A/C Pack, odor
PACK #2 EXPELLS UNPLEASANT SMELL.-IAW TSM 05-50-00-810-831A & AMM 21-00-00-615-802A PERFORMED DECONTAMINATION OF PACK 2, NO FURTHER SMELL NOTICED
- 25 Jul 2024
A/C Pack, odor
DURING THROUGH 25000 FT APPROX. FA REPORTED STRONG DIRTY SOCK SMELL IN AFT GALLEY. AFTER TURNIG PACK 2 OFF PER QRM PROCEDURE, SMELL WENT AWAY.-PER TSM…
- 12 Jun 2024
Unknown, odor
FUME EVENT ON DESCENT . DIRTY SOCKS SMELL NOTED --
- 12 Feb 2024
Engine, stalled
ENG 1 STALL IN CRUISE AT FL360-PERFORMED TSM 71-00-00-810-808-A STEPS 4.D 1-9. ENGINE POWER ASSURANCE PENDING.106057. PER TSM 71-00-00-710-013-2. HIGH POWER…
- 13 Nov 2023
Unknown, unknown
DURING CLIMB FA REPORTED A POSSIBLE FUME EVENT ONLY IN THE AFT GALLEY,WE SWITCHED PACK #2 OFF,WITH IN 5 MINUTES AIRCRAFT WAS NUTRILIZED,NO OTHER INDICATIONS,…
- 6 Jun 2023
Unknown, unknown
FUME EVENT.MUSTY SMELLPOSTGEAR EXTENTION ON APPROCH WITH APPLICATION OF LOWER APPROX1 MIN DURATION , UNABLE TO ISOLATE PACK-PREFORMED TSM 05-50-00-810-=A NO…
- 22 May 2023
Unknown, odor
STRONG DIRTY SOCK SMELL ON DESCENT APPROX 16000FT SMELL WAS PRESENT UNTIL PARKING-PERFORMED PACK BURN OUT OF PACK 1 AND 2 PER AMM 21-00-00. R/R RECIRCULATING…
- 29 Apr 2023
Unknown, unknown
FUME EVENT BELOW 6000FT, SMELL WENT AWAY WITH PACK 1 OFF.-PERFORMED TROUBLESHOOTING IAW TSM 05-50-00-810-831-A. FOUND PACK 1 TO BE CONTAMINATED. REF 3102468-2…
- 7 Apr 2023
Unknown, unknown
FUME EVENT ON APPROACH-PERFORMED TSM 05-50-00-810-831 REMOVED AND REPLACED RECIRCULATION FILTERS IAW AMM 21-21-41 AND REMOVED AND REPLACED L/H R/H OZONE…
- 6 Apr 2023
Unknown, unknown
FUME EVENT ON APPROACH TYHROUGH 10,000-PERFORMED TSM 05-50-00-810-831-1 FOUND PACK # 1 TO BE CONTAIMATED NO M ORE INSPECTION REQ A/C OK FOR SERVICE
- 16 Nov 2022
A/C Pack, odor
"FA'S REPORTED STRONG OILY ODER DECENDING THROUGH 7000FT. PACK 2 OFF. ODOR DISIPATED-ACCOMPLISHED TSM 05-50-00-810-831 FOR CABIN ODOR. PACKS RAN ON APU BLEED.…
- 14 Sep 2022
None, none
DIRTY SOCK SMELL IN COCKPIT ON DESENT ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 370 )--
- 6 Sep 2022
None, none
DIRTY SOCK SMELL ON DESCENT ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 370 )--
- 8 Mar 2022
None, none
LEAD FA REPORTED POSSIBLE FUME EVENT ON FINAL DECENT INTO MCO BELOW 10000'. NOT SMELLED IN COCKPIT, ONLY CABIN. SEVERAL PASSENGERS REPORTED COUGHING. FA(C)…
- 6 Feb 2022
Inlet, contaminated
STRONG WET SOCK SMELL BEGAN DURING DESCENT (12,000 FT APPROX). SMELL STAYED UNTIL SHUTTING ENGINE OFF AT THE GATE -ACCOMPLISHED TSM 05-50-00, PERFORMED ENG #1…
- 16 Jan 2022
Not Reported, not reported
FWD MEGAPHONE KNOB BROKEN-R&R FWD MAGEPHONE IAW NKS DRAWING A319-132 EMERGENCY EQUIPMENT.
