N566UA
1992 Boeing 757-222 standard FAA →
reservations
earlier registrations
1 past record
- 1992
service difficulty reports
118 reports
- 9 Feb 2014
Wire, damaged
RT WING FUELING PANEL DOOR INBD LIGHT INOPERATIVE. WIRING PULLED OUT OF LIGHT HOUSING. EXPOSED CONDUCTOR WIRE TOWARDS WING AREA, THIS EXPOSED WIRING WAS AN…
- 16 Dec 2013
Guard, out of adjust
EMERGENCY EXIT LIGHTS COME ON IN THE OFF POSITION. CREW REPORTS WHEN EMERGENCY LIGHTS SWITCH IS TURNED OFF, EMERGENCY LIGHTS ILLUMINATE. FOUND AFT ATTENDANT…
- 24 Nov 2013
Idg, failed
LT GEN OFF LIGHT ILLUMINATED, RTFL. CREW CYCLED IAW FM & GEN RETURNED. CLIMBING THRU 24K LOSS OF LT BUS WITH ASSOCIATED LIGHT, LT GEN OFF LIGHT & APU ON…
- 9 Oct 2013
O-Ring, damaged
ON WALK AROUND FLT CREW REPORTS NR 1 ENG STRUT DRAIN LINE, LARGE LINE NR 2 LEAKING. REPLACED O-RING ON UPPER INBD HYD UNION ON THRUST REVERSER DIRECTIONAL…
- 29 Sep 2013
Switch, contaminated
LT MLG DOOR UNSAFE LIGHT IS INOPERATIVE. RELAMPED, NO HELP. FOUND SW S10371 FULL OF HYD FLUID & DETERIORATED ON TOP OF SW. CLEANED LIGHT ASSEMBLY, CONTACTS &…
- 9 Jul 2013
Light, inoperative
EMERGENCY LIGHT JUST AFT OF L1 DOOR INOPERATIVE. INSTALLED NEW EMERGENCY LIGHT, OPS CHECKED SATISFACTORY.
- 9 Jul 2013
Light, contaminated
EMERGENCY LIGHT JUST AFT OF L2 DOOR INOPERATIVE. FOUND WATER UNDER EMERGENCY LIGHT COVER. DRIED OUT WATER. OPS CHECKED SATISFACTORY.
- 20 Jun 2013
Lamp, wrong part
R3 DOOR EVAC SLIDE LIGHT ABOVE DOOR ILLUMINATED. DOOR SLIDE LIGHT STAYS ON ALL THE TIME. FOUND INCORRECT LAMP ASSY, CLEANED AND REPLACED LAMP ASSY, OPS NORMAL…
- 19 Jun 2013
Microphone, malfunctioned
CREW O2 MASK MICROPHONE HOT. R & R MASK IAW MM. MASK OPS NORMAL BUT STILL HAVE HOT MICROPHONE PROB. PERFORMED OPS CHECK, MASK MIC IS NORMAL OPERATION.
- 18 Jun 2013
Connector, disconnected
EMERGENCY LIGHT IN FRONT OF L2 DOOR IS INOPERATIVE. CONNECTED EMERGENCY LIGHT. OPS CHECKED GOOD, OK FOR SERVICE.
- 10 Jun 2013
Filter, failed
DURING CLIMB, OIL FILTER ON EICAS. RETURNED TO FIELD. R & R OIL FILTER IAW IAW, NO LEAKS NOTED.
- 1 May 2013
Light, inoperative
EEL LIGHT INOP AT FWD CLOSET. REPLACED LEAD IN P/N 5879 -1 & CONNECTOR P/N 5878-1 PER MM & REPLACED LAMP P/N 36262-4 PER MM. REPLACED END CAPS & LENS COVER.
- 1 May 2013
Light, inoperative
EEL LIGHT INOP AT ROW 38. REPLACED LAMP P/N 36262-4 PER MM. ACP'D IDT OF EEL LIGHT INSTALLATION AT ROW 38.
- 11 Apr 2013
Feeder Cable, defective
FLOOR EEL LIGHT LOCATED IN FRONT OF FORWARD CLOSET IS INOP. OTHER EEL LIGHTS IN AREA WORK FINE. REPAIRED EEL LIGHT FEEDER. OP CHECK SATISFACTORY.
