N550LL
1998 Aerospatiale ATR 72-212A standard FAA →
reservations
earlier registrations
1 past record
- 1998
service difficulty reports
55 reports
- 18 Dec 2011
Battery, inoperative
THE CREW REPORTED THAT AFTER TAKEOFF MAIN BATTERY CHARGE CONTACTOR FAULT, BATTERY CHARGE INDICATOR WAS SHOWING +50 DESELECTED MAIN BATT CHG IAW AOM 1 BATT…
- 12 Dec 2011
Light, intermittent
CREW REPORTED LAST FLOOR EMERGENCY LIGHT IN GALLEY AREA IS OUT. ACFT REMOVED FROM SERVICE. PERFORMED OPS CHECK OF EMERGENCY LIGHT AND FOUND ALL TO BE IN…
- 12 Dec 2011
Cover, missing
CREW REPORTED THE AFT EMERGENCY EXIT FLOOR LIGHT LOOSE, AND AFT EMERGENCY EXIT LIGHT MISSING CLEAR COVER. ACFT REMOVED FROM SERVICE. RESECURED AFT EMERGENCY…
- 2 Nov 2011
Powerpack, inoperative
FWD CABIN EMERGENCY LIGHTS NOT ILLUMINATING. R & R FWD CABIN EMERGENCY POWER PACK IAW W/C EX-335121-RAI-10010-007. OPS CHECK GOOD.
- 13 Sep 2011
Brake, weak
F/O BRAKES VERY WEAK IN SLOWING AIRPLANE DOWN. PEDALS BOTTOM OUT. PERFORMED BRAKE LOW PRESSURE LINE BLEEDING IAW 32-42-00 TAXI ACFT AND FOUND BRAKES WORKING…
- 1 Sep 2011
Bulb, burned out
EXTERIOR EMERGENCY EXIT LIGHT AT THE SERVICE DOOR IS INOPERATIVE. R & R LIGHT BULB AT SERVICE DOOR EMERGENCY EXIT EXTERIOR LIGHT AND PERFORMED OPS IAW W/C…
- 19 Aug 2011
Bulb, inoperative
FWD OVHD EXIT SIGN RT BULB IS OUT. RELAMPED EXIT SIGN ON FWD RT FROM BULB KIT IAW EX-335000-OPT-10000-002.
- 1 Jul 2011
Battery Pack, inoperative
EMERGENCY LIGHT SERVICE DOOR EXIT, INOPERATIVE. R & R EMERGENCY BATTERY PACK.
- 1 Jul 2011
Power Supply, inoperative
EMERGENCY LIGHT INOPERATIVE ON DOOR. REPLACED EMERGENCY LIGHT POWER SUPPLY.
- 31 Mar 2011
Wire, broken
PASSENGER ENTRY DOOR EMERGENCY LIGHT IS INOP. REPAIRED WIRE OPS CK GOOD IAW JIC 33-50-00.
- 8 Jun 2010
Battery Pack, inoperative
SEVERAL EMERGENCY LIGHTS IN CABIN (FLOOR,SIGNS,CEILING )WILL NOT STAY ON UNDER EMERGENCY BATTER POWER. R & R 61WL BATTERY PACK IAW MM EX 33-51-21, RAI…
- 8 Jun 2010
Battery Pack, inoperative
EMERGENCY LIGHT BATTERY PACK INOPERATIVE.
- 31 Mar 2010
Light, illuminated
AFTER BOTH ENGINES START F/A ADVISES EMERGENCY LIGHTS ILLUMINATE. AWAITING AML PAGE FOR FURTHER DETAILS.
- 31 Mar 2010
Switch, failed
AFTER BOTH ENGINES SHORT F/A ADVISES EMERGENCY LIGHT ILLUMINATE. RAI EMERGENCY LIGHT SELECTOR SWITCH IAW STD PRACTICES NR 20-27-17. OPS CHECK OK.
