N521JB
2001 Airbus Industrie A320-232 standard FAA →
registration
- 2001
service difficulty reports
94 reports
- 5 Sep 2026
Attach Angle, cracked
DURING HEAVY MAINTEANCE,FUSELAGE. CENTER FUSELAGE FR35 FWD FACE TO PRESSURE BULKHEAD ATTACHMENT AT LEVEL OF STGR 30LH, FASTENER HOLES, CRACK DAMAGE – TIME…
- 5 Sep 2026
Stringer, cracked
DURING HEAVY MAINTEANCE, REAR FUSELAGE, TAILCONE STGR 5LH AT LEVEL OF FR74, CRACK DAMAGE. PERMANENT REPAIR (CONSIDERED A MAJOR REPAIR)
- 5 Sep 2026
Floorbeam, cracked
DURING HEAVY MAINTEANCE,FRONT SPAR STRINGERS & HORIZONTAL FLOORBEAMS FR36 CRACKED. PERMANENT REPAIR (CONSIDERED A MAJOR REPAIR)
- 5 Sep 2026
Power Supply, no test
DURING HEAVY MAINTEANCE,EPSU 10WL DOES NOT PASS EMERGENCY LIGHT TEST; REF AEROMAN NR 2026-346269 W/O:2026 280/1: REMOVED AND REPLACED EPSU 10WL IAW AMM…
- 5 Sep 2026
Frame, cracked
DURING HEAVY MAINTEANCE,DURING HEAVY MAINTEANCE,CRACK INDICATION ON FRAME (1 EA) (CRACK INDICATION FOUND ON OPENHOLE LOC FR39LH STR14 PLUS 4 INCH. CRACK…
- 5 Sep 2026
Door Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME (1 EA) (CRACK INDICATION FOUND O N OPEN HOLE LOC FR39LH STR14 PLUS 3 INCH. CRACK DIRECTION 9 OCLOCK AND…
- 5 Sep 2026
Door Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME (1 EA) (CRACK INDICATION FOUND O N OPEN HOLE LOC FR41LH STR14 PLUS 4. CRACK DIRECTION 3 OCLOCK AND DEPT H…
- 5 Sep 2026
Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME (1 EA) (CRACK INDICATION FOUND O N OPEN HOLE LOC FR41LH STR14 PLUS 3 INCH. CRACK DIRECTION 6 OCLOCK AND…
- 5 Sep 2026
Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME (1 EA) (CRACK INDICATION FOUND O N OPEN HOLE LOC FR39RH STR14 PLUS 4 INCH. CRACK DIRECTION 6 OCLOCK AND…
- 5 Sep 2026
Door, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON OPEN HOLE LOC FR38RH STR19. CRACK DIRECTION 6 OCLOCK AND DEPTH =0.100 INCH PAX CABIN; (RESOLVED ON W/O:…
- 5 Sep 2026
Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME 35 AT STGR30LH LEVEL OPEN FASTENER HOLE FWD MIDDLE COMMON TO SKIN,CRACK DIRECTION IS 12OCLOCK, CRACK DEPTH…
- 5 Sep 2026
Stringer, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON STR 5 LH FR 74 PLUS 1 INCH .CRACK DIRECTION PARALEL TO RADIUS OF STRINGER.CRACK LENGTH 0.250INCH; (RESOLVED…
- 5 Sep 2026
Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME 35 AT STGR30LH LEVEL OPEN FASTENER HOLE LOWE R OUTBOARD COMMON TO MILLED COUPLING, CRACK DIRECTION IS 3…
