N557UA
1992 Boeing 757-222 standard FAA →
reservations
earlier registrations
1 past record
- 1992
service difficulty reports
82 reports
- 3 Sep 2013
Line, leaking
FLUID LEAK REPORTED TO AIRCRAFT ON TAXI OUT FROM ANOTHER AIRCRAFT. FLUID LEAK FROM LT MLG DRIP AFTER ONE AND A HALF HOUR LT HYDRAULIC QUANTITY WENT FROM .94…
- 12 Aug 2013
Seal, leaking
NR 2 ENGINE, SIGNIFICANT QTY OF OIL FOUND UNDER ENGINE AND ON COWL DURING AND AFTER A-CK 5 MINITE IDLE. RUNNING OIL FROM DEOILER BREATHER TUBE, DRIPS FROM…
- 22 Jun 2013
Switch, stuck
CAPTAIN`S MICROPHONE SWITCH ON YOKE STUCK. FOUND PTT SWITCH FAILED. REPLACED SWITCH & OPS CHECKED OK.
- 20 Jun 2013
Terminal Block, missing
L1 WINDOW MISSING CAP FOR WINDOW HEAT POWER. REPLACED WINDOW HEAT TERMINAL BLOCK, WINDOW HEAT, OPS CHECKED NORMAL.
- 18 Jun 2013
Power Supply, failed
ELECTRICAL ODOR IN CABIN. REPLACED GOOSE NECK LIGHT POWER SUPPLY THAT SMELLED OF SMOKE. OP CHECKED GOOD.
- 26 Apr 2013
Light, inoperative
SEAT EMERGENCY LIGHT AT ROWS 20 & 23 INOPERATIVE. REPLACED EMERGENCY LIGHT, OPS CHECKED NORMAL.
- 26 Apr 2013
Lamp, inoperative
EMERGENCY LIGHT INOPERATIVE. REPLACED LAMPS, OPS CHECKED NORMAL.
- 25 Apr 2013
Unknown, odor
CREW REPORTED ARCING AND FUMES FROM POWER BOX UNDER SEAT 20 DE. ACCOMPLISHED CHECK OF PC OUTLET CHECKED OK REACTIVATED.
- 17 Apr 2013
Lens, unsecure
EXIT ROW LIGHT LOOSE AT RIGHT SIDE OVERWING. SECURED LENSE. ACCOMPLISHED INSPECTION OF LENSE ASSY SECURITY. FOUND IN AIRWORTHY CONDITION.
- 20 Mar 2013
Lens, unsecure
EXIT SIGN INOP AT SEATS 9CD. SECURED EXIT SIGN LENS AT 9CD, OPS CHECK OKAY.
- 7 Dec 2012
Stringer, damaged
STRINGER 16 LEFT BETWEEN STA 600 AND 620 HAS ELONGATED HOLES. CATEGORY 'A' STRINGER REPAIR INSTALLED TO S-16L BETWEEN STA 593 AND 645 REQUIRES SUPPLEMENTAL…
- 6 Dec 2012
Structure, dented
LWR FUSELAGE HAS DENT JUST BELOW FWD RT NOSE NUMBER. AT C CHECK FOUND DENT TO BE OUT OF LIMITS. CUT OUT DAMAGE AND INSTALLED CATAGORY 'B' RPR DBLR PER SRM…
- 6 Dec 2012
Skin, damaged
FUSELAGE SKIN AT R-4 DOOR CUTOUT LOWER EDGE HAD 3 EACH MISDRILLED HOLES. INTERIM REPAIR INSTALLED STA 1655-1675 BETWEEN S-15R AND S-19R PER ECRA 5330-04378…
- 2 Dec 2012
Skin, damaged
FUSELAGE SKIN AT R-1 DOOR CUTOUT LOWER EDGE HAS 6 EACH MIS-DRILLED HOLES. INTERIM REPAIR INSTALLED STA 320-370 BETWEEN S-15R AND S-18R PER ECRA 5330-04377.
- 2 Dec 2012
Spar, damaged
INTERIM REPAIR TO THE RIGHT INBD MAIN FLAP FRONT SPAR LWR CHORD AT MFS 223. REF ECRA 5750-04506.
