N556JB
2002 Airbus A320-232 standard FAA →
registration
- 2002
service difficulty reports
116 reports
- 9 Nov 2026
Sight Glass, unsecure
FLT 848. CLT-FLL. R2 DOOR BUSTLE HAS TAPE HOLDING THE SIGHT GLASS IN PLACE.
- 13 Jan 2026
Unknown, odor
FLT 2023, BOS- STI. ABNORMAL FUEL SMELL FROM AFT GALLEY TO ROW 21 DURING LANDING. APU WAS STARTED 1 MIN PRIOR TO LANDING. COMPLIED WITH INFO NOTICE 2017-T015…
- 9 Dec 2025
Unknown, odor
FLT 1153, JFK-PBI. STRONG ODOR EVENT DURING APPROACH PRESENT IN CABIN AND COCKPIT,. LASTED ABOUT 4 MINUTES. SMELLED LIKE CHEMICAL OR NAIL POLISH SCENT;…
- 12 Aug 2025
Smoke Detector, failed
FLT#1752, SJU-TPA. "LAV B SMOKE DETECTOR INTERMITTENTLY GOING OFF; REMOVED AND REPLACED LAV F SMOKE DETECTOR IAW AMM 26-17-15. CHECKS OK."
- 13 Oct 2024
Unknown, odor
FLT#365,BOS-RSW. (AIRCRAFT DIVERTED TO RIC). 'DIVERSION DUE TO CABIN CREW SYMPTOMS RELATED TO ODOR EVENT.' (SUPPLEMENTAL INFORMATION TO FOLLOW)
- 16 Sep 2024
Fuel Filter, clogged
FLT#2420, AUA-EWR. 'AFTER TO AT 4000' ECAM ENG2 FUEL FILTER CLOG DISPLAYED. ACCOMPLISHED QRH ACTIONS. CLOG MSG DISAPPEARED AFTER 5 MINUTES; REMOVED AND…
- 5 Sep 2024
Unknown, odor
FLT#1567, HPN-PBI. 'CREWMEMBERS SMELLED DIRTY SOCKS ON DESCENT AND LANDING; COMPLIED ITH INFORMATION NOTICE 2017-T015, SECTION B2 CREW REPORTED FLEW THROUGH…
- 1 Aug 2024
Post, cracked
DURING CURRENT CHECK, AEM REPORTED CRACKS ON THE WINDSHIELD FRAMING CENTER POST LOWER ATTACHMENT ON BOTH SIDES OF AREAS C & D. DAMAGE REMOVED BY FOLLOWING…
- 1 Aug 2024
Skin, corroded
REPORTED MULTIPLE (7) SPOTS OF CORROSION ON THE INNER SKIN OF THE FWD FUSELAGE BETWEEN FR 33-34 & STR 41L-40R IN THE FWD CARGO COMPARTMENT. THE CORROSION WAS…
- 1 Aug 2024
Web, corroded
DURING HEAVY MAINTENANCE: CORROSION ON SUPPORT WEB LOCATED BTW FR. 69 AND FR 70 AT LEVEL STR 23L AT AFT GALLEY AREA (CPCP FINDING); REF AEROMAN WO 2024 208/1…
- 1 Aug 2024
Support, corroded
DURING HEAVY MAINTENANCE: CORROSIONS ON LOWER SILL LOCATED AT FR 68 AT LEVEL STR 23R AT AFT GA LLEY AREA (CPCP FINDING); REF AEROMAN WO 2024 208/1 NR…
- 1 Aug 2024
Support, corroded
DURING HEAVY MAINTENANCE: CORROSIONS ON LOWER SILL LOCATED BTW FR 66 AND FR 68 AT LEVEL STR 23L AT AFT GALLEY AREA (CPCP FINDING); REF AEROMAN WO 2024 208/1…
- 1 Aug 2024