- 22 Dec 2021
Unknown, odor
STRONG ODER IN COCKPIT DURING DECENT BELOW 10,000 DIRTY SOCK/GLUE SMELL FA DID NOT REPORT SMELL DIDNT MAKE A DIFFERANCE TURNING OFF PACKS AFT FA'S SMELLED A…
- 25 Oct 2021
Frame, cracked
FOUND DURING INSPCECTION OF FR16 UPPER DOUBLE JOGGLE AREA. HOLE #7 HAS CRACK. RAF 01 OPENED-ACCOMPLISHED REPAIR ON FRAME 16 UPPON JOGGIE HOLE #7 PER EO…
- 4 Sep 2021
A/C Pack, odor
IN CRUISE FLIGHT, FA B/C REPORTED DIRTY SOCK SMELL, SUSPECTING PACK 2 WE COMPLETED THE SUPP. PROCEDURE FOR FUMES/ ODORS. ONCE PACK 2 WAS OFF, FA'S REPLIED…
- 8 Aug 2021
Unknown, odor
POSSIBLE FUME EVENT AT 7000FT, DURING DECSENT. REAR OF CABIN, MUSTY-WET SOCK ODOR. NOTHING IN COCKPIT. ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND)…
- 7 Aug 2021
A/C Pack, odor
FA REPORTED FUME EVENT ON DESCENT IN AFT CABIN. TURNED OFF PACK 2 ODOR LESSENED. SMELLS LIKE VOMIT. ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND…
- 22 Jun 2021
Unknown, odor
FUME EVENT ON TAXI OUT-ACCOMPLISHED TSM 05-50-00-810-831. FOR CABIN ODOR. RAN BOTH PACKS ON APU BLEED ISOLATED PACKS NO SIGN OF CONTAMINATION. RAN BOTH ENG…
- 13 Jun 2021
Warning Message, false indication
HYD Y RSVR OVHT DURING DEPARTURE CLIMB. PERFOMED ECAM TURN OFF HYD PUMP #2 15-20 THE OVER WENT AWAY-PERFORMED INITIAL FLIGHT CONTROL OPERATION FOR 15 MIN, NO…
- 31 Mar 2020
Unknown, odor
ON FINAL A DIRTY SOCKS SMELL WAS REPORTED IN THE AFT GALLEY -PERFORMED CABIN ODOR TSM 05-50-00-810-851-A INSPECTION A/C EXTERNAL SURFACES NO EXTERNAL LEAKS…
- 2 Mar 2020
Unknown, fumes
FUME EVENT DURING LOW ALT DESCENT AND APPROACH RWY 06, SUSPECT LEFT PACK HAD 02 MASKS ON FOR LANDING-PERFORMED TSM 05-50-00-810-831-A. PERFORMED GVI OF A/C…
- 19 Feb 2020
Unknown, odor
ON DESCEND SMELL LIKE A GLUE BURN SMELL-PERFORMED TSM 05-50-00-810-831-A PERFORMED GVI OF ENGS AND APU IAW 71-00-00 & 49-16-00 NO LEAKS NOTED ISOLATED BOTH…
- 25 Oct 2019
A/C Pack, odor
STRONG ODOR DETECTED THROUGHOUT CABIN ON DESCENT SUSPECTED COMING FROM PACK1-ACCOMPLISHED TROUBLESHOOTING IAW TSM 05-50-00-810-831-A, ISOLATED FUME EVENT TO…
- 26 Sep 2019
Unknown, odor
DURING DESCENT THERE WAS A DIRTY SOCK SMELL IN THE COCKPIT/CABIN. THE ODOR DISSAPTED AFTER THE 31 PACK WAS TURNED OFF ( PACKS WITH MOD 31283/MP P7125 (FWC…
- 26 Sep 2019
Apu, odor
F/A REPORTED STRANGE SMELL IN AFT CABIN AFTER APU BLEED TURNED ON-PERFORMED TSM 05-50-00-810-831 AND FOUND APU TO BE SOURCE OF ODOR. REF OG PAGE 2389248-1 FOR…
- 14 Sep 2019
Unknown, odor
CABIN ODOR "DIRTY SOCK SMELL" IN THE CABIN AND COCKPIT ON DECENT INTO FLL.
