N524DA
2015 Cirrus Design Corp SR22 standard FAA →
registration
- 2015
earlier registrations
1 past record
- 1979
service difficulty reports
46 reports
- 7 Nov 2001
Light, inoperative
BOTH AFT SERVICE DOOR SLIDE LIGHTS INOP. RELAMPED BOTH BULBS AND REPLACED BATTERY PACK FOR M983.
- 28 Oct 2001
Light, inoperative
FWD EMERGENCY EXIT LIGHT INOP. REPLACED LIGHT ASSY.
- 31 Aug 2001
Skin, corroded
FUSELAGE / SKIN / FS 1070-1090 / STRG. 27R-29R : CORROSION CUTOUT REPAIR THE FUSELAGE SKIN WAS FOUND CORRODED BETWEEN FS 1070 & 1090 AND BETWEEN STRINGERS 27R…
- 31 Aug 2001
Sill, corroded
FUSELAGE C2 DOOR OPENING LOWER SILL OUTER CHORD WAS FOUND WITH AN AREA OF CORROSION ON THE OUTBD SKIN FLANGE NEAR FS 950E+10. THE CORROSION WAS MACHINED AWAY…
- 31 Aug 2001
Skin, corroded
FUSELAGE / SKIN / FS 1150 / STRG. 29R : CORROSION REPAIR THE FUSELAGE SKIN WAS FOUND WITH A SMALL AREA OF CORROSION JUST AFT OF THE FS 1150 FRAME AND JUST…
- 24 Aug 2001
Frame, cracked
FUSELAGE FRAME AT FS 970 STR 26L-27L. THE FS 970 FRAME INNER CHORD WAS FOUND CRACKED AT A FLOOR ATTACH LOCATION BETWEEN STRINGERS 26L AND 27L. THE CRACK IS…
- 14 Jun 2001
Flap, stuck
INBD FLAPS WONT RETRACT STUCK AT 15 DEGREES - LUBED AND RAN FLAPS - UNABLE TO DUPLICATE
- 5 May 2001
Wire, broken
CAPT O2 MASK MICROPHONE WIRE BROKEN. REPLACED MASK.
- 21 Mar 2001
Transmitter, failed
NBR 2 ENG OIL PRESSURE READ IN RED ON CLIMBOUT FROM OMA. REPLACED OIL PRESSURE TRANSMITTER
- 5 Mar 2001
Skin, torn
THE FUSELAGE SKIN AND UNDERLYING TRIPLER WERE BADLY DAMAGED BY GROUND EQUIPMENT AT AN OUTFLOW VALVE CUTOUT BETWEEN FS 1166 & 1183 AND BETWEEN STRINGERS 26R &…
- 2 Jul 2000
Door, malfunctioned
AFTER TAKE-OFF, WHEN GEAR LEVER WAS MOVED TO -OFF- POSITION RT MAIN GEAR DOOR RE-OPENED. LEVER WAS MOVED TO -UP- AND DOOR CLOSED. RETURNED LEVER TO -OFF- AND…
- 30 May 2000
Sign, inoperative
L2 SVC DOOR OVERHEAD EMERGENCY EXIT SIGN INOP. REPLACED LIGHT RACK.
- 2 May 2000
Bulkhead, cracked
THE FS 1183 BULKHEAD WAS FOUND WITH A 1.5 INCH LONG TYPICAL CRACK IN THE WEB JUST BELOW THE LBL & RBL 8 STIFFENERS AT WL 182. THE CRACKS ARE TYPICAL OF BAC…
- 1 May 2000
Web, cracked
FOUND ON B1 LETTER CK, .5 INCH CRACK AT RT TORQUE BOX VERTICAL WEB UPPER LIGHTENING HOLE STA 1323. REPAIRED PER MM 53-11-0.
- 1 May 2000
Stiffener, cracked
A 2 INCH CRACK IN NR 3 SLAT O/B TRACK O/B SPAR STIFFENER. REPLACED STIFFENER PER M/M 57-20-21.
- 15 Mar 2000
Battery Pack, discharged
EMERGENCY LIGHT INOP AT R2 DOOR DURING SVC CHECK. REPLACED BATT PACK, OPS CKS OK.
