search

N567RP

2003 Embraer EMB-145LR standard FAA →

aircraft radio

earlier registrations

1 past record
  1. 2003

    Wells Fargo Trust Co Na Trustee

    2003 Embraer EMB-145LR

    deregistered 15 Jan 2019 exported to India

    s/n 145698 engine Rolls-Royc Ae 3007A1P

service difficulty reports

40 reports
  1. 18 May 2016

    Seal, damaged

    Emb EMB145LR

    LARGE GAP IN UPPER LT CORNER OF MAIN CABIN DOOR SEAL, WHEN CLOSED. FOUND MISSING SEALANT ON DOOR SEAL. APPLIED SEALANT TO UPPER LT CORNER OF MAIN CABIN DOOR…

  2. 21 Oct 2015

    Roller, bent

    Emb EMB145LR

    THE MAIN ENTRY DOOR ROLLER WAS FOUND BENT. MAINTENANCE R & R THE MAIN DOOR FRAME ROLLER SUPPORT ACTUATOR IAW AMM 53-21-02 AND ALL OPS CHECKS WERE GOOD. NO…

  3. 26 Jun 2015

    Support, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE RT OBSERVERS SEAT TRACK MOUNT FLANGE AT FRAME 33. MAINTENANCE REPLACED THE SUPPORT IAW SRM 51-40-02.

  4. 26 Jun 2015

    Support, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE RT OBSERVERS SEAT TRACK MOUNT FLANGE AT FRAME 52. MAINTENANCE REPLACED THE SUPPORT IAW SRM 51-40-02.

  5. 26 Jun 2015

    Skin, cracked

    Emb EMB145LR

    DURING INSPECTION, THE FUSELAGE SKIN WAS FOUND TO BE CRACKED AT FRAME 75 AND STRINGER 2L. THE SKIN WAS REPAIRED IAW ETD 2015-145-059490.

  6. 26 Jun 2015

    Threshold, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND AT THE SERVICE DOOR THRESHOLD AT FRAMES 20-22. THE CORROSION WAS REPAIRED IAW SRM 53-21-02AD AND SRM 53-21-02RE.

  7. 22 Jun 2015

    Floor Support, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE OMEGA BEAM AT FRAME 20. THE CORROSION WAS REPAIRED IAW SRM 53-00-10.

  8. 23 Dec 2014

    Filter, dirty

    Emb EMB145LR

    THE CREW REPORTED THAT THEY RECEIVED A BLEED 2 OVER TEMP MSG DURING CLIMB. THE CREW UTILIZED THE QRH & RETURNED TO FIELD. THE ACFT LANDED WITHOUT FURTHER…

  9. 27 Sep 2014

    Fitting, cracked

    Emb EMB145LR

    DURING INSPECTION THE AFT FUSELAGE END CLIP AT THE APU FIREWALL INSIDE ACCESS AT FRAME 81 & STRINGER 9R WAS FOUND TO BE CRACKED. THE END CLIP WAS REPLACED IAW…

  10. 27 Sep 2014

    Fitting, cracked

    Emb EMB145LR

    DURING INSPECTION THE AFT FUSELAGE END CLIP AT THE APU FIREWALL INSIDE ACCESS AT FRAME 81& STRINGER 8R WAS FOUND TO BE CRACKED. THE END CLIP WAS REPLACED IAW…

  11. 18 Aug 2014

    Light, inoperative

    Emb EMB145LR

    DURING INSPECTION THE EMER FLOOR PROXIMITY STRIP WAS FOUND TO BE INOPERATIVE AT ROW 8. R & R THE LIGHT STRIP & ALL OPERATIONAL CHECKS WERE GOOD.

  12. 24 Jan 2014

    Light, inoperative

    Emb EMB145LR

    DURING INSPECTION, THE EMERGENCY FLOOR LIGHT STRIP NEAR SEATS 3 - 7 WERE FOUND TO BE INOPERATIVE. REPLACED THE NR 2 EMERGENCY FLOOR LIGHT STRIP & ALL…

  13. 29 Dec 2013

    Unknown, malfunctioned

    Emb EMB145LR

    CREW REPORTED THE LOCALIZER LIST SIGNAL ON APPROACH TO KLGA. THE CREW DIVERTED TO KBDL & LANDED WITHOUT INCIDENT. THE CREW FURTHER NOTED NO LOCALIZER ISSUES…

  14. 5 Oct 2013

    Wire, broken

    Emb EMB145LR

    DURING INSPECTION, AN EMERGENCY LIGHT WAS FOUND TO HAVE BROKEN WIRES. REPLACED THE EMERGENCY LIGHT. OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED.