- 13 Oct 2018
Door Sill, corroded
CORROSION FOUND AT LH DOOR SILL FRAME 16 STRINGER 23L & 23R MAX DAMAGE REFER TO APPENDIX 1 RAF 01 242927502 OPEN-REVEIWED EO 5311-1858 AND LTPR NR…
- 13 Oct 2018
Post, cracked
RT W/SHIELD CENTER POST HAS CRACK FR2 STR YO, REF LHTPR NRI 5000792917-0010. RAF01 2429277-1 OPEN FOR MAPPING PURPOSE ONLY-REVIEWED LTPR 5000792917-0010 AND…
- 13 Oct 2018
Post, cracked
LT AT FR 3-4 HAS CRACK AT SLIDING WINDOW SIDE POST RAF01 242927102 OPENED-REVIEWED EO 5311-1857 AND HAS BEEN ACCOMPLISHED.
- 14 Jan 2018
Unknown, odor
F/A REPORTED AN ODOR ON SHORT FINAL. STRONG ENOUGH TO BURN THE THROAT. PERFORMED AN OPS TEST OF THE NR 1 AND 2 PACKS. NO ODOR PRESENT IAW AMM 21-63-00-720 AND…
- 11 Jan 2018
Flashlight, inoperative
FLIGHT CREW REPORTED DURING WALKAROUND, THE FIRST OFFICER`S FLASHLIGHT WAS INOPERATIVE. R & R THE FLASHLIGHT IAW DRAWING N319-132-EQ, OPS CHECKED GOOD, NO…
- 3 Jan 2018
Adiru, malfunctioned
DURING DEPARTURE ROLL, ALTERNATE LAW ON LANDING AOA FAULT CA, FO, STBY, DIVERTED AND LANDED. RETRIEVED PFR PH04 ADIRU 1 FAULT, F/CTL ALTN LAW. APPLIED TSM…
- 20 Dec 2017
Unknown, odor
DURING DESCENT, FA SMELLED AN ELECTRICAL ODOR IN THE AFT GALLEY AREA. ALL EQUIPMENT OPERATED AND SHOWED FINE, THE ODOR WAS SHORT AND WENT AWAY . ISOLATED EACH…
- 11 Sep 2017
Controller, failed
CABIN WOULD NOT PRESSURIZE NORMALLY. AT 18,000', CABIN WAS CLIMBING AT 1400 PER MIN. AND CABIN ALTITUDE WAS AT 8200' AND CLIMBING. REMOVED AND REPLACED CPC1…
- 9 Sep 2017
Outflow Valve, failed
DURING CLIMB, CABIN PRESSURE EXCESSIVE RATE OF CLIMB OUT OF 18000. RATE 2800 FPM. CABIN ALTITUDE EXCEEDED 10000. FA REPORTED DEFLATING SOUND COMING FROM R2…
- 24 Jul 2017
Megaphone, inoperative
MEGAPHONE INOPERATIVE. REMOVED AND REPLACED THE MEGAPHONE IAW EMERGENCY REQUIP LAYOUT DRAWING.
- 28 Jun 2017
Hinge Fitting, corroded
RIGHT ELEVATOR HINGE ATTACH FITTING NR 4 HAS CORROSION. AFTER REPAIR, REAMED OUT OF LIMITS RAF 01 226204601. THE ELEVATOR HINGE FITTING WAS REPAIRD IAW EO…
- 1 May 2017
Computer, inoperative
LEFT AND RIGHT TRANSFER FUEL TANK DID NOT TRANSFER. R & R THE FUEL QUANTITY INDICATING COMPUTER (FQIC) IAW AMM 28-42-34-000-001-A/ 400-001-A. OPS CHECKED GOOD.
- 17 Apr 2017
Oxygen Mask, broken
NOTICED A SMALL TEAR ON THE SEAL OF THE CAPTAIN OXYGEN MASK. REMOVED AND REPLACED THE OXYGEN MASK IAW AMM 35-12-41. OPS CHECKED GOOD.
