N570JB
2003 Airbus A320-232 standard FAA →
registration
- 2003
service difficulty reports
50 reports
- 3 Nov 2024
Skin, damaged
DURING HEAVY MAINTENANCE: FUSELAGE / CENTER FUSELAGE / FR35 FWD FACE TO PRESSURE BULKHEAD ATTACHMENT / STR 30LH / FASTENER HOLES / CRACKS - PERMANENT REPAIR;…
- 3 Nov 2024
Window Frame, cracked
DURING HEAVY MAINTENANCE: FUSELAGE / NOSE FWD FUSELAGE / WINDSHIELD FRAME / CENTER POST LOWER NODE / AREA LH/RH CRACKS - PERMANENT REPAIR; REFERENCES: /1/…
- 3 Nov 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FR68 RH AT LOWER INB FASTENER HOLE OF DOOR S TOP FITTING Ñ1 AREA. CRACK DIRECTION 5 OCLOCK VIEW LOOKING…
- 3 Nov 2024
Crossbeam, cracked
DURING HEAVY MAINTENANCE: DISCREPANCY DESCRIPTION: CRACK INDICATION FOUND ON FASTENER HOLE H2, LOCATED ON CROSSBEAM SPLIC ING AREA FR16 RH SIDE ON PASSENGER…
- 3 Nov 2024
Crossbeam, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FASTENER HOLE H2, LOCATED ON CROSSBEAM SPLIC ING AREA FR16 LH SIDE ON PASSENGER CABIN. CRACK DEPTH = 0.113…
- 3 Nov 2024
Crossbeam, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON FASTENER HOLE H1, LOCATED ON CROSSBEAM SPLIC ING AREA FR16 LH SIDE ON PASSENGER CABIN. CRACK DEPTH = 0.106…
- 31 Oct 2023
Unknown, unknown
FLT#520, ATL-JFK. ' WING ANTI-ICE FAULT MESSAGE ON DESCENT AFTER SELECTING IT ON; ACCOMPLISHED WAI OPS CHECK PER AMM 30-11-00-710. OPS CHECK OK. MSG CLEARED.…
- 23 Oct 2023
Unknown, unknown
FLT#537, JFK-STI. '(AIRCRAFT PERFORMED AN AIR TURN BACK) 'FUMES REPORTED BY FLIGHT ATTEDENANTS IN THE FORWARD GALLEY; ACCOMPLISHED INFO NOTICE 2017-T015J. REF…
- 8 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: ENG 1 COMPRESSOR VANE; REPAIRS ACCOMPLISHED UNDER STS WO# 003031.REF. LOG PAGE # 3719161, ITEM 1 (THIS AIRCRAFT, AIRFRAME, AIRCRAFT…
- 8 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: PRESSURIZATION WILL NOT EXCEED 4.4 GOT EXCESSIVE CAB. ALT OUT OF FL210.; REPAIRS ACCOMPLISHED UNDER STS WO# 003031.REF. LOG PAGE #…
- 8 Jun 2023
Unknown, unknown
DURING HEAVY MAINTENANCE: RUDDER TRIM SWITCH CONTROL REQUIRES REPLACEMENT PER JETBLUE REQUEST; C/W PER STS WO#W003031 NRN W003031119. NO DEFECTS NOTED.
- 31 Jan 2023
Duct, failed
FLT#1979, DCA-FLL. 'WHILE CHECKING NRU BOWL PER TASK CARD A320-21-26-43-710-001. FOUND CORROSION AROUND SKIN AIR INLET VALVE; CORROSION FOUND TO BE ON INLET…
- 26 Dec 2022
Unknown, odor
FLT#1405, MCO-SDQ. DURING DECENT DIRTY SOCK SMELL IN ENTIRE CABIN; PERFORMED INFO NOTICE 2017-T015 PER TSM 05-50-00-810-085B. AIRCRAFT OF FOR SERVICE .
