service difficulty reports
73 reports
- 19 Jul 2016
Lavatory, underserviced
DURING CLIMB FLIGHT ATTDENDANTS REPORTED ALL LAVATORIES INOPERATIVE. EMERGENCY DECLARED. LANDING UNEVENTFUL. LAVATORIES SERVICED. SYSTEM CHECKED NORMAL.
- 3 Jul 2016
Switch, out of adjust
DURING TAKE OFF ROLL, THE AUTO BRAKE HORN ACTIVATED. TAKE OFF WAS REJECTED. MAINTENANCE ADJUSTED THE REJECTED TAKE OFF SWITCHES IAW AMM 27-60-00. OPS CHECKED…
- 9 Jun 2016
Generator, out of adjust
AIRCRAFT WAS GROUNDED. DURING CRUISE, CREW REPORTED A CHATTERING SOUND IN COCKPIT, ACCOMPANIED BY NUMEROUS AUDIBLE AND VISUAL WARNINGS. APU WAS STARTED, LT…
- 27 Mar 2016
Transformer, odor
AIRCRAFT WAS GNDED. DURING FLIGHT AN ACRID & ELEC ODOR WAS REPORTED IN THE MID CABIN AREA. FOUND READING LIGHT TRANSFORMER T1-90 HOT & EMITTING ODOR. R & R…
- 9 Oct 2015
Angle, cracked
CORROSION ON CASTING AFT SIDE OF 1155 FRAME AT INBD DOOR CUT OUT OF AFT CARGO DOOR. REMOVED CORROSION & FOUND CRACK IN ANGLE. R & R ANGLE IAW AARD 51-00-05-1,…
- 9 Oct 2015
Skin, cracked
CRACK IN FUSELAGE SKIN AT STATION 1437, LONGERON 3L. INSTALLED DOUBLER REPAIR IAW SRM 53-04-00 FIGURE 27.
- 31 Jul 2015
Battery Pack, discharged
EMERGENCY LIGHTS WILL NOT TEST AT ZONE AB5-1, AB5-3 & AB5-4. R & R BATTERY PACK AT ZONE AB5-4. SEE ALSO AALA20150803006 & AALA20150803006.
- 31 Jul 2015
Battery Pack, discharged
EMERGENCY LIGHTS WILL NOT TEST AT ZONE AB5-1, AB5-3 & AB5-4. R & R BATTERY PACK AT ZONE AB5-1. SEE ALSO AALA20150801003 & AALA20150803007.
- 31 Jul 2015
Battery Pack, discharged
EMERGENCY LIGHTS WILL NOT TEST AT ZONE AB5-1, AB5-3 & AB5-4. R & R BATTERY PACK AT ZONE AB5-3. SEE ALSO AALA20150801003 & AALA20150803006.
- 14 Jul 2015
Lock Sensor, faulty
AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB WITH GEAR UP, NLG SHOWED RED UNSAFE. ON GEAR EXTENSION MLG SHOWED GREEN &…
- 21 Apr 2014
Stop Fitting, cracked
MID CARGO DOOR STOP PAD CASTING CRACKED. R & R STOP PAD CASTING IAW AARD 51-00-05-1.
- 10 Apr 2014
Rib, cracked
LEFT HAND WING NR 4 SLAT TRACK LE INBD SUPPORT RIB CRACKED. REMOVED CRACK & INSTALLED WASHER SHIM & DOUBLER IAW EA MD80-57-034407.
- 10 Apr 2014
Rib, cracked
RIGHT HAND WING NR 4 SLAT TRACK LE INBD SUPPORT RIB CRACKED. REMOVED CRACK & INSTALLED WASHER SHIM & DOUBLER IAW EA MD80-57-034407.
- 5 Nov 2013
Battery Pack, discharged
EMERGENCY LIGHTS AT FWD AREA NEAR CLASS DIVIDER IN CEILING ARE INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY PACK AT SEAT ROW 8. OPERATIONS CHECKED NORMAL.