- 22 Aug 1999
Battery, discharged
L1 EMERGENCY EXIT DOOR LIGHT BATTERY WOULD NOT TEST. REPLACED BATTERY.
- 5 May 1999
Skin, cracked
LFEC INSPECTION OF THE STRINGER 4R SKIN LAP SPLICE BETWEEN FS 481 AND 681 INDICATED CRACKS IN THE LOWER FASTENER ROW OF THE LOWER PANEL. INTERNAL HFEC…
- 5 May 1999
Skin, cracked
LFEC INSPECTION OF THE STRINGER 4R SKIN LAP SPLICE BETWEEN FS 680 AND 740 INDICATED CRACKS IN THE LOWER FASTENER ROW OF THE LOWER SKIN PANEL. INTERNAL HFEC…
- 8 Apr 1999
Light, inoperative
EMERGENCY EXIT LIGHT IN BETWEEN OVERWING EXITS INOP. REPLACED LIGHT ASSY.
- 15 Feb 1999
Slide, dislodged
DURING TAKEOFF ROLL, L1 SLIDE PACK DISLODGED FROM DOOR. ACFT RETURNED TO BLOCK. RESECURED SLIDE PACK, CKS NORMAL.
- 4 Feb 1999
Skin, damaged
DURING SHOP INSPECTION, A HOLE WAS FOUND IN COVE SKIN PANEL AT 2ND FROM I/B AFT FLAP TRACK. THE SKIN WAS REPAIRED PER MM 57-52-0, FIG 809.
- 1 Feb 1999
Bulkhead Ring, damaged
DURING INITIAL INSPECTION, A FASTENER AFT OF BS 1183 AT RBL 24 WAS FOUND LOOSE. DURING REMOVAL OF THE FASTENER, TOOLING DAMAGE WAS DONE TO THE TENSION FITTING…
- 1 Feb 1999
Skin, damaged
EXISTING TRIM OUTS AND ADDITIONAL GROUND DAMAGE WAS FOUND IN THE SKIN AT THE AFT EDGE OF THE C2 DOOR CUTOUT AT BS 990. THE DAMAGED AREAS ARE NEAR S24R.…
- 1 Feb 1999
Stringer, damaged
S7L WAS GOUGED DURING INSTALLATION OF NEW GALLEY, DAMAGE IS IN INNER RADIUS AT BS 1018. REPAIRED PER ERA 332697-14.
- 20 Jan 1999
Skin, worn
DURING SHOP INSPECTION, THE COVE SKIN WAS FOUND WORN 35 FROM O/B END OF FLAP. A REPAIR DOUBLER WAS INSTALLED PER MM 57-52-0, FIG 809.
- 20 Jan 1999
Skin, damaged
DURING SHOP INSPECTION, THE AFT COVE SKIN WAS FOUND WITH TOOL DAMAGE 60 FROM O/B END. THE SKIN WAS REPAIRED BY INSTALLING A DOUBLER PER MM 57-52-0 PAGE 819.
- 20 Jan 1999
Skin, cracked
DURING SHOP INSPECTION, THE COVE SKIN WAS FOUND CRACKED AT 35 FROM THE I/B END. THE COVE SKIN WAS REPAIRED BY INSTALLING A DOUBLER PER MM 57-52-0 FIG 809.
- 11 Jan 1999
Skin, damaged
DURING SHOP INSPECTION THE COVE SKIN WAS FOUND TO HAVE A TEMPORARY REPAIR INSTALLED 34 FROM I/B END OF FLAP. THE SKIN WAS REPAIRED BY INSTALLING A PERMANENT…
- 11 Jan 1999
Skin, cracked
DURING SHOP INSPECTION, THE COVE SKIN WAS FOUND CRACKED 31 INCHES FROM I/B END. A REPAIR DOUBLER WAS INSTALLED PER MM 57-52-0, FIG 809.