- 5 Sep 2026
Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME 35 AT STGR30LH LEVEL OPEN FASTENER HOLE AFT LOWER COMMON TO SKIN, CRACK DIRECTION IS 6 OCLOCK, CRACK DEPTH…
- 5 Sep 2026
Frame, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION ON FRAME 35 AT STGR30LH LEVEL OPEN FASTENER HOLE MIDD LE LOWER COMMON TO SKIN, CRACK DIRECTION IS 6 OCLOCK, CRACK…
- 5 Sep 2026
Floorbeam, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ5 FRAME 36. CRACK L= 0.450…
- 5 Sep 2026
Floorbeam, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ4 FRAME 36. CRACK L= 0.316…
- 5 Sep 2026
Floorbeam, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ3 FRAME 36. CRACK L= 0.405…
- 5 Sep 2026
Floorbeam, cracked
DURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ2 FRAME 36. CRACK L= 0.320…
- 5 Sep 2026
Floorbeam, not reported
DURING HEAVY MAINTEANCE, (CPCP) "REF AEROMAN N/R 2026-432642, REMOVED AND REPLACED FLOOR BEAM (Y1292) LOC.BTW FR 12 TO FR 24 AT AFT GALLEY AREA I.A.W A320 SRM…
- 5 Sep 2026
Floor Support, not reported
DURING HEAVY MAINTEANCE, (CPCP) "REF AEROMAN N/R 2026-432640, REMOVED AND REPLACED FLOOR BEAM (Y765) LOC. BTW FR12 TO FR 24 AT FWD GALLEY AREA I.A.W SRM…
- 5 Sep 2026
Floor Support, cracked
DURING HEAVY MAINTEANCE, (CPCP) "REF AEROMAN N/R 2026-432684,REMOVED AND REPLACED FLOOR BEAM Y765 LOC.FR66 TO FR70 AT AFT GALLEY AREA I.A.W A320 SRM 51-72-11…
- 5 Sep 2026
Floorbeam, not reported
DURING HEAVY MAINTEANCE, (CPCP) "REFERENCE AEROMA W.O.2026 266/1 NR 2026-432734. REMOVED AND REPLACED FLOOR BEAM -Y464.8 AT AFT GALLEY AREA IAW SRM 51-72-11,…
- 5 Sep 2026
Floor Support, not reported
DURING HEAVY MAINTEANCE, (CPCP) REFERENCE AEROMAN WO 2026 266/1 NR 2026 432685 _ REMOVED AND REPLACED FLOOR BEAM -Y765 AT AFT GALLEY AREA I.A.W A320 SRM…
- 5 Sep 2026
Fitting, not reported
DURING HEAVY MAINTEANCE, (CPCP) REFERENCE AEROMAN WO 2026-266/1 NR 2026 432782_ REMOVED AND REPLACED CENTER FITTING LOC. BTW FR 66 THRU FR 68 AT LEVEL OF STR…
- 5 Sep 2026
Shear Plate, not reported
DURING HEAVY MAINTEANCE, (CPCP) "REFERENCE AEROMAN W.O 202 266/1 NR 2026-432646 * REMOVED AND REPLACED SHEAR PLATE LOC. BTW FR69 TO FR7O AT LEVEL STR 23R AFT…
- 19 Feb 2026
Terminal, detached
FLT #1014 CUN-MCO. "RED EMERGENCY EXT LIGHT AT SEAT 9C INOPERATIVE. FOUND TERMINAL END DISCONNECTED FROM THE SOCKET, RECONNECTED THE TERMINAL END AND…
