N528CA
2026 Cirrus Design Corp SR22 standard FAA →
registration
- 2026
earlier registrations
2 past records
- 2003
NTSB
- 26 Jun 1990
accident, Fillmore CA
service difficulty reports
46 reports
- 6 Dec 2016
Battery Pack, corroded
EMERGENCY LIGHTS OUT IN GALLEY AND MID CABIN. REMOVED AND REPLACED BATTERY PACK ASSY PER AMM 33-51-04. OPS CHECKED GOOD, NO FURTHER DEFECTS NOTED.
- 17 Apr 2014
Lamp, burned out
FWD ORANGE SEGMENT OF EMERGENCY FLOOR PATH LIGHTS INOPERATIVE. R & R EMERGENCY FLOOR PATH LIGHT FLEXIBLE LAMP NR 1 IAW AMM 33-51-01. OPS CHECK GOOD. SDR CLOSED.
- 6 Mar 2014
Light, inoperative
CABIN FLOOR FORWARD MOST EMERGENCY LIGHT STRIP, ORANGE, INOPERATIVE. PERFORMED THE OPS TEST OF THE EMERGENCY FLOOD LIGHTS IAW AMM 33-51-00. OPS CHK GOOD.
- 3 Sep 2013
Connector, disconnected
EMERGENCY LIGHT STRIP ABOVE PAX DOOR DOES NOT ILLUMINATE. REINSTALLED CONNECTOR FOR EMERGENCY EXIT SIGN IAW AMM 33-51-01.
- 30 Apr 2013
Battery Pack, discharged
EMERGENCY LIGHT AT ROW 5 INOPERATIVE. FOUND BATTERY PACK TO BE DISCHARGED. CHARGED BATTERY PACK. OPS CHECKED GOOD IAW AMM 33-51-00.
- 22 Apr 2013
Skin, damaged
RT OTBD FLAP DAMAGED ON T/E. 41" FROM INBD END, DAMAGE IS APPROX 10" L. COMPLIED WITH MAJOR REPAIR IAW REO 601R-57-53-041, REV A, DATED 2004/05/07. COMPLIED…
- 8 Apr 2013
Bulkhead, damaged
AT FS 621.00 BULKHEAD LBL 30 WL 135 THERE IS A DRILL START .150" WIDE .031" DEEP AND .150" FROM CENTER OF FIRE BLOCK HOLE/NUTPLATE AT .1562" TO CENTER OF…
- 8 Apr 2013
Floor Panel, dented
PRESSURE FLOOR SKIN HAS 1 EA DENT MEASURING 4.256" LONG X 1.980" WIDE X .015" DEEP AND HAS 5 EA GOUGES WITH MAX DAMAGE BEING .730" LONG X .062" WIDE X .008"…
- 6 Apr 2013
Bushing, damaged
LT BUSHINGS AT HORIZONTAL STAB HINGE ARE DAMAGED. REPAIRED IAW REO 601R-55-00-045 REV B, 2013/04/27. MAJOR REPAIR
- 5 Apr 2013
Intercostal, cracked
FS 621.00 CRACKED INTERCOSTAL STRINGER 13L,. REMOVED CRACKED INTERCOSTAL IAW SRM 51-42-21. LOCATED & DRILLED NEW INTERCOSTAL IAW SRM 51-40-11. INSTALLED…
- 4 Apr 2013
Bulkhead, cracked
FOUND REAR PRESSURE BULKHEAD WEB HAS INDICATION NOTED AT LBL 27.50 WL 130 APPROX .2" IN LENGTH 60 PERCENT FSH FAILED NDT INSPECTION. REPAIRED IAW REO…
- 3 Apr 2013
Post, cracked
FOUND FS 409.00+128 VERTICAL POST BL 0.00 RT SIDE HAS INDICATION NOTED AT AFT FLANGE RADIUS WL 69.0 APPROX .2" IN LENGTH 50 PERCENT FSH. FAILED NDT…
- 3 Apr 2013
Bulkhead, cracked
FOUND FS 559 BULKHEAD WEB RT SIDE HAS INDICATION NOTED APPROX .3" IN LENGTH 50 PERCENT FSH AT WL 59.10 INBD OF RBL 18.0. FAILED NDT INSPECTION. REPAIRED IAW…
- 3 Feb 2013
Circuit Card, unserviceable
UNCOMMANDED FULL RT RUDDER DEFECTION IN FLT ON A/P, NO EICAS MSG OVER POWERED, DISCONNECTED A/P AND YD, WERE ABLE TO RETRIM (ENROUTE, ACFT DIVERTED TO GSO DUE…
- 13 Aug 2012
Switch, illuminated
LEFT THRUST REVERSER UNLOCK MESSAGE. EMERGENCY DECLARED. R & R STOW SWITCH IAW AMM 78-37-01. OPS CHECKED GOOD.
