N523AS
2009 Boeing 737-890 standard FAA →
registration
- 2009
service difficulty reports
76 reports
- 14 Jun 2026
Door, no discrepancy
L1 DOOR UPPER HINGE COVER (INSIDE) JAMS OPEN WHEN CLOSING DOOR. F/A REPORTS COVER WILL CLOSE NORMALLY BY CYCLYING DOOR PARTIALLY OPEN THEN RE-CLOSING.…
- 10 Sep 2025
Landing, gouged
PANEL 193B RT SIDE OTBD, PANEL LANDING GOUGED. GROUNDED - YES. REMOVED & REPLACED PANEL 193 RT SIDE OTBD PANEL LANDING IAW SRM 51-40-02-0G-0.
- 4 Sep 2025
Support Angle, corroded
FWD CARGO PIT LH SIDE AFT BULKHEAD LOWER SUPPORT ANGLE HAS MULTIPLE SPOTS OF CORROSION AND BARE METAL. GROUNDED - YES. REMOVED AND REPLACED FWD CARGO PIT L/H…
- 2 Sep 2025
Angle, cracked
UPON GVI OF LT AC BAY FOUND STA 663 CENTER SECTION REAR SPAR ANGLE CRACKED. GROUNDED - YES. REMOVED DAMAGE, AND REAPIRED IAW SRM 57-10-10-2R-5.
- 26 Aug 2025
Strap, corroded
AFT WET AREA FLOOR STRAP AT STA 1016 LBL 3 HAS CORROSION. GROUNDED - YES. REMOVED & REPLACED AFT WET AREA FLOOR STRAP AT STA 1016 LBL 3 IAW B737-800 SRM…
- 26 Aug 2025
Strap, corroded
AFT WET AREA FLOOR STRAP AT STA 1016 RBL 3 HAS CORROSION. GROUNDED - YES. REMOVED & REPLACED AFT WET AREA FLOOR STRAP AT STA 1016 RBL 3 IAW B737-800 SRM…
- 26 Aug 2025
Floor Support, corroded
AFT WET AREA FLOOR SUPPORT FROM STA 947 TO STA 967 RBL 47 HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED ON AFT WET AREA FLOOR SUPPORT FROM STA 947- 967…
- 22 Aug 2025
Rib, cracked
LEFT HORIZONTAL STAB RIB NR 6 IS CRACKED. GROUNDED - YES. REPAIRED THE LT HORIZONTAL STAB RIB NR 6 IAW SRM 55-10-09-2R-4.
- 22 Aug 2025
Rib, cracked
LEFT HORIZONTAL STAB RIB NR 2 CRACKED. GROUNDED - YES. REPAIRED LT HORIZONTAL STAB RIB NR 2 IAW SRM 55-10-09-2R-4.
- 21 Aug 2025
Landing, gouged
PANEL 193B RH AFT OB PNL LANDING GOUGED. GROUNDED - YES. REMOVED AND REPLACED PANEL 193D RH AFT PNL LANDING IAW SRM 51-40-02-0G-0 W= 1 O= .100 R= .084 L= 1…
- 21 Aug 2025
Landing, gouged
PANEL 193B LH OTBD PANEL LANDING GOUGED. GROUNDED - YES. REMOVED & REPLACED PANEL 193B LEFT OTBD PANEL LANDING IAW SRM 51-40-02-0G-0.