- 19 Mar 2013
Fan, inoperative
HOT ODOR FOR 2-3 MINUTES AFTER TAKEOFF, WENT AWAY BY ITSELF, DE ICE WAS NOT AN ISSUE. ACCOMPLISHED AC SYSTEM CHECK. REF MM 21-00-01-301 PROCEDURE 1. BEGAN FIM…
- 28 Feb 2013
Skin, dented
AFT FUSELAGE SKIN DENTED AT STA 1606 STR 23L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SKIN, ACP'D HFEC OF SKIN CUT-OUT & FASTENER HOLES. NO DEFECT NOTED.…
- 28 Feb 2013
Skin, dented
AFT FUSELAGE SKIN DENTED AT STA 1549 STR 23L. MAJOR REPAIR ACCOMPLISHED. MAINT TEXT: CUT OUT DAMAGED SKIN, ACP'D HFEC OF SKIN CUT-OUT & FASTENER HOLES. NO…
- 28 Feb 2013
Feeder Cable, defective
CABIN 'A' ZONE EMERGENCY LIGHT INOPERATIVE. REPAIRED 'A' ZONE EMERGENCY LIGHT FEEDER CABLE, OPS CHECKED GOOD.
- 28 Feb 2013
Battery Pack, discharged
RIGHT OVERWING EXIT LIGHT INOPERATIVE. REPLACED RIGHT OVERWING EXIT LIGHT BATTERY PACK PER AMM, OPS CHECK GOOD.
- 28 Feb 2013
Feeder Cable, defective
'C' ZONE EEL ROW 29 ABC 37ABC INOPERATIVE. REMOVED AND REPLACED FEEDER IAW B757 MM, OPS CHECKS GOOD.
- 26 Feb 2013
Web, corroded
MAIN CABIN SUB FLOOR WEB, CORRODED SEVERAL PLACES BS 1680, RBL 40 - 60. REMOVED AND REPLACED WEB IAW 51-40 02 AND ECRA 5330-04259. REPAIR DOUBLER INSTALLED.…
- 26 Feb 2013
Stringer, damaged
BS 610 STRINGER 17L HAS DOUBLE DRILLED HOLE. REPAIRED STRINGER IAW ECRA 5361-01040 AND REO 615957 REV A. MAJOR REPAIR.
- 26 Feb 2013
Frame, gouged
FWD CARGO DOOR LOWER END ATTACH FRAME IS GOUGED IN SEVERAL PLACES. REMOVED AND REPLACED LOWER ATTACHED FRAME IAW SRM. MAJOR REPAIR.
- 26 Feb 2013
Skin, dented
SKIN DENTED BS 610, S16-17L. HFEC INSPECTED, NO CRACKS NOTED. REPAIRED. MAJOR.
- 26 Feb 2013
Skin, dented
SMALL DENTS IN AFT FUSELAGE BS 1549 - 1606 JUST ABOVE CARGO FLOOR LINE. ACCOMPLISHED HFEC INSPECTION AND FOUND NO CRACKS. REPAIRED.
- 26 Feb 2013
Skin, damaged
DENT ARCHIVE ITEM APPEARS TO HAVE ADDITIONAL DAMAGE OVER WHAT IS DESCRIBED IN ARCHIVED TXT. AT BS 610, STR 16L TO 17L. REPAIRED AREA IAW SRM 53-00-01 REPAIR…
- 25 Feb 2013
Stringer, cracked
MAIN CABIN STRINGER 18L AT BS 620 CRACKED ON LOWER FLANGE. REPAIRED STRINGER IAW SRM 53-00-03, REPAIR 1. CATEGORY 'A' MAJOR REPAIR.
- 25 Feb 2013
Floorbeam, corroded
MAIN CABIN FLOORBEAM UPPER TEE CORRODED AT BS 1640, LBL 5 - RBL 62. FABRICATED & INSTALLED NEW FLOORBEAM TEE IAW SRM 53-00-51, FIG 201. MAJOR REPAIR.