Window Post, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON WINDSHIELD CENTRAL LOWER NODE RH SIDE. CRACK LENGTH 0.125 INCH AND DIRECTION 7 OCLOCK; (RESOLVED ON W/O:…
- 1 Aug 2024
Window Post, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON WINDSHIELD CENTRAL LOWER NODE LH SIDE. CRACK LENGTH 0.5 IN AND DIRECTION 5 OCLOCK; (RESOLVED ON W/O:…
- 1 Aug 2024
Skin, dented
DURING HEAVY MAINTENANCE: DENT EXTERNAL SKIN BTW FR 27 TO FR 28 AND BTW STR 30L TO STR 31L AT L OWER FUSELAGE;(RESOLVED ON W/O: 1275940 TASKCARD: NR-00005)…
- 1 Aug 2024
Skin, dented
DURING HEAVY MAINTENANCE: DENT EXTERNAL SKIN LOC.FR13 TO FR14 AND 3.500 INCH LOWER OF LH SIDE ST R AT LOWER FUSELAGE; (RESOLVED ON W/O: 1275940 TASKCARD:…
- 9 Mar 2024
A/C Pack, odor
FLT#427, JFK-GCM. 'RA'S REPORT DIRTY SOCKS SMELL ON FINAL; COMPLIED WITH INFO NOTICE 2017-T015 SECTION B1 LEVEL A DECONTAMINATION ACCOMPLISHED ON PACK #2 WITH…
- 5 Jan 2024
Unknown, unknown
FLT#1267, HPN-PBI. 'DURING CRUISE- INFLIGHT REPORTED A NOISE OR VIBRATION FROM LEFT SIDE MID-WING. SLOWED TO .77 MACH AND NOISE DISSAPPEARED. INOP SPOILER…
- 27 Jan 2023
Sense Line, cracked
FLT#41, FLLL-MDE. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) 'AIR ENG 2 BLEED FAULT ON CLIMB OUT (HI-TEMP 275 C); UPON INSPECTION FOUND SENSE LINE TO FAN…
- 15 Dec 2022
A/C Pack, odor
FLT#8351, BOS-MCO. 'MODERATE OILY ODOR IN FLIGHT DECK. WHEN APU BLEEDS ON AND DURING DESCENT AFTER 18,000 FEET NAUSEATING.' PER 320 TSM 05-50-00-810-831-A…
- 28 Oct 2022
None, none
FLT#1826, SAT-JFK. (AIRCRAFT DECLARED AN EMERGENCY INTO JFK) 'HYDRAULIC GREEN LOW-LEVEL RESERVOIR ECAM DURING CRUISE INDICATION WAS IN THE LOW AMBER RANGE…
- 24 Oct 2022
Fmu, failed
FLT#2519, LGA-MSY. ' ( PACKS ) DIRTY SOCK SMELL 5TH WRITE UP FOR THIS A/C; ACCOMPLISHED W/O 1210656 TSI 43569-1 ODOR EVENT T/S AND CORRECTIONS REF LPS…
- 21 Oct 2022
O-Ring, leaking
FLT#2119, ORH-FLL. 'INTERMITTENT ODOR THROUGHOUT CABIN & COCKPIT ON APPROACH TO FLL ( APU SYSTEM ). REPLACED THE FCU/LUBE PUMP O-RING FOR THE APU REF.AMM…
- 4 Oct 2022
None, none
FLT#80, RNO-JFK. 'AT TOP OF DESCENT / IN DESCENT AT FL270 TO 10,000 FT HP VALVES OPEN WE HAD FUMES / DIRTY SOCK / OILY SMELL. WHEN HP CLOSED IT SEEMED TO…
- 25 Sep 2022
None, failed