- 19 Feb 2017
Damper, unknown
AFTER R&R PASSENGER R1 DOOR SLIDE, UNABLE TO SERVICE EMERGENCY OPERATION CYLINDER DAMPER.
- 4 Jan 2017
Ecs, contaminated
FUME EVENT IMMEDIATELY AFTER T/O. ISOLATED BY SELECTING PACK NR 2 OFF. EVENT CONCLUDED. PERFORMED DECONTAMINATION OF THE NR 2 ENVIRONMENTAL CONTROL SYSTEM IAW…
- 29 Sep 2016
Oxygen Mask, unsecure
OXYGEN MASKS FELL ROW 8ABC. REPACKED ROW 8ABC OXYGEN MASKS AND PERFORMED DROP TEST IAW AMM 35-21-43. OPS TEST GOOD.
- 30 Jul 2016
Oxygen Bottle, unsecure
O2 MASK AFT GALLEY FELL OUT OF COMPARTMENT. PERFORMED THE OPS CHECK OF THE MANUAL MASK RELEASE IAW AMM 35-23-00. OPS CHECK GOOD.
- 17 Jul 2016
Oxygen Mask, unwanted deploy
AFTER TAKE OFF, AFT JUMPSEAT OXYGEN MASK COVER PANEL OPENED. REPACKED OXYGEN MASK ASSEMBLY IAW AMM 3521-43. PERFORMED OPS CHECK OF MANUAL MASK RELEASE IAW AMM…
- 3 Jun 2016
Apu, odor
FUMES IN CABIN AND COCKPIT DIRTY SOCK ODOR. NO EXTERNAL LEAKS FOUND. R & R APU IAW AMM 49-11-11. OPS & LEAK CHECKS GOOD.
- 15 Jan 2016
Megaphone, inoperative
AFT GALLEY MEGAPHONE INOPERATIVE. R & R MEGAPHONE AT AFT GALLEY OPS CHECKED OK IAW DWG NK319-132-EQ.
- 9 Aug 2014
Oxygen Mask, dislodged
OXYGEN MASK FELL IN AFT GALLEY. PERFORMED OPS CHECK OF MANUAL MASK RELEASE IAW AMM 35-23-00. OPS CHECK GOOD. NO FURTHER DISC. AT THIS TIME.
- 10 Jun 2014
Oxygen Mask, no test
FIRST OFFICER`S OXYGEN MASK WILL NOT TEST. R & R WITH SECOND OBSERVERS OXYGEN MASK, OPS OK IAW AMM 35-12-41.
- 20 Apr 2014
Battery Pack, inoperative
EPSU (13WL) AFT 2, BATTERY FOUND BAD DURING CABIN EMERGENCY LIGHTING BATTERY CAPACITY CHECK. R & R EPSU (13WL) AFT 2 BATTERY IAW AMM 33-51-38. OPS CHECK GOOD.
- 18 Apr 2014
Structure, corroded
CORROSION NOTED ON LT WING T/E AT RIB 10, DURING PHASED ARRAY INSPECTION. REMOVED CORROSION IAW SRM 51-74-00 AND DETERMINED TO BE OUT OF LIMITS IAW SRM…
- 18 Apr 2014
Structure, corroded
CORROSION NOTED ON LT WING T/E AT RIB-14 DURING PHASED ARRAY INSPECTION. REMOVED CORROSION IAW SRM 51-74-00 AND DETERMINED WITHIN ALLOWALBE LIMITS IAW SRM…
- 18 Apr 2014
Structure, corroded
CORROSION ON LT WING T/E RIB-15, DURING PHASED ARRAY INSPECTION. REMOVED CORROSION AND COMPLIED WITH REPAIR INSPECTION R572-58998.
- 18 Apr 2014
Structure, corroded
CORROSION ON LT WING T/E BETWEEN RIB-11 + RIB-12 DURING PHASED ARRAY INSPECTION. REMOVED CORROSION IAW SRM 51-74-00 AND DETERMINED TO BE WITHIN ALLOWABLE…
- 18 Apr 2014
Structure, corroded
CORROSION ON RT WING T/E RIB-7A DURING PHASED ARRAY INSPECTION. REMOVED CORROSION IAW SRM 51-74-00 AND COMPLIED WITH REPAIR INSTRUCTION R572-58998.