  15. 3 Oct 2013

    Sensor, failed

    Emb EMB145LR

    DURING FERRY FLIGHT, CREW RECEIVED A RUDDER SYSTEM 1/2 INOPERATIVE MESSAGE. FOLLOWED QUICK REFERENCE HANDBOOK AND MESSAGE REMAINED. FURTHER, DECLARED AN…

  16. 3 Oct 2013

    Sensor, failed

    Emb EMB145LR

    DURING FERRY FLIGHT FOR RUDDER SYSTEM 2 INOPERATIVE ISSUE, RECEIVED A RUDDER SYSTEM 1/2 INOPERATIVE MESSAGE. FOLLOWED QUICK REFERENCE HANDBOOK AND MESSAGE…

  17. 17 Aug 2013

    Light, inoperative

    Emb EMB145LR

    DURING INSPECTION, LT OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MX REPLACED THE LIGHT AND THE NR 1 BATTERY ASSEMBLY. OPS CHECKED GOOD AND NO…

  18. 17 Aug 2013

    Battery, inoperative

    Emb EMB145LR

    DURING INSPECTION, LT OVERWING EMERGENCY EXIT LIGHT FOUND TO BE INOPERATIVE. MX REPLACED LIGHT AND NR 1 BATTERY ASSEMBLY. OPS CHECKED GOOD AND NO FURTHER…

  19. 8 Jul 2013

    Stringer, corroded

    Emb EMB145LR

    DURING INSPECTION, STRINGER 21R FROM FRAME 7 TO FRAME 13 WAS FOUND TO BE CORRODED. THE STRINGER WAS REPLACED IAW SRM 51-40-02.

  20. 7 Jul 2013

    Floor Support, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE OMEGA BEAM UNDER DIGITAL AT Y=0.0 AT FRAMES 18, 20, AND 23. THE BEAM WAS REPAIRED IAW ETD 2013-145-014355.

  21. 7 Jul 2013

    Support, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE AILERON DISCONNECT, RT QUADRANT SUPPORT WEB FRAME 13-14. THE SUPPORT WAS REPLACED IAW SRM 51-40-02.

  22. 5 Jul 2013

    Floor Support, corroded

    Emb EMB145LR

    DURING INSPECTION, THE ANGLE CAP ON THE LEFT OMEGA BEAM AT FRAME 20 WAS FOUND TO BE CORRODED. THE ANGLE CAP ON THE OMEGA BEAM WAS REPLACED IAW SRM 53-00-10.

  23. 14 Feb 2013

    Light, inoperative

    Emb EMB145LR

    DURING INSPECTION, THE FIRST EMERGENCY LIGHT FLOOR PROXIMITY STRIP WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY FLOOR LIGHT PROXIMITY STRIP…

  24. 10 Nov 2011

    Battery, discharged

    Emb EMB145LR

    DURING INSPECTION, THE LEFT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE NUMBER 3 EMERGENCY LIGHT BATTERY, OPERATIONAL…

  25. 24 Jun 2011

    Sill, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE CABIN FLOOR STRUCTURE FORWARD SERVICE DOOR SILL. MAINTENANCE REPAIRED THE CABIN FLOOR STRUCTURE FORWARD SERVICE…

  26. 22 Jun 2011

    Door Frame, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE CARGO DOOR CUT OUT STRUCTURE FORWARD L-SHAPE. MAINTENANCE REPAIRED THE CARGO DOOR CUT OUT STRUCTURE FORWARD…

  27. 22 Jun 2011

    Floorbeam, corroded

    Emb EMB145LR

    DURING INSPECTION, CORROSION WAS FOUND ON THE CARGO FLOOR STRUCTURE ENTRANCE AREA LOWER BEAM. MAINTENANCE REPLACED THE CARGO FLOOR STRUCTURE ENTRANCE AREA…