- 27 Jun 2025
Socket, loose
FLT#2584, MCO-JFK. "FWD BULK HEAD LH SIDE RED EMERGENCY LIGHT INOP REPORTED BY CA; ACCOMPLISHED TEMP REPAIR OF EMERGENCY LIGHT SOCKET, INSTALLED HEAT…
- 27 Feb 2025
Door Frame, cracked
DURING HEAVY MAINTENANCE: MAIN CABIN L2 DOOR FRAME FR68 AT STOP FITTING #1 #3 HOLE HAS A CRACK; (RESOLVED ON W/O: 1355989 TASKCARD: NR-00006) REF GSO-HAECO…
- 27 Feb 2025
Rib, corroded
DURING HEAVY MAINTENANCE: LEFT WING T/E STRUCTURAL RIB IS CORRODED ON THE UPPER ATTACH FLANGE BETWEEN APPROX RIB 20 AND 21 ON THE AFT SIDE OF THE AFT SPAR;…
- 26 Sep 2024
Valve, failed
FLT#1230, CUN-EWR. (AIRCRAFT DECLARED AN EMERGENCY INTO EWR) 'HYD G LO LVL CAUTION LIGHT ON- NO GREEN PRESSURE OR QTY; FOUND GREEN HYD PRIORITY VALVE LEAKING…
- 16 Oct 2022
None, none
FLT#204, BDA-BOS. (AIRCRAFT DECLARED AN EMERGENCY AND PERFORMED AN AIR TURN ABCK TO BDA) 'ANOMALOUS FUEL DECREASE FROM LEFT MAIN TANK AFTER T.O. RTB TXKF, NO…
- 25 Aug 2022
Battery, inoperative
DURING HEAVY MAINTENACE: FAULT EPSU EMERGENCY POWER SUPPLY UNIT BATTERY 10WL, 11WL,12WL, 13WL IN PASSENGER CABIN (4EA); REF: ARM W/O 2022 175/1 NR 2022-420207…
- 25 Aug 2022
Window Post, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE ATTACHMENT AREA CONTINUITY FITTING RH SIDE, CRACK LENGTH IS 0.200…
- 29 Oct 2021
Unknown, odor
FLT 401, BOS-MSY. DIRTY SOCK ODOR ON DESCENT FIRST AT 17000 FEW MINUTES STRONGER MODERATE AT ABOUT 10000 ALL THE WAY TO LANDING TWO F/A'S ALSO SMELLED IT IN…
- 11 Sep 2021
Apu, odor
FLT 909, BOS-NAS. DURING DECENT STRONG ODOR IN CABIN ( APU SYSTEM ); PERFORMED ECS DECONTAMINATION OF PACKS IAW AMM 21-00-00-615-803 AND 36-11-00-615-805-A03.…
- 1 May 2020
Skin Panel, damaged
DURING HEAVY MAINTENANCE, ELONGATED HOLES ON WING SKIN PANEL FUEL TANK RIB17 ON RH WING; REF: ARM W/O 2020 81/1 N/R 2020-117580. PERMANENT REPAIR INAW A320…
- 1 May 2020
Frame, cracked
DURING HEAVY MAINTENANCE, CRACK ON FRAME 68RH UPPER CORNER WEB JOINT; REF W/O 2020 81/1 N/R 2020-117556. SDR FOR MAJOR REPAIR. PERMANENT REPARED IAW AEROMON…
- 19 Aug 2019
Slide, no test
FT # 225, EMERGENCY SLIDES L1 AND R1 FAILED EMERGENCY LIGHT TEST (ESCAPE SLIDE LIGHTING); REMOVE AND REPLACED R1 SLIDE IAW AMM 25-62-44. PERFORMED OPS CHECK…
- 29 Mar 2019
Lens, missing
FT # 678, EMER EXIT LIGHT COVER MISSING COVER AND HANGING; R & R EMERGENCY LIGHT COVER PER MM 33-50-00 OPS CHK OK.