- 18 Sep 2022
None, none
FLT#1586, MCO-BUF. 'LEVEL 2 FUME EVENT PERSISTENT ODOR (MELTED CRAYON) DURING CLIMBOUT AND DESCENT ODOR DETECTED BY BOTH PILOTS AND ALL FA'S; MX-270 MISSING,…
- 2 Aug 2022
None, none
FLT#1568, PUJ-JFK. 'ON TAXI OUT, INFLIGHT CALLED UP REPORTING A PUNGENT ODOR. AGREED TO TAKE OFF TO SEE IF IT WOULD DISSIPATE. NO SMELL COMING FROM A/C…
- 24 Jan 2022
Stowage Box, failed
FLT #603, EWR-SDQ (DIVERTED TO FLL). LEAK IN CREW OXY SYSTEM PSI DROPPED FROM 1150 TO 750 OVER 2.5 HRS ; FOUND LEAK AT CAPTS OXYGEN STOWAGE BOX, REMOVED AND…
- 30 May 2021
Power Supply, failed
FLT 40, MDE-FLL. L2 & LEFT OWE DOORS SHOWING OPEN ON DOOR PAGE WHEN CLOSED; FOUND RELAY 12WN NOT SUPPLY HOT BATT BUS WHEN NOT ENERGIZED DRAIN EPSU BATTERY…
- 26 Apr 2021
Unknown, odor
FLT # 1225, JFK-TPA. FL EXPERIENCED A TINGLY FEELING IN HER MOUTH. ODOR POSSIBLY BURNING ELECTRIC,DETECTED BY CREW MOSTLY (STRONGEST) IN AFT CABIN ;…
- 20 Apr 2021
Cabin Air Sys, odor
FLT 928, MCO-SJU. DIRTY SOCK SMELL AFT CABIN APPROX PASSING 10000 FT ON DESCENT ; COMPLIED WITH INFO NOTICE 2017-T015F SEC. B APU PLACED ON MEL 36-12-02A, MX4…
- 11 Apr 2021
Apu, oil consumption
FLT 1448, LAS-JFK. VERY STRONG STENCH OF THE DIRTY SOCK SMELL. F/A & CUSTOMER COMPLAINED OF THE SMELL. THIS OCCURRED BETWEEN 6000 DOWN TO 2000 FT THEN THE…
- 8 Apr 2021
Ecs, odor
FLT 2836, STI-JFK. DIRTY SOCKS ODOR IN AFT CABIN, LEVEL 2 AND SLIGHTLY DETECTABLE IN FWD CABIN. NONE ON FLIGHT DECK. OCCURED DURING DESCENT THROUGH 8,000…
- 8 Feb 2021
Unknown, odor
FLT # 563, ORD-FLL. REPORTED AN ODOR EVENT ON DESCENT. “F/A REPORTED FUME ODOR ON FINAL FOR APPROX. 1 MINUTE”. THE CREW GENERATED A CABIN ODOR REPORT, AND…
- 8 Feb 2021
Battery, no test
FLT # 1141, BDL-PBI. R1 EPSU FAILED OPS TEST ; R & R R1 SVC DOOR POSITION EPSU W/SERVICEABLE ASSY PER AMM 33-50-01. OPS TEST OK
- 26 Nov 2020
Indication Sys, malfunctioned
FLT 1697, PHL-MCO. EMREGENCY DECLARED. INFLIGHT FUEL 1000 LBS TRANSFERRED FROM RIGHT INNER TO RIGHT OUTER TANK, LEFT SIDE DID NOT. FUEL TANK TEMP ON RIGHT…
- 1 Jun 2019
Epsu, no test
FT 391, L1 DOOR SLIDE FAILED EMERGENCY LIGHT TEST; R AND R L1 DOOR SLIDE ASSY IAW AMM 25-62-44. OPS CHK GOOD.
- 1 Jun 2019
Light, no test
FT # 391, L1 DOOR SLIDE FAILED EMERGENCY LIGHT TEST; R AND R L1 DOOR SLIDE ASSY IAW AMM 25-62-44. OPS CHK GOOD.
- 17 Aug 2018
Release Cable, failed
DURING HEAVY MAINTENANCE, THE RT OVERWING H RESERVOIR CABLE FAILED AN OPS CHECK; REMOVED AND REPLACED RT ESCAPE SLIDE RELEASE CABLE IAW AMM…
- 17 Aug 2018
Cable, no test
DURING HEAVY MAINTENANCE, THE LT OVERWING HATCH RESERVOIR CABLE FAILED AN OPS CHECK. REMOVED AND REPLACED THE FLEXIBLE CABLE IAW AMM 25-62-43-000-001-A, AND…
- 17 Aug 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RT SEAT TRACK AT FR 20 BEAM Y-1292; REMOVED AND REPLACED THE R2 DOOR SILL BEAM IAW SRM 51-72-11-911-001.…
- 17 Aug 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON L2 DOOR SILL DRAIN. CORRODED AROUND FASTENER'S AT FR 67 +14.00"; REMOVED AND REPLACED L2 DOOR SILL IAW…
- 17 Aug 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT CABIN FLOORBEAM Y1292 AT FR 66 +3.00"; BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM…
- 17 Aug 2018
Support Angle, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RT AFT SHEAR WEB SUPPORT ANGLE, AT FR 69 +19.00", STR 23R. HAS UPPER AND LOWER SURFACE CORROSION; AFTER…
- 17 Aug 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON L2 DOOR SILL FR 66 STR 23L; REPLACED DOOR SILL. REF NR 24430.
