N553JB
2010 Robinson Helicopter Company R44 II standard FAA →
registration
- 2010
earlier registrations
1 past record
- 2002
service difficulty reports
5 reports
- 9 Feb 2006
Cable Assy, out of adjust
ON C-3 CHECK, LT EMERGENCY EXIT CABLE NOT PASSING TEST, TOO TIGHT. CABLE REMOVED AND INSTALLED AS PER AMM 25-62-43-04. ADJUSTMENT/RIGGING COMPLETED AS PER AMM…
- 9 Feb 2006
Cable, tight
ON C-3 CHECK, RT EMERGENCY EXIT CABLE NOT PASSING TEST. TOO TIGHT. CABLE REMOVED AND INSTALLED AS PER AMM 25-62-43-04. ADJUSTMENT /RIGGING COMPLETED AS PER…
- 15 Sep 2005
Electrical Box, failed
INFLT CREW REPORTED SMELL AROUND SEATS 24-25 A/C LEFT. TURNED LIVE TV OFF SMELL DISSIPATED. PERFORMED INFO NOTICE 2004-T023TR AND TSM 24-00-00. NO DEFECTS…
- 6 Jun 2004
Electrical Box, shorted
FLIGHT CREW REPORTED ODOR AT RIGHT MID CABIN. PERFORMED TSM TASK 24-00-00-810-823. FOUND PROBABLE CAUSE LTV SEAT ELECTRONIC BOX AT ROW 12 DEF. REMOVED AND…
- 27 Sep 2003
Connector, damaged
RAM AIR TURBINE AUTO-DEPLOY OPERATIONAL CHECK FAILED IAW JB WORK CARD 292000-05-1. FOUND PIN 7 ON 2224VC PUSHED IN, PULLED AND RECONNECTED. OPS CHECK GOOD.…