- 7 Jan 2025
Autopilot Sys, faulted
AT TAKEOFF ALL AUTOMATION BECAME INOPERATIVE, FD, AUTOTHRUST, NO FMA READ OUT. -PERFORMED LC3CT + AFS TEST PER AMM 22-96-00 + 22-97-00. OPS CHECK NORMAL .
- 19 Aug 2024
Unknown, odor
AIR QUALITY/FUME EVENT DIRTY SOCK SMELL REPORTED BY FAS AT 3000' AFE DURING APPROACH ALSO IN FLIGHT DECK. SHUT OFF PACK 2 CONTINUED APPROACH FAS SAID SMELL…
- 2 Jun 2024
Unknown, odor
STRONG SMOKE BURNING ODOR LIKE SHORTHING BURNING REPORT BY LEAD FLIGHT ATTENDANT ALSO FELT ON THE COCKPIT BUT NOT AS STRONG DURING DESCENT.-REF TSM…
- 29 May 2024
Stud, loose
ENG 1 HIGH ECT LIMIT DURNING CLIMBOUT-PERFORMED GVI FOUND STUD LOOSE ON BOTTOM R/H SIDE OF ENG # 1 THERMOCOUPLE R&RD IAW AMM 77-21-15, PERFORMED TSM…
- 4 May 2024
Unknown, odor
DURING DESCENT FROM 1600 TO 10000 STRONG OILY/ ACRID SMEEL IN COCKPIT AND AFT GALLEY-PERFORMED AIR QUALITY EVENT AND SOURCE IDENTIFICATION IAW TASK CARD TI…
- 26 Apr 2024
Seal, leaking
DIRTY SOCK SMELL ON DESENT FL180. SWITCHING PACK 1 OFF ELIMINATES THE ISSUE-T/S IAW TSM 05-50-00 . FOUND ENG. NR 1 LEAKING ON THE DEOILER.R&R DEOILER SEAL…
- 24 Apr 2024
A/C Pack, odor
DIRTY SOCK SMELL DURING APPROACH TO LAND FROM PACK 1. AFTER PACK 1 WAS TURNED OFF, SMELL DISSAPEAR. ( PACKS A319 WITH MOD. 30626/MP K6443 (ENHANCED ECS)…
- 15 Oct 2023
Unknown, unknown
FUME EVENT IN FLIGHT. PERFORMED ELIMINATION OF ODOR / FUMEA IN COCKPIT / CABIN TURNED OFF PACK 2 - SEEMED TO HELP-REF TSM 05-50-00-810-831-0-A FOUND APU OVER…
- 23 Mar 2023
Battery, no test
DURING SVC CHECK, EPSU TEST GOT FAULT BAT/EPSU (11WL) EMER L-R&R EPSU BATTERY (11WL) IAW AMM 33-51-38 OPS TEST OK
- 20 Feb 2023
Lever, stuck
CREW REPORTS GEAR HANDLE IS STUCK AND UNABLE TO RETRACT GEAR. A/C TURNED BACK TO MCO AND LANDED WITH OUT INCIDENT. A/C WILL NEED TO BE PUT ON JACKS FOR…
- 21 Oct 2022
A/C Pack, odor
F/A A REPORT DIRTY SOX SMELL AT THE FORWARD GALLEY. SMELL WHEN AWAY AFTER PACK #2 OFF-PERFORMED ECS DE-CONTAMINATION OF PACKS SYSTEM REF AMM 21-00-00.…
- 3 Aug 2022
None, damaged
THRESHOLD PANEL 261LG FOUND DAMAGE RAF 2935795-02 OPENED.-VERIFIED NR # 5001171840-0030 AND TC # 1003784506-0010. REPAIR WAS PERFORMED AS PER SPIRIT EO…
- 3 Aug 2022
Frame, damaged
"DURING HEAVY CHECK FOUND GAUGE AT FRAME 4 RAF 2935789-02 OPENED SDR ITEM -VERIFIED NR #5001172370-0010 AND TC #1003780993-0010, REPAIR WAS PERFORMED AS PER…
- 3 Aug 2022
Stringer, corroded
"DURING HEAVY CHECK FOUND CORROSION ON STRINGER 43LH RAF 2935792-02 OPENED SDR ITEM -VERIFIED NR # 5001171997-0010 AND TC # 1003783534-0010. REWORK WAS…
- 3 Aug 2022
None, corroded
DURING CHECK FOUND CORROSION AT STRAP BUTT CROSS AT FRAME 47-51 STR 41-42 LH RAF 2935796-01 OPEN SDR ITEM -VERIFIED NR # 5001171997-0050 AND TC #…
- 3 Aug 2022
None, corroded
"DURING HEAVY CHECK FOUND CORROSION ON FRAME 64 BUTT STRAP RAF 2935790-02 OPENED SDR ITEM -VERIFIED NR # 5001171997-0020 AND TC # 1003779157-0010. CORROSION…
- 3 Aug 2022
None, damaged
"DURING HEAVY CHECK FOUND GOUGE ON #1 PYLON RAF # 2935790-01 OPENED SDR ITEM -VERIFIED NR # 5001171797-0030 AND TC # 1003778439-0010. GOUGE WAS REPAIRED AS…
- 4 Jan 2022
Unknown, odor
FUME EVENT ON DECENT-PERFORMED GVI OF APU COMP AND BOTH ENGS FOR EVIDANCE OF OIL NO DEFECTS NOTED. PERFORMED PACK BURN OUT WITH BOTH ENGINES AND APU IAW AMM…
- 2 Aug 2021
Battery Pack, no test
"11WL & 13WL EPSU BATTERIES FAILED TEST-R&R 11WL & 13WL EPSU BATTERIES IAW A319 AMM 33-51-38 OPS CHECK GOOD REF HEACO NR 28069"
- 11 May 2021
Bottle, low pressure
PASSENGER L1 AND R2 DOOR ASSIST BOTTLES REQUIRE SERVICE.-SERVICED PASSENGER L1 AND R2 DOOR ASSIST BOTTLES IAW AMM 52-10-00.
