- 23 Oct 2014
Brake, lack of lube
RECEIVED TE FLAP DISAGREE MSG WHEN FLAP HANDLE FROM 20 TO 25. FOUND TRANSMISSION OVLD INDICATOR TRIP 1, 5 & 8. RESET TRIP OVLD INDICATOR & LUBED FLAP TRANS…
- 10 Jun 2014
Engine, overtemp
CREW REPORTS NR 1 ENG SN 727142, ON CLIMB OUT EGT PEAK TO 651, ECM T OFF SNAP SHOT SHOWS EGT PEAK 651, OAT 41.0C=106F AT LAS. PERFORMED OVER TEMPERATURE…
- 22 May 2014
Light, inoperative
RIGHT FWD OVERWING EXIT DOOR, FWD EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED OVERWING EXIT DOOR LIGHT IAW MM33-51-01. OPERATIONS CHECKED OK.
- 15 Feb 2014
Light, inoperative
EMERGENCY EXIT LIGHT STRIP FROM ROW 30 TO 32 ILLUMINATION INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT STRIP & POWER INVERTER, OPERATIONS CHECKED OK.
- 10 Feb 2014
Light, broken
EMERGENCY ESCAPE PATH LIGHTING STRIP 32C BROKEN. REPLACED POWER FEED CABLE AT SEAT 34 ABC. REPLACED CLEAR COVER FROM SEAT 31 AFT TO END OF EMERGENCY EXIT…
- 5 Feb 2014
Light, damaged
EMERGENCY EXIT LIGHT STRIP DAMAGED AT ROW 31. REPLACED EMERGENCY EXIT LIGHT AT SEAT 31, OPERATIONS CHECKED NORMAL, EMERGENCY EXIT LIGHT LENS SECURED AT ROW 31.
- 19 Dec 2013
Switch, defective
PREFLIGHT CHECK OF CTR FUEL PUMPS FAILED. CTR PUMP LIGHTS DO NOT ILLUMINATE AFTER 10 SEC. TROUBLE SHOT IAW WDM 28-21-11. R & R S346 FUEL PANEL DOOR OPEN…
- 9 Dec 2013
Unknown, faulty
DOOR 4L ARMED LIGHT IS ON BUT DOOR IS DISARMED. SLIDE INDICATOR OVER DOOR 4L IS DIMLY LIT WHEN DISARMED. VERIFIED GIRT BAR OPERATION NORMAL WHEN ARMING &…
- 11 Nov 2013
Actuator, failed
AUTOPILOT ADJUSTMENT TEST FAILS CTR RUDDER SERVO TEST. REPLACED CTR RUDDER ACTUATOR. ACCOMPLISHED TESTS REQUIRED FOR ACTUATOR REPLACEMENT.
- 22 Oct 2013
Smoke Goggles, faulty
CAP NEEDS A NEW SMOKE GOGGLE. REPLACED WITH NEW SMOKE GOGGLE
- 12 Oct 2013
Headset, faulty
CAPT HEADSET MIC IS HOT IN FLT INPH & SERV INPH, REPEAT WRITEUP. REPLACED CAPTS HEADSET, OPERATIONS CHECKED GOOD.
- 9 Oct 2013
Feeder Cable, damaged
EMERGENCY EXIT LIGHT STRIPS INOPERATIVE FROM ROW 8 THRU ROW 12. THE IN TRACK FEEDER CABLE IS OPEN. IN ADDITION, AT LEAST 2 ILLUMINATED STRIPS ARE INOPERATIVE.…
- 4 Oct 2013
Guide Vane, cracked
NR 2 ENG FOUND CRACKED GUIDE VANE ON WALK AROUND INSPECTION. ONE EACH ALUMINUM EXIT GUIDE VANE REMOVED FROM THE ONE O'CLOCK POSITION, ENG SN 727114. INSTALL…
- 17 Jul 2013
Skin, torn
NR 2 ENGINE CORE COWL OTBD SKIN HAS A TEAR MEASURING 2.75" LONG AND .5 WIDE. REPLACED NR 2 ENGINE OTBD CORE COWL IAW AMM.