- 31 Oct 2013
Selector Panel, faulty
MSY LOSS OF CABIN PRESSURE. CABIN O2 MASKS WERE DEPLOYED. EMERGENCY DECLARED FLIGHT LANDED MSY WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. AIRCRAFT…
- 3 Sep 2013
Slide, damaged
DURING PREFLIGHT, FOUND GIRT BAR AT SERVICE DOOR OUT & PINS EXPOSED. FOUND ALL PINS PULLED OUT OF SLIDE & GIRT BAR HANGERS BENT DOWN. REPAIRED HANGERS &…
- 17 Oct 2012
Skin, cracked
FOUR CRACKS IN THE FUSELAGE SKIN AT LONGERON 22 FROM STATIONS 160 TO 200. INSTALLED DOUBLER PER EA MD80-53-009386.
- 10 Oct 2012
Cusp Web, cracked
SEVERAL CRACKS IN RIGHT CUSP SHEET BETWEEN STATIONS 1287 TO 1309. INSTALLED NEW CUSP SHEET FROM STATIONNS 1250 TO 1309 RIGHT PER AARD 51-00-05-1.
- 9 Oct 2012
Longeron, cracked
STATION 200, LONGERON 4 LEFT IS CRACKED ON BOTH HAT SECTIONS. INSTALLED NEW SECTION OF LONGERON FROM STATIONS 168 TO 228 PER AARD 51-00-05-1.
- 9 Oct 2012
Door Frame, corroded
NUT PLATE HOLES CORRODED ON DOOR JAMB WEB UNDER AFT RIGHT TIE-DOWN TRACK BETWEEN STATIONS 1212 TO 1215. INSTALLED NEW WEB AS PER AARD 51-00-5-1.
- 9 Oct 2012
Skin, cracked
CRACK IN SKIN AT STATION 1309 ABOVE LONGERON 7 LEFT. INSTALLED DOUBLER PER SRM 53-04-03 FIGURE 9.
- 9 Oct 2012
Cusp Web, corroded
LEFT CUSP CORRODED AT STATION 256 OUTBOARD OF NUMBER 1 SEAT TRACK. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 9 Oct 2012
Membrane, corroded
CORROSION ON SUBFLOOR FROM STATIONS 160 TO 200, RIGHT BUTTLINES 44 TO 57. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 9 Oct 2012
Tee Fitting, corroded
CORROSION ON CUSP TEE TAB AT RIGHT STATION 200, RIGHT BUTTLINE 55. INSTALLED TITANIUM DOUBLER PER AARD 53-20-00-14.
- 9 Oct 2012
Longeron, cracked
STATION 160 LONGERON 2 LEFT IS CRACKED ON BOTH HAT SECTIONS. INSTALLED SPLICE REPAIR PER SRM 53-02-00 FIGURE 18.
- 9 Oct 2012
Membrane, corroded
E&E COMPARTMENT HAS CORROSION IN UPPER CEILING WEBBING AT FASTENER FORWARD OF AILERON SERVO UNIT. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 9 Oct 2012
Membrane, corroded
STATION 201 LEFT BUTTLINE 8, CORRODED ON SUBFLOOR. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 9 Oct 2012
Angle, corroded
WORN SPOTS ON ANGLE AT LOWER AFT SIDE OF RIGHT STATION 1309 BULKHEAD. INSTALLED ANGLE SPLICE REPAIR PER SRM 51-70-05 FIGURE 1.
- 8 Oct 2012
Frame, cracked
THE 1485 CANT FRAME CRACKED BELOW AIRSTAIR STAIR ACTUATOR. INSTALLED SPLICE DOUBLER ON 1485 CANT FRAME RIGHT BELOW AIRSTAIR ACTUATOR PER AARD 53-10-00-33.