- 4 Jan 2020
Unknown, odor
DURING DESCENT THRU 10,000, FA IN AFT CABIN REPORTED FUME EVENT. ODOR SMELLED LIKE BLEACH OR NAIL POLISH REMOVER. PACK #2 WAS TURNED OFF, FA'S SAID SMELL WENT…
- 22 Apr 2019
Unknown, odor
SUSPECTED FUME VENT ON SHORT FINAL IN COCKPIT AND FWD GALLEY. PERFORMED INSPECTION OF AIRFRAME AND ENGINES NO LEAKAGE NOTED IAW AMM 05-51-00 PERFORMED PACK…
- 20 Apr 2019
A/C Pack, odor
SMELLING RESIDUAL ODOR FROM FUME EVENT-PERFORMED CABIN ODOR ISOLATION AND FOUND PACK 2 TO BE THE SOURCE OF THE ODOR. INSPECTED BOTH ENGINES AND APU NO…
- 19 Apr 2019
Unknown, fumes
FUME EVENT-FOLLOWING TSM 05-50-00, PERFORM EXTERNAL INSP. NO EVIDENCE OF FLUIDS ON ENG, APU INLET, OR PACK INLET NOTED. RAN PACK 1 & 2 USING ALL SOURCES OF…
- 1 Jan 2019
Unknown, odor
HEAVY RAIN AT DEPARTURE AIRPORT. WHEN DESCENDING TO DESTINATION MCO AT APPROX 4,500 WHEN AVEC DOORS OPENED THERE WAS A HEAVY DIRTY SOCKS SMELL IN THE COCKPIT…
- 26 Oct 2018
A/C Pack, odor
A STRONG CHEMICAL SMELL WAS REPORTED BY FA DURING DESCENT. THE SMELL WAS THROUGHTOUT THE CABIN, BUT STRONGER IN THE FORWARD CABIN . THE SMELL STOPPED WHEN…
- 20 Oct 2018
A/C Pack, odor
FUME EVENT ON APPROACH OUT OF 60 FT. MUSTY DRY SMELL SECURED PACK NR 1 SHUT XFEED VALVE-PERFORMED TSM 05-50-00-810-831-A ODER TO BE COMING FROM PACK 1 REF LOG…
- 18 Oct 2018
Unknown, odor
FLIGHT CREW AND FA SMELLED CHEMICAL ODOR IN DESCENT AND AGAIN AFTER LANDING. -FOLLOWED TSM FOR IDENTIFICATION OF CABIN ODOR IAW TSM 05-50-00. TROUBLESHOOTING…
- 16 Oct 2018
Unknown, odor
FA A REPORTS THAT AFT CABIN FLT ATTENDANT SMELLED DIRTY SOCKS SMELL BELOW 10,000 AND BEFORE LANDING FAK OPENED BY FA FOR FORMS TO REPORT-PERFORM CABIN ODOR…
- 15 Oct 2018
A/C Pack, odor
FLIGHT ATTENDANTS COMPLAINING OF SOCK SMELL THROUGHOUT THE CABIN. R&R RECIRCULACION FILTER IAW CMM 21-21-51. CABIN ODOR STILL PRESENT. DUE TO PACK 1.
- 11 Oct 2018
A/C Pack, odor
DIRTY SOCK SMELL THROUGHT AIRCRAFT. PERFORMED INSPECTION IAW TSM 05-50-00-810-831-A. FOUND PACK 1 TO BE SOURCE OF SMELL.