- 12 Nov 2009
Power Supply, inoperative
FWD EMERGENCY LIGHTS DO NOT STAY ILLUMINATED FOR MORE THAN 30 SECONDS. REMOVED AND REPLACED FWD EMERGENCY PWR SUPPLY AT POSITION NR 43WL IAW ATR JIC NR…
- 11 Nov 2009
Battery Pack, inoperative
WHEN TURNING THE EMERGENCY LIGHTS FROM F/A PANEL FWD INTERIOR/EXTERIOR LIGHTS WILL MOMENTARLY WORK TURN OFF. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT…
- 11 Nov 2009
Power Supply, failed
WHEN TURNING THE EMERGENCY LIGHTS FROM F/A PANEL THE FWD INTERIOR/ EXTERIOR LIGHTS WILL MOMENTARLY WORK TURN OFF. REMOVED AND REPLACED EMERGENCY PWR SUPPLY…
- 11 Nov 2009
Power Supply, failed
FWD EMERGENCY LIGHTS DO NOT STAY ILLUMINATED FOR MORE THAN 30 SECONDS. REMOVED AND REPLACED FWD EMERGENCY POWER SUPPLY AT POSITION NR 43WL IAW JIC NR33-51-21,…
- 10 Oct 2009
Warning Light, false activation
BOTH GEAR INDICATIONS SHOWED UNSAFE GEAR AFTER RETRACTION. EMERGENCY DECLARED. SYSTEM DEFERRED ON MEL NR 32-03 AUTH NR 100070. MEL RESTORED ON 10-11-09 AT…
- 30 Sep 2009
Engine, power loss
CAPT INFORMED DISPATCH DURING CLIMB, LT ENG TORQUE DROPPED TO 60 PERCENT AND DURING RETURN TO BASE HAD FIRE WARNING. EMERGENCY DECLARED. AWAITING AML PAGE FOR…
- 30 Sep 2009
Fuel Nozzle, leaking
DFW ACFT 5 MIN INTO THE FLIGHT NOTICED NR 1 TQ (BOTH) INDICATIONS AROUND 60 PERCENT. MOVED POWER LEVER WITH NO EFFECT UNTIL THE LOW POWER ANGLE. WHEN…
- 23 Nov 2007
Battery Pack, inoperative
AFTER ENGINE START, TESTED EMERGENCY LIGHT/CAPT REPORTED HALF OF SYSTEM NOT ILLUMINATING. REMOVED AND REPLACED BATTERY PACK AT EMERGENCY LIGHT POWER SUPPLY…
- 12 Oct 2007
Lamp, inoperative
EMERGENCY FLOOR LIGHTS AT GALLEY AREA INOPERATIVE. REMOVED AND REPLACED LAMPS IAW JIC NR 33-50-00 AND FOUND WORKING PROPERLY.
- 21 Jul 2007
Unknown, odor
F/A REPORTED BURNING ODOR AROUND AFT GALLEY AREA AS A/C PARKED. ODOR DISSIPATED WHEN CABIN DOOR OPENED. PERFORMED DVI OF ALL LIGHTS IN THE BACK OF THE A/C FOR…
- 11 Jul 2007
Battery Pack, inoperative
WITH BATTERY POWER OFF, EMERGENCY EXIT LIGHT INOPERATIVE AT FWD OVERHEAD AND WINDOW EXIT LIGHT. REMOVED AND REPLACED EMERGENCY BATTERY PACK AT 43WL IAW JIC…
- 1 Oct 2006
Eec, surges
EN ROUTE AT 5,000 MSL, NR 2 ENGINE EXPERIENCED LARGE POWER SURGES. RT TQ WAS BETWEEN 50-102.5 PERCENT ON DIGITAL INDICATOR. POWER WAS REDUCED BELOW THE…
- 15 Sep 2006
Eec, defective
FLT 5100 - EIS-SJU - WHILE IN TAXIING, NR 2 ENGINE UNCOMMANDED FEATHER 3 TIMES. NO EEC FAILURE, NP DROPPED 40 PERCENT AND TQ TO 0 PERCENT. VERIFIED NR 2…
- 12 Sep 2006
Acm, burned
