- 1 Sep 2014
Light, loose
EMERGENCY EXIT LIGHT STRIP LOOSE NEAR ROW 11. SECURED THE LIGHT AND OPS CHECKED NORMAL.
- 23 Mar 2014
Pca, malfunctioned
SPOILERS EICAS MSG & OVERHEAD LIGHT ON. REPLACED NR 3 SPOILER PCA IAW AMM 27-61-02, OPERATIONS TESTED OK.
- 10 Dec 2013
Fmc, failed
ENROUTE DUAL FMC FAILURE. WHILE OPERATING ON CTR AUTOPILOT, LOST ALL MCP FUNCTIONS. AUTOPILOT DID NOT DISCONNECT. BOTH FMC'S LOST ALL INFO.
- 22 Oct 2013
Check Valve, faulty
DURING TROUBLESHOOTING THE FUEL CONFIG LIGHT PROBLEM THE LT OR RT TANK SHOWED NO TRANSFER WITH BOOST PUMP PRESSURE ON. AFTER DEFUELING RT & CTR TANK & NO PUMP…
- 6 Oct 2013
Rivet, loose
FIRST OFFICER`S ELEVATOR CONTROL AFT QUADRANT ASSEMBLY 251N2061-26 HAS PLAY AT THREE EACH RIVETS, SEE CMM 27-31-70 PG1010. REMOVED FWD & RT HAND RIVET &…
- 30 Sep 2013
Bypass Valve, leaking
FOUND LE SLAT BYPASS VALVE LEAKING HYD FLUID & MISTING FLUID. REPLACED LE SLAT BYPASS VALVE IAW AMM, OPERATIONS CHECKED OK, NO LEAKS.
- 18 Aug 2013
Bottle, depleted
L1 DOOR FWD ESCAPE SLIDE ASSIST BOTTLE BETWEEN BANDS. REPLACED DOOR 1L ASSIST BOTTLE.
- 15 Aug 2013
Control Module, failed
L1 SPOILER MODULE HAS A PCA FAULT INDICATION TAHT WILL NOT RESET. REPLACED L1 SPOILER CONTROL MODULE PER AMM, CHECKED OKAY.
- 3 Aug 2013
Bellcrank, loose
ELEVATOR BUMP, FOUND AFT QUADRANT CAPTAIN BELLCRANK ATTACH RIVETS HAVE PLAY. REPLACED BLIND LOCK BOLTS.
- 3 Aug 2013
Unknown, defective
L1 DOOR WILL NOT LATCH FROM THE OUTSIDE. FOUND FOLLOWING ITEMS DEFECTIVE, REF IPC 52-11-13-001C PG2, NR 365, NR 370, NR 115 AND NR 100. REPLACED ABOVE ITEMS…
- 23 Jul 2013
Drive Unit, failed
GATE RETURN, CREW REPORTED WEATHER RADAR FAILED. FAILURE INDICATION ON THE HSI'S SHOW ANTENNA INDICATION. REPLACED DRIVE UNIT.
- 22 Jul 2013
Transceiver, faulty
NR 3 WEATHER RADAR FAILED DISPLAYED ON HSI. REPLACED WEATHER RADAR TRANSCEIVER AMM, OPS CHECKED GOOD.
- 3 Jun 2013
Cap, missing
EMERGENCY LIGHT END CAP MISSING. INSTALLED END CAP.
- 22 Apr 2013
Fuse, leaking
AFTER LANDING HAD LOSS OF HYDRAULIC FLUID IN RIGHT SYSTEM. REPLACED NORMAL ANTISKID MODULE HYDRAULIC FUSE IN LEFT WHEEL WELL, BOTTOM FUSE. BRAKES OPS NORMAL,…
- 8 Apr 2013
Lens, obstructed
COCKPIT THRESHOLD STEP LIGHT DOES NOT ILLUMINATE WITH COCKPIT DOOR OPEN. STEP LIGHT COVER LENS PAINTED OVER. BULB WORKS. CLEANED PAINT FROM LENSE, INSTALLED…
- 1 Apr 2013
Valve, failed
THE NR 2 LEFT MAIN TANK DEFUELING VALVE ACTUATOR INDEX PLATE FAILED ALIGNMENT CHECK. REPLACED LEFT MAIN DEFUEL VALVE.