- 6 Jul 2013
Lamp, inoperative
L4 DOOR SLIDE LIGHT INOPERATIVE. VERIFIED GIRT BAR ENGAGED. REPLACED LAMP LIGHT, ARM LIGHT CHECKED OK.
- 12 Jun 2013
Cover, unsecure
LIGHTING STRIP AT 34F HAS FALLEN OFF. REPLACED EMERGENCY LIGHT COVER FROM SEAT 24 TO 32.
- 12 Jun 2013
Feeder Cable, damaged
EMERGENCY LIGHT FROM ROWS 28 THROUGH 32 INOPERATIVE. REPLACED FEEDER CABLE FROM SEAT 32. ALL EMERGENCY LIGHTS CHECKED GOOD.
- 9 Apr 2013
Battery, faulty
STATUS MSG MAIN BATTERY CHAGER. REPLACED BATTERY AND CHARGER, ALL CHECKS OK NOW. SYSTEM REMOVED AND REPLACED PER MM.
- 1 Apr 2013
Cap, missing
EMERGENCY EXIT LIGHT END CAP MISSING AT 8C AND 40C. REPLACED END CAPS.
- 1 Feb 2013
Controller, failed
WINDOW EICAS MESSAGE DISPLAYED. INOPERATIVE MESSAGE LIGHT DID NOT EXTINGISH WHEN SWITCH WAS RECYCLED TO OFF THEN ON. REPLACED WINDOW HEAT CONTROLLER.
- 10 Nov 2012
Arm, out of adjust
F/O SLIDING WINDOW HANDLE BINDING. ADJUSTED LOWER LINK ARM.
- 10 Oct 2012
Engine, making metal
REPLACE NR 1 ENGINE REF LM4718 DUE TO EXCESSIVE METAL FOUND IN OIL FILTER AND CHP REF MM 71-00-02 CONFIG 1. REPLACE NR 1 ENGINE REF LM4718 DUE TO EXCESSIVE…
- 9 Oct 2012
Seal, loose
DOOR 4R, LOWER AFT SLIDE COVER HAS LOOSE SEAL. SEAL GOES BETWEEN SLIDE COVER AND FLOOR. THIS IS A DUST SEAL AT BOTTOM OF DOOR 4R INNER DOOR SLIDE COVER.…
- 18 Sep 2012
Fan, inoperative
HAVE EQUIPMENT OVERHEAT, FORWARD EQUIPMENT FAN INOP. ALSO FOUND THAT THE LEFT RECIRC FAN INOP AND CAUSING ABOVE MESSAGE. SUSPECT FAN BAD. REPLACED RELAYS…
- 16 Sep 2012
Windshield, delaminated
1ST OFFICER'S WINDSHIELD'S VISIBILITY IS AFFECTED BY DEFECTS, REPLACE FIRST AVAILABLE. DELAMINATED RIGHT SIDE AND ALONG BOTTOM. REPLACED NR 1 RIGHT WINDSHIELD…
- 13 Aug 2012
Vane, bent
RT ENGINE EXIT GUIDE VANE BENT, AT ONE O'CLOCK LOOKING FWD. REMOVED DAMAGED FAN EXHAUST GUIDE VAN, LOWER RUBBER BASE SEAL AND VANE SEGMENT. REMOVED DAMAGED.…
- 10 Aug 2012
Control Panel, faulty
MODE CONTROL PANEL NEEDS RESET. REPLACED MODE CONTROL PANEL PER MM. PERFORMED CATIII CK PER MM. SYSTEM TESTED OKAY.
- 17 Jul 2012
Roller, worn
ACFT VIBRATION, DROPPED FLAPS. LEFT INBD AFT FLAP HAS EXCESSIVE PLAY WHEN FULL EXTENDED. AFTER FURTHER INSPECTION SUSPECT TRAILING EDGE FLAP CARRIAGE ROLLERS…
- 10 Jul 2012
Nut, cracked
NR 3 AFT TIRE: ONE TIE BOLT NUT IS CRACKED. REPLACED TIRE.