- 8 Oct 2012
Membrane, punctured
PUNCTURE IN FORWARD SUBFLOOR, STATION 198, LEFT BUTTLINE 24. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 8 Oct 2012
Cusp Web, corroded
STATION 201, RIGHT BUTTLINE 55 CORRODED ON SUBFLOOR. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 8 Oct 2012
Angle, corroded
RIGHT CUSP ANGLE CORRODED ON TOP SIDE FROM STATIONS 160 TO 200. INSTALLED DOUBLER PER SRM 53-05-00 FIGURE 55.
- 7 Oct 2012
Cusp Web, corroded
LEFT CUSP CORRODED AT STATIONS 240 TO 256. INSTALLED DOUBLER REPAIR PER AARD 51-00-05-1.
- 6 Oct 2012
Longeron, cracked
CABIN LONGERON INBOARD LEG IS CRACKED AT STATION 464, LONGERON 4 LEFT. REMOVED DAMAGE AND COMPLETED INSTALLATION OF LONGERON L-4 AND SPLICES FROM STATIONS 438…
- 3 Oct 2012
Web, corroded
E AND E COMPARTMENT HAS CORROSION IN UPPER CEILING WEBBING AROUND G1 GALLEY FLOOR SERVICE PAN. INSTALLED DOUBLER ON SUBFLOOR UNDER G1 GALLEY DRAIN PAN PER…
- 2 Oct 2012
Seat Track, corroded
SEAT TRACK NUMBER 4 CORROSION BLENDED OUT OF LIMITS AT STATION 879. INSTALLED SEAT TRACK PLUG PER AARD 53-20-00-10.
- 2 Oct 2012
Skin, cracked
CRACK IN SKIN AT STATION 1309 ABOVE LONGERON 7 LEFT. INSTALLED DOUBLER, FILLER AND FINGERS PER SRM 53-04-03 FIGURE 9 AND SRM 51-01-00 PARAGRAPH 4.
- 2 Oct 2012
Cusp Web, punctured
MID CARGO LEFT CUSP HAS PUNCTURE AT STATION 623. INSTALLED DOUBLER PER AARD 53-20-00-16.
- 2 Oct 2012
Cusp Web, cracked
RIGHT CUSP CRACKED FROM STATIONS 494 TO 496. INSTALLED REPAIR DOUBLER ON RIGHT CUSP PER AARD 53-20-00-16.
- 1 Oct 2012
Support Bracket, cracked
CENTER DOOR STOP SUPPORT BRACKET CRACKED INSIDE LEFT SIDE OF VAULT DOOR JAMB. INSTALLED NEW DOOR STOP MOUNT PER AARD 51-00-05-1.
- 2 Jul 2012
Battery, not seated
CEILING EMERGENCY LIGHTS FROM ROWS 12 TO 16 INOPERATIVE. RESEATED EMERGENCY BATTERY AT ROW 15DEF. OPS CHECK NORMAL.
- 2 Jul 2012
Battery, not seated
CEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30. RESEATED EMERGENCY BATTERY AT ROW 28. OPS CHECK NORMAL.
- 3 Mar 2010
Skin, cracked
WHILE ACCOMPLISHING HIGH FREQUENCY EDDY CURRENT INSPECTION OF THE FUSELAGE SKIN BETWEEN STATION 160 AND STATION 200 AT LONGERON 22LEFT CRACKS WERE FOUND.…
- 2 Mar 2010
Longeron, cracked
LONGERON 2 FOUND CRACKED AFT OF STATION 1418. REPAIRED PER AARD 53-30-00-2 FIGURE 1 SHEET 1.
- 2 Mar 2010
Longeron, cracked
LONGERON 20 CRACKED ABOVE INBOARD FLAP ACTUATOR AT STATION 993 RIGHT SIDE. INSTALLED REPAIR ANGLE ON LONGERON 20 STATION 993 PER AARD 53-10-00-18.