FLT#373, BOS-AUA. '(AIRCRAFT PERFORMED AN AIR TURN BACK TO BOS) ' MCDU 1 BLANK ON CLIMBOUT AT FL 200. THE COMPUTER RESET PROCEDURE WOULD NOT FIX MCDU1;…
- 31 Aug 2022
None, none
FLT#679, JFK-MKE. 'ON DESCENT. THROUGH 10,000 FEET FLIGHT ATTENDANTS SUSPECTED A FUME EVENT; ACCOMPLISHED INFO NOTICE 2017-T015I. TROUBLESHOOT TO APU BLEED.…
- 26 Aug 2022
Skin Panel, corroded
DURING HEAVY MAINTENANCE: TRANSFERRED FROM 3451484-1 FOUND CORROSION ON AFT LAV VENT SKIN PANEL; REF FLIGHTSTAR WO FS220050 N/R 00004 REPAIRED FUSE SKIN AT…
- 13 Jun 2022
None, none
DURING HEAVY MAINTENACE, WINGS / LH WING / TOP SKIN PANEL 2 / TRAILING EDGE OVERHANG / LOWER SURFACE / OJR – WX4392.633 / CORROSION AT PREVIOUS REPAIRED AREA…
- 13 Jun 2022
None, none
DURING HEAVY MAINTENANCE, CORROSION REAR SPAR TOP SKIN OVERHANG LOWER SURFACE BETWEEN RIB 7A TO RIB 8 ON LH WING; REF AEROMAN WO 2022-163/1, NR 2022-285006;…
- 4 Sep 2021
Battery, failed
FLT 225, JFK-TPA. EMERG LIGHT BATTERY FIN 13WL FAILED TEST; R & R EMERG LIGHT BATTERY FIN 13WL IAW AMM 33-51-38
- 23 Jul 2021
Interface Unit, failed
FLT # 414, SEA-FLL. AFT CARGO DOOR OPEN FOR CARGO DOOR OPEN NOSE GEAR DOOR OPEN ALL OPENED IN FLIGHT ; REMOVED AND REPLACED LGCIU'S 1&2 IAW AMM…
- 23 Jul 2021
Interface Unit, failed
FLT # 414, SEA-FLL. AFT CARGO DOOR OPEN FOR CARGO DOOR OPEN NOSE GEAR DOOR OPEN ALL OPENED IN FLIGHT ; REMOVED AND REPLACED LGCIU'S 1&2 IAW AMM…
- 25 Jun 2021
Unknown, odor
FLT 1168, PBI-HPN. CABIN FUMES/ODOR EVENT IN AFT CABIN AND AFT GALLEY. DESCRIBED AS A COMBINATION OF DIRTY SOCKS AND MUSTY. FIRST OCCURENCE WAS AT THE START…
- 24 Mar 2021
Chime, inoperative
FLT 1670, FLL-BOS. DURING FLT FA NEVER RECEIVED THE DOUBLE DING ADVISORY CHIME PASSING 10 K IN BOTH CLIND AND DESENT FROM CYCLING NO SMOKING SWITCH ; DURING…
- 17 Dec 2020
Unknown, odor
FLT 1033, MCO-SJU. LEVEL 1 ODOR IN FLIGHT DECK AND CABIN PASSING 10,000 FT WITH IDLE POWER. NOTICED BY CABIN CREW CUSTOMER MORE PREVALENT IN FRONT OF…
- 17 Dec 2020
Filter, failed
FLT 1052, SJU-TPA. PASSING THROUGH 10000', A PUNGENT ODOR WAS PRESENT IN THE COCKPIT. THE SMELL WAS A SLIGHT WET SOCK SMELL, WITH A BIT OF SENSE OF AN…
- 17 Dec 2020
Filter, failed
FLT 1052, SJU-TPA. PASSING THROUGH 10000', A PUNGENT ODOR WAS PRESENT IN THE COCKPIT. THE SMELL WAS A SLIGHT WET SOCK SMELL, WITH A BIT OF SENSE OF AN…