- 22 May 2012
Sensing Element, broken
LT 10TH DUCT IN FLIGHT FOLLOWED CHECK LIST IT DID NOT GO OUT. DELCARED EMERGENCY AND RETURNED TO ATC (AFTER T/O ACFT RETURNED TO DEPARTURE AFTER T/O --…
- 9 Apr 2012
Pressure Blkhd, cracked
REAR PRESSURE BULKHEAD CRACKED AT RBL 36.20. REPAIRED IAW REO 601R-53-61-1285, REV D AND REO 601R-53-61-1285 REV D.
- 9 Apr 2012
Fitting, cracked
REAR PRESSURE BULKHEAD CRACKED AT MACHINE FITTING (LINTEL FITTING) AT CARGO DOOR CUTOUT. REPAIRED IAW REO 601R-53-61-1230, REV C.
- 6 Apr 2012
Wire, broken
WIRE BROKEN ON EMERGENCY FLOOR TRACK LIGHTING AT FWD END. REPLACED CRIMP CONNECTOR ON RT FWD EMERGENCY LIGHT FLOOR STRIP LIGHTING WIRE IAW ESPM 20-17-00. OPS…
- 9 Sep 2011
Connector, damaged
EMERGENCY LIGHTS INOPERATIVE, CENTER TWO SECTIONS AND FWD WHITE SECTION AT FLOOR POSITIONS. R & R FWD WHITE EMERG LIGHT SECTION IAW AMM 33-51-01-000-801 AND…
- 22 Aug 2011
Web, cracked
PASSENGER DOOR FWD WEB CRACKED AT 4TH RISER. REPAIRED IAW REO 601R-52-11-702.
- 22 Aug 2011
Drag Angle, cracked
PASSENGER DOOR AFT DRAG ANGLE CRACKED. REPAIRE IAW REO 601R-52-11-513 AND REO NR 610R-52-11-513, REV A.
- 22 Aug 2011
Angle, cracked
CARGO DOOR FWD TRACK LOWER C-CHANNEL ANGLE CRACKED. R & R DAMAGED C-CHANNEL IAW SRM 51-41-06 & 51-41-04. REPAIR IS CLASSIFIED AS A MINOR REPAIR.
- 22 Aug 2011
Angle, corroded
PASSENGER DOOR CUTOUT LOWER ANGLE HAS CORROSION AROUND HOLE FOR PROXIMITY SENSOR. REMOVED CORROSION IAW SRM 51-21-06 AND FOUND THE REMOVED MATERIAL (0.003)…
- 22 Aug 2011
Floorbeam, cracked
FS 280 TRANVERSE BEAM UPPER AFT J-ANGLE CRACKED OTBD OF LBL 9 AND RBL 9. REPAIRED IAW REO 601R-53-11-926 REV B.
- 22 Aug 2011
Beam, cracked
FS 280 TRANSVERSE BEAM CRACKED IN WEB OTBD OF RBL 9. THIS DISCREPANCY AND THE AFT J-ANGLES ON JOB 8784121, OP 159 IS BEING REPAIRED AS ONE IAW REO…
- 22 Aug 2011
Attach Fitting, cracked
CLIP AT FS 484.00, RBL 27 CRACKED. R & R A NEW CLIP AT FS 484.00, RBL 27 IAW SRM 51-42-21. THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR.
- 17 Aug 2011
Door, none
LEFT EMERGENCY OVERWING EXIT FAILS FUNCTION TEST, FORCE TO OPERATE HANDLE EXCEEDS 40 LBS. PERFORMED FUNCT TEST OF THE LT EMERGENCY EXIT IAW AMM…
- 27 May 2011
Doubler, cracked
LT SIDE FS 640.00 DOUBLER CRACKED AT CUTOUT RADIUS FOR ENGINE SUPPORT BEAM ATTACH POINT. REPAIRED.
- 27 May 2011
Attach Fitting, cracked
FS 625, OBLIQUE CLIP IS CRACKED. REMOVED CLIP IAW SRM 51-42-20. COMPLIED WITH EDDY CURENT INSP IAW NDTM 51-20-06, PART 1 53-00-096, PART 6 AND COMFIRMED…
- 16 Feb 2011
Warning System, activated
GEAR DISAGREE NOSE DOOR WARNING NOSE GEAR NEVER CAME UP DEFERRED PER MEL 32-30-01.