- 20 Aug 2025
Transition Panel, corroded
FWD CARGO RH TRANSITION HAS CORROSION FROM STA 500A TO STA 500I. GROUNDED - YES. REMOVED & REPLACED FWD CARGO RH TRANSITION FROM STA 500A TO STA 500I IAW…
- 20 Aug 2025
Strap, corroded
AFT CARGO PIT STRAP IB OF LOWER SILL WEB AT STR 24 HAS AREAS OF CORROSION FROM STA 787 TO STA 807. GROUNDED - YES. REMOVED & REPLACED AFT CARGO PIT STRAP IB…
- 20 Aug 2025
Transition Panel, corroded
FWD CARGO LH TRANSITION HAS SCRIBE MARKS AND GOUGES FROM STA 480 TO STA 500D. GROUNDED - YES. REMOVED & REPLACED FWD CARGO LH TRANSITON FROM STA 480 TO STA…
- 20 Aug 2025
Transition Panel, corroded
AFT CARGO LH TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION FROM STA 727 TO STA 767. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO LH TRANSITION FROM STA…
- 20 Aug 2025
Transition Panel, corroded
AFT CARGO RH TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION FROM STA 727 TO STA 787. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO RH TRANSITION PANEL FROM…
- 20 Aug 2025
Shield, corroded
AFT CARGO DOOR SHIELD FWD OF DOOR HAS AREAS OF CORROSION. GROUNDED - YES. REMOVED & REPLACED AFT CARGO DOOR SHEILD FWD OF DOOR IAW B737-800 SRM 51-40-02-0G-0.…
- 20 Aug 2025
Skin, cracked
RIGHT HORIZONTAL STAB LOWER SKIN IS CRACKED ON THE I/B SIDE OF STA 138.70 APPROX 9 INCHES FROM FRONT SPAR. GROUNDED - YES. REPAIRED RIGHT HORIZONTAL STAB SKIN…
- 20 Aug 2025
Cargo Track, cracked
AFT CARGO RT CARGO TRACK CRACKED AT STA 727G AND 727J. GROUNDED - YES. REPAIRED AFT CARGO R/H CARGO TRACK AT STA 727G AND 727J IAW B737-800 SRM 53-00-53-2R-3.
- 20 Aug 2025
Skin, cracked
RIGHT HORIZONTAL STAB LOWER SKIN IS CRACKED ON THE INBD SIDE OF HSS 129.560 APPROX 24 INCHES FROM FRONT SPAR. GROUNDED - YES. REPAIRED RT HORIZONTAL STAB…
- 20 Aug 2025
Support, corroded
FWD CARGO AFT BULKHEAD RT SIDE LOWER SUPPORT HAS CORROSION AND BARE METAL. GROUNDED - YES. REMOVED AND REMPLACED FWD CARGO AFT BULK HEAD RH SIDE LOWER SUPPORT…
- 20 Aug 2025
Cargo Track, corroded
AFT CARGO RH CARGO TRACK HAS SCRIBE MARKS AROUND CARGO TIEDOWNS AND AREAS OF CORROSION NEAR STA 787. GROUNDED - YES. REPAIR AFT CARGO RH CARGO TRACK IAW SRM…
- 20 Aug 2025
Skin, cracked
LEFT HORIZONTAL STAB LOWER SKIN IS CRACKED ON THE I/B SIDE OF STA 147.90 APPROX 8 INCHES FROM REAR SPAR.262A001. GROUNDED - YES. REPAIRED LEFT HORIZ STAB LWR…
- 5 Sep 2024
Battery Pack, failed
WHILE PERFORMING T.C. #78233001, EMERGENCY LIGHT BATT PACKS REQUIRE REPLACEMENT X3. GROUNDED - YES. REMOVED AND REPLACED BATT PACK AND CHARGER AT M1670,…
- 7 Sep 2023
Frame, corroded
RUDDER LH SIDE SURFACE HAS SIGNS OF CORROSION NEAR FWD SIDE OF STATIC WICK BASE 3RD FROM THE TOP. GROUNDED - YES. REPAIRED DAMAGE SKIN ON L/H SIDE OF RUDDER…
- 6 Sep 2023
Battery Pack, inoperative
AFT INTERIOR AND EXTERIOR EMERGENCY EXIT LIGHTS NEAR AFT ENTRY DOOR INOP. GROUNDED - YES. REMOVED & REPLACED BATTERY PACK MIG 72 ON LOG PAGE 60618032. OPS…
- 17 Aug 2023
Skin, cracked
R/H HORIZONTAL STABILIZER LOWER SKIN HAS A 2.5" CRACK INDICATION AT THE REAR SPAR LOCATED AT STAB. STA. 95". AS MARKED. GROUNDED - YES. REPAIRED RIGHT HAND…
- 17 Aug 2023
Skin, cracked
L/H HORIZONTAL STABILIZER LOWER SKIN HAS A CRACK INDICATION 1/2" IN LENGTH AT STAB. STATION 101.90. LOCATED 19.50" FROM FRONT SPAR. AS MARKED. GROUNDED - YES.…
- 13 Oct 2022
Battery Pack, failed
WHILE PERFORMING ASA TASK CARD 78233001, 2X EMERGENCY LIGHT BAT PACKS FAIL FUNCTION CHECK. GROUNDED - YES. REMOVED AND REPLACED EMERGENCY LT POWER SUPPLY AND…
- 27 Sep 2021
Skin, dented
DURING DEFERRED ITEM REVIEW, FOUND PLT DEFECT 300009862 REQUIRES RE-EVALUATION FOR CORRECT DEFECT CATEGORY ( REPAIR DOUBLER IN LH PRIMARY STATIC PORT RVSM…
- 2 Jul 2021
Skin, cracked
R/H HORIZ STAB LWR SKIN CRACKED @ 2 PLACES, STAB STA 147.7, 23.5"-25.5" AND 31"-32.5" AFT OF FRONT SPAR GROUNDED - YES. REPAIRED I.A.W. SRM 55-10-01-2R-11…
- 30 Jun 2021
Skin, cracked
R/H HORZ. STAB LWR SKIN CRACKED @ STAB STA 1001.7, 36.75"- 38.5" AFT OF FRONT SPAR. GROUNDED - YES. REPAIRED I.A.W. B737-800 SRM 55-10-01-2R-11 REPAIR 11
- 5 Apr 2021
Power Supply, no test
LH FWD EXIT ESCAPE DOOR EMERGENCY LIGHT INOP. GROUNDED - YES. REMOVED & REPLACED M2335 (EMERGENCY POWER SUPPLY) REF B737-800 AMM 33-51-06 OPS NORMAL.