- 9 Jul 2012
Service Panel, loose
DURING DESCENT, VERY NOTICEABLE VIBRATION IN FLOOR FROM ROW 20 TO DOORS 2R&L. FOUND HYD SERVICE PANEL LEADING EDGE LATCHES OUT OF ADJUSTMENT. PANEL VERY…
- 27 May 2012
Bearing, worn
VIBRATION AND HUM IN FLIGHT AT ROWS 10, 11, AND 21. ROWS 11, 22 AND 28 THE NOISE SEEMS TO BE GETTING LOUDER. EARLIER IN DESCENT THE NOISE WAS LESS BUT…
- 13 Feb 2012
Bearing, lack of lube
DOOR 2L HARD TO OPEN. LUBED TORQUE TUBE BEARING, OPERATED DOOR SEVERAL TIMES, OPS CHECKED GOOD.
- 3 Jan 2012
Lamp, inoperative
L1 DOOR SLIDE ARMED LIGHT INOPERATIVE. RELAMPED, OP CHECKED GOOD.
- 18 Jul 2011
Pca, loose
FOUND LT ELEVATOR MIDDLE PCA REACTION LINK AND PCA ACTUATION ROD EXTREMELY LOOSE. FOUND LT ELEVATOR MIDDLE PCA REACTION LINK AND PCA ACTUATION ROD EXTREMELY…
- 7 Jun 2011
Unknown, malfunctioned
NOISE IN COCKPIT VERY LOUD ON DESCENT REGARDLESS OF RECIRC FAN BEING ON OR OFF. COMPLIED WITH MEL, ACP STEP 6 OFF. THE FLOW AND VELOCITY FAILED. FLOW WAS 437…
- 8 Apr 2011
Light, unsecure
CREW REPORT: EMERGENCY EXIT FLOOR LIGHTING LOOSE AT 13C. SECURED LIGHT STRIP.
- 7 Apr 2011
Windshield, delaminated
1ST OFFICER'S FIXED SIDE-AFT WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS. REPLACE FIRST AVAILABLE. CREW COMMENTS: WINDOW R3 HAS 2 DELAM BUBBLES SIZE OF A…
- 24 Mar 2011
Sensor, inoperative
F/A REPORTED DOOR 3R SLIDE ARMED LIGHT INOP. VERIFIED GIRT BAR ENGAGEMENT CORRECT AND DOOR ARMS CORRECTLY. ONLY LIGHT INOP. NEEDS LIGHT SOCKET ASSY, (PCN…
- 13 Mar 2011
Seal, damaged
DOOR 4L DOOR SLIDE REMOVED FOR SEAL REPAIR. SAME DOOR SLIDE RE-INSTALLED REF AMM.
- 4 Mar 2011
Floorbeam, corroded
CORROSION ON TOP OF FLOORBEAM AT STA 324 RBL 51- RBL 55. ACCOMPLISHED REPAIR OF FLOOR BEAM IAW PD57-53-093 AND EVA 80627.
- 4 Mar 2011
Pressure Panel, corroded
CORROSION ON AFT PRESSURE DECK LEADING EDGE AT BS 1681 RBL 3 THRU RBL 34. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND CUT OUT DAMAGED AREA. FABRICATED…
- 25 Feb 2011
Smoke Detector, faulty
EQUIPMENT COOL SMOKE DETECTOR - REPLACED EQUIP COOL SMOKE DETECTOR ON TASKCARD.
- 21 Feb 2011
Floorbeam, corroded
CORROSION ON TOP OF FLOORBEAM AT STA 1640 RBL 8 - RBL 50. ACCOMPLISHED COA SMC002 ON TASKCARD 2487N00201.
- 5 Jan 2011
Cap, missing
EMERGENCY ESCAPE LIGHTING STRIP END CAP MISSING AT 6B. REPLACED EMERGENCY LIGHT STRIP BLACK END CAP. ALL EMERGENCY LIGHTS WORKED NORMAL.