  28. 22 Mar 2011

    Sealant, damaged

    Emb EMB145LR

    CREW REPORTED THAT DURING CRUISE HEARD A STRANGE NOISE IN THE COCKPIT. THE CREW DIVERTED TO KCLE AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE…

  29. 15 Mar 2011

    Windshield, cracked

    Emb EMB145LR

    DURING CLIMBOUT, THE FLIGHT CREW REPORTED THAT THE CAPTAIN'S WINDSHIELD OUTER PANE CRACKED. THE AIRCRAFT DIVERTED TO KCMH AND LANDED WITHOUT INCIDENT.…

  30. 23 Jan 2011

    Battery, discharged

    Emb EMB145LR

    DURING INSPECTION, THE NR 4 OVERHEAD EMERGENCY LIGHT AND THE NR 3 AFT FLOOR PROXIMITY SWITCH WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE NR 4…

  31. 23 Jan 2011

    Light, inoperative

    Emb EMB145LR

    DURING INSPECTION BOTH OF THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED BOTH LIGHTS WITH NO FURTHER DEFECTS NOTED.

  32. 7 Sep 2010

    Actuator, slow

    Emb EMB145LR

    DURING CLIMB OUT OF BOS THE CREW REPORTED A PTRIM MAIN INOP MESSAGE ON EICAS. THE QRH WAS FOLLOWED AND THE FLIGHT RETURNED TO FIELD AND LANDED WITHOUT…

  33. 8 May 2010

    Light, inoperative

    Emb EMB145LR

    DURING INSPECTION, TWO FLOOR PROXIMITY LIGHT STRIPS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE PROXIMITY LIGHT STRIPS IAW AMM 33-50-12.

  34. 22 May 2009

    O-Ring, leaking

    Emb EMB145LR

    THE FLIGHT CREW RECEIVED A BLEED 1 LEAK MESSAGE AFTER TAKEOFF. THE QRH WAS FOLLOWED AND THE MESSAGE CLEARED. THE ACFT RETURNED AND LANDED WITHOUT INCIDENT. MX…

  35. 20 Apr 2009

    Battery Pack, discharged

    Emb EMB145LR

    DURING INSPECTION THE AFT OVERWING EMERGENCY LIGHTS ON BOTH SIDES OF THE AIRCRAFT WERE FOUND TO BE INOP. THE AFT CABIN BATTERY POWER SUPPLY WAS REPLACED AND…

  36. 18 Jan 2009

    Unknown, odor

    Emb EMB145LR

    FLIGHT 6097, CVG TO MKE, DURING CLIMB THE FLIGHT CREW RECEIVED A LAV SMOKE ALARM AND EICAS INDICATION. THE FLIGHT ATTENDANT ALSO CALLED THE COCKPIT AND…

  37. 17 Jan 2009

    Battery Pack, inoperative

    Emb EMB145LR

    DURING INSPECTION, MAINTENANCE FOUND THE LEFT AND RIGHT-HAND OVERWING EMERGENCY LIGHTS TO BE INOP. THE NR 4 EMERGENCY LIGHT BATTERY WAS REPLACED AND THE…

  38. 18 Mar 2008

    Power Supply, inoperative

    Emb EMB145LR

    DURING INSPECTION THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE NON FUNCTIONAL. THE NR 4 EMERGENCY LIGHT POWER SUPPLY WAS REPLACED AND THE OVERWING EMERGENCY…

  39. 17 Mar 2008

    Control Unit, malfunctioned

    Emb EMB145LR

    CVG TO GSP - DURING CLIMB-OUT, THE CREW RECEIVED AN AMBER EICAS SPOILER FAIL MESSAGE. THE APPROPRIATE CHECKLISTS WERE FOLLOWED IN THE QRH AND THE AIRCRAFT…

  40. 13 Jul 2006

    Tire, separated

    Emb EMB145LR

    FLIGHT 6395 - TLH-TPA - TAKEOFF FROM TLH APPEARED NORMAL. EN ROUTE, JAX CENTER CALLED, TLH HAD CONTACTED THEM TO ADVISE THAT MAY HAVE BLOWN A TIRE ON TAKEOFF.…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05624 Nov 2026
FCC GMRS633,27224 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,84423 Nov 2026
FAA registered aircraft319,59223 Nov 2026
FAA N-number reservations126,12623 Nov 2026
FAA dealers12,51023 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,33524 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.