- 12 Dec 2020
Hydraulic System, leaking
FLT 2427, EWR-MCO. ODOR IN COCKPIT ON DESCENT 6000' TO 2000'. COMPLIED WITH WO 1088341 CABIN ODOR T/S GURULINES. ENGINES 1-2 INSPECTION, NO FINDINGS. FURTHER…
- 10 Dec 2020
Apu, odor
FLT 2416, AUS-MCO. STRONG ODOR IN COCKPIT ONLY ON FINAL APPROACH. APU SYSTEM. C/W INFO NOTICE-2017-T015F SECT C TABLE 1. VERIFIED OIL SMELL WITH APU BLEED…
- 1 Dec 2020
Eec, failed
FLT 942, LAX-RNO. DURING CLIMB OUT OF LAX ENGINE 1 ROLLED BACK TO NEAR IDLE. THEN RETURNED TO CLIMB POWER. AFTER LANDING ECAM, ENGINE 1 OVERSPEED PROT FAULT,…
- 15 May 2020
Web, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION BELLY FAIRING WEB FASTENER COMMON TO THE TI -ANGLE LOCATED FR41-42 RH SIDE; (REF AEROMAN NR 168606 WO 2020 156/1)…
- 15 May 2020
Connector, corroded
DURING HEAVY MAINTENANCE, CORROSION PAX CREW DOOR 842 ELECTRICAL CONNECTOR OF ESCAPE SLIDE; (REF AEROMAN NR 168623 WO 2020 156/1) R & R ESCAPE SLIDE RAFT CREW…
- 24 Jul 2019
Controller, failed
FLT 1499, FLL-HAV. RETURNED TO FIELD. AFTER TAKE OFF CAB PR SYSTEM 1 AND 2 FAULT; R & R PRESS CONT# 1 (11HL) IAW TSM 21-31-00-810-827-A AND IAW AMM 21-31-34.…
- 10 Nov 2018
Battery Pack, failed
FT # 466, RSW-BOS. EMER EXIT LIGHTS IN CABIN (ALL) REMAIN ON FOR FLIGHT UNABLE TO RESET; REMOVED AND REPLACED AFT AND RH OVER WING EMER EXIT, EMER LIGHT…
- 10 Nov 2018
Battery Pack, failed
FT # 466, RSW-BOS. EMER EXIT LIGHTS IN CABIN (ALL) REMAIN ON FOR FLIGHT UNABLE TO RESET; REMOVED AND REPLACED AFT AND RH OVER WING EMER EXIT, EMER LIGHT…
- 10 Nov 2018
Switch, failed
FT # 466, RSW-BOS. HAD BATTERIES TO EMER EXIT LIGHTS CHANGED, THINGS WORKED. HAD ON PWR TRANSFER FROM EXTERNAL POWER TO APU, ALL EXIT LIGHTS CAME ON AND…
- 14 Sep 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 31 AND BTW STR 40R TO STR 41R IN FWD CARGO COMPARTMENT; REPLACED SHEAR TIE FR 31 AND BTW…
- 14 Sep 2018
Crossbeam, cracked
DURING HEAVY MAINTENANCE, CRACKS WERE FOUND. REFER TO EC A16-697--01. FUSELAGE/ NOSE FWD FUSELAGE/ FR 16 LT/RT & FR 20 LT/RT CROSSBEAM/ CRACKS FOUND FR 16 RT/…
- 14 Sep 2018
Epsu, failed
DURING HEAVY MAINTENANCE, EPSU 12WL FAILED TEST. REPLACED EPSU 12WL. OPS CHECK GOOD IAW AMM 33-51-38-000-001-A AND 33-51-38-400-001-A.