- 9 Oct 2010
Battery, discharged
CABIN EMERGENCY LIGHTS INOP ON O/H BIN BULL NOSE. 1AB, 2CD, 6AB, 11AB, 20DEF, 21ABC, 23DEF, LT OVERWING EXIT. PUSHED CB AND CHARGED BATTERY. OPS CHECK GOOD.
- 2 Sep 2010
Wire, burned
FOUND FWD CLOSET LIGHT SWITCH S10578 DAMAGED. OPENING UP FWD CLOSET FOR ACCESS TO BURNED WIRES. FOUND 5VAC WITH CB FOR CLOSET LIGHT PULLED. CHECKING BETWEEN…
- 27 Jul 2010
Unknown, odor
ACRID OIL SMELL IN CABIN, FLT DIVERTED. FERRIED IN FOR APU CHANGE OIL SMELL IN CABIN AND PACK BURNOUTS. WILL REPLACE APU AND ACCOMPLISH LM ITEMS. REPLACED APU…
- 25 Jul 2010
Unknown, odor
SMOKE IN CABIN, FLIGHT DIVERTED. APU PNEUMATICS HAS STRONG OIL ODOR IN FLIGHT DECK AND CABIN. FOUND APU OIL SMELL VERY NOTICEABLE WITH RT PACK ON. ISOLATED RT…
- 27 Apr 2010
Chiller, faulty
CREW REPORTS ELECTRICAL ODOR IN CABIN AROUND ROWS 28-34. INVESTIGATE AND REPORT FINDINGS TO SAMC. CHECKED ALL CABIN, GALLEY AND LAV LIGHTS. CHECKED ALL GALLEY…
- 2 Mar 2010
Lamp, inoperative
EXTERIOR FUSE EMERGENCY EXIT LIGHTS INOP AT 1 RT MED 2 LT MED AND RT OVERWING EXIT FWD POSITIONS. REPLACED LAMPS P/N 767, OPS GOOD
- 2 Jan 2010
Water Heater, overheated
FWD AFT LAV SMOKE DETECTOR WENT OFF (REPEAT). HOT IRON TYPE ODOR EMANATING FROM THAT LAV. UPDATE-CREW TURNED OFF WATER HEATER AND RAN ALL HOT WATER OUT OF…
- 30 Dec 2009
Smoke Detector, faulty
FWD AFT LAV SMOKE DET ALARMING AND WILL NOT RESET. REPLACED FWD AFT LAV SMOKE DETECTOR, OPS CHECKS OK.
- 27 Dec 2009
Light, inoperative
EXIT LIGHT AT DOOR 1R BY THE LINEN DISPOSAL COMP IS INOP. REPLACED EXIT LIGHT, OPS CHECKS GOOD.
- 27 Dec 2009
Lamp, inoperative
EXIT LIGHT AT DOOR 1R BY THE LINEN DISPOSAL COMP. IS IN-OP. REPLACED EXIT LIGHT, OPS CHECKS GOOD.
- 21 Oct 2009
Oxygen Mask, leaking
CAPTAIN'S O2 MASK LEAKS. REPLACED CAPTAIN'S O2 MASK. OP TEST OKAY.
- 21 Oct 2009
Smoke Goggles, damaged
ALL FLIGHT DECK SMOKE GOGGLES HAVE SCRATCHED LENS. REPLACED SMOKE GOGGLES, 3EA.
- 25 Apr 2009
Wire, damaged
RIGHT WING L/E, OUTBOARD OF NR 2 ENG PYLON WIRE DAMAGED. REPLACED WIRE W4026-4501 PER BSPMS 20-10-13, 20-35-19, 20-10-15, AND CHECKED GOOD.
- 20 Apr 2009
Battery Pack, discharged
RIGHT AFT OVERWING EMERGENCY LIGHT INOP. REPLACED BATTERY PACK AT M10568 AND OPS CHECK GOOD.