- 18 Apr 2014
Structure, corroded
CORROSION ON RT WING T/E BETWEEN RIB-11 AND RIB-12 DURING PHASED ARRAY INSPECTION. REMOVED CORROSION IAW SRM 51-74-00 AND COMPLIED WITH REPAIR INSTRUCTION…
- 18 Apr 2014
Rib, corroded
DURING SPECIAL DETAIL INSPECTION OF RT WING. CORROSION ON T/E RIB 10.
- 16 Jan 2014
Oxygen Mask, unwanted deploy
OXYGEN MASKS ABOVE 9B DEPLOYED. PERFORMED MAIN MASK RELEASE IAW AMM RESTOWED MASK IAW AMM. OPS CHECKED GOOD.
- 15 Dec 2013
Hose, inoperative
F/O FWD OXYGEN MASK HOSE INOPERATIVE. R & R F/O OXYGEN MASK IAW AMM.
- 24 Aug 2013
Oxygen Mask, faulty
CAPTAIN`S OXYGEN MASK WILL NOT INFLATE FULLY. R & R OXYGEN MASK. OPS CHECKED OK IAW AMM.
- 10 Jun 2013
Oxygen Mask, unwanted deploy
F/A FWD JUMPSEAT O2 MASKS DEPLOYED ON LANDING. PERFORMED FNC CK OF AUTOMATIC MASK RELEASE IAW ACFT MM, OPS CK GOOD.
- 1 Feb 2013
Seal, dirty
F/A REPORTS LOUD SQUEAL FROM L1 DOOR ON DESCENT AND CLIMB. INSPECTED DOOR AND DOOR SEAL IAW ACFT MM. FOUND DEBRIS ON LOWER SEAL. CLEANED SEAL AS REQ’D. DOOR…
- 3 Jan 2013
Door, noisy
ACFT RT OVERWING EMERGENCY EXIT MAKING A LOUD SQUEAL. R & R DOOR IAW ACFT MM. INSPECTED DOOR SEAL, FOUND SEAL TO BE IN GOOD CONDTION. PERFORMED PRESSURE TEST,…
- 11 Oct 2012
Attach Fitting, worn
DURING STRUCTURE INSPECTION, FOUND THE LT WING AILERON INBD SERVO CONTROL ATTACH FITTING WORN.
- 9 Oct 2012
Fitting, corroded
DURING INSPECTION, FOUND THE RT AND LT MLG RETRACTION JACK ANCHORAGE FITTING CORRODED. THE FITTING WAS REPAIRED IAW 70567813/007.
- 2 Oct 2012
Skin, corroded
DURING INSPECTION, FOUND VERTICAL STABILIZER, RUDDER RT EXTERNAL SKIN BULGED AT NR 7 POSITION HINGE. THE SKIN WAS REPAIRED IAW 70567897/006 .
- 29 Jul 2011
Cylinder, low pressure
L2 DOOR ACCUMALATOR NEEDS SERVICED. SERVICED L2 DOOR IAW AMM 52-10-00-614-001.
- 25 Feb 2011
Floor Support, corroded
UPPER FUSELAGE PAX CABIN AFT ENTRANCE AREA FROM STA 2800 TO STA 2872 BETWEEN +Y116 TO +Y129 FLOOR SÙPPORT BEAM WITH CORROSION. CORRECTIVE ACTION: DAMAGED PART…
- 25 Feb 2011
Floor Support, corroded
UPPER FUSELAGE PAX CABIN AFT ENTRANCE AREA FROM STA 2800 TO STA 2872 BETWEEN -Y116 AND -Y129 FLOOR SUPPORT BEAM WITH CORROSION. DAMAGED PART WAS REPLACED IN…
- 25 Feb 2011
Seat Track, corroded
UPPER FASELAGE PAX CABIN AFT ENTRANCE AREA STA 2786, +Y129 SEAT TRACK WITH CORROSION. CORRECTIVE ACTION: DAMAGE PART IS GOING TO BE REPLACED BY A NEW PART IN…
- 26 Oct 2010
Cabin Pressure, failed
ACFT LOST CABIN PRESSURIZATION DUE TO DUAL BLEED LOSS. DIVERTED.