N542UA
Gteex Revolution INDEPENDENCE 19 FAA →
registration
earlier registrations
1 past record
- 1991
service difficulty reports
85 reports
- 17 Jan 2013
Skin, dented
BS 756 AND STR 16L SKIN DENTED, REPAIRED IAW REO G11931 REV A AND EVA 70040.
- 17 Jan 2013
Frame, dented
UPPER LEG OF FUSELAGE FRAME BS 540, LBL 36 DENTED. TRIMMED OUT DAMAGE TO FRAME INNER FLANGE AND REMOVED PRODUCTION SPLICE, FABRICATED REPAIR ANGLE AND…
- 9 Oct 2011
Squib, missing
SQUIB LT ASSY MISSING FOR L EMER ESCAPE SLIDE. REPLACED CAP ASSY FOR LEFT EMERGENCY ESCAPE SLIDE, TESTS OK.
- 22 Aug 2011
Girt Bar, obstructed
DOOR 4R UNABLE TO CONFIRM DISARMED. CLEARED PLASTIC BOTTLE CAP WEDGED IN GIRT BAR. SYSTEM OP CHECK OK.
- 30 Jul 2011
Cover, unsecure
EMERGENCY EXIT LIGHT STRIP EXPOSED DOOR 2L. PLASTIC COVER DAMAGED, COVER SECURED WITH TAPE AND EEL LIGHTS WORK AT ALL LOCATIONS NEEDS NEW COVER. PLEASE REPAIR…
- 17 Jul 2011
Fan Blade, damaged
DURING WALK AROUND CREW FOUND DAMAGE TO ONE OF THE FAN BLADES ON NR 2 ENGINE. DETERMINE DIMENSIONS AND REPORT TO SAMC. BLADE NR 18. DAMAGE DETERMINED TO BE IN…
- 26 Mar 2011
Duct, dirty
CREW REPORT: RIGHT RECIRC FAN VERY LOUD, INTEFERES WITH COCKPIT COMMUNICATIONS, MUCH QUIETER WITH FAN OFF. COMPLIED WITH MEL TO DEACTIVATE THE RIGHT RECIRC…
- 8 Mar 2011
Check Valve, malfunctioned
FUEL TRANSFER PROBLEM. WITH RT TANK FULL AND RT PUMPS ON, MONITORED FUEL QUANTITIES FOR 2 HOURS. NO TRANSFER NOTED, ALL QTYS REMAINED CONSTANT. ACCOMPLISHED…
- 7 Feb 2011
Light, inoperative
EMERGENCY STRIP COMING UP NEAR 6B, SECURED POWER RIBBON AND EMERGENCY COVER AT SEAT 6B, BUT ALL EMERGENCY FLOOR LIGHTS IN 1ST CLASS ARE INOPERATIVE.
- 7 Feb 2011
Lamp, inoperative
EMERGENCY STRIP IN FRONT OF LAV FWD NR2 MED IS INOP. REPLACED ENCAPSULATED LAMP ASSY, CHECKED OK.
- 13 Jan 2011
Light, loose
EMERGENCY LIGHT STRIP 6B TORN. REATTACHED LIGHT STRIP. OPS CHECKED OK.
- 10 Nov 2010
Light, loose
EMERGENCY EXIT FLOOR STRIP LOOSE 34C. SECURED STRIP.