- 26 Sep 2018
A/C Pack, odor
"FUMES SUSPECTED ON PACK 1 DID SEVERAL ISOLATIONS AND CONFIRMED PACK ONE SMELL-PERFORMED IDENTIFICATION OF THE CAUSE OF CABIN ODORS OR SMOKE. FOUND PACK#1 TO…
- 23 Sep 2018
Unknown, odor
APU BLEED ON DIRTY SOCK SMELL (APU SYSTEM). INSPECTED APU AREA PER AMM 49-00-00, NO LEAKS NOTED AT THIS TIME.
- 14 Sep 2018
Door, unsecure
FRONT LAV BIN DOOR FOUND ON FLOOR NOT CONNECTED TO HINGES. REATTACHED DOOR AS NEEDED REF MM 25-41-00.
- 29 Aug 2018
Unknown, odor
DIRTY SOCKS ODOR IN THE COCKPIT. PERFORMED A NR 1 &2 ENGINE RUN-UP IAW AMM 71-00-00-710-047-A, WITH APU & APU BLEED OFF FOR 10 MINUTES, NO ODOR DETECTED.
- 24 Jul 2018
Unknown, odor
STRONG DIRTY SOCK ODOR IN COCKPIT. PERFORMED CAUSE OF ODOR TROUBLESHOOTING IAW TSM 05-50-00 AND DECONTAMINATION OF ECS 1 IAW AMM 21-00-00-615-001 NO…
- 22 Jul 2018
Unknown, odor
PILOTS REPORTED DIRTY SOCK SMELL IN CABIN. (PACKS WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 370)
- 16 Apr 2018
A/C Pack, odor
FUME EVENT DURING APPROCH, ODOR FROM THE NR 1 PACK. NO ODOR IN CABIN. ON ARRIVAL, NARROWED THE FUME EVEN TO CONTAMINATION, SOURCE THE NR 1 PACK. ACCOMPLISHED…
- 16 Nov 2017
Skin, dented
DENTS FOUND DURING A WALK AROUND. PERFORMED A REPAIR IAW EO 5311-1784, REV 00, AND RDAS 80383039/003/2017.
- 11 Nov 2017
Unknown, odor
AFT F/A REPORTS STRANGE DIRTY SOCK ODOR UPON LANDING FULL REVERSE WAS USED. INSPECTED THE APU BAY, NO EVIDENCE OF OIL LEAKS. RAN APU, ENG AND OPERATED AIR…
- 12 Jul 2017
Seal, torn
ACFT VIBRATION & LOUD CLICKING FOUND BETWEEN ROW 12 & 13. HEARD & FELT DURING CLIMB & ENROUTE PORTIONS OF FLIGHT. AN ODOR OF BURNING HAIR WAS ASSOCIATED WITH…
- 2 Jul 2017
Battery, inoperative
R2 DOOR FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED THE BATTERY IAW CMM 25-60-02. OPS TESTED GOOD.
- 29 Jun 2017
Door, leaking
VERY LOUD BUZZING NOISE COMING FROM RIGHT OVERWING EXIT DOOR. WORSE DURING CLIMB. NO PRESSURIZATION ISSUES NOTED.
- 20 Jun 2017
Unknown, leaking
DURING CRUISE FLIGHT, A LOUD BUZZING NOISE FROM THE EMERGENCY EXIT DOOR RIGHT SIDE. PERFORMED PRESSURIZATION TEST IAW AMM 05-53-00 PB501, CONF 00. OPS CHECKED…
- 14 Jun 2017
Unknown, odor
IN FLIGHT FA'S REPORT ODOR AT ROWS 7-13, ODOR OF NAIL POLISH OR RADIATOR. PERFORMED TSM 05-50-00-810-831-A. PERFORMED COMPARTMENT CHECK OF APU BLEED WITH PACK…
- 3 Jun 2017
Handle, leaking
F/A REPORTS LOUD SQUEAL FROM RIGHT OVERWING EMERGENCY EXIT. PRESSURIZED AIRCRAFT IAW AMM 21-31-00 CONFIRMED FAULT. FOUND LEAK AT EXTERIOR DOOR HANDLE. REMOVED…
- 3 Jun 2017
Light, miswired
L2 EMERGENCY EXIT LIGHT NOT ON IN ARMED MODE. INSPECTED AND FOUND WIRES CROSSED BETWEEN EMRGENCY LIGHT UNDERNEATH. INSTALLED WIRES CORECTLY IAW AMM 33-51-11.
- 3 Jun 2017
Seal, dirty
HISSING SOUND FROM OVERWING EXIT DURING FLIGHT REPORTED BY FLIGHT ATTENDANT. REMOVED THE RT WING EMERGENCY EXIT, CLEANED THE SEAL AND REINSTALLED RT EMERGENCY…
- 31 May 2017
Seal, dirty
F/A REPORTS LOUD SQUEAL FROM RIGHT OVERWING EMERGENCY EXIT..PRESSURIZED AIRCRAFT IAW AMM 21-31-00 CONFIRMED FAULT. FOUND LEAK AT EXTERIOR DOOR HANDLE. REMOVED…