- 7 Mar 2009
Light, inoperative
NR 2 RT MED EXTERIOR EMERGENCY EXIT PATH LIGHT INOP. REPLACED LAMP, OPS GOOD. P/N BULB 767.
- 21 Nov 2008
Oxygen Mask, defective
PILOTS O2 MASK HAS DEFECTIVE AIRFLOW. REPLACED MASK & OP CHECKS OK.
- 22 Oct 2008
Oxygen Mask, leaking
CAPT O2 MASK HAS CONSTANT FLOW WHEN IN USE. FOUND MASK LEAKING. REPLACED CAPT OXYGEN MASK. LEAK & OPS TEST OKAY.
- 24 Jun 2008
Light, inoperative
DOOR 4 LEFT OUTSIDE EMERGENCY LIGHT INOP. *S/D* LAMP INOP. RELAMPED LIGHT BULB AND OPS CHECKED GOOD.
- 27 Apr 2008
Light, inoperative
EXT EMERGENCY EXIT LIGHT INOP DOOR 2R, RELAMPED.
- 10 Mar 2008
Flap System, malfunctioned
TRAILING EDGE FLAP DISAGREE BETWEEN 25 AND 30. PERFORMED SEVERAL FLAP DEPLOYMENTS, NO DISAGREE NOTED AT ANY SETTING OR BETWEEN SETTINGS, UNABLE TO DUPLICATE…
- 22 Feb 2008
Light, loose
NR 2 CARGO FIRE BOTTLE DISCHARGE LIGHT INOP. INDICATOR LIGHT LOOSE. SECURED LIGHT ASSY, GROUND CHECKS OK.
- 20 Feb 2008
Actuator, faulty
RUDDER TRIM FAILED TO TRIM IN EITHER DIRECTION. CREW COMMENTS: RUDDER TRIM INTERMITTENT. RUDDER TRIM ACTUATOR FAILURE, TRANSMITTER ISSUE. REPLACED RUDDER TRIM…
- 8 Jan 2008
O-Ring, leaking
LOW BOTTLE. FOUND LEAK AT THE CENTER O-RING OF THE TANK. REPLACED O-RING ON CENTER SHAFT.
- 21 Dec 2007
Slide, low pressure
DOOR 4L SLIDE PRESSURE IS ON LOW END OF GREEN BAND. REPLACED SLIDE ASSY.
- 14 Sep 2007
Strap, broken
NR 1 LEFT MED SLIDE GIRT BAR STRAP BROKEN RIVETS. 10-9-07 REPLACED LT MAIN ENTRY DOOR SLIDE.
- 25 Aug 2007
Landing Gear, malfunctioned
GEAR DOWN AND LANDING GEAR ALTN EXTEND C/B (F5) ON P6 PANEL TRIPPED.
- 24 Jul 2007
Power Supply, inoperative
INTERIOR OVERWING EEL LIGHTS INOPERATIVE, ONE ON EACH SIDE OF A-C. REPLACED EEL PWR SUPPLY. OP CK GOOD.
- 22 May 2007
Unknown, unknown
DURING FLIGHT CENTER FUEL TANK QTY ROSE FROM 0 TO 1300 AND RIGHT WING DOWN 2K LESS THAN LEFT WING. [06-20-07] AT DISPATCH TIME, FUELER COULD NOT OPEN RIGHT…
- 4 Dec 2004
Skin, dented
TWO DENTS LT FUSELAGE AT STA 606, STR 15L AND 16L. REMOVED 4 EA EXISTING REPAIRS AND INSTALLED DOUBLER REPAIR PER EVA IMC-30171.
- 19 Aug 2004
Frame, dented
FRAME AT STATION 1400 DENTED ABOVE STR 25L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 19 Aug 2004
Frame, dented
FRAME AT STA 1420 IS DENTED BETWEEN STR 25-26L. MAJOR REPAIR ACCOMPLISHED. FRAME REPAIR DOUBLER INSTALLED.