- 14 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM + Y 254 AT FRAME 16 AT FWD GALLEY AREA; PERFORMED REPAIR LOC FLOORBEAM + Y 254 AT FWD GALLEY…
- 14 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM + Y 254 AT FRAME 16 AT FWD GALLEY AREA; PERFORMED REPAIR LOC. FLOORBEAM + Y 254 AT FWD GALLEY…
- 14 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM + 503 AT FRAME 16 AT FWD GALLEY AREA; REPLACED FLOORBEAM + 503.2 AT FRAME 16 AT FWD GALLEY…
- 14 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM +Y 1292 AT FRAME 16 AT FWD GALLEY AREA; REPLACED FLOORBEAM + Y1292 AT FR 12 TO FR 24 AT FWD…
- 14 Sep 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM +Y 1292 AT FRAME 16 AT FWD GALLEY AREA; REPLACED FLOORBEAM + Y 1292 AT FR 12 TO FR 24 AT FWD…
- 14 Sep 2018
Dummy Rail, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RAIL DUMMY -Y 81 AT FR 16 AT FWD GALLEY AREA; REPLACED RAIL DUMMY -Y 81 LOCATED BTW FR 12 TO FR 16 AT…
- 14 Sep 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL FROM FR60 TO FR62 AND STR 38R IN AFT CARGO COMPARTMENT; PERFORMED REPAIR ON LOWER SILL FROM…
- 14 Sep 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL FROM FR60 TO FR62 AND STR38R IN AFT CARGO COMPARTMENT; PERFORMED REPAIR ON LOWER SILL FROM…
- 14 Sep 2018
Stringer, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON STRINGER LOCATED BTW FR 58 TO FR 59 AT STRINGER 42L IN AFT CARGO; PERFORMED REPAIR ON STR 42L BTW FR 58…
- 14 Sep 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL FROM FR60 TO FR62 AND STR 38R; PERFORMED REPAIR ON LOWER SILL LOCATION BETWEEN FR60 TO FR61…
- 14 Sep 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 30 AND BTW STR 41R TO STR 42R IN FWD CARGO COMPARTMENT; REPLACED SHEAR TIE FR 30 AND BTW…
- 14 Sep 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 32 AND BTW STR 41L TO STR 42L IN FWD CARGO; REPLACED SHEAR TIE FR 32 AND BTW STR 41L TO STR…
- 14 Sep 2018
Shear Tie, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SHEAR TIE FR 28 AND BTW STR 43L TO STR 44L IN FWD CARGO COMPARTMENT; REPLACED SHEAR TIE FR 28 AND BTW…
- 14 Sep 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SEAT TRACK + Y765 FRAME 62 + 10" IN PASSENGER CABIN; REPLACED SEAT TRACK + Y765 LOCATED BTW FR 47 TO FR…
- 14 Sep 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SEAT TRACK + Y765 FRAME 62 + 10 " IN PASSENGER CABIN; REPLACED SEAT TRACK + Y765 LOCATED BTW FR 47 TO FR…
- 12 Jun 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON L2 PAX DOOR SILL FR 68 STR 23L HAS 4 EA FITTING HOLES; REMOVED CORROSION L2 PAX DOOR SILL FR 68 STR 23L…
- 12 Jun 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 PAX DOOR SILL FR 66 STR 23R HAS 3 EA FASTENER HOLES; REMOVED CORROSION ON R2 DOOR SILL FR 66 STR 23R…
- 12 Jun 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 DOOR SILL FR 66NSTRN23R HAS 3 EA FASTENER HOLES; REMOVED CORROSION ON R2 PAX DOOR SILL FR 66 STR 23R…
- 12 Jun 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 DOOR SILL FR 66NSTRN23R HAS 3 EA FASTENER HOLES; REMOVED CORROSION ON R2 PAX DOOR SILL FR 66 STR 23R…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN - Y1292 FLOORBEAM FRAME 68 STR 23R; BLENDED AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN -Y1292 FLOORBEAM FRAME 68 STR 23R; BLENDED AND CHECKED LIMITS. FOUND TO BE OUT OF LIMITS IAW…
