N567RP
2003 Embraer EMB-145LR standard FAA →
aircraft radio
earlier registrations
1 past record
- 2003
service difficulty reports
40 reports
- 18 May 2016
Seal, damaged
LARGE GAP IN UPPER LT CORNER OF MAIN CABIN DOOR SEAL, WHEN CLOSED. FOUND MISSING SEALANT ON DOOR SEAL. APPLIED SEALANT TO UPPER LT CORNER OF MAIN CABIN DOOR…
- 21 Oct 2015
Roller, bent
THE MAIN ENTRY DOOR ROLLER WAS FOUND BENT. MAINTENANCE R & R THE MAIN DOOR FRAME ROLLER SUPPORT ACTUATOR IAW AMM 53-21-02 AND ALL OPS CHECKS WERE GOOD. NO…
- 26 Jun 2015
Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE RT OBSERVERS SEAT TRACK MOUNT FLANGE AT FRAME 33. MAINTENANCE REPLACED THE SUPPORT IAW SRM 51-40-02.
- 26 Jun 2015
Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE RT OBSERVERS SEAT TRACK MOUNT FLANGE AT FRAME 52. MAINTENANCE REPLACED THE SUPPORT IAW SRM 51-40-02.
- 26 Jun 2015
Skin, cracked
DURING INSPECTION, THE FUSELAGE SKIN WAS FOUND TO BE CRACKED AT FRAME 75 AND STRINGER 2L. THE SKIN WAS REPAIRED IAW ETD 2015-145-059490.
- 26 Jun 2015
Threshold, corroded
DURING INSPECTION, CORROSION WAS FOUND AT THE SERVICE DOOR THRESHOLD AT FRAMES 20-22. THE CORROSION WAS REPAIRED IAW SRM 53-21-02AD AND SRM 53-21-02RE.
- 22 Jun 2015
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE OMEGA BEAM AT FRAME 20. THE CORROSION WAS REPAIRED IAW SRM 53-00-10.
- 23 Dec 2014
Filter, dirty
THE CREW REPORTED THAT THEY RECEIVED A BLEED 2 OVER TEMP MSG DURING CLIMB. THE CREW UTILIZED THE QRH & RETURNED TO FIELD. THE ACFT LANDED WITHOUT FURTHER…
- 27 Sep 2014
Fitting, cracked
DURING INSPECTION THE AFT FUSELAGE END CLIP AT THE APU FIREWALL INSIDE ACCESS AT FRAME 81 & STRINGER 9R WAS FOUND TO BE CRACKED. THE END CLIP WAS REPLACED IAW…
- 27 Sep 2014
Fitting, cracked
DURING INSPECTION THE AFT FUSELAGE END CLIP AT THE APU FIREWALL INSIDE ACCESS AT FRAME 81& STRINGER 8R WAS FOUND TO BE CRACKED. THE END CLIP WAS REPLACED IAW…
- 18 Aug 2014
Light, inoperative
DURING INSPECTION THE EMER FLOOR PROXIMITY STRIP WAS FOUND TO BE INOPERATIVE AT ROW 8. R & R THE LIGHT STRIP & ALL OPERATIONAL CHECKS WERE GOOD.
- 24 Jan 2014
Light, inoperative
DURING INSPECTION, THE EMERGENCY FLOOR LIGHT STRIP NEAR SEATS 3 - 7 WERE FOUND TO BE INOPERATIVE. REPLACED THE NR 2 EMERGENCY FLOOR LIGHT STRIP & ALL…
- 29 Dec 2013
Unknown, malfunctioned
CREW REPORTED THE LOCALIZER LIST SIGNAL ON APPROACH TO KLGA. THE CREW DIVERTED TO KBDL & LANDED WITHOUT INCIDENT. THE CREW FURTHER NOTED NO LOCALIZER ISSUES…
- 5 Oct 2013
Wire, broken
DURING INSPECTION, AN EMERGENCY LIGHT WAS FOUND TO HAVE BROKEN WIRES. REPLACED THE EMERGENCY LIGHT. OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED.
- 3 Oct 2013
Sensor, failed
DURING FERRY FLIGHT, CREW RECEIVED A RUDDER SYSTEM 1/2 INOPERATIVE MESSAGE. FOLLOWED QUICK REFERENCE HANDBOOK AND MESSAGE REMAINED. FURTHER, DECLARED AN…
- 3 Oct 2013
Sensor, failed
DURING FERRY FLIGHT FOR RUDDER SYSTEM 2 INOPERATIVE ISSUE, RECEIVED A RUDDER SYSTEM 1/2 INOPERATIVE MESSAGE. FOLLOWED QUICK REFERENCE HANDBOOK AND MESSAGE…
- 17 Aug 2013
Light, inoperative
DURING INSPECTION, LT OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MX REPLACED THE LIGHT AND THE NR 1 BATTERY ASSEMBLY. OPS CHECKED GOOD AND NO…
- 17 Aug 2013
Battery, inoperative
DURING INSPECTION, LT OVERWING EMERGENCY EXIT LIGHT FOUND TO BE INOPERATIVE. MX REPLACED LIGHT AND NR 1 BATTERY ASSEMBLY. OPS CHECKED GOOD AND NO FURTHER…
- 8 Jul 2013
Stringer, corroded
DURING INSPECTION, STRINGER 21R FROM FRAME 7 TO FRAME 13 WAS FOUND TO BE CORRODED. THE STRINGER WAS REPLACED IAW SRM 51-40-02.