- 26 Nov 2012
Skin, dented
SEVERAL DENTS STA 620 BETWEEN S-16L AND S-18L AROUND PREVIOUS RPR DOUBLER. INSTALLED LARGER FUSELAGE SKIN RPR AT LOCATION PER SRM 53-30-01 RPR 2. DUE TO OTHER…
- 26 Nov 2012
Skin, dented
DENT IN FUSELAGE SKIN AT BS 623 AND STR 16L. DUE TO OTHER DAMAGE AT THIS LOCATION A LARGE REPAIR HAS BEEN INSTALLED PER SRM 53-30-01.
- 26 Nov 2012
Skin, dented
LEFT FUSELAGE STA 600, HAS SKIN DENT JUST ABOVE STR 18L. HFEC INSP, NO CRACKS NOTED. 1.25 X .032 = 47. PER SRM 53-00-01, NO ACTION REQUIRED. OK TO ARCHIVE.…
- 25 Oct 2012
Igniter, faulty
NR 2 ENGINE START, NO START USING NR 1 IGNITOR. REPLACED NR 1 IGNITOR PLUG AND IGNITOR NR 1 ON ENGINE 2 ACCOMPLISHED ENG RUN IAW JRH 2-5-1, OP CHECK NORMAL.
- 3 Oct 2012
Pump, leaking
FOUND RIGHT ELECTRICAL HYDROLIC PUMP WAS LEAKING AT THE DRAIN HOLE. OPERATION CHECKED AND RUN HYDRAULIC SYSTEM. FOUND 37 DROPS PER MINUTE CAME OUT OF DRAIN…
- 7 Aug 2012
Unknown, odor
STRONG ODOR COMING FROM VENTILATION SYSTEM FROM DOOR 2L AREA. ODOR LOCALIZED TO DOOR 2 MID-GALLEY AREA ONLY: LENGTH OF AIRCRAFT OTHERWISE FREE OF ODOR. NO…
- 10 Jul 2012
Oil System, leaking
FLT CREW NOTES SLIGHT OIL ODOR IN CABIN WHEN APU BLEED IS ON. RAN ENGINES AT IDLE AND RAN BOTH PACKS. NO OIL ODOR NOTED AND CONDITION ACCEPTABLE TO THE CREW.…
- 7 Jul 2012
Unknown, odor
STRONG RAW FUEL ODOR AND VISIBLE VAPOR IN CABIN AFTER ENGINE START. ACCOMPLISHED HIGH POWER ENG RUNS AND APU OPS CHK ISOLATING ALL BLEED SOURCES INDIVIDUALLY.…
- 31 May 2012
Ballast, defective
ELECTRICAL BURNING ODOR NEAR DOOR 2. FOUND AFT FWD LAVATORY MIRROR LIGHT BALLAST DEFECTIVE AND LIGHTS OUT. ODOR DISSIPATED. BALLAST AND BULBS REPLACED, RAN…
- 31 May 2012
Ballast, defective
ELECTRICAL BURNING SMELL NEAR DOOR 2. FOUND AFT FWD LAV MIRROR LIGHT BALLAST DEFECTIVE & LIGHTS OUT. SMELL DISSIPATED. BALLAST CONNECTOR REMOVED, TAPED &…
- 28 May 2012
Engine, hung start
NUMBER 2 ENGINE HUNG START ON TWO ATTEMPTS. ATTEMPTED SECOND START WITH BOTH IGNITIONS ENGINE START PARAMETERS NORMAL, STARTS OKAY.
- 10 May 2012
Flap System, malfunctioned
TRAILING EDGE FLAP DISAGREE MESSAGE GOING FROM FLAPS 20 TO 25. LOCKOUT AT ABOUT FLAPS 20, MADE GO AROUND. SELECTED ALTERNATE FLAPS AND EXTENDED FLAPS TO FULL…
- 25 Apr 2012
Breather, leaking
FOUND DEOILER BREATHER LEAKING DURING RUN. ADDED 9 QTS OF OIL NR 1 ENGINE. PERFORMED IDLE LEAK CHECK, CHECKED CHIP DETECTORS, ACCOMPLISHED VISUAL CHECK OF…
- 7 Feb 2012
Oxygen System, low pressure
CREW O2 PRESSURE BELOW MIN LIMIT OF 1200. SERVICED CREW OXYGEN TO FULL.
- 5 Feb 2012
Light, broken
EEL LIGHT BROKEN AT SEAT 7B. REPLACED LIGHT ASSY, OPS CHECK GOOD.