- 12 Jun 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BULK DOOR SILL FRAME 62 STR 38R; REMOVED CORROSION ON BULK CARGO DOOR FR 62 STR 38R VERIFIED BEYOND…
- 12 Jun 2018
Dummy Rail, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE DUMMY RAIL Y-189 AT FR20+3; REMOVED AND REPLACED DUMMY RAIL AT Y189 FR20=3 IAW…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y464 FLOORBEAM FRAME 64+11 STR 23L; REMOVED AND REPLACED AFT CABIN Y464 FLOORBEAM IAW SRM…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y765 FLOORBEAM FRAME 68 STR 23R; REMOVED AND REPLACED AFT CABIN FLOORBEAM Y765 FR68 STR 23R…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y765 FLOORBEAM FRAME 68 STR 23L; REMOVED AND REPLACED AFT CABIN Y765 FLOORBEAM FRAME 68 STR…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y464 FLOORBEAM FRAME 68 STR 23R; REMOVED AND REPLACED AFT CABIN FLOORBEAM FRAME 68 STR 23R IAW…
- 12 Jun 2018
Dummy Rail, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN DUMMY RAIL O/O OF Y254 FRAME 66 STR 23R; REMOVED CORROSION ON AFT CABIN DUMMY RAIL O/B Y254…
- 12 Jun 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE SEAT TRACK Y765 FR 16 STR 23L; REMOVED CORROSION ON CABIN SEAT TRACK Y765 FR 16…
- 12 Jun 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE SEAT TRACK Y1292 FR 20 STR 23R; REMOVED CORROSION ON CABIN SEAT TRACK Y1292 FR…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y765B FLOORBEAM FRAME 66 STR 23L; REMOVED AND REPLACED AFT CABIN Y765 FLOORBEAM FRAME 66 STR…
- 12 Jun 2018
Door Sill, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 PAX DOOR SILL FR 66 STR 23R OB SIDE 2EA HASTENER HOLES; R2 DOOR SILL OUT OF LIMITS IAW SRM…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE FLOORBEAM Y1292 FR 68 STR 23L; REMOVED CORROSION ON CABIN FLOORBEAM Y1292 FR 68…
- 12 Jun 2018
Seat Track, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE SEAT TRACK Y-254 FR 18 +6" STR 23R; REMOVED CORROSION ON CABIN SEAT TRACK Y-254 FR…
- 12 Jun 2018
Panel, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE RT WEB PANEL AT FR20; BLENDED FOUND MATERIAL LOSS OUT OF LIMITS REMOVED AND…
- 12 Jun 2018
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM Y-765 FR66 STR 23R; REMOVED AND REPLACED FLOORBEAM Y-765 FR66 STR23R IAW SRM…
- 25 May 2018
Unknown, odor
DURING DECENT, FLT CREW WERE INFORMED BY FA1 THAT THEY SMELLED A SLIGHT MUSTY ODOR. NO ODOR DETECTED IN COCKPIT. AIRCRAFT IS OK FOR SERVICE.
- 25 Jan 2018
Unknown, odor
DURING DESCENT FA DETECTED AN ACRID BURNING ODOR IN THE ACFT. FLICKERING LIGHTS. MOSTLY DISSIPATED, LINGERED LONGER IN AFT CABIN. PERFORMED TSM…
- 8 Jan 2018
Proximity Sensor, failed
LANDING GEAR WOULD NOT EXTEND. RECYCLED, THEN USED THE MANUAL EXTENSION. DURING GEAR SWING, ON RETRACTION, THE NOSE GEAR DOORS STAYED AMBER. FOUND THE RELAY…
- 7 Jan 2018
Control Unit, failed
LGCIU DISAGREE, FOLLOWED ECAM AND RECYCLED THE LANDING GEAR NO RESULT. MANUAL GEAR EXTENSION REQUIRED. TROUBLESHOT TO THE NR 1 LGCIU. R & R THE NR 1 LGCIU.…
- 13 Dec 2017
Battery Pack, failed
FT # 225, JFK-TPA. EMER LIGHT FAILS TEST; R & R EPSU BATTERIES AT 11WL AND 12WL OPS AND BITE CKS GOOD. IAW AMM 33-51-38.