- 11 Aug 2010
Duct, obstructed
F/D TEMP CONTROL ISSUE, RTFL. FOUND A MIX MANIFOLD FLOW STRAIGHTENER FIN LODGED IN THE FLIGHT DECK SUPPLY DUCT APPROX 21 INCHES DOWNSTREAM OF THE DUCT SPLIT,…
- 13 May 2010
Skin, damaged
2EA LIGHTNING STRIKES DURING SCRIBE IQ. DAMAGE FOUND AT FUSELAGE SKIN AT STA 497, STR 14L DUE TO LIGHTNING STRIKE. BS 538, STRINGER 14L. DAMAGE IS .250" IN…
- 19 Feb 2010
Unknown, smoke
SMOKE FILLED COCKPIT DURING REVERSE. DISSIPATED QUICKLY. RAN BOTH ENGS IN REVERSE AND FWD THRUST WITH PACKS ON. NO SMOKE, MIST OR ODOR NOTED. SUSPECT SAND AND…
- 25 Jun 2009
Skin, damaged
PUNCTURE HOLE IN FUSELAGE AT STA 625 FWD OF DOOR 2L, 22 INCHES BELOW PASSENGER WINDOW NR 10. HOLE IS .75 INCH BY 1.75 INCH. FOUR (4) HORIZONTAL RIVETS BELOW…
- 24 May 2009
Battery Pack, inoperative
CABIN FLOOR EEL DOES NOT ILLUMINATE BETWEEN SEAT ROW 9-15. REPLACED POWER SUPPLY BATTERY PACK M10567.
- 22 Apr 2009
Antenna, damaged
LIGHTNING STRIKES TO RT FUSELAGE. FLIGHT DIVERTED. ACCOMPLISHED LIGHTNING STRIKE INSPECTION. VHF ANTENNA ABOVE MAIN ENTRY DOOR NR 2 HAS DAMAGE DUE TO STATIC…
- 18 Apr 2009
Unknown, odor
BURNING ODOR IN COCKPIT LINGERING AFTER PACKS TURNED ON. ODOR FROM LT PACK ONLY. ODOR DISSIPATED AFTER 20 MINUTES GROUND OPS. NO HISTORY. NO FURTHER INCIDENTS…
- 23 Dec 2008
Inverter, inoperative
AFT LOWER EXIT SIGNS AND 2 AISLE ILLUMINATION LIGHTS FAIL TO ILLUMINATE DURING TEST. NEEDS INVERTER, LOCATED ABOVE AFT GALLEY CEILING AFT OF MID FLORESCENT…
- 6 Sep 2008
Lamp, inoperative
NR 4 DOOR LT EMERGENCY EXTERIOR LIGHT INOP. RELAMPED, OPS CHECK GOOD.
- 17 Jul 2008
Frame, dented
DENT IN UPPER LEG (INBOARD FLANGE) OF FUSELAGE FRAME BS 520, LBL 36. *S/D* ACCOMPLISHED A MAJOR REPAIR AT GSO. TRIMMED OUT DAMAGE TO FRAME INNER FLANGE,…
- 17 Jul 2008
Frame, dented
DENT IN UPPER LEG (INBOARD FLANGE) OF FUSELAGE FRAME BS 540, LBL 36. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. TRIMMED OUT DAMAGE TO FRAME INNER FLANGE AND…
- 12 Jul 2008
Frame, dented
AFT PIT FRAME DENTED AT INBOARD FLANGE, BS 1400 BETWEEN STR 15L-26L. ACCOMPLISHED MAJOR REPAIR. CUT OUT FRAME DAMAGE AND INSTALLED DOUBLER REPAIR PER SRM…
- 10 Jul 2008
Frame, dented
AFT PIT FRAME DENTED AT INBOARD FLANGE, BS 1420 BETWEEN STR 25L - 26L, 2 PLACES. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR…
- 10 Jul 2008
Frame, dented
AFT PIT LT SIDE SLANT AREA HAS DENTED FRAME STA 1580 BETWEEN STR 26L AND 27L. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR PER…
- 10 Jul 2008
Frame, dented
AFT PIT FRAME IS DENTED AT INBOARD FLANGE AT BS 1380, STR 26L. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR PER SRM 53-00-07,…
- 10 Jul 2008
Frame, dented
AFT PIT AT STA 1480 BETWEEN, STR 25L AND STR 26L, FRAME DENTED AT INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGED FROM FRAME AND INSTALLED…
- 10 Jul 2008
Oxygen Mask, faulty
CAPTAIN'S O2 MASK DOES NOT TRANSMIT THROUGH PA. WIRING SHORT INTERNAL TO MASK. REPLACED CAPT O2 MASK ASSY, OPS CHECKED NORMALLY.