- 8 Nov 2018
Housing, defective
FT 422, NAS-JFK. AFT GALLEY EXIT SIGN OVERHEAD SHORTING OUT. REPEAT INOP FROM PREVIOUS FLIGHT WHEN BANGING ON IS TEMPORARILY FIXED. R&R AFT GALLEY OVERHEAD…
- 16 Oct 2018
Epsu, failed
FT 2074, TPA-EWR. FWD EMERGENCY LIGHTS INOP. R&R CONNECTOR AT 10WL IAW ESPM 20-44-19, OPS CHECK FAIL. FOUND 5409VB SHORTED, REMOVED HARNESS, R&R EPSU IAW AMM…
- 16 Oct 2018
Wire, shorted
FLT 2074, TPA-EWR. FWD EMERGENCY EXIT LIGHTS INOP; FOUND WIRE SHORTED OUT FIN 5409VB, HARNESS REF. IAW AWM 33-51-01, R&R IAW ESPM 20-33-00, OPS TEST…
- 16 Oct 2018
Epsu, failed
FLT 2074, TPA-EWR. AFT EPSU FAULT (13WL); REMOVED AND REPLACED RELAY 8WL AND DIODE 1158VD. ALSO REPLACED AFT EPSU (13WL) AND EPSU BATTERY AS REQUIRED. AFT…
- 16 Oct 2018
Battery, failed
FLT 2074, TPA-EWR. AFT EPSU FAULT (13WL); REMOVED AND REPLACED RELAY 8WL AND DIODE 1158VD. ALSO REPLACED AFT EPSU (13WL) AND EPSU BATTERY AS REQUIRED. AFT…
- 16 Oct 2018
Light, inoperative
FLT 2074, TPA-EWR. 41WL EXIT MARKING SIGN AND 100 WL 1 BLOWN DURING TROUBLESHOOTING; FIN : 41 WL ( EXIT MARKING SIGN) + FIN 100 WL (LIGHT) RELAMPED PER AMM…
- 16 Oct 2018
Battery, discharged
FLT 2074, TPA-EWR. EMERGENCY LIGHT BATTERY BY FWD L1 DOOR OVERHEAD GALLEY AREA INOP. FIN 10 WL; R & R EMERGENCY LIGHT BATTERY PER AMM 31-51-38, OPS CHECK GOOD.
- 26 Sep 2018
Charger, failed
FLT 1558, BOG-FLL. FOUND FWD GALLEY EMERG EXIT LIGHT AS WELL AS ROW 1 AND 3 LIGHTS OUT; FOUND GALLEY BATTERY CHARGER, FWD LT SIDE, BAD. REPLACED BATTERY…
- 26 Sep 2018
Battery Pack, discharged
FLT 1558, BOG-FLL. FOUND MULTIPLE EMERGENCY LIGHTS FWD GALLEY INOP; REPLACED BATTERY PACK ON CHARGER IN FWD LT OVERHEAD PER AMM 33-51-00.
- 14 Sep 2018
Slide, faulted
FLT 894, STI-EWR. DURING EMERGENCY LIGHTS TEST, FWD LT SLIDE FAULTED. REMOVED AND REPLACED FWD LT SLIDE PACK IAW AMM 25-62-44. OPS CHECK GOOD.
- 29 Jun 2018
Stiffener, cracked
DURING HEAVY MAINTENANCE, A CRACK WAS FOUND ON LATERAL WINDOW FRAME STIFFENER RT SIDE. REFER TO EC A18-507-01. FUSELAGE/ NOSE FWD FUSELAGE/ RT SIDE/ LATERAL…
- 29 Jun 2018
Pressure Panel, cracked
DURING HEAVY MAINTENANCE, SEVERAL CRACKS WERE FOUND AT SUBJECT LOCATION. REFER TO EC A18-517-01. FUSELAGE / CENTER FUSELAGE / CENTER WING BOX / FR 35-36 / LT…
- 25 Oct 2017
Smoke Detector, false activation
SMOKE DETECTOR FOR LIVE TV WENT OFF. TURNED OFF RACK POWER. NO SMOKE VISIBLE OR ODOR. RESET THE SYSTEM IAW AMM 23-39-00. OPS CHECKED NORMAL.
- 15 Sep 2017
Unknown, odor
AFTER DESCENT WITH POWER AT IDLE, ON LEVEL OFF WITH POWER UP, DIRTY ODOR IN COCKPIT. ODOR STRONG AT FLIGHT POWER UP, BUT DISAPPEARS FAIRLY QUICKLY WITH…
- 2 Aug 2017
Filter, odor
DIVERTED DUE TO A FAINT ODOR, WHILE ISOLATING THE SOURCE, PERFORMED BORESCOPE INSPECTION ON THE NR 1 ENGINE IAW TSM 05-50-00-810-813-A. FOUND NO ACTIVE OIL…
- 2 Aug 2017
Filter, odor
DIVERTED DUE TO A FAINT ODOR OBSERVED, WHILE ISOLATING THE SOURCE PERFORMED BORESCOPE INSPECTION ON THE NR 1 ENGINE IAW TSM 05-50-00-810-813-A. FOUND NO…
- 6 Aug 2016
Seat Track, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT SEAT TRACK FRAMES 64 -69. REMOVED AND REPLACED SEAT TRACK.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT FRAMES 64 -69. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Seat Track, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT SEAT TRACK FRAMES 64 -69 CORRODED. REMOVED AND REPLACED THE SEAT TRACK.