- 13 Dec 2017
Battery Pack, no test
FT # 225, JFK-TPA. EMER LIGHT FAILS TEST; R & R EPSU BATTERIES AT 11WL AND 12WL OPS AND BITE CKS GOOD. IAW AMM 33-51-38.
- 16 Oct 2016
Shear Plate, corroded
DURING MAINTENANCE, CORROSION WAS DISCOVERED ON RT SHEAR PLATE FR 69 +5". REMOVED AND REPLACED RT SHEAR PLATE AT FR69-FR70 IAW SRM 51-72-11.
- 16 Oct 2016
Floorbeam, corroded
DURING MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN RT SIDE FLOORBEAM -Y765 AT FR68. REMOVED AND REPLACED RT SIDE FLOORBEAM -Y765 AT AFT CABIN FR68 IAW…
- 16 Oct 2016
Floorbeam, corroded
DURING MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN LT SIDE FLOORBEAM -Y765 AT FR68. REMOVED AND REPLACED LT SIDE FLOORBEAM -Y765 AT AFT CABIN FR68 IAW…
- 16 Oct 2016
Floorbeam, corroded
DURING MAINTENANCE, CORROSION WAS DISCOVERED ON MAIN CABIN FLOORBEAM +Y1292 FR 64 TO FR 66. REMOVED AND REPLACED FLOORBEAM AT +1292 FR 64 TO FR 66 IAW SRM…
- 16 Oct 2016
Floorbeam, corroded
DURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM +Y1292 AT FR 67+13. REMOVED AND REPLACED FLOORBEAM AT FR66 +4 TO FR 67+13 IAW SRM 51-72-11.
- 16 Oct 2016
Floorbeam, corroded
DURING MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOORBEAM -Y1292 AT FR 66 TO FR 68. REMOVED AND REPLACED FLOORBEAM AT -Y1292 FROM FR 68 TO FR 68 IAW SRM…
- 16 Oct 2016
Floorbeam, corroded
DURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM-Y1292 AT FR 67+2. REMOVED AND REPLACED FLOORBEAM AT FR 67 -Y1292 IAW SRM 51-72-11.
- 24 May 2016
Control Valve, failed
FOUR HOURS INTO FLIGHT, A BURNED ODOR WAS NOTICED AND PACK 1 WAS SHUTDOWN. ODOR WENT AWAY. R & R FLOW CONTROL VALVE ON NR 1 PACK IAW AMM 21-51-51. LEAK CHECK…
- 31 Jan 2016
Wire Harness, damaged
EMERGENCY LIGHT AT 3 ABC INOPERATIVE. R & R LIGHT AND WIRING HARNESS ASSY FOR 3 ABC EMERGENCY FLOOR LIGHT.
- 26 Oct 2014
Battery Pack, failed
DURING A MAINTENANCE CHECK, FOUND RT EPSU BATTERY FAILED. R & R THE BATTERY PACK IAW AMM 33-51-38. OPS CHECKED GOOD.
- 13 Oct 2014
Battery, no test
EMERGENCY LIGHT TEST FAILED. R & R BATTERY ON LT FIN 11WL EMERGENCY POWER SUPPLY. LIGHT TESTED OK IAW AMM 33-51-38.