- 19 Mar 2013
Ace, malfunctioned
FORWARD CARGO LOADING NESTING SYSTEM WILL NOT EXTEND. THE ACE CARGO LOADING SYSTEM IS THE SUBJECT OF AD2000-20-16, WHEN CLEARING THE DEFERRED ITEM REMOVE…
- 18 Jan 2013
Skin, cracked
L-4 DOOR INTERNAL SKIN CRACKED AT LIGHTENING HOLE AT UPPER AFT CORNER. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE & ACP HFEC FOR CRACKS. NONE FOUND. FABRICATED…
- 18 Jan 2013
Frame, corroded
AFT CARGO BS 1400 FRAME CORRODED JUST ABOVE STR S30. CUT OUT DAMAGE & ACP HFEC OF CUT-OUT & FASTENER HOLES COMMON TO REPAIR. NO CRACKS. FABRICATED & INSTALLED…
- 18 Jan 2013
Skin, dented
DENT FOUND ON EXISTING EXTERNAL DOUBLER REPAIR THAT WAS INSTALLED AT APPROX BS 600-630 BETWEEN STR S15L-18L. TWO OTHER ADJACENT DENTS WERE FOUND WITHIN SRM…
- 14 Jan 2013
Sill, corroded
FORWARD CARGO BAY DOOR CUTOUT LOWER SILL 3E A DOOR LOCK FITTING SUPPORTS HAVE CORROSION. REMOVED & REPLACED FWD CARGO COMPT CUTOUT LOWER SILL IAW SRM 51-40-02…
- 6 Jan 2013
Skin, dented
DENT FOUND AT BS 564 BETWEEN STR 15L-16L. EVALUATED DENT AND FOUND OUT OF SRM LIMITS. CUT OUT DAMAGE & ACP NDT OF CUTOUT AREA. NO CRACKS. FABRICATED &…
- 18 Nov 2012
Sill, damaged
FOUND AFT CARGO DOOR SILL DAMAGED FROM IMPACT. DOOR SEAL ON BOTTOM DAMAGED ALSO, DOOR SEAL TRACK DELAMINATED FROM FUSELAGE. DOOR SILL BULL NOSE HAS DENT ALSO.…
- 29 Oct 2012
Oxygen Mask, faulty
F/O OXY MASK HOT MIKE WHEN MASK SELECTED. SFOMM..ACTUALLY CONTINUOUS STUCK MIC ON F/O'S SIDE WITH ANY MIC AND ANY PTT SWITCH PUSHED. SWAPPED AUD SEL PANEL AND…
- 22 Sep 2012
Oven, smoke
SMOKE FROM OVEN IN FWD GALLEY. 2 EXTINGUISHERS USED FIRE EXTINGUISHED. SMOKE DISSIPATED. REPLACED FWD GALLEY OVEN.
- 28 Mar 2012
Inlet, pinched
FWD PIT FAILS SMOKE DETECTION TEST AT AFT SMOKE PICK-UP. ALL OTHER PORTS WORK NORMALLY. FOUND SMOKE INLET PINCHED. REPOSITIONED RUBBER INLET. OP CHECKED OKAY.
- 2 Jan 2012
Floor Panel, damaged
AFT GALLEY FLOORING PEELING UP NOT ALLOWING CARTS TO BE PULLED OUT. MAINT TEXT: APPEARS TO BE LOTS OF MOISTURE UNDER FLOOR PAN AT REAR CART NEXT TO AFT LAV,…
- 30 Oct 2011
Fseu, malfunctioned
FLAPS FAILED TO MOVE. TRAILING EDGE LIGHT ILLUMINATE. EICAS MESSAGE 'T/E FLAP DISAGREE' & 'FLAP ISLN VAL' DISPLAYED. REPLACED FSEU 3 PER MM. 201 DUE TO BITE…
- 11 Sep 2011
Lug, damaged
FIRST OFFICER INST XFER STATUS MESSAGE PRESENT. DURING TROUBLESHOOTING, FOUND A SET OF BURNED WIRE LUGS AT TERMINAL BLOCK TB5014 PHASE A INSIDE OF THE P6-4…
- 23 May 2011
Light, loose
EMERGENCY LIGHT STRIP LOOSE BY FWD F/A JUMPSEAT. SECURED, CHECKED OPERATION.