- 16 Jan 2013
Receptacle, failed
CARGO FIRE LIGHT FAILED TO ILLUMINATE DURING ENGINE APU CARGO FIRE OVERHEAT TEST. EICAS MESSAGE (AFT CARGO FIRE) WAS NOT DISPLAYED. AFT CARGO ARM SWITCH DOES…
- 30 Aug 2012
Wedge, damaged
DAMAGE TO RIGHT I/B FLAP AFT I/B TRAILING EDGE WEDGE. MEASURES APPROX 8IN BY 3IN. WILL REQUIRE PERM REPAIR PER SRM. MATERIAL ETA 0730 UNDER OSTF'S LISTED.…
- 29 Aug 2012
Windshield, delaminated
NR 1 RIGHT WINDSHIELD DELAMINATION. REPLACE NR 1 RT WINDSHIELD PER AMM. ENSURE COA 507402 IS ACCOMPLISHED WHICH REPLACES THE WINDSHIELD WITH A PIN & SOCKET…
- 8 Aug 2012
Seal, leaking
CHRONIC DOOR 1R SQUEAL. RECONDITIONED AND SANDED REN AND CLEANED SEALING SURFACES. DOOR 1 RT UPPER GATE SEAL OUT OF RETAINER AT FWD EDGE. REINSTALLED UPPER…
- 5 Jul 2012
Gate, cracked
DR 2R HAS CRACK .25 LONG AT UPPER HINGE CUTOUT. ALSO FOUND R1 DOOR UPPER GATE CRACKED AT SECOND RIVET.
- 5 Jul 2012
Gate, cracked
DOOR 2R UPPER HINGE CUTOUT CRACKED AND SMC5 DOOR 1R UPPER GATE CRACKED. REMOVED DOOR 2R. ACCOMPLISHED CHECK. REPAIRED PER MM.
- 2 Jul 2012
Igniter, arced
NR 1 ENGINE LOWER IGNITER AND LEAD SHOW EVIDENCE OF ARCING. REPLACED LOWER IGNITER AND LEAD ASSY.
- 26 Jun 2012
Cover, damaged
EMERGENCY FLOOR PATH LIGHTING, CLEAR PLASTIC COVER DAMAGED FROM ROWS 8 TO 12C. INSTALLED NEW CLEAR PLASTIC COVER SECTION AND OP CHECKED LIGHT STRIP. EEL STRIP…
- 10 Jun 2012
Connector, damaged
EMERGENCY LIGHT INOPERATIVE APPROXIMATELY SEAT ROW 11. ONE EACH ORANGE AND WHITE SECTION INOPERATIVE. SPLICED IN A NEW CONNECTOR IAW MM 33-51-96.
- 10 Jun 2012
Light, inoperative
UPON IDT INSPECTION OF LM3881 FOUND ONE EMERGENCY LIGHT STRIP ORANGE INOPERATIVE. LOCATED AT FWD LT OVERWING DOOR AREA. LIGHT STRIP OPS CHECKED OK.
- 10 Jun 2012
Light, inoperative
EMERGENCY LIGHT INOPERATIVE AT DOOR 2 LEFT, IN FRONT OF LAVATORY DOOR. REPLACED LIGHT.
- 16 Mar 2012
Flap, malfunctioned
FLAPS ASYMMETRY FLAP STUCK AT 20 ONLY ONE SIDE WILL EXTEND PAST 20. INSPECTED FLAPS & SLATS. NO DISCREPANCIES FOUND. ACCOMPLISHED OPERATIONAL CHECK PER MM.
- 29 Feb 2012
Armrest, faulty
SHOULD READ SEAT 27C ARMREST CAP STUCK IN UP POS. MADE TEMP REPAIR WITH TAPE TAP2502-1-0300. REPLACED ARMREST AT 27C.
- 29 Feb 2012
Actuator, faulty
RIGHT TANK WILL NOT TAKE FUEL. TRIED OPENING VALVE MANUALLY, NO HELP. REPLACE RT FUELING VALVE ACTUATOR PER MM. OPS CHECK GOOD, NO LEAKS.
- 18 Dec 2011
Connector, unsecure
EMERGENCY LIGHT INOPERATIVE AT ROW 11. SECURED CONNECTOR AT LIGHT ASSY.
- 17 Dec 2011
Connector, broken
EMERGENCY LIGHT LOOSE BY FWD LAVATORY. THE PROBLEM IS WITH THE MALE POWER CONNECTOR WHICH RUNS FROM THE BATTERY PACK TO THE LIGHT. BOTH PINS ARE BROKEN.…
- 1 Oct 2011
Unknown, odor
F/A REPORTED ODOR OF BURNING RUBBER AT DOOR 2 ON DESCENT. PERFORMED INSPECTION OF AREA. MID LAV, MID GALLEY, LIGHTS, DOOR AREA, VIDEO MONITOR, ALL IN ON…
- 26 Sep 2011
Door, leaking
DOOR 1R MAKES AIR LEAK NOISES DURING CLIMBOUT. PRESSURIZED TO 4 PSI, FOUND MULTI AIR LEAKS. REPAIRED
- 22 Sep 2011
Lamp, inoperative
EMEGENCY LIGHT DAMAGED LEFT SIDE FROM EMERGENCY EXIT TO DOOR 2L. REPLACED AND INSTALLED NEW LAMP AND CLEAR STRIP COVER.