- 27 Sep 2012
Transmitter, failed
FLT 374 FLL-LGA, AIRCRAFT DIVERTED TO JFK DUE TO ANTI SKID/NWS FAULT DURING CLIMB. WOULD NOT RESET WITH NW STEER SWITCH. RESET ITSELF JUST BEFORE LANDING.…
- 27 May 2012
Roller, out of adjust
FLT 6856 LCQ-JFK, AIR TURNBACK DUE TO ON TAKEOFF NOSE GEAR UPLOCK REMAINED LIT. ADJUSTED NLG UPLOCK ROLLER IAW AMM 32-21-16-04. OPS CHECK IAW AMM…
- 20 Jan 2012
Servo Valve, failed
FLT 636 SFO-BOS WITH GEAR EXTENSION AUTOBRAKE FAULT STATUS MSG INDICATED. AUTO AND NORMAL BRAKES INOP. RESET ANTISKID SWITCH OPS NORMAL. REMOVED AND REPLACED…
- 23 Jun 2008
Battery Pack, discharged
ON MAINTENANCE INSP LT EMERGENCY EXIT EPSU BATTERY FAIL TEST, REMOVED AND REPLACED LT EMERGENCY EXIT EPSU BATTERY OPS CHECK NORMAL IAW 33-51-00. (K)
- 19 Nov 2007
Fan, burned out
FLT 411, BOS-SAN, APPROX BETWEEN 12:00Z-15:00Z, LOUD NOISE AND STRANGE/ELECTRICAL ODOR FOLLOWED BY BLOWER FAN FAULT, RAN ECAM SET BLOWER TO OVERRIDE-SOUND AND…
- 19 Nov 2007
Fan, burned out
FLT NR 411, BOS-SAN, APPROX BETWEEN 12:00Z-15:00Z, LOUD NOISE AND STRANGE/ELECTRICAL ODOR FOLLOWED BY BLOWER FAN FAULT, RAN ECAM SET BLOWER TO OVRD-SOUND AND…
- 2 Jun 2007
Unknown, odor
AFTER TAKEOFF, APPROX 2100 PM, JFK TO SJC, AIR TURNBACK DUE TO ODOR OF ELECTRICAL BURNING ODOR THROUGHOUT THE CABIN, SOME ODOR IN THE COCKPIT. PERFORMED TSM…
- 31 Dec 2006
Unknown, odor
SMELL ONLY NOTICED AROUND ROW 12 LIVE TV ELECTRONIC BOXES UNDER SEAT. LIVE TV MASTER SWITCH TURNED OFF WITH AFT AVIONICS ALSO TURNED OFF. SMELL SUBSIDED.…
- 12 Jun 2006
Video Display, malfunctioned
PREVIOUS CREW SMELLED BAD ODOR AROUND ROW 17 DURING CLEAN UP & A/C TURN. ACCOMPLISHED TSM TASK 23-39-00-810-801, FOUND 17C VDU WITH ODOR. REMOVED AND REPLACED…
- 24 Nov 2004
Position Sensor, failed
FLIGHT CONTROL FLAPS FAULT AT FLAPS 2 190 KNOTS. FLAPS DID NOT EXTEND TO POS 2. SLATS EXTENDED NORMALLY. FOLLOWED ECAM AND RECYCLED FLAPS, EXTENDED NORMAL.…
- 29 May 2004
Electrical Box, malfunctioned
BURNING SMELL IN CABIN AT ROW 11. COMPLIED WITH INFO NOTICE 2003-T050TR A. NO ABNORMALITY NOTED. AS A PRECAUTION REMOVED AND REPLACED SEB AT 10B AND 10E. RAN…
- 19 Jan 2004
Release Cable, binding
RT EMERGENCY EXIT RELEASE CABLE STIFF, CABLE DOES NOT EXTEND AS SOON AS THE LATCH PIN DISENGAGES FROM THE RELEASE LEVER WITH SPRING-LOADED TEST TOOL CONNECTED…
- 19 Jan 2004
Release Cable, binding
LT EMERGENCY EXIT RELEASE CABLE STIFF, CABLE DOES NOT EXTEND AS SOON AS THE LATCH PIN DISENGAGES FROM THE RELEASE LEVER WITH SPRING-LOADED TEST TOOL CONNECTED…
- 27 Apr 2003
Odor, detected
A LOW LEVEL INTERMITTENT ALARM HEARD DURING ROLL OUT 5-7 SEC, A STRONG ELECTRICAL ODOR. SHOWED CREW REGARDING THE COCKPIT DOOR ENTRANCE DEY PAD THAT IF A…