- 24 Oct 2010
Connector, dirty
DURING CLIMB, PASSING 27000FT CARGO BOTTLE LOW CAUTION MESSAGE CAUTION MESSAGE EXTINGUISHED DESCENDING THROUGH 11000FT. REMOVED, CLEANED, RESECURED CONNECTOR…
- 10 Sep 2010
Unknown, odor
FUMES IN COCKPIT/CABIN LED TO DIVERSION. APU OFF/BLEEDS ON ENGINES/SMELLED LIKE CIGARETTE BURNING/NO VISIBLE SMOKE. PERFORMED GROUND RUNS WITH BLEEDS ON…
- 7 Jun 2010
Selector Valve, malfunctioned
UPON CLIMBOUT AFTER THE CLIMB CHECK, HAD A GEAR DISAGREE MSTR WARNING. THE NOSE GEAR WAS THE ONE IN DISAGREEMENT. THE F/O START THE QRH, THE WARNING WENT…
- 11 Jul 2007
Ecu, faulty
FLIGHT 5011 - FLAP FAIL CAUTION RECEIVED ON TAXI OUT. RETURNED TO GATE. REPLACED FECU. NO FURTHER DEFECTS.
- 15 Mar 2007
Windshield, cracked
CAPTAIN'S WINDSHIELD INNER PANEL SHATTERED. PROCEEDED TO CVG WITHOUT INCIDENT. REPLACED CAPTAIN'S WINDSHIELD.
- 6 Feb 2007
Flap System, malfunctioned
FLIGHT 5115 - DURING YUL APPROACH RECEIVED A FLAP FAIL CAUTION MESSAGE. COMPLIED WITH AD 2006-12-21 FLAP CAUTION MESSAGE -FIRST EVENT- MAINTENANCE ACTION,…
- 26 Jan 2007
Shaft, damaged
FLIGHT 5510 - FLAP FAIL MESSAGE AT 8 DEGREES. LANDED WITHOUT INCIDENT. PERFORMED EO 27-046 AD INCLUDING FLAP SHAFT REJUVENATION. NO FURTHER DEFECTS.
- 18 Aug 2006
Skin Panel, cracked
PAX DOOR SECOND STEP DOWN FORWARD AND AFT SKINS CRACKED UNDER BRACKETS WHERE HAND RAILS STOW WHEN DOWN. AFT SKIN ALSO CRACKED THIRD STEP DOWN IN RADIUS OF…
- 28 Jan 2006
Generator, faulty
FLIGHT 5104 - CLIMBING OUT OF AUS DURING GEAR RETRACTION, THE AIR DRIVE GENERATOR DEPLOYED, FLIGHT RETURNED TO THE FIELD. REPLACED THE ADG AUTO DEPLOY CONTROL…
- 21 Mar 2005
Window, cracked
FLIGHT 5380 PILOTS SIDE WINDOW CRACKED. REPLACED PILOTS SIDE WINDOW.
- 22 Jan 2005
Hydraulic System, low
FLIGHT 5045 - DURING APPROACH TO BOS, RECEIVED A GEAR DISAGREE FOLLOWED BY A HYDRAULIC NR 3 LOW PRESSURE CAUTION, CREW DECLARED AN EMERGENCY, FOLLOWED QRH AND…
- 23 Apr 2004
Pitot Line, contaminated
FLIGHT 5208 ABORTED TAKEOFF AT 75 KTS DUE TO INOPERATIVE STANDBY AIRSPEED INDICATION. PURGED WATER FROM THE STANDBY PITOT SYSTEM LINE.
- 14 Jan 2004
Control Unit, malfunctioned
FLIGHT 5710 STAB TRIM AND MACH TRIM DISENGAGED DURING T/O. REPLACED THE HSTCU.
- 30 Dec 2003
Engine, fluctuates
FLIGHT 5732 N1 AND N2 AND F/F FLUCTUATING. COULD NOT DUPLCIATE. GROUND RUNS WERE NORMAL AND SATISFACTORY.
- 21 Sep 2003
Warning Light, illuminated
DURING DECENT INTO DTW RECEIVED A FLAP FAIL CAUTION MESSAGE AT 20 DEGREE FLAP POSITION. COMPLIED WITH AD 98-20-01 FLAP CAUTION MESSAGE (FIRST EVENT) FLAP…