- 20 Sep 2011
Light, inoperative
AFT R DOOR SLIDE LIGHT WON'T ILLUMINATE. DOOR 3R DOOR SLIDE RELAMPED.
- 14 Aug 2011
Engine, making metal
ENGINE NR 2 VIB N1 3.7 IN CLIMB TO FL390 CRUISE. SAMC TEXT: CREW REPORTS VIBES FELT AND INDICATION AMPLITUDE MATCHED THROTTLE MOVEMENT. NEED TO TROUBLESHOOT…
- 12 Aug 2011
Engine, making metal
CREW REPORT: ENGINE NR 2 VIB N1 3.7 IN CLIMB TO FL390 CRUISE1.1. SAMC TEXT: CREW REPORTS VIBES FELT AND INDICATION AMPLITUDE MATCHED THROTTLE MOVEMENT. NEED…
- 20 Jun 2011
Lamp, inoperative
DOOR NR 1 LT AND RT EMERGENCY EXIT LIGHTS INOPERATIVE. RELAMPED, OPERATES NORMAL.
- 8 May 2011
Indicator, faulty
CREW REPORTS ON APPROACH WHEN FLAP HANDLE MOVED FROM 5 TO 15, RT NEEDLE NEVER MOVED FROM 5 AND LEFT NEEDLE MOVED TO 15. FLAPS LOCKED OUT WITH EICAS MESSAGE…
- 22 Apr 2011
Wire Harness, disconnected
AT 16ABC EMERGENCY EXIT LIGHTS DETACHED. FOUND LOOSE CONNECTION IN EMERGENCY LIGHT WIRE HARNESS, RECONNECTED AND ALL OPS CHECKED NORMAL.
- 7 Apr 2011
Attach Bracket, out of tolerance
RIGHT INBOARD TE AFT FLAP, INBOARD PUSHROD ATTACH BRACKET HAS BEARING LOOSE AND COMING OUT OF BRACKET. REPLACED BRACKET AND BEARING ASSY. BRACKET IS SECURED…
- 6 Apr 2011
Steering Sys, out of adjust
AIRPLANE PULLS LEFT DURING TAXI. ADJUSTED NOSE WHEEL STEERING, TAXI TEST GOOD.
- 30 Mar 2011
Structure, corroded
GALLEY G4B FLOOR DECK IS CORRODED FROM STA 1686, LBL 20 TO RBL 58. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND AREAS TO BE OUT OF LIMITS PER SRM.…
- 30 Mar 2011
Pan, corroded
GALLEY G4B FLOOR PAN IS CORRODED FROM STA 1680 TO 1686 LBL 20 TO RBL 58. MAJOR REPAIR ACCOMPLISHED: REPAIRED WITH PTT SEQ 2572135 UNDER PEMCO EA PD57-53-097.…
- 29 Mar 2011
Crease Beam, corroded
RIGHT CREASE BEAM UPPER SURFACE HAS CORROSION AT BS 975 AT RBL 71. MAJOR REPAIR ACCOMPLISHED: CORROSION FOUND TO BE OUT OF LIMITS PER SRM. FABRICATED NEW…
- 28 Mar 2011
Crease Beam, corroded
LEFT CREASE BEAM O/B FLANGE COMMON TO INTERNAL FUSELAGE CORRODED AT STA 1006, LBL 71. AGING ACFT INSP FINDINGS. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION,…
- 28 Mar 2011
Beam, corroded
AFT CARGO COMPARTMENT STATION 1620 LAP BEAM AT SW-30 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FABBED AND INSTALLED REPAIR DOUBLER PER…
- 28 Mar 2011
Floorbeam, corroded
STATION 324 RBL 41 FLOORBEAM HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED FLOORBEAM STA 324, RBL 41 IAW PEMCO EA PD57-536-096.
