH; (REF HAECO NR 440504-42556) REMOVED AND REPLACED CORRODED…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42530: RH AFT CABIN FLR BEAM –Y765 CORR FWD OF FR68; REF NR 42530 FOR ALL WORK ACP:…
- 26 Sep 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF NR 42530 FOR ALL WORK ACP: CORR BEYOND LIM RPL BEAM PER SRM 51-72-11; REF NR 42529 FOR ALL WORK ACP:…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42523: LH AFT CABIN FLR BEAM Y919 CORR 12” FWD FR67; REF NR 42523 FOR ALL WORK ACP:…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42526: LH AFT CABIN FLR BEAM Y919 CORR FR66; REF NR 42526 FOR ALL WORK ACP: CORR…
- 26 Sep 2018
Support Frame, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42516: AFT CABIN WET AREA FR69-70 LH SHEAR WEB SUPPORT FR CORR; REF NR 42516 FOR ALL…
- 26 Sep 2018
Shear Web, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42520: AFT CABIN WET AREA FR69-70 RH SHEAR WEB CORR; REF NR 42520 FOR ALL WORK ACP:…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42539: LH AFT CABIN FLR BEAM Y1732 CORR 2IN FWD OF FR66; REF NR 42539 FOR ALL WORK…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42538: RH AFT CABIN FLR BEAM -Y1732 CORR 4IN FWD OF FR68 DR SILL; REF NR 42538 FOR ALL…
- 26 Sep 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42537: RH AFT CABIN FR66 DR SILL -Y1732 CORR; REF NR 42537 FOR ALL WORK ACP: CORR…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42517: LH AFT CABIN FLR BEAM Y1292 SPOT OF CORR 10IN FWD FR69; REF NR 42517 FOR ALL…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42532: RH AFT CABIN FLR BEAM -Y1292 CORR 5IN FWD FR68; REF NR 42532 FOR ALL WORK ACP:…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42534: RH AFT CABIN FLR BEAM -Y1292 CORR 11IN FWD FR67; REF NR 42534 FOR ALL WORK ACP:…
- 26 Sep 2018
Web, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42568: AFT CARGO COMP WEB SILL UPR SKIN FR53-FR55 CORR; REF HAECO NR 440504-42568: AFT…
- 26 Sep 2018
Beam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42589: CABIN DUMMY BEAM AT Y512 FR16L CORR; REF NR 42589 FOR ALL WORK ACP: CORR BEYOND…
- 26 Sep 2018
Attach Angle, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42595: CABIN FLR BEAM ATTACH ANGLE CORR RH FR20; REF NR 42595 FOR ALL WORK ACP: CORR…
- 26 Sep 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42590: CABIN SEAT TRACK Y765 FR16 CORR; REF NR 42590 FOR ALL WORK ACP: RPL FLR SEAT…
- 26 Sep 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42515: L2 DR SILL CUTOUT CORR ON FR68 STR23 LH; REF NR 42515 FOR ALL WORK ACP: RPL L2…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42517: FR68 FLR BEAM Y1292 CORR; REF NR 42517 FOR ALL WORK ACP: CORR BEYOND LIM RPL…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42699: FR16 FLR BEAM -Y1292 CORR; REF NR 42699 FOR ALL WORK ACP: CORR BEYOND LIM RPL…
- 26 Sep 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON REF HAECO NR 440504-42527: LH AFT CABIN FLR BEAM Y765 CORR FR68; REF NR FOR ALL WORK ACP: CORR BEYOND…
- 26 Sep 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42528: LH AFT CABIN FLR BEAM Y765 CORR 10" FWD FR68; REF NR 42528 FOR ALL WORK ACP:…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42535: RH AFT CABIN FLR BEAM -Y1292 CORR; REF NR 42535FOR ALL WORK ACP: CORR BEYOND…
- 26 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42524: LH AFT CABIN FLR BEAM Y1292 CORR FR66; REF NR 42524 FOR ALL WORK ACP: CORR…
- 26 Sep 2018
Web, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42465: FWD CARGO COMP WEB SILL FR26-FR28 CORR; REF NR 42465 FOR ALL WORK ACP: CORR…
- 26 Sep 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED, REF HAECO NR 440504-42536: RH AFT CABIN FLR BEAM –Y765 CORR FR66; REF NR 42536 FOR ALL WORK ACP: CORR…
- 10 Jan 2018
Unknown, odor
FT # 401, BOS-MSY. DURING CLIMBOUT, THE REAR OF THE AIRCRAFT EXPERIENCED TOXIC FUMES ODOR DURING THE DESCENT IT AS SMELLED IN THE AFT GALLEY; COMPLIED WITH…
- 8 Dec 2017
Unknown, odor
FT # 132, LAX-MCO. VERY STRONG SMELL OF DIRTY SOCKS W/ CHEMICAL SMELL AT 6500 ALT, THRUST IDLE; COMPLIED WITH INFORMATION NOTICE 2017-T015B SECTION C TABLE 1.…
- 7 Dec 2017
Apu, failed
FT # 85, BUF-MCO. AT THE GATE WITH APU ON TOXIC FUMES TCP ODOR PRIOR FLT MENTIONED FUMES AT 9000 FEET ON DESCENT. ( APU SYSTEM ); PERFORMED PER INFRO NOTICE…
- 15 Nov 2017
Battery Pack, failed
DURING POWER OFF EMERGENCY LIGHT SIGN MIDDLE AND REAR FAILED TO LIGHT. FOUND THE BATTERIES 11WL & 12WL DEAD. R & R THE BATTERIES IAW AMM 33-51-38. OPS NORMAL.