- 11 Nov 2011
Slide, deployed
SLIDE NEEDS TO BE REPLACED DUE TO DEPLOYMENT. INSTALLED SLIDE 4L UP TO STEP 'F' ON PAGE 415 OF MM.
- 10 Nov 2011
Girt Bar, dirty
DOOR 3L WILL NOT ARM. CLN'ED GIRT BAR AREA. ARMED AND DISARMED DOOR. OPS CHECKED NORMAL.
- 2 Nov 2011
Window Frame, out of position
THE ENTIRE WINDOW FRAME FROM 16A JUST FELL OFF. SECURED WINDOW FRAME.
- 27 Sep 2011
Door, leaking
PASSENGER ENTRY-SERVICE DOORS RT FWD NOISE FROM AIR LEAK. LEAK IS VERY LOUD. NOISE IS FROM THE FWD, LOWER, CORNER. REPAIRED COMPOUND AT FWD AND AFT LWR…
- 25 Sep 2011
Door, damaged
PASSENGER ENTRY-SERVICE DOOR R1 FWD NOISE FROM AIR LEAK.FOUND PREVIOUS REPAIR COMPLETELY BLOWN OUT (SEALANT NOT CURED). CLEANED AREA AND REAPPLIED SEALANT.…
- 22 Jul 2011
Rod End, broken
NR 2 ENG AFT COMPRESSION ROD END BROKEN. REPLACED ROD ASSY.
- 11 Jul 2011
Chiller, faulty
AFT GALLEY CHILLER RED FAULT LIGHT ON. DEACTIVATE CHILLER PER MEL. REMOVED AND REPLACED CHILLER ASSY.
- 1 Jun 2011
Wedge, delaminated
NR 5 SLAT HAS LOWER SKIN DELAMINATED AT SLAT WEDGE APPROX 24 INCHES BY 7 INCHES AREA. DELAM STARTS APPROX 61-INCHES FROM INBD SLAT EDGE. REMOVED SLAT PER MM…
- 12 Jan 2011
Floorbeam, corroded
CORROSION DAMAGE ON THE UPPER SURFACE OF THE FLOORBEAM AT BS 324 BETWEEN RBL 50 AND RBL 60. THE SECTION WAS REMOVED AND REPLACED PER INSTRUCTIONS PER…
- 5 Jan 2011
Girt Bar, misinstalled
NR 1 LT MED GIRT BAR MECHANISM HARDWARE, HAS NUT HITTING DOOR FRAME. REMOVED AND INSTALLED GIRT BAR MECHANISM HARDWARE CORRECTLY IAW UAL SM.
- 5 Jan 2011
Girt Bar, misinstalled
NR 1 RT MED GIRT BAR MECHANISM HARDWARE HAS NUT HITTING DOOR FRAME. REMOVED AND INSTALLED GIRT BAR MECHANISM HARDWARE CORRECTLY IAW UAL SM.
- 23 Dec 2010
Floorbeam, corroded
CORROSION FOUND ON FLOORBEAM AT STA 1640. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND DETERMINED THAT MATERIAL LOSS IS BEYOND LIMITS. R & R FLOORBEAM TEE…
- 13 Nov 2010
Sign, dislodged
COCKPIT EXIT SIGN ABOVE RIGHT WING WINDOW EXIT FELL OFF. SECURED SIGN.
- 17 Aug 2010
Connector, damaged
IN-SEAT EMERGENCY LIGHT AT SEAT 23ABC INOP. RELAMPED, BUT NO HELP. FOUND PIN PUSHED BACK AND RESEATED PIN. OP CHECKED GOOD.
- 17 Aug 2010
Lamp, inoperative
IN-SEAT EMERGENCY LIGHTS AT SEAT 15ABC INOP. RELAMPED AND OP CKD GOOD.
- 16 Aug 2010
Slide, deployed
DOOR 4R - DOOR SLIDE DEPLOYED. REPLACED DEPLOYED SLIDE WITH SERVICEABLE SLIDE ASSY.
- 29 Apr 2010
Compressor, stalled
ENG COMPRESSOR STALL IN FLIGHT. ENG POSITION UNKNOWN. ENG RECOVERED AND CONTINUED OPERATING. IMMED PRECEDING STALL, ENG POWER WAS ACCELERATING AT CRUISE OR…
- 25 Apr 2010
Elevator, damaged
LT ELEVATOR DAMAGE AT TRAILING EDGE. LT ELEVATOR REMOVED. COMPLETED ELEVATOR INSTALLATION. INSTALLED STATIC WICKS ON NEW LEFT ELEVATOR.