- 25 Mar 2011
Floorbeam, corroded
FLOORBEAM HAS CORROSION AT STATION 1661 LBL 11 AND RBL 4. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED AREA OF…
- 25 Mar 2011
Floorbeam, corroded
STATION 365.25 RBL 0 TO RBL 40 FLOORBEAM IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND ARE TO BE OUT OF LIMITS. REMOVED TEE CHORD AND…
- 25 Mar 2011
Floorbeam, corroded
CORROSION ON CABIN FLOOR BEAM AT STA 1640 AT RBL 14 TO RBL 40. MAJOR REPAIR ACCOMPLISHED: REMOVED TEE ANGLE IAW SRM, DUE TO EXCESSIVE MATERIAL REMOVED AND OUT…
- 24 Mar 2011
Shear Tie, corroded
AFT CARGO PIT CORROSION DISCOVERED AT BS 1620 ON SHEAR TIE AT S-30. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION REMOVAL IT WAS DISCOVERED TO BE BEYOND LIMITS…
- 5 Mar 2011
Smoke Detector, unknown
EQUIP COOL SMOKE DETECTORS NEEDS REPLACEMENT. REPLACED EQUIP COOL SMOKE DETECTORS ON TASKCARD.
- 30 Dec 2010
Fan, faulty
ELECTRICAL ODOR IN COCKPIT, FLIGHT DIVERTED. FOUND EQP COOLING SUPPLY FAN NR1 TO BE SOURCE OF ODOR. REPLACED EQUIPMENT COOLING FAN NR 1, OPS CHESKED OK.
- 14 Dec 2010
Switch, faulty
RT ENG FUEL FILTER MSG, FLIGHT DIVERTED. IAW CREW AFTER TAKEOFF FROM SNA, NR2 ENG FUEL FILTER ADVISORY AND STATUS MSG. ALL OTHER INDICATIONS AND ENGINE IS…
- 1 Dec 2010
Adc, failed
LOSS INSTRUMENTS, RTFL. FOUND STATIC LINE LOOSE ON RT AIR DATA COMPUTER. MCDP LAST FLIGHT FAULTS CONFIRMED FAULT. REPLACED RT AIR DATA COMPUTER IAW MM.…
- 26 Aug 2010
Light, inoperative
DOOR 3 RT EMERGENCY EXIT LIGHT INOP EXT. RELAMPED, OPS CHECK GOOD.
- 14 Jun 2010
Relay, failed
ACFT LOST PRESSURIZATION, FLT DIVERTED. REPLACED PRSOV, RT EICAS BLEED CONFIG CARD M10312, RELAYS K10646, K10436, K10204, K10206 & K10281. ALL NO HELP,…
- 19 Apr 2010
Skin, dented
RT HORIZONTAL STAB LOWER SKIN DENTED. DENT ON LOWER SKIN 41.5" OTBD OF FUSELAGE AND 12" AFT OF L/E. DENTS ARE BETWEEN AUX SPAR AND FRONT SPAR. MOST FWD DENT…
- 26 Jan 2010
Bearing, damaged
R MED NR 4 RT BODY TORQUE TUBE BEARING BROKEN. PART OF BEARING STUCK IN CAM PLATE, PART OF BEARING STUCK ON BODY TORQUE TUBE. (LOWER MOST BEARING) CHECKED MED…
- 17 Jan 2010
Bottle, reads low
DOOR 1L EMERGENCY ASSIST BOTTLE NO PRESSURE. R & R DOOR ASSIST BOTTLE. VERIFIED DOOR 1L SLIDE PACK DISCHARGE SAFETY PIN WAS REMOVED AND STOWED.
- 1 Jun 2009
O-Ring, leaking
LOW PSI. LEAKING AT FILL VALVE. O-RING REMOVED & REPLACED. REFILLED CYLINDER.
- 8 May 2009
Slide, unserviceable
LOW BOTTLE PRESSURE. PERFORMED LEAK TEST. COULD NOT FIND A LEAK. DISCHARGED THE BOTTLE AND VALVE WILL BE FULLY DISASSEMBLED AND REWORKED.
- 28 Apr 2009
Bottle, faulty
FOUND DOOR ASSIST BOTTLE FOR DOOR 1R LOW. REPLACED DOOR 1R ASSIST BOTTLE.
- 24 Feb 2009
Battery, discharged
EMERGENCY FLASHLIGHT DOOR 2 RIGHT DOES NOT FLASH TEST. REPLACED BATTERY.
- 13 Oct 2008
Light, inoperative
DOOR NR 2 LT AND RT EMERGENCY EXIT LIGHT INOP (EXT). LAMPS INOP. RELAMPED, OPS NORMAL.