- 10 Jul 2008
Gate, corroded
R2 DOOR LOWER GATE CORRODED AND CRACKED. REPLACED LWR GATE PER MM 52-11-38.
- 9 Jul 2008
Gate, corroded
L-1 DOOR, LOWER GATE CORRODED. *S/D* REPLACED LWR GATE REF SM-5 0-52-11-02-JD.
- 9 Jul 2008
Structure, corroded
CORROSION UNDER R-4 DOOR CAM PLATE INSERTS. REPLACED HANDLE BOX REF CM M-52-11-25.
- 9 Jul 2008
Doubler, out of tolerance
R-2 DOOR REQUIRES DOUBLER AT UPPER HINGE ARM CUTOUT. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. INSTALLED DOUBLER PER MM 52-11-87.
- 9 Jul 2008
Structure, out of tolerance
L-2 DOOR REQUIRES DOUBLER AT UPPER HINGE ARM CUTOUT. ACCOMPLISHED MAJOR REPAIR AT GSO. INSTALLED DOUBLER RPR PER MM 52-11-87.
- 9 Jul 2008
Frame, dented
AFT PIT LT SIDE SLANT AREA HAS DENTED FRAME STA 1500 AT STR 26L. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. CUT OUT DAMAGE AND INSTALLED NEW STR SECTION PER SRM…
- 8 Jul 2008
Frame, dented
AFT PIT LT SIDE SLANT AREA HAS DENTED FRAME STA 1540 AT STR 26L. *S/D* ACCOMPLISHED A MAJOR REPAIR AT GSO. RPR FRAME IAW SRM 53-00-07 RPR 5 DETAIL I. THIS IS…
- 8 Jul 2008
Frame, dented
AFT PIT LT SIDE SLANT AREA HAS DENTED FRAME AT STA 1480 AT STR 26L. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. REPAIRED ON NR 31083.
- 8 Jul 2008
Frame, dented
AFT PIT FRAME DENTED AT INBOARD FLANGE BS 1440, STR 26L. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. RPR FRAME IAW SRM 53-00-07 RPR 5 DETAIL I. THIS IS A CAT B…
- 8 Jul 2008
Frame, dented
AFT PIT AT STA 1560, APPROX STR 26L, FRAME DENTED AT INBOARD FLANGE. *S/D* ACCOMPLISHED MAJOR REPAIR AT GSO. AFT PIT AT STA 1560, APPROX STR 26L, FRAME DENTED…
- 8 Jul 2008
Frame, dented
AFT PIT AT STA 1520, STR 25L FRAME DENTED AT INBOARD FLANGE. SUPPLEMENTAL DATA UPDATE ACCOMPLISHED MAJOR REPAIR AT GSO. RPR FRAME IAW SRM 53-00-07 RPR 5…
- 6 Jul 2008
Structure, corroded
BACKSHOP - 2R DOOR, CORROSION AT BASKET CAM ATTACHMENT INSERT LOCATION 1 PLACE. *S/D* AFTER FURTHER ANALYSIS, IT HAS BEEN DETERMINED THIS IS NOT AN SDR…
- 2 Jul 2008
Skin, damaged
LIGHTNING STRIKE AT EXT FUSELAGE SKIN AT STA 1380, 1 INCH BELOW STR 4L. DAMAGE FROM LIGHTNING STRIKE. REMOVED DAMAGED PER MM 53- 30-95, P603, ITEM B. ACP HFEC…
- 2 Jul 2008
Skin, damaged