- 7 Feb 2020
Lens, detached
EMERGENCY ROW EXIT LIGHT HANGING FROM CEILING. GROUNDED - YES. REINSTALLED MID CABIN EMERGENCY EXIT SIGN IAW B737-800 AMM 33-51-01 - SIGN OPS OK.
- 2 Dec 2019
Bulb, burned out
R/H FWD OVERWING EXIT LIGHT INOP. GROUNDED - YES. RELAMPED R/H FWD OVERWING EXIT SIGN LAMP, OPS CHECK GOOD REF B737-800 AMM 33-51-01.
- 15 Oct 2019
Handle, binding
FA REPORTS L1 DOOR DIFFICULT TO CLOSE AND HANDLE GOT STUCK BEFORE DOOR WAS FULLY CLOSED. GROUNDED - YES. OPERATED L1 DOOR SEVERAL TIMES, ALL OPERATIONS &…
- 13 Oct 2019
Light, inoperative
EMERGENCY LIGHT AISLE LIGHT INOP AT ROW 24 RIGHT. GROUNDED - YES. REMOVED, REPLACED, AND TESTED EMERGENCY LIGHT AISLE LIGHT ASSY AT ROW 24 RIGHT PER AMM…
- 24 Sep 2019
Battery Pack, failed
EMERGENCY LIGHT SYSTEM OPERATIONAL TEST WITH COCKPIT SWITCH FAILED FOR FORWARD RIGHT SIDE GROUNDED - YES. REMOVED AND REPLACED EMERGENCY POWER SUPPLY M1676…
- 22 Sep 2019
Light, inoperative
R1 DOOR HEADER PANEL HAS INOP EMERGENCY LIGHT. GROUNDED - YES. REMOVED AND REPLACED R1 DOOR HEADER PANEL EMERGENCY LIGHT M1674 IAW AMM 33-51-06, SYSTEMS…
- 12 Sep 2019
Channel, corroded
FORWARD PIT RT SIDE ZEE CHANNEL CONTAINS SEVERAL SPOTS OF CORROSION FROM STATION 500B TO 500E. GROUNDED - YES. REMOVED DAMAGED ZEE CHANNEL SECTION FROM…
- 5 Sep 2019
Bracket, cracked
FORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500G AFT SIDE, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET…
- 5 Sep 2019
Transition Panel, cracked
AFT CARGO RT TRANSITION PANEL CRACKED STA 727H. GROUNDED - YES. AFT CARGO RT TRANSITION PANEL EVALUATED AND FOUND TO BE OUT OF LIMITS IAW 53-00-53-1A-2…
- 5 Sep 2019
Bracket, cracked
FORWARD PIT LT SIDE HAS ANGLE BRACKET CRACKED AT LBL 23 APPROX STATION 500H, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET LOCATED AT…
- 4 Sep 2019
Shield, corroded
FORWARD FLOOR SUPPORT SHIELD IN FORWARD PIT RT SIDE IS CORRODED (STATION 500 RBL 24 APPROX.). GROUNDED - YES. BLENDED CORROSION FROM SHIELD IN FWD PIT RT SIDE…
- 4 Sep 2019
Bracket, cracked
FORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500H, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET AND…
- 4 Sep 2019
Bracket, cracked
FORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500F, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET AT FWD PIT…
- 4 Sep 2019
Bracket, cracked
FORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500G, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET LOCATED AT…