- 13 Oct 2008
Light, inoperative
DOOR 4 RT EMERGENCY EXIT LIGHT INOP (EXT). LAMPS INOP. RELAMPED EMERGENCY LIGHT, SYS IS NORMAL.
- 19 Aug 2008
Lamp, inoperative
EXTERIOR EMERGENCY LIGHT INOP AT DOOR 3R.
- 19 Aug 2008
Lamp, inoperative
EXTERIOR EMERGENCY LIGHT INOP AT DOOR 1L. RELAMPED DOOR 1L EMER LIGHT. OPS CHECKED NORMAL.
- 13 May 2008
Light, inoperative
EXTERIOR EMERGENCY LIGHT AT DOOR 2L INOP. LAMP INOP. RELAMPED LIGHT AT DOOR 2L.
- 15 Apr 2008
Light, missing
EMERGENCY EXIT LIGHT STRIP MISSING AT 34C. FOUND MISSING STRIP AND RESECURED IT. OPS TESTED OK.
- 29 Jul 2007
Light, unsecure
EMERGENCY LIGHT STRIP AT ROW 13-14 ON FLOOR NOT ATTACHED. RESECURED EMERGENCY EQUIPMENT LIGHT COVER.
- 8 Jun 2007
Strip, out of position
EMERGENCY LIGHT STRIP IS OFF THE FLOOR ABOUT TWO INCHES AT 12ABC & 13ABC. [06-22-07] FOUND EEL LIGHT STRIP SLIGHTLY DETACHED (TAPE DEGENERATED) AT ROW 13.…
- 23 May 2007
Battery Pack, inoperative
THE FOLLOWING EMERGENCY LIGHTS ARE INOP: SLIDE LIGHT DOOR 2L, EXTERIOR AFT OF WING RIGHT SIDE, EEL LIGHTS ROWS 23-30, EXIT SIGN ROW 29, AISLE LIGHTS ROWS 19,…
- 14 Feb 2007
Lamp, inoperative
EMERGENCY SLIDE LIGHT INOP AT DOORS 1R & 4R. RELAMPED NR 767 LAMP
- 2 Jan 2007
Light, inoperative
DOOR 2L SLIDE ARMED LIGHT WILL NOT ILLUMINATE. REPLACED LAMP.
- 27 Apr 2006
Smoke, detected
FOUND SMOKE REPORTED IN CABIN. RECIRCULATING FAN MESSAGE. WIRE BUNDLE W4104 FOR THE RT SIDE CABIN AIR RECIRCULATION FAN SHORTED ON ADJACENT SUPPORT BRACKET.…
- 18 Sep 2004
Structure, damaged
LT EXTERNAL FUSELAGE RIVET HOLE AT STA 520 AND STR 19L HAS EGG SHAPED HOLE. CUTOUT DAMAGE AND INSTALLED STRUCTURAL FILLER AND DOUBLER REPAIR.
- 17 Sep 2004
Frame, dented
FWD PIT FRAME DENTED AT BS 580 STR 23L. INSTALLED J-ANGLE REPAIR.
- 17 Sep 2004
Floorbeam, corroded
CABIN FLOORBEAM CAP IS CORRODED AT BS 365 FROM RBL 28 TO RBL 42. TYPICAL CORROSION FOUND ON EXISTING STRAP REPAIR. STRAP REPAIR WAS REMOVED, CORROSION…
- 17 Sep 2004
Shear Tie, corroded
AFT PIT STA 1400, FWD SHEAR TIE IS CORRODED BETWEEN STR 27L AND 28L. FABRICATED & INSTALLED NEW SHEAR TIE.
- 17 Sep 2004
Support Angle, corroded
MAIN CABIN STA 1681 FRAME SUPPORT ANGLE CORRODED AT STR 17R AT CREASE. SUPPLEMENTAL DATA UPDATE CORRODED SUPPORT ANGLE WAS FABRICATED AND REPLACED.
- 17 Sep 2004
Frame, dented
FWD PIT FRAME AT BS 520 AND STR 24L IS DENTED ON IB FLANGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED FRAME DOUBLER ANGLE.
- 17 Sep 2004
Frame, dented
AFT PIT FRAME DENTED AT BS 1460 AND STR 26L, ON IB FLANGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED FRAME DOUBLER ANGLE.