LIGHTNING STRIKE ON RIVET EDGE AT STA 1415, STR 1. DAMAGE FROM LIGHTNING STRIKE. REMOVED AND REPLACED DAMAGED FASTENER WITH BLIND FASTENER PER MM 53-30-95,…
- 2 Jul 2008
Skin, damaged
LIGHTNING STRIKE ON FUSELAGE SKIN AT STA 1445, 1 INCH LEFT OF STR 1. *S/D* DAMAGE FROM LIGHTNING STRIKE. REMOVE DAMAGE PER MM 53-30 -95 PG 603, ITEM B BY…
- 2 Jul 2008
Skin, damaged
LIGHTNING STRIKE ON RIVET EDGE AT STR1, STA 1345. *S/D* DAMAGE FROM LIGHTNING STRIKE. REMOVED DAMAGED FASTENER, A CP HEFC INSP PER NDT MM 51-00-16. NO CRACK…
- 2 Jul 2008
Skin, damaged
LIGHTNING STRIKE ON RIVET EDGE AT STA 1379, STR 1. *S/D* DAMAGE FROM LIGHTNING STRIKE. REMOVED DAMAGED FASTENER, A CP HEFC INSP PER NDT MM 51-00-16. NO CRACK…
- 15 Jun 2008
Light, inoperative
DOOR 4R EMERGENCY LIGHT INOP, EXTERIOR. LAMP INOP. RELAMPED EMERGENCY LIGHT, OPS CHECKED GOOD.
- 25 Apr 2008
Contact, dirty
WHEEL WELL FIRE LIGHT TESTS OK DURING LIGHT TEST DOESN'T ILLUM DURING FIRE TEST. FOUND SWITCH CONTACTS DIRTY. CLEANED SWITCH CONTACTS, REINSTALLED, WORKS…
- 6 Apr 2008
Oxygen Bottle, unknown
O2 BOTTLE OVERHEAD 15ABC NEEDS WORK. REPLACED O2 BOTTLE.
- 3 Sep 2007
Unknown, smoke
ACRID SMELL WITH LITE SMOKE IN MID GALLEY. RAN GALLEY FIRE SMOKE QRC SMOKE DISSIPATED.
- 26 Jun 2007
Light, inoperative
DOOR 4 RIGHT EXTERIOR EMERGENCY SLIDE LIGHT INOPERATIVE. RELAMPED EMERGENCY LIGHT, OP CHECK GOOD.
- 26 May 2007
Slide, unsecure
DOOR SLIDE 1L FELL OUT ON TO AIR STAIR DUE TO NOT BEING DISARMED. [06-20-07] REMOVED AND REPLACED DOOR 1 LT SLIDE AND EMERGENCY POWER RESERVOIR.
- 13 Apr 2007
Sign, loose
EXIT SIGN OVER RIGHT SIDE EMERGENCY EXIT WINDOW IS COMING LOOSE. [SUP 05-16-07] SECURED LENSE.
- 22 Mar 2007
Bottle, underserviced
LOW PRESSURE ON CYLINDER. [SUP 05-16-07] BOTTLE WAS UNDERFILLED. FILLED BOTTLE TO SPECIFICATIONS.
- 21 Jan 2007
Skin, dented
SKIN DENTED AT STA 756 STR 16L MEASURING 1.5 INCHES WIDE AND A DEPTH OF 0.124 INCH. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR. PERMANENT REPAIR TO…
- 15 Sep 2006
Unknown, odor
SLIGHT BURNING ODOR IN AREA AROUND ROWS 15&16. VISUALLY INSPECTED AREA, UNABLE TO LOCATE SOURCE OF ODOR IN CABIN. MIGHT INVOLVE OVERHEAD TV MONITOR. NO…
- 2 Dec 2005
Wedge, delaminated
T/E WEDGE DELAMINATED NR 5 SLAT. REPAIRED WEDGE IN SHOP 273 AUTOCLAVE PER SRM 50-57-56-01 ON R66 864.