- 19 Aug 2004
Frame, dented
FRAME AT STA 1500 DENTED ABOVE STR 25L. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED ANGLE REPAIR.
- 17 Aug 2004
Shear Web, corroded
AFT CABIN SHEAR WEB HAS AREA OF CORROSION AT APPROX BS 1681 THRU 1699 RBL 44 THRU 54. *S/D* MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW WEB.
- 17 Aug 2004
Floorbeam, corroded
AFT CABIN FLOORBEAM AT BS 1640 IS CORRODED RBL 18 THRU 58. *S/D* MAJOR REPAIR ACCOMPLISHED. FABRICATED NEW T-CAP AND REPAIR STRAPS.
- 17 Aug 2004
Web, cracked
FLIGHT DECK FLOOR WEB CRACKED ON VERTICAL LEG AT FIRST FASTENER AFT OF STA 199 BULKHEAD ON RT SIDE OF AIRCRAFT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND…
- 7 Aug 2004
Floor Support, corroded
CABIN STATION 365, CL TO RBL 15 FLOOR SUPPORT HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP AND L-ANGLE REPAIR.
- 7 Aug 2004
Floorbeam, corroded
AFT CABIN FLOORBEAM AT STA 1661, RBL 54 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.
- 7 Aug 2004
Floorbeam, corroded
MAIN CABIN AT STA 365, RBL 45 TO RBL 60, FLOORBEAM HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.
- 6 Aug 2004
Skin, damaged
EXTERNAL FUSELAGE SKIN HAS 2 LIGHTNING STRIKES JUST BELOW FWD CARGO DOOR STA 582 AND 529 AT STR 27R, DEPTH WAS MEASURED TO BE .100. INSTALLED DOUBLER REPAIR.
- 31 May 2004
Apu, malfunctioned
APU ON AT GATE FOR 3 MIN. PUT BOTH PACKS ON NOTICED BLUE-OIL SMOKE IN COCKPIT & CABIN. REPLACED APU. STAT-O-SEALS FAILED IN THE DRIVEN COMPRESSOR MODULE.…
- 4 Dec 2003
Skin, dented
TWO DENTS LT FUSELAGE AT STA 606, STR 15L AND 16L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 4 Dec 2003
Web, corroded
AFT PIT CARGO DOOR CUTOUT THRESHOLD SILL WEB CORRODED UNDER THRESHOLD PLATE. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED & INSTALLED WEB REPAIR.
- 2 Dec 2003
Web, corroded
AFT PIT CARGO DOOR CUTOUT THRESHOLD SILL WEB CORRODED UNDER THRESHOLD PLATE. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED & INSTALLED WEB REPAIR.
- 4 Jun 2002
Skin, dented
DENT ON FRAME-SKIN SPLICE AT STA 1620 FWD OF NR 3L ENTRY DOOR AT FLOOR LEVEL. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR ACCOMPLISHED.
- 4 May 2001
Stringer, damaged
FUSELAGE SKIN AND STRINGER DAMAGED STA 780, STR 16 LT. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRINGER SPLICE AND DOUBLER.
- 16 Jul 1998
Idg, failed
CREW DIVERTED TO DEN DUE TO LOSS OF NUMBER 2 GENERATOR. *S/D* THE IDG STATOR ASSEMBLY HAD SHIFTED WHICH CAUSED A CRACK IN A CONTROL CURRENT TRANSFORMER…
- 8 Oct 1997
Tube, failed
DURING THE SHOP OVERHAUL OF AN EVACUATION SLIDE REMOVED FOR TIME EXPIRATION IT FAILED THE PROOF TEST. THERE WAS A SEAM SEPARATION OF OVER 8 FEET ON THE LEFT…
- 28 Nov 1995
Battery, discharged
EMERGENCY EXIT GREEN LIGHTS INOP AT LEFT AND RIGHT REAR SERVICE DOORS. WHITE EMERGENCY EXIT LIGHT INOP AT LEFT REAR SERVICE DOOR. REPLACED BATTERY, CHECKS OK.