FLT 5195 - ANU-SJU - DURING CLIMB, STRONG BURNING ODOR NOTED WHEN LT BLEED WAS SELECTED ON. APPEARS TO BE THE PACK SYSTEM. (M)
- 23 Jul 2006
Sensor, defective
WHILE IN CLIMB, NR 2 ENGINE TQ FLUX OF 10 PERCENT AT 1,000 FTS, AFTER TAKEOFF INCREASE 20-30 PERCENT. RETURNED TO AIRPORT AND IN FINAL WENT TO 0 PERCENT THEN…
- 30 Oct 2005
Connector, dirty
DURING CLIMBOUT, THE RT ENGINE HAD A TORQUE FLUCTUATION OF 10-20 PERCENT. CREW PERFORMED A PRECAUTIONARY SHUTDOWN AND RETURNED. CLEANED TORQUE SENSOR…
- 2 Jul 2002
Battery Pack, discharged
MIA - DUIRNG SCHEDULED PS CHECK, MAINTENANCE REPORTED VERBAL FROM A PILOT, THE EMERGENCY BATTERIES (EMERGENCY LIGHTS) WERE DEAD. MAINTENANCE REMOVED AND…
- 26 Apr 2002
Power Supply, discharged
MIA - FLT 5021 - CREW REPORTED CABIN INTERIOR EMERGENCY LIGHTING TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFT POWER SUPPLY UNIT IAW ATR MM.…
- 18 Feb 2002
Seat Track, corroded
SAW - DURING CPCP4 INSPECTION, CORROSION WAS FOUND ON THE FOLLOWING SEAT TRACKS, LEFT FORWARD OUTBOARD, LEFT AFT OUTBOARD, AND LEFT AFT INBOARD. THE SEAT…
- 18 Feb 2002
Floorbeam, corroded
SAW - DURING CPCP4 INSPECTION, CORROSION WAS FOUND ON FLOORBEAM 39. THE FLOORBEAM WAS REMOVED AND REPLACED IAW ATR 72 SRM 51-25-01. THE AIRCRAFT WAS RETURNED…
- 30 Jan 2002
Floorbeam, corroded
SAW - DURING MBV INSPECTION, MAINTENANCE FOUND CORROSION AROUND NUT PLATE HOLES ON FLOORBEAM 36. MAINTENANCE REPLACED FLOORBEAM 36 IAW ATR SRM 51-25-01 AND…
- 30 Jan 2002
Floorbeam, corroded
MBV - DURING MBV INSPECTION MAINTENANCE, FOUND CORROSION AROUND NUT PLATE HOLES ON FLOORBEAM 40. MAINTENANCE REPLACED FLOORBEAM 40 IAW ATR SRM 51-25-01. (M)
- 30 Jan 2002
Floorbeam, corroded
SAW - DURING MBV INSPECTION MAINTENANCE, FOUND CORROSION AROUND NUT PLATE HOLES ON FLOORBEAM 38. MAINTENANCE REPLACED FLOORBEAM 38 IAW ATR SRM 51-25-01. (M)
- 30 Jan 2002
Support, corroded
MBV - DURING MBV INSPECTION MAINTENANCE, FOUND CORROSION ON THE LEFT Z MEMBER INBOARD OF PASSENGER DOOR SPRING. MAINTENANCE REMOVED AND REPLACED THE Z-MEMBER…
- 30 Jan 2002
Support, corroded
MBV - DURING MBV INSPECTION MAINTENANCE, FOUND CORROSION ON THE RIGHT Z-MEMBER JUST FORWARD OF SERVICE DOOR. MAINTENANCE REMOVED AND REPLACED THE Z-MEMBER IAW…
- 30 Jan 2002
Bracket, corroded
SAW - DURING MBV INSPECTION MAINTENANCE, FOUND CORROSION ON THE PASSENGER DOOR SILL PLATE FORK AND AFT BRACKETS. MAINTENANCE REMOVED AND REPLACED THE FORK…
- 28 Sep 2001
Battery Pack, discharged
DFW - FLT 3620 - MAINTENANCE FOUND TWO FORWARD FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY POWER PACK AT LOCATION 46WL. (M)
- 3 Sep 2001