- 31 Dec 2009
O-Ring, leaking
INFLIGHT LAX TO AUS. FUEL LEAK AT OUTER FUEL PUMP BOOST COVER ON TOP OF RIGHT WING. LANDED PHX WITHOUT INCIDENT. REPLACED UPPER RIGHT COMPENSATOR O-RING.
- 30 Sep 2009
Slide, low pressure
AFT SERVICE DOOR SLIDE INDICATED ZERO PRESSURE ON THE SLIDE MOUNTED INDICATOR. REPLACED SLIDE.
- 19 Nov 2008
Fuel Control, inoperative
ABQ - INFLIGHT DFW-SJC - LEFT ENGINE LOST THROTTLE RESPONSE. CREW SHUT DOWN ENGINE. SINGLE ENGINE TIME 30 MINUTES. EMERGENCY DECLARED LANDED ABQ WITHOUT…
- 2 May 2008
Engine, leaking
COS INFLIGHT T656/02MAY SAN TO ORD - NUMBER TWO ENGINE COMPRESSOR STALLED. HIGH ENGINE GAS TEMPERATURE NOTED. CREW SHUT NUMBER TWO ENGINE DOWN. LANDED COS…
- 12 Jan 2007
Slide, partial inflate
SFO - RIGHT NUMBER ONE DOOR EMERGENCY SLIDE INADVERTENTLY UNSUCCESSFULLY DEPLOYED WHEN OPEN FROM OUTSIDE BY CATERING PERSONNEL. REPLACED RIGHT NUMBER ONE DOOR…
- 26 May 2005
Battery Pack, inoperative
DFW - CEILING EMERGENCY LIGHTS ABOVE ROWS 12 TO 16 AND 22 TO 29 INOPERATIVE. REPLACED BATTERY PACKS FOR CEILING EMERGENCY LIGHTS ABOVE ROWS 12 TO 16 AND 22 TO…
- 1 Feb 2004
Circuit Breaker, unsecure
ORD INFLIGHT T227/01 CENTER FUEL TANK UNABLE TO TRANSFER FUEL. DIVERTED TO TUL. LANDED WITHOUT INCIDENT. FOUND AFT CENTER TANK BOOST PUMP CIRCUIT BREAKER IN…
- 2 Sep 2003
Battery Pack, discharged
DEN - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHT WAS INOPERATIVE LEFT SIDE FORWARD OF THE AFT ACCESSORY DOOR. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED…
- 29 Jan 2003
Oil System, leaking
DFW - FLT 528 - AFTER TAKEOFF, CABIN AND COCKPIT STARTED TO FILL WITH SMOKE. RETURNED AND LANDED DFW WITHOUT INCIDENT. REPLACED NR 1 ENGINE DUE OT OIL LEAK AT…
- 8 Dec 2000
Web, cracked
TUL - FOUND CRACK FROM LIGHTENING HOLE IN CUSP STATION 228 LEFT SIDE. INSTALLED DOUBLER PER AARD 53-00-00-02 AND SRM 53-01 FIG 4. (M)
- 7 Dec 2000
Seat Track, damaged
TUL - FOUND NR 4 SEAT TRACK WORN AT STATION 498. REMOVED DAMAGED AREA AND INSTALLED PLUG IN NR 4 SEAT TRACK STATIN 498 PER SRM 53-05 PART 1 FIG 4A SHEET 1/2.…
- 7 Dec 2000
Seat Track, corroded
TUL - FOUND CORROSION ON SEAT TRACK NR 1 AT STATION 1236. ACCOMPLISHED PLUG REPAIR ON TRACK PER SRM 53-05 FIG 4A. (M)
- 7 Dec 2000
Seat Track, corroded
TUL - FOUND CORROSION ON SEAT TRACK NR 1 AT STATION 1208. ACCOMPLISHED PLUG REPAIR ON TRACK PER SRM 53-05 FIG 4A. (M)
- 6 Dec 2000
Web, corroded