- 4 Sep 2019
Floorbeam, damaged
FLOORBEAM @ STA 727I LH HAS PULLED THRU FASTENED- DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED AND REPLACED DAMAGED ZEE CHANNEL SECTION FROM LT STA 727 TO…
- 4 Sep 2019
Shield, corroded
FLOORBEAM TRANSITION PLATE RT FROM STA 767 TO STA 787 IS CORRODED. DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED CORRODED SHIELD FROM BS767-BS787, LOCATED…
- 4 Sep 2019
Door Sill, corroded
AFT CARGO DOOR SILL PLATE HAS SEVERAL AREAS CORRODED - DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED AND REPLACED (WEB) DOOR SILL PLATE REF BAC DRWG…
- 4 Sep 2019
Splice Plate, corroded
FRAME BEEF UP PLATE & SUB STRUCTURE RH @ STA 787 IS CORRODED - DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED AND REPLACED CORRODED FRAM SPLICE PLATE @…
- 3 Sep 2019
Intercostal, cracked
MAIN CABIN FLOOR STRUCTURE INTERCOASTAL CRACKED AROUND FASTENER HOLE AREA (CRACK IS ON TOP AND BOTTOM) BETWEEN STATION # 277 AND 294 AT RBL 1. GROUNDED - YES.…
- 3 Sep 2019
Pan, corroded
WATER SERVICE DOOR #146AR INNER PAN (2EA) AREA CORRODED. GROUNDED - YES. REMOVED AND REPLACED INNER PAN PN 147A7221-30 REF BAC DWG 147A7221 REV "D" AND SRM…
- 28 Aug 2018
Battery Pack, no test
WHILE PERFORMING T/C 78233001, FOUND THE EMERGENCY LIGHTS DID NOT PASS A CAPACITY TEST, OVERWING, AFT EXIT, EXTERNAL LEFT AND RIGHT, LEFT AND RT OVERHEAD BIN…
- 26 Jul 2018
Light, inoperative
RT FWD OVERWING EMERGENCY LIGHT INOP. GROUNDED - YES. RELAMPED RT FWD OVERWING EMERGENCY LIGHT REF AMM 33-51-04 OPS CHECK GOOD.
- 6 Feb 2018
Lamp, failed
EMERGENCY LIGHT INOPERATIVE AT THE OVERWING EXTERIOR FWD RT. ACFT GROUNDED. REPLACED THE LAMPS, OPS CHECKED NORMAL IAW AMM 33-51-04-960-801.
- 24 Jul 2017
Unknown, odor
REACHING TOP OF CLIMB AT FL350, AFT FLT ATTENDANTS REPORTED A METALLIC ODOR STARTING AT THE L2 DOOR AREA AND CONTINUING TO ROW 24. THE ODOR WAS STRONGEST ON…
- 15 Feb 2017
Lamp, inoperative
EMERGENCY LIGHT EXTERIOR SLIDE LIGHT AT THE R2 DOOR WAS INOPERATIVE. ACFT GROUNDED. VERIFIED 6.2 VDC AT L733 SLIDE LIGHT AND GOOD GROUND FOR LIGHT. REPLACED…
- 26 Sep 2015
Floorbeam, cracked
MAIN DECK FLOORBEAM CRACKED. BS 540, BL 0 - LBL 5. ACFT GROUNDED. REMOVED CRACKED FLOORBEAM IAW SRM 51-40-02 LOCATED, DRILLED, AND INSTALLED NEW FLOORBEAM IAW…
- 26 Sep 2015
Floor Support, cracked
MAIN CABIN FLOOR SUPPORT CRACKED, BS 344-360, BL 0. ACFT GROUNDED. R & R FLOOR SUPPORT IAW SRM 51-40-02 AND DWG 141A5410, REV.