- 7 Jul 2013
Floor Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE OMEGA BEAM UNDER DIGITAL AT Y=0.0 AT FRAMES 18, 20, AND 23. THE BEAM WAS REPAIRED IAW ETD 2013-145-014355.
- 7 Jul 2013
Support, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE AILERON DISCONNECT, RT QUADRANT SUPPORT WEB FRAME 13-14. THE SUPPORT WAS REPLACED IAW SRM 51-40-02.
- 5 Jul 2013
Floor Support, corroded
DURING INSPECTION, THE ANGLE CAP ON THE LEFT OMEGA BEAM AT FRAME 20 WAS FOUND TO BE CORRODED. THE ANGLE CAP ON THE OMEGA BEAM WAS REPLACED IAW SRM 53-00-10.
- 14 Feb 2013
Light, inoperative
DURING INSPECTION, THE FIRST EMERGENCY LIGHT FLOOR PROXIMITY STRIP WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY FLOOR LIGHT PROXIMITY STRIP…
- 10 Nov 2011
Battery, discharged
DURING INSPECTION, THE LEFT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE NUMBER 3 EMERGENCY LIGHT BATTERY, OPERATIONAL…
- 24 Jun 2011
Sill, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE CABIN FLOOR STRUCTURE FORWARD SERVICE DOOR SILL. MAINTENANCE REPAIRED THE CABIN FLOOR STRUCTURE FORWARD SERVICE…
- 22 Jun 2011
Door Frame, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE CARGO DOOR CUT OUT STRUCTURE FORWARD L-SHAPE. MAINTENANCE REPAIRED THE CARGO DOOR CUT OUT STRUCTURE FORWARD…
- 22 Jun 2011
Floorbeam, corroded
DURING INSPECTION, CORROSION WAS FOUND ON THE CARGO FLOOR STRUCTURE ENTRANCE AREA LOWER BEAM. MAINTENANCE REPLACED THE CARGO FLOOR STRUCTURE ENTRANCE AREA…
- 22 Mar 2011
Sealant, damaged
CREW REPORTED THAT DURING CRUISE HEARD A STRANGE NOISE IN THE COCKPIT. THE CREW DIVERTED TO KCLE AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE…
- 15 Mar 2011
Windshield, cracked
DURING CLIMBOUT, THE FLIGHT CREW REPORTED THAT THE CAPTAIN'S WINDSHIELD OUTER PANE CRACKED. THE AIRCRAFT DIVERTED TO KCMH AND LANDED WITHOUT INCIDENT.…
- 23 Jan 2011
Battery, discharged
DURING INSPECTION, THE NR 4 OVERHEAD EMERGENCY LIGHT AND THE NR 3 AFT FLOOR PROXIMITY SWITCH WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE NR 4…
- 23 Jan 2011
Light, inoperative
DURING INSPECTION BOTH OF THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED BOTH LIGHTS WITH NO FURTHER DEFECTS NOTED.
- 7 Sep 2010
Actuator, slow
DURING CLIMB OUT OF BOS THE CREW REPORTED A PTRIM MAIN INOP MESSAGE ON EICAS. THE QRH WAS FOLLOWED AND THE FLIGHT RETURNED TO FIELD AND LANDED WITHOUT…
- 8 May 2010
Light, inoperative
DURING INSPECTION, TWO FLOOR PROXIMITY LIGHT STRIPS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE PROXIMITY LIGHT STRIPS IAW AMM 33-50-12.
- 22 May 2009
O-Ring, leaking
THE FLIGHT CREW RECEIVED A BLEED 1 LEAK MESSAGE AFTER TAKEOFF. THE QRH WAS FOLLOWED AND THE MESSAGE CLEARED. THE ACFT RETURNED AND LANDED WITHOUT INCIDENT. MX…
- 20 Apr 2009
Battery Pack, discharged
DURING INSPECTION THE AFT OVERWING EMERGENCY LIGHTS ON BOTH SIDES OF THE AIRCRAFT WERE FOUND TO BE INOP. THE AFT CABIN BATTERY POWER SUPPLY WAS REPLACED AND…
- 18 Jan 2009
Unknown, odor
FLIGHT 6097, CVG TO MKE, DURING CLIMB THE FLIGHT CREW RECEIVED A LAV SMOKE ALARM AND EICAS INDICATION. THE FLIGHT ATTENDANT ALSO CALLED THE COCKPIT AND…
- 17 Jan 2009
Battery Pack, inoperative
DURING INSPECTION, MAINTENANCE FOUND THE LEFT AND RIGHT-HAND OVERWING EMERGENCY LIGHTS TO BE INOP. THE NR 4 EMERGENCY LIGHT BATTERY WAS REPLACED AND THE…
- 18 Mar 2008
Power Supply, inoperative
DURING INSPECTION THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE NON FUNCTIONAL. THE NR 4 EMERGENCY LIGHT POWER SUPPLY WAS REPLACED AND THE OVERWING EMERGENCY…
- 17 Mar 2008
Control Unit, malfunctioned
CVG TO GSP - DURING CLIMB-OUT, THE CREW RECEIVED AN AMBER EICAS SPOILER FAIL MESSAGE. THE APPROPRIATE CHECKLISTS WERE FOLLOWED IN THE QRH AND THE AIRCRAFT…
- 13 Jul 2006
Tire, separated
FLIGHT 6395 - TLH-TPA - TAKEOFF FROM TLH APPEARED NORMAL. EN ROUTE, JAX CENTER CALLED, TLH HAD CONTACTED THEM TO ADVISE THAT MAY HAVE BLOWN A TIRE ON TAKEOFF.…