- 17 Feb 2011
Panel, corroded
CORROSION ON SHEAR WEB PANEL AT STA 1703 TO 1720, THIS DAMAGE WAS AT RBL 50 AND WAS REPAIRED IAW PD57-53-083 WITH APPROVAL AND 8100-9 AND CONSIDERED PERMANENT.
- 17 Feb 2011
Floor Panel, corroded
MAIN CABIN FLOOR AT STA 1680 BL-0 TO LBL-18 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION ON DECK PLATE. OUT OF LIMITS. INSTALLED DOUBLER REPAIR…
- 17 Feb 2011
Floor Support, corroded
INTERCOSTAL FLOOR DECK AT STA 1686 RBL-50 HAS CORROSION UNDER MOUNT. REPAIRED IAW EA NR 57-53-083. APPROVED IAW AND CONSIDERED A PERMANENT REPAIR.
- 16 Feb 2011
Skin, gouged
DOOR 1R HAS GOUGE IN INTERIOR SKIN UNDER TORQUE TUBE. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR.
- 15 Feb 2011
Support Angle, corroded
CORROSION FOUND ON SUPPORT ANGLE AT DOOR 4 RT STA 1681, RBL 56. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION REMOVAL FOUND TO BE BEYOND LIMITS AND FOUND A CRACK…
- 15 Feb 2011
Crease Beam, corroded
MAIN CABIN T-CHORD HAS CORROSION FROM STA 1030 TO 1040 AT RBL 70. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION WAS REMOVED IT WAS FOUND TO BE BEYOND LIMITS AT…
- 24 Jul 2010
Cooling Fan, defective
ACRID ELECTRICAL SMELL IN COCKPIT. FOUND TRACE OF RESIDUAL ODOR. OPS CHECKED WINDOW ANTI-ICE SYSTEM. FAINT SMELL IN E&E COOLING DUCTING. REPLACED PRIMARY…
- 22 Jun 2010
B-Nut, loose
APU 3 START ATTEMPTS WITH APU FAULT EACH TIME. 99 PERCENT OF FAILED STARTS OCCUR IN DEN USUALLY OK NEXT STA CHECK ALL THE MUSCLE LINES FOR LEAKS & SECURENESS…
- 4 Jun 2010
Light, damaged
CABIN ROW 28 ABC EMERGENCY LIGHT CROSSOVER WAS FOUND DAMAGED. R & R EMERGENCY LIGHT CROSSOVER AT ROW 28ABC AND OPS CHECK.
- 4 Jun 2010
Wire, broken
CABIN ROW 14ABC EMERGENCY LIGHT CROSSOVER LEAD BROKEN NEEDS REPLACEMENT. R & R EMERGENCY LIGHT CROSSOVER AT 14ABC AND OPS CHECK.
- 9 Feb 2010
Switch, failed
L/E SLAT ASYM EICAS, RTFL. REPLACED LT INBD SLAT LOSS SENSING SWITCH S10589. CYCLED SLATS SEVERAL TIMES WITH NO ASYM MSGS.
- 27 Dec 2009
Oven, smoke
ELECTRICAL SMOKE SMELL IN CABIN CENTERED AROUND DOOR 2L DURING DESCENT. SUPPLEMENTAL DATA UPDATE ACP CHECK OF ALL LIGHTING SYSTEM IN ACFT ON BRIGHT AND DIM,…
- 23 Nov 2009
Control Panel, faulty
CAPTS O2 MASK MICROPHONE INOPERATIVE. REPLACED MASK ASSY, NO HELP. REPLACED CAPT'S AUDIO CONTROL PANEL, OP CHECK NORMAL.
- 25 Oct 2008
Light, inoperative
THREE RT MED EXTERIOR EMERGENCY LIGHT INOP. REPLACED LAMP, OPS GOOD.
- 21 Aug 2007
Manifold, cracked
FLIGHT DIVERTED DUE TO NR 2 ENG LOSS OF OIL QTY AND LOW OIL PRESSURE. REPORT OF BREATHER MANIFOLD CRACKED AND CLAMP BROKEN. NO DEBRIS FOUND. REPLACED MANIFOLD…
- 26 Jul 2007
Lamp, inoperative
EXTERIOR EMERGENCY LIGHT AT DOORS 1R, 2R AND 4R ARE INOPERATIVE. REPLACED LAMP.