- 19 Apr 2010
Lens, dislodged
EXIT SIGN OVER 2L FELL OFF. LENS FOUND UNSECURE. REPLACED EXIT SIGN LENS. OK FOR SERVICE.
- 26 Mar 2010
Lamp, inoperative
EMERGENCY EXIT LIGHTS INOP ABOVE 8AB AND 10AB. RELAMPED LIGHTS. OPS CHECK GOOD.
- 25 Aug 2009
Mechanism, lack of lube
F/A REPORT THAT DOOR 3R DID NOT FULLY DISARM. REMOVED SLIDE ASSY, LUBED DOOR AND CHECKED RIG AND REINSTALLED SLIDE ASSY. OPERATED DOOR ARM AND DISARM…
- 18 Jul 2009
Retainer, dirty
UNABLE TO DISARM R AFT DOOR. CLEANED DEBRIS OUT OF DOOR SLIDE RETAINER AND LUBED, DOOR ARM, DISARM OPS CHECKED NORMAL.
- 13 Dec 2008
Light, inoperative
EMERGENCY EGRESS LIGHT AT ROW 15A IS INOP. REPLACED LIGHT AND OPS CHECK GOOD.
- 25 Dec 2007
Oxygen Mask, faulty
OBSERVER`S O2 MASK WILL NOT SHUT OFF. FOUND 1ST OBS O2 MASK LEAKING AT HARNESS. REPLACED FIRST OBS O2 MASK, OPS CHECKED NORMAL.
- 28 Feb 2007
Hinge, cracked
DOOR 2R UPPER HINGE CUTOUT IS CRACKED. MAJOR REPAIR ACCOMPLISHED: TRIMMED OUT DAMAGE & ACCMP'D INSURANCE CUT. NO CRACKS FOUND. FABRICATED & INSTALLED REPAIR…
- 26 Feb 2007
Connector, damaged
EMERGENCY STRIP LIGHTS ROW 23 INOPERATIVE. [SUP 4-17-07] TROUBLESHOT EMERGENCY STRIP AT SEAT ROW 23. FOUND WIRE PULLED FROM CONNECTOR, REPAIRED CONNECTOR
- 26 Feb 2007
Gate, corroded
L-2 DOOR LOWER GATE CORRODED ON OUTER LOWER FLANGE SURFACES. [SUP 05-08-07] REMOVED CORROSION AND FOUND TO BE WITHIN SRM LIMITS. ORIGINAL MATERIAL THICKNESS…
- 19 Feb 2007
Altimeter, inoperative
FOUND CAPT'S ALTIMETER INOPERATIVE PER CREW. CYCLED CB AND ALT AIR DATA AND NO HELP. REPLACED NR 1 ALTIMETER
- 3 Jan 2007
O-Ring, leaking
LOW BOTTLE PRESSURE. FOUND A LEAKING FUSIBLE PLUG O-RING. REPLACED O-RING.
- 22 Oct 2006
Unknown, odor
FUMES/ODOR STRONG IN COCKPIT AFTER ENGINE START WITH PACKS OFF. VERY STRONG FROM TAKEOFF PWR THROUGH CLIMB. FOUND OIL COMING OUT BETWEEN THE NR 2 COMPRESSOR…
- 14 Oct 2006
A/C Pack, odor
FWD AND AFT CABIN AIR QUALITY IS POOR. EXTREMELY FOUL ODOR FROM PACKS AFTER LIFTOFF. AS PART OF TROUBLESHOOTING, CHECKED BOTH INLETS AND HEAT EXCHANGERS, GND…
- 25 Sep 2006
Squib, no test
RIGHT SIDE NR 2 SQUIB WOULD NOT TEST. OFFWING EVACUATION SLIDE BOTTLE PRESSURE MEASURED AT 2500 PSI. BOTTLE WAS HYDROSTATICALLY TESTED - NO FAULTS FOUND.…
- 11 Aug 2006
Idg, failed
LEFT GENERATOR OFF MESSAGE WITH NO DRIVE LIGHT ILLUMINATED. THIS DISCREPANCY IS ATTRIBUTED TO A FAILED IDG. WHEN APU STARTED EQUIP COOLING FANS FAILED TO COME…
- 11 Aug 2006
Odor, detected
DIVERTED TO DTW DUE TO AN ELECTRICAL SMELL IN THE AFT GALLEY. REPORTED CHILLER AMBER LIGHT INTERMITTENTLY ON. RUBBER BURNING SMELL AT AFT RIGHT ENTRY DOOR PER…
- 28 Jun 2006
Light, missing
EMERGENCY EEL LIGHT ASSY ON SEAT 19ABC IS MISSING. INSTALLED NEW LIGHT ASSY.