TUL - FOUND CUSP BULGING CORRODED STATION 314. CUT OUT CORRODED SECTION ON LEFT CUSP STATION 14. INSTALLED DOUBLER PER SRM 53-01. (M)
- 6 Dec 2000
Seat Track, corroded
TUL - FOUND CORROSION ON SEAT TRACK NR 2 AT STATION 1200. REPLACED SEAT TRACK NR 2 STATION 1186-1223. REPLACED PER SRM 51-10. (M)
- 2 Dec 2000
Angle, gouged
TUL - FOUND TWO GOUGES IN RADIUS OF REPAIR ANGLE ON 1463 CANT FRAME JUST BELOW NR 18L LONGERON. BLENDED GOUGES, NDT CHECKED. INSTALLED DOUBLER PER 53-10-00-15…
- 20 Aug 2000
Wire, broken
ORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT SEAT 5E INOPERATIVE. REPAIRED WIRE AT SEAT 5E. SYSTEM GROUND CHECK NORMAL OPERATION.…
- 30 May 1999
Sensor, defective
ORD - FLT 1063 - EN ROUTE YYZ-ORD, DURING CLIMB, THE GEAR DOOR LIGHT ILLUMINATED. FOLLOWED CHECKLIST, TURNED ON RIGHT ENGINE HYDRAULICS AND LIGHT REMAINED OFF…
- 30 May 1999
Sensor, defective
ORD - FLT 1063 - EN ROUTE YYZ-ORD, GEAR DOOR OPEN LIGHT ILLUMINATED DURING CLIMB AT APPROX 300 KNOTS. ABNORMAL PROCEDURE WAS FOLLOWED AND RIGHT PUMP PLACED IN…
- 28 May 1999
Sensor, damaged
ORD - FLT 2268 - EN ROUTE DFW-ORD, GEAR DOOR OPEN LIGHT FLICKERED AND CAME ON INTERMITTENTLY DURING CLIMB IN LIGHT CHOP. LIGHT CAME ON STEADY AT CRUISE…
- 26 Apr 1999
Light, inoperative
PHX - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS IN FIRST CLASS CABIN WERE INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN…
- 9 Feb 1998
Sensor, defective
SFO - FLT 1041 - DURING APPROACH SFO, GEAR WAS EXTENDED AND THE LEFT MAIN GEAR INDICATED IT WAS NOT DOWN AND LOCKED. CREW ACCOMPLISHED ALTERNATE GEAR…
- 13 Aug 1997
Seat Track, corroded
TUL - NR 2 SEAT TRACK CORROSION STATION 207. SEAT TRACK REPLACED IN AREA, SRM 53-05 FIG 4. (M)
- 7 Aug 1997
Cusp Membrane, corroded
TUL - LEFT CUSP MEMBRANE HAS CORROSION. INSTALLED DOUBLER ON CUSP MEMBRANE PER SRM 53-01 FIG 4. (M)
- 6 Aug 1997
Cusp Membrane, corroded
TUL - LEFT CUSP MEMBRANE HAS CORROSION. INSTALLED DOUBLER ON CUSP MEMBRANE PER SRM 53-01 FIG 4. (M)
- 6 Aug 1997
Cusp Membrane, corroded
TUL - LEFT CUSP MEMBRANE HAS CORROSION. INSTALLED DOUBLER ON CUSP MEMBRANE PER SRM 53-04 FIG 4. (M)
- 24 Mar 1997
Air Distribution, odor
DFW - FLT 1593 - DURING DESCENT INTO DFW AT FL 140, BURNING PLASTIC ODOR NOTED IN CABIN WITH NO SMOKE EVIDENT. ODOR DISSIPATED PRIOR TO LANDING AND AIRCRAFT…
- 16 Dec 1996
Engine, leaking oil
MIA - FLT 1989 - AFTER T/O MIA, DURING INITIAL CLIMB-OUT, SMOKE NOTED IN COCKPIT AND CABIN. AIRCRAFT RETURNED TO MIA AND LANDED OVERWEIGHT WITHOUT INCIDENT.…