- 15 Nov 2017
Battery Pack, inoperative
DURING POWER OFF, EMERGENCY LIGHT SIGN, MIDDLE AND REAR FAILED TO ILLUMINATE. FOUND THE BATTERIES 11WL &12WL DEAD. R & R THE BATTERIES THE AMM 33-51-38. OPS…
- 13 Nov 2016
Display, malfunctioned
FLIGHT CREW REPORTED THAT AFTER DEPARTURE, THE NAVIGATIONAL DISPLAYS WERE NOT AVAILABLE ON THE MULTIFUNCTIONAL PANEL. ALL THREE IRS POSITIONS WERE NOT IN…
- 2 Apr 2015
Power Supply, failed
FLT 6454 , ON MAINTENANCE CHECK FOUND EMERGENCY LIGHT TEST FAULT EPSU BATTERY EMERGENCY AFT L. R & R EPSU 13WL IAW AMM 33-51-38-000-001-A, PARA 4 A,…
- 2 Apr 2015
Power Supply, failed
ON MAINTENANCE CHECK FOUND EMERGENCY LIGHT HAD TEST FAULT EPSU BATTERY EMERGENCY. R & R EPSU 12WL IAW AMM 33-51-38-000-001-A PARA 4.A, 33-51-38-400-001-A PARA…
- 14 Feb 2014
Light, intermittent
PILOT REPORTED LEFT EMERGENCY EXIT, OVERWING LIGHTS INOPERATIVE. ACCOMPLISHED OPS CHECK WITH NO DEFECTS NOTED. OK FOR CONTINUED SERVICE.
- 26 Sep 2013
Sill, corroded
ON HEAVY MX, FOUND CORROSION AT AFT PAX CABIN LOWER L2 SILL BEAM LOCATED AT FRAMES 66 & 68 AT STRINGER 23L. REMOVED CORROSION IAW SRM 51-74-00. REMOVED…
- 26 Aug 2013
Windshield, cracked
CREW RECEIVED AN ANTI-ICE LT WINDSHIELD CAUTION MESSAGE CLIMBING THROUGH 10000 FT L WINDSHIELD HEAT INOPERATIVE. UPPER RT CORNER OF LT WINDSHIELD CRACKED SAW…
- 18 Jan 2012
Wire Harness, defective
FLT 369 LGA-PBI, EMERGENCY ROW 9D LIGHT FLOOR PROXIMITY INOP. REMOVED AND REPLACED EMERGENCY LIGHT HARNESS AT 9D IAW AMM 33-51-21. OPS CHECK OK.
- 21 Nov 2009
Actuator, failed
FLT JB350 - DECLARED AN EMERGENCY FOR FLIGHT CONTROL FLAPS FAILURE FAULT. LANDED WITHOUT INCIDENT. MX TROUBLESHOT PER TSM 27-51-00-810-810 OPERATIONAL TEST OF…
- 4 Sep 2005
Battery Pack, failed
RIGHT SIDE OVERWING EMERGENCY EXIT LIGHT IS INOPERATIVE. REPLACED BATTERY PACK ON RT EPSU IAW MM 33-51-00, OPS CHECK OK.
- 24 Aug 2005
Battery, failed
RIGHT OVERWING EMERGENCY EXIT DOOR LIGHT INOP. REPLACED RIGHT EMERGENCY BATTERY PACK IAW 33-51-38.
- 20 Aug 2005
Battery, discharged
EMERGENCY EXIT LIGHT FOR OVERWING EXITS RT INOP. REPLACED EMERGENCY LIGHT BATTERY OVERWING RT SIDE.
- 28 Feb 2004
Electrical Box, shorted
ELECTRICAL BURNING ODOR OBSERVED IN LAST 5 ROWS OF CABIN, LIVE TV TURNED OFF. PERFORMED INFORMATION NOTICE 2003-T050TRA LIVE TV SYSTEM INTEGRITY CHECK…
- 18 Feb 2004
Electrical Box, shorted
ELECTRICAL BURNING SMELL OBSERVED IN LAST 5 ROWS OF CABIN, LIVE TV TURNED OFF. PERFORMED INFORMATION NOTICE 2003-T050TRA LIVE TV SYSTEM INTEGRITY CHECK…