- 17 Sep 2004
Frame, dented
FWD PIT MAIN FRAME AT BS 540, BETWEEN STR 24L- STR 25L, DENTED ON IB FLANGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED A DOUBLER REPAIR…
- 17 Sep 2004
Tear Strap, corroded
BS 1400 STR 27L-28L TEAR STRAP AND SHEAR TIE CORRODED.
- 14 Sep 2004
Frame, dented
AFT PIT FRAME AT BS 1440 IS DENTED BETWEEN STRINGERS 25L AND 26L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED REINFORCING ANGLE REPAIR.
- 13 Sep 2004
Frame, dented
AFT PIT MAIN FRAME AT BS 1420, STR 26L IS DENTED. INSTALLED REINFORCING ANGLE REPAIR.
- 11 Sep 2004
Floorbeam, corroded
MAIN CABIN STA 1641 AND RBL 26 TO CENTER LINE, PREVIOUS FLOORBEAM REPAIR CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND…
- 11 Sep 2004
Frame, dented
AFT PIT FRAME STA 1480 IS DENTED BETWEEN STR 25L AND 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.
- 11 Sep 2004
Frame, dented
AFT PIT FRAME DENTED STA 1540 AT STR 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.
- 11 Sep 2004
Frame, dented
AFT PIT MAIN FRAME STA 1400, STR 25L TO 26L DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.
- 11 Sep 2004
Beam, unknown
LT AND RT WHEEL WELL CANTED BEAMS. INSTALLED DOUBLER TO MLG CANTED BEAMS.
- 9 Sep 2004
Shear Tie, corroded
AFT PIT STA 1600 BETWEEN STR 28R AND 29R, SHEAR TIE IS CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SHEAR TIE.
- 9 Sep 2004
Floorbeam, corroded
CABIN FLOORBEAM CAP CORRODED BS 310, RBL 44. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED L ANGLE DOUBLER.
- 7 Mar 2004
Idg, failed
LEFT GENERATOR CONTROL OFF LIGHT AND EICAS MESSAGE CAME ON. THREE ATTEMPTS TO START THE APU WERE UNSUCCESSFUL. REPLACED THE LEFT IDG.ONE PISTON IN THE…
- 9 Dec 2003
Skin, dented
SKIN DENTED AT STA 732, STRINGER 28R. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 10 Oct 2003
Valve, defective
FUEL IMBALANCE BETWEEN LT AND RT TANKS. THE CAUSE OF THE FUEL IMBALANCE CONDITION WAS DUE TO A DEFECTIVE CROSS-FEED VALVE BODY ASSY. SHOP FINDINGS REVEALED…
- 30 May 2003
Lamp, burned out
LEFT AFT OFF-WING EMERGENCY SLIDE LIGHT, AFT OF AFT OVERWING HATCH IS INOPERATIVE. RELAMPED LIGHT.
- 20 May 2003
Bottle, discharged
DOOR 1R ASST BOTTLE FOUND WITH NO PRESSURE. BOTTLE PRESSURE EVACUATED DUE TO RUPTURED BURST DISC ON ASSIST BOTTLE. DOOR ASSIST BOTTLE REPLACED. NO ADDITIONAL…
- 6 Dec 2000
Fan, failed
'EQUIPMENT OVERHEAT' EICAS MESSAGE FOLLOWED BY ADI BACKGROUND TURNING BLACK. SUPPLEMENTAL DATA UPDATE THE AIRCRAFT EXPERIENCED A LEFT RECIRCULATION FAN…
- 22 Jul 2000
Access Door, damaged
TAIL CONE AND AUXILIARY POWER UNIT DOOR ON LEFT SIDE, AFT OF HORIZONTAL STABILIZER, IS DAMAGED. *S/D* MAJOR REPAIR ACCOMPLISHED WHERE THE FOLLOWING PARTS WERE…
- 30 Sep 1996
Fuel Cap, failed
DURING FLIGHT, LEFT OVERWING FUEL CAP DEVELOPED A LEAK. AIRCRAFT DIVERTED TO DEN. REPLACED FUEL CAP, OPERATION CHECKS NORMAL.
- 29 Jan 1996
Strip, loose
EMERGENCY EXIT LIGHT STRIP DAMAGED AND LOOSE. SECURED THE EMERGENCY EXIT LIGHT STRIP TRACK TO FLOOR USING TAPE AND LEAVING THE EMERGENCY EXIT LIGHT STRIP…
- 17 Jan 1996
Light, inoperative