- 6 Aug 2016
Shear Plate, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT RT SHEAR PLATE FRAMES 69 -70. REMOVED AND REPLACED THE SHEAR PLATE.
- 6 Aug 2016
Shear Plate, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON THE AFT SHEAR PLATE FRAMES 69-70. REMOVED AND REPLACED THE SHEAR PLATE.
- 6 Aug 2016
Seat Track, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FWD SEAT TRACK BETWEEN FRAMES 12 AND 16, Y503, REMOVED AND REPLACED SEAT TRACK.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT AT Y512 FRAMES 64 - 70. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT AT Y919 FRAMES 65 - 67. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT AT Y252 FRAMES 64 - 67. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT FRAMES 69-70. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT AT Y765 FRAMES 66 - 70. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT FRAMES 64-69. REMOVED AND REPLACED FLOOR SUPPORT.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT FLOOR SUPPORT FRAMES 66-68. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Floor Support, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT FRAMES 64 -67, Y1162. REMOVED AND REPLACED THE FLOOR SUPPORT.
- 6 Aug 2016
Doubler, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON LT OB FLAP TRACK DOUBLER. REMOVED AND REPLACED DOUBLER.
- 6 Aug 2016
Door Sill, corroded
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON AFT LT DOOR SILL. REMOVED AND REPLACED THE DOOR SILL.
- 22 Jan 2015
Power Supply, failed
ON MAINTENANCE CHECK, FOUND RT INTERIOR AND EXTERIOR EMERGENCY LIGHTS SHOWING FAULTS ON THE POWER SUPPLY. R & R EPSU IAW 33-51-38. OPS CHECK GOOD.
- 8 Jun 2014
Battery Pack, failed
DURING MAINTENANCE, NOTED A FAILURE OF BATTERY IAW EPSU 13WL. R & R BATTERY PACK IAW AMM 33-51-38.
- 15 Mar 2014
Wire, broken
CREW REPORTED THAT ROW 11 SEAT EMERGENCY EXIT LIGHT WAS INOPERATIVE. INSPECTED AND FOUND BROKEN WIRE AT ROW 11. REPAIRED WIRE, EMERGENCY LIGHTS OPS CHECK GOOD…
- 2 Mar 2014
Light, missing
ON GROUND, WHILE PERFORMING THE CLEANING OF THE ACFT. IT WAS DISCOVERED THAT THE EMERGENCY SIDEWALL LIGHT ASSY AT 10A WAS MISSING AND THE WIRES HANGING DOWN.…
- 1 Jul 2013
Skin, corroded
DURING HEAVY MX VISIT, LT WING T/E TOP SKIN ON RIB 74 OTBD OF NR 1 SPOILER ACTUATOR FITTING CORRODED. REMOVED ALL CORROSION BY BLENDING. ACCOMPLISHED DETAIL…
- 15 May 2013
Fuel, contaminated
FLT 823 JFK-SDQ, AIR RETURN TO JFK DUE TO FOB AMBER X'S AND LEFT WING (INNER AND OUTER) AMBER X'S NO FUEL INDICATION. DEFUELED AND REFUELED FOUND WATER ON…
- 8 Jun 2012
Fan, failed
FLT 820 SDQ-JFK, CREW DECLARED EMERGENCY DUE PASSING 14,000FT ON DESCENT SMELLED IN COCKPIT ONLY INITIALLY THE AROMA SIMILAR TO SULFUR OF A LIT MATCH. SMELL…
- 30 May 2012
Thermostat, failed
FLT 136 RSW-JFK, AIR BLEED NR 1 FAULT, NR 1 WAS RECOVERED AS PER THE DUAL BLEED FAULT. QRH LOST AT FL350, RESET AT 15000FT. CREW DECIDED TO COMPLETE ONE HOUR…
- 19 May 2012
Wire Harness, shorted
FLT 21 JFK-TPA, ON GROUND MAINTENANCE CHECK FOUND SEVERAL IN SEAT EMERGENCY LIGHTS INOP. FOUND SEAT HARNESS 5751VC AT ROW 15 WITH CROSS SHORT. REPLACED…
- 19 May 2012
Battery, failed
FLT 21 JFK-TPA, ON GROUND MAINTENANCE CHECK FOUND 10WL FWD BATTERY LEFT FAILED. REMOVED AND REPLACED 10WL BATTERY AS PER AMM 33-51-38. SYSTEM OPS CHECK NORMAL.