Light, inoperative
DFW - FLT 3656 - EMERGENCY FLOOR LIGHTING AT SEAT 6A INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT LAMP AT SEAT 6A. OPERATIONALLY CHECKED GOOD. (M)
- 22 Aug 2001
Battery Pack, discharged
DFW - FOUND SEVERAL FLOOR PROXIMITY LIGHTS AND EXIT SIGN LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AT POWER SUPPLY UNIT 43WL IAW ATR MM.…
- 22 Jun 2001
Battery Pack, inoperative
DFW - FOUND EMERGENCY LIGHT ON PASSENGER DOOR INOPERATIVE. REMOVED AND REPLACED BATTERY PACK IAW AMM. OPS CHECK GOOD. (M)
- 4 Jun 2001
Flashlight, inoperative
DFW - FLT 3551 - AFT CABIN EMERGENCY FLASHLIGHT INOPERATIVE. ISSUED MEL. REMOVED AND REPLACED FLASHLIGHT IAW AMM. OPS CHECK GOOD. (M)
- 4 Jun 2001
Light, corroded
DFW - FLT 3737 - EMERGENCY EXIT FLOOR LIGHTS INOPERATIVE. FOUND PAX DOOR EMERGENCY LIGHT ASSEMBLY CORRODED. REMOVED AND REPLACED PAX DOOR EMERGENCY LIGHT ASSY…
- 17 May 2001
Fan, odor
FLIGHT ATTENDANT REPORTED THE SMELL OF BURNING INSULATION AROUND ROW EIGHT IN THE CABIN. THE SOURCE OF THE SMELL WAS DETERMINED TO BE FROM THE NR 2…
- 9 May 2001
Light, malfunctioned
DFW - FLT 3709 - CREW REPORTED MULTIPLE FLOOR PROXIMITY LIGHTS INOPERATIVE IN FORWARD CABIN. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY. OPERATIONAL CHECK…
- 25 Apr 2001
Battery Pack, discharged
JAN - FLT 3578 - CREW REPORTED SEVERAL EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY BATTERY PACK AT POWER SUPPLY UNIT…
- 21 Jun 2000
Seat Track, corroded
SAW - DURING MBV-2 INSPECTION, MAINTENANCE FOUND THE LEFT FLIGHT ATTENDANT SEAT TRACK CORRODED. MAINTENANCE REMOVED AND REPLACED SEAT TRACK IAW ENGINEERING…
- 16 Jun 2000
Pitot Tube, blocked
FLT 3709 - DFW - ON TAKEOFF AFTER POWER SET, ADU FAILED AND NO AIRSPEED INDICATION ON CAPT SIDE. AIRSPEED INDICATION WITH NO RED FLAGS. CLEARED BLOCKAGE IN…
- 12 Mar 2000
Relay, inoperative
DFW - FLT 3753 - EMERGENCY LIGHTS ON FLIGHT ATTENDANT PANEL CAME ON DURING TAXI. REMOVED AND REPLACED RELAY 12LE. OPS CHECK GOOD. (M)
- 28 Jun 1999
Panel, failed
DFW - FLT 3505 - ADVISORY DISPLAY UNIT SCREEN WENT BLANK AFTER TAKEOFF FOLLOWED BY ELECTRICAL SMELL IN THE COCKPIT AND CABIN. REMOVED AND REPLACED ADU. ALSO,…
- 28 Jun 1999
Adu, failed
DFW - FLT 3505 - ADVISORY DISPLAY UNIT SCREEN WENT BLANK AFTER TAKEOFF FOLLOWED BY ELECTRICAL SMELL IN THE COCKPIT AND CABIN. REMOVED AND REPLACED ADU. ALSO,…
- 12 Apr 1999
Battery Pack, disdcharged
SAW - DURING PS-2 INSPECTION, FOUND THE LEFT FORWARD CABIN EMERGENCY LIGHT BATTERY PACK DISCHARGED. REMOVED AND REPLACED THE BATTERY PACK AND OPERATIONAL…