- 4 Jul 2007
Manifold, cracked
NR 2 ENGINE EGT EXCEEDED 645 DEGREES, NOT DURING SURGE. PEAK EGT WAS 664. CREW COMMENTS, AT TAKEOFF WITH FULL THRUST FOR WEATHER LASTED FOR 6 MINUTES. TEMP…
- 25 May 2005
Skin, misdrilled
LT FUSE SKIN AT STA 1181 STR 16L HAS DRILL DAMAGE. REMOVED DAMAGED AREA AND FABRICATED FREEZE PLUG AND DOUBLER PER REO G09831 AND EVA-40157
- 24 May 2005
Frame, damaged
FUSELAGE FRAME AT STA 600 BETWEEN STR 24L AND 24L REQUIRE DTA TO BE ACCOMPLISHED. REMOVED FRAME SECTION AND FABRICATED REPAIR PARTS PER REO G09843 REV 1.
- 11 Aug 2004
Connector, disconnected
EXIT INDICATOR LIGHTS AT DOORS 4L AND 4R INOPERATIVE. FOUND CONNECTORS D6634 AND D6674 DISCONNECTED FROM INVERTER M10834. RECONNECTED WIRING. SYSTEM OPERATES…
- 12 Jun 2004
Frame, dented
BS 600 FRAME BETWEEN STR 24L AND 25L DENTED. MAJOR REPAIR ACCOMPLISHED. FABRICATED FRAME REPAIR.
- 12 Jun 2004
Frame, damaged
STA 580, STR 24L-25L FRAME HAS DAMAGE INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 12 Jun 2004
Frame, damaged
FUSELAGE FRAME AT STA 600 BETWEEN STR 24L AND 25L IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR PARTS.
- 12 Jun 2004
Frame, dented
FUSELAGE FRAME STA 1400, STR 25L-27L IS DENTED 3 AREAS. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 12 Jun 2004
Frame, dented
FUSELAGE FRAME AT STA 1420 STR 25L HAS THREE DENTS. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW FRAME REPAIR.
- 12 Jun 2004
Frame, corroded
AFT PIT FRAME CORRODED AT UPPER FLANGE STA 1500, LBL 4 - 8. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 8 Jun 2004
Floor Panel, cracked
FLOOR WEB APPROX 1 INCH AFT OF BS 199.9 AND HALF INCH INBOARD FROM FUSELAGE SKIN ON RIGHT SIDE CRACKS EMANATING FROM FASTENER BUCK TAIL. FABRICATED &…
- 7 Jun 2004
Floorbeam, corroded
EXFOLIATION ON MAIN CABIN FLOORBEAM STA 324, RBL 62. TEE ANGLE REPAIR INSTALLED.
- 7 Jun 2004
Floorbeam, corroded
CABIN FLOORBEAM FS 1640 HAS CORROSION AROUND NUT PLATE HOLES FROM RBL 14 TO RBL 44 UPPER AFT FLANGE BOTH SIDES OF FLANGE. FABRICATED & INSTALLED FLOORBEAM AND…
- 4 Jun 2004
Floorbeam, corroded
CABIN FLOORBEAM STA 1640 HAS CORROSION AROUND SEVERAL NUT PLATES HOLES FROM RBL 14 TO RBL 44, UPPER FLANGE, LWR AND UPPER SURFACES. FABRICATED & INSTALLED NEW…
- 4 Jun 2004
Skin, dented
AFT CARGO DOOR HAS SKIN DENT AFT LWR CORNER. INSTALLED DOUBLER REPAIR.
- 2 Jun 2004
Frame, dented
BS 580 FRAME BETWEEN STRINGERS 24L AND 25L HAS A DENT (LBL 30). MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE REPAIR.
- 2 Jun 2004
Floorbeam, corroded
CABIN FLOORBEAM UPPER CAP CORRODED AROUND FASTENER HOLES STA 365 AT RBL 26 TO 44. MAJOR REPAIR ACCOMPLISHED. INSTALLED FLOORBEAM SPLICE REPAIR.
- 30 May 2004
Floorbeam, corroded
CABIN FLOORBEAM UPPER CAP CORRODED AT STA 365 RBL 9 TO 16. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLE AND STRAPS.
- 27 May 2004
Floorbeam, corroded
CABIN FLOORBEAM UPPER CAP CORRODED AT STA 310 RBL 42. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FILLER & CAP REPAIR.