- 26 Sep 2015
Floorbeam, cracked
MAIN DECK FLOORBEAM ANGLE CRACKED. MARKED & DOTTED. BS 540, BL 0 - RBL 5. ACFT GROUNDED. REMOVED CRACKED FLOORBEAM ANGLE IAW SRM 51-40-02. LOCATED, DRILLED,…
- 26 Sep 2015
Floor Support, cracked
MAIN CABIN BS 285-294.5, BL 0 FLOOR SUPPORT CRACKED. ACFT GROUNDED. R & R IAW SRM 51-40-02 AND DWG 141A5400, REV.
- 26 Sep 2015
Web, corroded
MAIN CABIN AFT FLOOR WEB, UPPER SURFACE, CORRODED, DOTTED,BS 986 - 988, RBL 30 - 45. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51-1A-1, FOUND TO BE…
- 26 Sep 2015
Floor Support, cracked
MAIN CABIN BS 312-328, RBL 44 FLOOR SUPPORT CRACKED. ACFT GROUNDED. R & R THE FLOOR SUPPORT IAW SRM 51-40-02 AND BAC DWG 141A5410 REV A.
- 26 Sep 2015
Floor Support, cracked
MAIN CABIN BS 344-360, LBL 12 FLOOR SUPPORT CRACKED. ACFT GROUNDED. REMOVED AND INSTALLED A NEW FLOOR SUPPORT IAW SRM 51-40-02 AND DWG 141A5410, REV E.
- 26 Sep 2015
Floor Support, cracked
MAIN CABIN BS 312-328, LBL 48 FLOOR SUPPORT CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, PARA 7 AND DWG 141A5400, REV -.
- 26 Sep 2015
Door Sill, corroded
AFT CARGO DOOR SILL CORRODED BS 794 - BS 847, BL R24. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02, ORIGINAL .050 REMOVED .005 REMAINING .045 FOUND TO BE…
- 23 Sep 2015
Skin, cracked
CRACK FOUND .840" LONG, 8" FWD OF AFT SPAR, RT HORIZONTAL LOWER SKIN INBD OF STABILIZER BS 184.70. ACFT GROUNDED. REPAIRED LOWER SKIN OF RT HORIZONTAL LOWER…
- 23 Sep 2015
Skin, cracked
CRACK FOUND .740" LONG, 8.5" FWD OF AFT SPAR, RT HORIZONTAL LOWER SKIN INBD OF STABILIZER, BS 138.70, MARKED. ACFT GROUNDED. REPAIRED LOWER SKIN ON RT…
- 23 Sep 2015
Fitting, gouged
AFT ENTRY DOOR CUTOUT FWD FRAME UPPER NR 1 PRSSURE PAD FITTING GOUGED. ACFT GROUNDED. REMOVED DOOR LINING IAW AMM 25-21-25, R & R FITTING IAW DWG 147AS101,…
- 16 Mar 2015
Sign, detached
RED & WHITE BACKLIGHT EXIT SIGN BY R1 DOOR FELL OFF. ACFT GROUNDED. REPLACED R1 EXIT LIGHT ASSY. OPS NORMAL.
- 12 Mar 2015
Lens, missing
R1 GALLEY DOOR EXIT LIGHT COVER IS OFF. ACFT GROUNDED. REPLACED R1 GALLEY DOOR EXIT LIGHT COVER REF AMM 33-51-00. OPS TEST NORMAL.
- 18 Feb 2015
Skin, cracked
LT HORIZONTAL LOWER SKIN HAS 2 CRACKS AT STA. 138.7, APPROXIMATELY 9' AND 17' FROM THE AFT SPAR. ACFT GROUNDED. REMOVED DAMAGE FABRICATED DOUBLER AND 3 EA…
- 5 Feb 2015
Battery Pack, failed
DURING EMERGNECY LIGHT TEST, TWO BATTERIES FAILED 15 MINUTE CHECK. ACFT GROUNDED. R & R THE BATTERY PACKS AND REPEATED TEST. TEST PASSED.
- 11 Aug 2014
Guide, out of adjust
L1 DOOR WILL NOT LATCH SHUT FROM THE INSIDE. ACFT GROUNDED. FOUND L1 DOOR GUIDE ARM OUT OF ADJUSTMENT. ADJUSTED GUIDE ARM, OPS CHECKED GOOD IAW MM…
- 18 Feb 2012
Slide, failed
WHILE ACCOMPLISHING L1 DOOR SLIDE OPERATIONAL CHECK, L1 DOOR SLIDE FAILED TO INFLATE AUTOMATICALLY. SLIDE DEPLOYED NORMALLY WITH MANUAL HANDLE. REMOVED AND…