- 2 Aug 2005
Slide, leaking
TUBE ASSY FAILED AIR RETENTION TEST DUE TO EXCESSIVE POROSITY LEAKING THROUGH TUBE FABRIC NOTED ON VARIOUS LOCATIONS. DURING COMPONENT SHOP MAINTENANCE SLIDE…
- 20 Jul 2005
Keelbeam, corroded
KEEL BEAM CORROSION. EXT CHORD BS 1180 TO 1176, APPROXIMATELY 6 LBL TO 6 RBL. REMOVE CORROSION AND CK LIMIT PER SRM 53-30-12. ORIGINAL THICKNESS=.130", AFTER…
- 13 Jul 2005
Power Supply, discharged
EMERGENCY LIGHTS INOP AT FOLLOWING LOCATIONS: AISLE LIGHT IN BULLNOSE AT ROW 25, CEILING EXIT SIGN AT ROW 16 AND EXTERIOR SLIDE LIGHT ON AFT CARGO DOOR. POWER…
- 2 May 2003
Windshield, cracked
1R COCKPIT WINDSHIELD CRACKED. FIRST OFFICERS WINDSHIELD STARTED ARCING IN LOWER CORNER AND PROGRESSED INTO THE WINDOW UNTIL THE WINDOW SHATTERED. FOD DAMAGED…
- 2 Aug 2002
Skin, dented
FUSELAGE SKIN DENTED 6.75 IN IN FORWARD OF BODY STATION 1720 AND .5 IN BELOW STRINGER 20L. MAJOR REPAIR ACCOMPLISHED. EXTERNAL FUSELAGE SKIN REPAIRED. DOUBLER…
- 1 Aug 2002
Shear Tie, fractured
RIGHT HAND WING LOWER CHORD SHEAR TIE AT WS313.5 BETWEEN STRINGER 10 AND STRINGER 11 WAS FRACTURED DURING FASTENER INSTALLATION. MAJOR REPAIR ACCOMPLISHED.…
- 31 Jul 2002
Intercostal, cracked
FORWARD CABIN #2 LH SERVICE DOOR CUTOUT INTERCOSTAL CRACKED, BODY STATION 680 JUST BELOW STRINGER 11L CRACKED TWO PLACES. SUPPLEMENTAL DATA UPDATE MAJOR…
- 31 Jul 2002
Intercostal, cracked
FORWARD CABIN #2 RIGHT HAND SERVICE DOOR CUTOUT INTERCOSTAL CRACKED, BODY STATION 680 FORWARD OF #4 DOOR STOP PIN FITTING. SUPPLEMENTAL DATA UPDATE MAJOR…
- 31 Jul 2002
Intercostal, cracked
CAB INTERCOSTAL #12 LEFT HAND SIDE HAS CRACK AT O-B RADIUS BODY STATION 680. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPLACED INTERCOSTAL.
- 31 Jul 2002
Skin, dented
EXTERIOR FUSELAGE BODY STATION 600-620 HAS SEVERAL DENTS ON SKIN FORWARD OF DOOR 2L. MAJOR REPAIR ACCOMPLISHED. DOUBLER AND TRIPLER INSTALLED.
- 31 Jul 2002
Intercostal, cracked
FORWARD CABIN #2 SERVICE DOOR CUTOUT, INTERCOSTAL CRACKED AT BODY STATION 680 JUST BELOW STRINGER 11R. MAJOR REPAIR ACCOMPLISHED. REPLACED INTERCOSTAL.
- 30 Jul 2002
Floorbeam, corroded
FORWARD CABIN FLOORBEAM UPPER T-CAP AT BODY STATION 365.25 RBL 09 TO RBL 60 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED T-CAP.
- 30 Jul 2002
Stringer, dented
FUSELAGE STRINGER 16L DENTED STATION 610-615. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED STRINGER SPLICE REPAIR.