- 11 Jan 1999
Blkhd Stiffener, cracked
A CRACK WAS FOUND IN THE LBL 36.83 VERT STIFFENER ON THE FWD SIDE OF THE BS 1183 BLKHD. CRACK IS LOCATED APPROX AT WL 238 AND IS APPROX 2 IN LENGTH. REPAIRED…
- 5 Jan 1999
Spar, cracked
CRACKS AT AFT SPAR RAIL AT 18, 32 & 61 FROM I/B END OF FLAP. REPAIRED ON N/R'S 010525, 010526 & 010527. REPAIRS WERE PERFORMED PER M/M 57-52-0 FIG 802 . ON…
- 4 Jan 1999
Skin, worn
DURING SHOP INSPECTION, THE LEADING EDGE WAS FOUND WORN AT THE O/B END OF FLAP. THE DAMAGE WAS REMOVED AND A DOUBLER AND FILLER INSTALLED PER MM 57-52-0, FIG…
- 21 May 1998
Web, cracked
FOUND AT A-1 LETTER CHECK, VERT TORQUE BOX WEB CRACKED .625 AT UPPER LIGHTENING HOLE STA 1285 RT. REPAIRED PER M/M 53-11-0.
- 16 Oct 1997
Web, cracked
FOUND ON F2 LETTER CK, .75 INCH CRACK LOWER RT CORNER OF WEB STA 1303 ABOVE NR 2 ENGINE S-DUCT. REPAIRED PER SRM 53-10-4.
- 16 Oct 1997
Chord, cracked
FOUND ON F-2 LETTER CK, LT ATTACH CHORD CRACKED .75 INCH AT VERTICAL STAB S-7L. REPAIRED PER MM 55-30-0.
- 6 Oct 1997
Actuator, leaking
AFTER T/O AT 5,000 FT, A-SYS HYD QTY WENT TO ZERO. REPLACED NR 3 L/E FLAP ACTUATOR.
- 28 Aug 1997
Light, inoperative
OVERHEAD EMERGENCY LIGHT AT 1L DOOR INOP. REPLACED EMERGENCY LIGHT ASSY AT 1L DOOR, CKS OK. FOUND ON L/O CK.
- 12 Mar 1997
Skin, damaged
THE L-1 DOOR HINGE CUT-OUTS WERE FOUND TO HAVE EXISTING DOUBLER REPAIRS INSTALLED. THE DOUBLERS WERE INSPECTED AND IDENTIFIED AS PERMANENT PER BACO S/B…
- 11 Mar 1997
Bulkhead Support, worn
FOUND DURING MV2 F1 - STA 720D VERTICAL BULKHEAD SUPPORTS WORN AT UPPER ATTACH POINTS LT ABOVE STRINGER 26 LT AND RT ABOVE STR 26 RT. INSTALLED REPAIR PER SRM…
- 11 Mar 1997
Floorbeam, corroded
FLOO BEAM CAP CORRODED STA 344 AT RBL 6. REPAIRED PER SRM 53-10-8 FIG 11.
- 10 Mar 1997
Mount Bracket, cracked
FOUND DURING MV2F1, TOP I/B CORNER CRACKED ON NR 5 L/E FLAP ACTUATOR MOUNT BRACKET. FABRICATED REPAIR PER M/M 57-20-21 AND LEAK CHECKED.
- 27 Mar 1996
Closing Mech, broken
ON ARRIVAL AT GATE, THE FWD LT ENTRY DOOR WOULD NOT OPEN. FOUND SEVERAL BROKEN PARTS JAMMING UPPER HINGE AND LOWER CAM PLATE, UPPER HINGE WAS LOOSE IN AT…
- 10 Nov 1995
Batteries, discharged
AFT AISLE EMERGENCY FLOOD LIGHT INOP. REPLACED BATTERIES IN AFT AISLE EMERGENCY FLOOD LIGHT, CHECKS NORMAL.
- 14 Jul 1995
Nose Rib, cracked
FOUND DURING D-2 LETTER CHECK, NR 4 L/E SLAT ACT ATTACH RIB CRACKED 1.75 INCH I/B SIDE. REPAIRED PER MM 57-54-0.
- 2 Jan 1995
Ribs, cracked
DURING SHOP INSPECTION, LEFT WING NR 3 SLAT WAS FOUND WITH NR 3, NR 7, NR 9 AND NR 10 RIBS CRACKED. REPAIRED PER SRM 57-50-3 AND SRM 57-54-0 FIG 804.