- 2 Jun 2006
Circuit Breaker, tripped
DIVERTED TO ORD DUE TO 4 POPPED GALLEY CIRCUIT BREAKERS. [06-29-07] RESET CB S' AND TESTED PER MM, COULD NOT DUPLICATE. OPS CHECKS OK. NO FURTHER OCCURENCES…
- 7 Jun 2004
Connector, miswired
EMERGENCY EXIT LIGHT L775 JUST FORWARD OF DOOR 1L INOP. FOUND CONNECTOR FOR LIGHT L775 WIRED WRONG. REWIRED CONNECTOR D6648 PER WD33-51- 21. LIGHT L775 TESTS…
- 13 Apr 2004
Skin, corroded
AFT PIT BILGE STA 1464 TO 1472, RBL 3, LOWER SKIN ANTENNA DOUBLER CORRODED ON UPPER SURFACE. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW ANTENNA…
- 13 Apr 2004
Frame, dented
AFT PIT FUSELAGE FRAME STA 1520 INNER FLANGE HAS DENT BELOW STR 25L. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR ANGLE.
- 13 Apr 2004
Frame, dented
AFT PIT FUSELAGE FRAME INNER FLANGE STA 1480 HAS A DENT AT STR 25L. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLE.
- 13 Apr 2004
Frame, dented
AFT PIT FUSELAGE FRAME STA 1440, INNER FLANGE HAS A DENT AT STR 26L. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLE.
- 13 Apr 2004
Frame, dented
AFT PIT FUSELAGE FRAME INNER FLANGE HAS DENT STA 1420, STR 26L. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLE.
- 13 Apr 2004
Frame, dented
AFT PIT FUSELAGE FRAME STA 1580 INNER FLANGE HAS 2 DENTS BETWEEN STR'S 25R-26R. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLE.
- 13 Apr 2004
Frame, dented
AFT PIT FUSELAGE FRAME STA 1400 INNER FLANGE HAS A DENT AT STR 26L. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLE.
- 13 Apr 2004
Sill, corroded
DOOR 1R LOWER SILL CORRODED ATTACH ANGLE CORRODED STA 375-377, RBL 61. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR ANGLE.
- 13 Apr 2004
Sill, corroded
CABIN R-2 DOOR SILL ATTACH ANGLE AND SIDE FRAME ATTACH ANGLE CORRODED STA 1690 AND APPROX RBL 60. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR…
- 13 Apr 2004
Shear Tie, cracked
AFT CARGO PIT STA 1300, STR 20L-21L, SHEAR TIE IS CRACKED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SHEAR TIE.
- 7 Apr 2004
Floorbeam, corroded
FLOORBEAM T-CAP AT STA 1640 RBL 60 IS CORRODED. REMOVED T-CAP. FABRICATED AND INSTALLED NEW T-CAP AND ANGLE.
- 5 Apr 2004
Frame, dented
AFT PIT FUSELAGE FRAME INNER FLANGE STA 1480 STR 25L HAS DENT. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR SPLICE.
- 21 Mar 2002
Switch, faulty
RIGHT ENGINE OIL FILTER EICAS MSG AND RIGHT OIL FILTER STATUS MESSAGE APPEARED IN FLIGHT. EICAS MESSAGE EXTINGUISHED AFTER ONE MINUTE. OIL FILTER & BYPASS…
- 9 May 1999
Seal, failed
DIVERTED TO BOI DUE TO LOSS OF APU GENERATOR. THE LEFT GENERATOR WAS LOST ON TAKEOFF. *S/D* APU SHUTDOWN WITH 'APU OIL QTY' MSG. FOUND OIL DRIPPING FROM DRAIN…
- 3 Feb 1999
Tube, leaking
SLIDE FAILED AIR RETENTION TEST DURING SHOP VISIT. *S/D* POROSITY CAUSED SEAM LEAK. UNIT WAS SENT TO VENDOR FOR EVALUATION AND REPAIR.