- 1 Oct 2003
Light, inoperative
RT AFT DOOR EXTERIOR EMERGENCY-SLIDE RAFT LIGHT IS INOPERATIVE. RELAMPED. CHECKS OK.
- 21 Sep 2003
Actuator, failed
RIGHT MAIN GEAR DOOR FOUND FULL OPEN UPON GATE ARRIVAL. FAILED MLG DOOR RETRACT ACTUATOR. ACTUATOR WAS REPLACED.
- 22 Mar 2002
Hydraulic Line, ruptured
LOSS OF LEFT HYDRAULIC QUANTITY LEVEL DECREASED TO 1.8 WITH ASSOCIATED SYSTEM PRESSURE LIGHT ILLUMINATION. LEFT MAIN DOWNLOCK ACTUATOR HYDRAULIC LINE…
- 3 Oct 2000
Bottle, discharged
RT OVERWING BOTTLE PRESS INDICATION INOP DURING TEST NR 2 OF SQUIB TEST PANEL ON P-61. *S/D* INSTALLED NEW BOTTLE.
- 21 Jun 1999
Actuator, failed
LANDED IAD UNDER AMBER ALERT DUE TO LEADING EDGE FLAP DISAGREE LIGHT. *S/D* LEADING EDGE SLAT BINDING IN THE NUMBER ONE POSITION. ROTARY ACTUATOR CAUSED THE…
- 20 Jun 1999
Actuator, failed
LANDED SFO UNDER AMBER ALERT DUE TO SLAT DISAGREE LIGHT. *S/D* LEADING EDGE SLAT BINDING IN THE NUMBER ONE POSITION. ROTARY ACTUATOR CAUSED THE OVERLOAD…
- 6 Jun 1999
Speed Card, malfunctioned
FLIGHT RETURNED TO ORD DUE TO THE LOSS OF THE NR 2 ENGINE SPEED CARD. REPLACED THE N-2 SPEED CARD AND ENGINE CHECKED OK ON THE CONTINUING FLIGHTS.
- 28 Jul 1998
Blade, cracked
THREE LOUD JOLTS CAME FROM RIGHT ENGINE DURING CLIMB. *S/D* ENGINE WAS REPLACED AND A FAILED 6TH STAGE HPC BLADE WAS DISCOVERED AFTER ENGINE DISASSEMBLY. THE…
- 3 Oct 1997
Lights, inoperative
WHEN OVERHEAD PANEL SWITCH ARMED, EMERGENCY LIGHTS ON DOORS 1L, 1R, CENTER LAV, OVERHEAD BINS IN FIRST CLASS, AND A SECTION OF EEL STRIP IN FIRST CLASS INOP.
- 30 Sep 1997
Wire, worn
REPEAT GRIPES FOR FORWARD EMERGENCY LIGHTS COMING ON IN FLIGHT, BOTH LEFT AND RIGHT SIDE. SUSPECT WIRING PROBLEM. *S/D* FOUND WIRES W3054-006-18 AND…
- 10 Sep 1997
Battery Pack, discharged
AT DEPARTURE, EEL LIGHTS CAME ON AND WOULD NOT EXTINGUISH. *S/D* SWOPPED NEW BATTERY AND CHARGER IN BOTH FWD POSITIONS, NO HELP. NEW BATTERY AND CHARGER…
- 21 Jun 1997
Connector, loose
EEL LIGHTS FROM RAW 25 TO RAW 32 WERE INOP. RESEATED POWER FEEDER CONNECTORS, SYSTEM TEST WAS NORMAL.
- 6 May 1997
Idg, failed
LEFT CONSTANT SPEED DRIVE LIGHT CAME ON AND GENERATOR DROPPED OFF LINE. AIRCRAFT RETURNED TO FIELD. REPLACED LEFT INTEGRATED DRIVE GENERATOR (IDG) AND LEFT…
- 22 Jul 1996
Engine, lost power
LOST POWER ON NR 1 ENGINE DURING APPROACH TO ORD. ENGINE INDICATIONS AND CREW ALERT SYSTEM (EICAS) SHOWED TWO HARD FAULTS AGAINST THE FUEL CONTROL UNIT (FCU).…
- 21 Jul 1995
Reservoir, discharged
PRIOR TO DEPT, LT FWD ENTRY DOOR EMER PWR RESERVOIR PRESSURE THERMALLY DISCHARGED. INSTALLED NEW DISCHARGE KIT AND SERVICED RESERVOIR.