- 30 Jul 2002
Crease Beam, corroded
CABIN FLOOR CREASE BEAM I/B CHORD EXCESSIVE MATERIAL REMOVED FROM CORROSION, STATION 755 STRINGER 17L. MAJOR REPAIR ACCOMPLISHED. INSTALLED CREASE BEAM SPLICE…
- 30 Jul 2002
Intercostal, corroded
FORWARD CABIN FLOOR INTERCOSTAL STATION 369 RBL 58 STRINGER 17R, HAS CORROSION AROUND FASTENER HOLE. MAJOR REPAIR ACCOMPLISHED. REPLACED WITH NEW INTERCOSTAL.
- 30 Jul 2002
Intercostal, corroded
FORWARD CABIN FLOOR INTERCOSTAL STATION 368, RBL 10.5 UPPER SURFACE CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW INTERCOSTAL.
- 30 Jul 2002
Floorbeam, corroded
FORWARD CABIN FLOORBEAM UPPER CAP CORRODED, STATION 324 RBL 42. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR STRAP.
- 29 Jul 2002
Floorbeam, damaged
CABIN FLOORBEAM CAP UPPER SURFACE, STA 660 LBL 24, HAS EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. STRAP AND ANGLE INSTALLED.
- 29 Jul 2002
Crease Beam, corroded
FORWARD CABIN FLOOR CREASE BEAM I/B CHORD HAS SURFACE CORROSION STATION 310 TO STATION 365 RBL 63. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM I/B CHORD.
- 28 Jul 2002
Seat Track, damaged
CABIN SEAT TRACK MOUNT FLANGE UPPER SURFACE HAS EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. REPLACED SEAT TRACK BEAM.
- 25 Jul 2002
Skin, dented
EXTERNAL FUSELAGE DENT AFT OF DOOR 2L BODY STATION 740 STRINGER 16L. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER INSTALLED.
- 17 Jul 2002
Floorbeam, corroded
CABIN FLOORBEAM STATION 1660 BL 0 UPPER FLANGE HAS 18.6 PERCENT MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. REPAIRED FLOORBEAM UPPER CAP. BLEND OUT ANGLE AND…
- 11 Mar 2001
Skin, cracked
NR 2 ENGINE PYLON IB SKIN CRACKED AT FWD LIGHTING HOLE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.REPAIRED SKIN PER MAINTENANCE MANUAL.
- 28 Nov 1997
Mechanism, out of adjust
RETURNED TO FIELD DUE TO DOOR 4L HANDLE POPPING UP. *S/D* DOOR OUT OF ADJUSTMENT. WHILE PRESSURIZED, THE DOOR HANDLE WAS ABLE TO MOVE, WHEN A SMALL AMOUNT OF…
- 6 Sep 1997
Diffuser, bad repair
APU DROPS OFF LINE AT ENGINE START. ALSO, APU WILL NOT HOLD ELECTRICAL POWER. *S/D* AFTER REMOVING CHRONIC APU, FOUND DRIVEN COMPRESSOR DIFFUSER WITH VERY…
- 3 Sep 1997
Diffuser, misrepaired
APU PRESSURE GOES TO ZERO ON ENGINE START AND GENERATOR GOES OFF-LINE. APU PNUEMATIC AND ELECTRICAL INOP. APU INOP. *S/D* AFTER REMOVING CHRONIC APU, FOUND…
- 24 Jan 1996
Pca Transformer, malfunctioned
SPOILER HANDLE GOES TO FULL EXTEND AS SOON AS HANDLE IS ARMED. SUPPLEMENTAL DATA UPDATE: NR 3 FAULT ON THE SPOILER CONTROL MODULE. REPLACED NR 4 SPOILER PCA…
- 16 Aug 1995
Eel Connector, loose
EEL LIGHT INOP AT MID LAV. FOUND EEL CONNECTOR LOOSE RESECURED.