- 17 Aug 2018
Support Angle, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT SUPPORT ANGLE AT FR 20 BEAM Y1732; REMOVED AND REPLACED LT SUPPORT ANGLE AT FR 20 BEAM Y1732 IAW SRM…
- 17 Aug 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT FLOORBEAM Y1292 AT FR 67 +15; REMOVED AND REPLACED LT FLOORBEAM Y1292 FR 68-69 STR 23L IAW SRM…
- 17 Aug 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT FLOORBEAM AT Y1292, FRAME 67 +12.00". HAS CORROSION THAT IS BEYOND LIMITS AFTER BLEND-OUT (REF.…
- 17 Aug 2018
Support Angle, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT AFT SHEAR WEB SUPPORT ANGLE, AT FR 69, + 18.00", STR 23L. HAS CORROSION THAT IS BEYOND ALLOWABLE…
- 17 Aug 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RT FLOORBEAM AY -Y1292, FRAME 68 +10.00", STR 23R. HAS CORROSION THAT IS OUT OF LIMITS AFTER BLEND-OUT…
- 17 Aug 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RT FLOORBEAM -Y1292 UPPER SURFACE AT FR 66; REPLACED FLOORBEAM. WORK ACCOMPLISHED ON NR 24381.
- 17 Aug 2018
Web, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CARGO DR ENTRY WEB BOX HAS. A FEW AREAS OF CORR NEAR THRESHOLD; REF NR 440498-24446: REM & RPL AFT…
- 19 Oct 2017
Battery Pack, failed
RT EPSU BATTERY 12WL FAILED AN EMERGENCY LIGHT TEST. R & R THE BATTERY PACK IAW AMM 33-51-38, OPS CHECKED GOOD.
- 20 Apr 2015
Structure, contaminated
DURING HEAVY MAINTENANCE, DURING THE ACCOMPLISHMENT OF THE RUDDER SIDESHELL INSPECTION WATER INGRESSION FOUND AT HOIST POINT NR 3 IAW A320-55-1041-3. DURING…
- 20 Aug 2013
Sill, corroded
ON HEAVY MX CHECK, FOUND CORROSION ON LOWER SILL AFT PAX CABIN FRAME 68, STRINGER 23L AND FRAME 66, STRINGER 23L. ACCOMPLISHED REPAIR IAW WITH EC A13-534-01.
- 19 Aug 2013
Sill, corroded
DURING HEAVY CHECK, FOUND CORROSION ON LOWER SILL AT FRAME 66 STRINGER 23R AFT PAX CABIN. ACCOMPLISHED REPAIR TO THE R2 DOOR LOWER SILL BEAM IAW EO…
- 13 Jul 2013
Battery, failed
DURING MX, DISCOVERED THE EPSU AT FIN NR 10 BATTERY FAILED CAPACITY TEST. R & R BATTERY AT EPSU FIN NR 10 IAW AMM 33-51-38. OPS CHECKED NORMAL.
- 12 May 2010
Lamp, failed
ON GROUND, DURING MAINT CHECK LT EXT EMERGENCY LIGHT AFT INOP. RELAMPED LT WING EXT EMERGENCY LIGHT OPS CK GOOD.
- 23 Nov 2008
Power Supply, failed
EMERGENCY LIGHT TEST FAILED FWD EPSU. REMOVED AND REPLACED EPSU, OPS CHECK NORMAL IAW AMM 33-51-38-04.
- 3 May 2008
Unknown, odor
FLT 316, SAN-IAD, ON TAXI OUT, RETURNED TO GATE, BURNING SMELL COMING FROM REAR OF LAVATORY OF AIRCRAFT. T/S RT & LT AFT LAVS. NO C/B POPPED. WATER HEATERS…
- 11 Feb 2008
Unknown, odor
FLT 383, LGA-FLL, APPROXIMATELY 3 MINUTES PRIOR TO LANDING NR 1 F/A CALLED TO REPORT "BURNING SMELL" IN CABIN. NR 1 F/A TURNED OFF TV'S AND DID NOT SMELL IT…
- 10 Jun 2007
Bottle, cracked
L-1 ENTRY DOOR ASSIST BOTTLE LEAKING (CRACKED). REPLACED L-1 ENTRY DOOR ASSIST BOTTLE PER AMM 52-11-14, LEAK CHECK OK.