- 19 May 2012
Power Supply, faulty
FLT 21 JFK-TPA, ON MAINTENANCE CHECK, 11WL EPSU SHOWS UNIT FAULT DURING EMERGENCY POWER SUPPLY TEST. REPLACED EPSU 11WL PER AMM 33-51-38, OPS CHECK GOOD.
- 7 Nov 2011
Door, missing
FLT 527 EWR-MCO, AIRCRAFT DIVERTED TO JFK DUE TO MODERATE VIBRATION DURING CLIMB APPROX 25,000 FT. A DULL BANG ON AIRFRAME WAS HEARD AND A VIBRATION BEGAN…
- 22 May 2011
Electrical Box, failed
FLT 744 SJU-MCO, LTV 8 ABC ELECT SMELL. PERFORMED TSM TASK 23-39-00-810. PERFORMED ELECTRICAL ODOR OPS CHECK IAW AMM 23-39-00, SECTION 5000. REPLACED XEB AT 8…
- 6 Jan 2011
Sensor, failed
FLT 711 JFK-LAS, L/G GEAR NOT DOWNLOCKED ON FINAL AT GEAR DOWN CALL. T/S TO RT MAIN GEAR DOOR SENSOR 34GA. REMOVED AND REPLACED SENSOR AND OPS TEST NORMAL.
- 3 Mar 2009
Video Display, defective
F/O TV SCREEN HAD 1 INCH WHITE BAND ACROSS MIDDLE OF SCREEN ON ALL CHANNELS 40 MINUTES INTO FLIGHT SMELLED ACRID ODOR FROM BACK OF SCREEN AREA. TURNED CAMERA…
- 28 Sep 2007
Warning Message, illuminated
DURING CRUISE AT 370 AT .77 MACH AIRCRAFT ABRUPTLY PITCH DOWN THEN RETURNED TO LEVEL FLIGHT. FOLLOWED BY F/CTRL ELAC 2 PITCH FAULT. COMPLETED ECAM, NO FURTHER…
- 30 Dec 2006
Unknown, odor
PILOT COMPLAINED ABOUT BURNING SMELL FOR FEW SECONDS AFTER FWC 2 FAULT. PERFORMED TASK 24-00-00-810-823 IAW TSM. NO BURNING SMELL NOTICED.
- 25 Jan 2005
Wire, broken
R1 DOOR SIDEWALL EMERGENCY EXIT LIGHT ASSEMBLY INOP. REPAIRED BROKEN WIRE TO LIGHT ASSEMBLY. OP CHECK GOOD PER ESPM 20-53-00.
- 7 Nov 2003
Wire Harness, shorted
TAKEOFF ABORTED DUE TO NR 1 ENG OVERHEAT ECAM, ABOUT 90 KT. PERFORMED TSM TASK 77-00-00-810-817. EIS(DMC1) REPORT SHOWED NR ENG 1 OVERTEMP. CHECKED REPORTS 4,…
- 3 Aug 2002
Harness, overheated
Flt#94, OAK to JFK, Multiple faults occurred in flight including RA1, Nose wheel steering, #1 PFD, ND, #1 TLS, GPS, Blue electrical Hyd, #1 RMP, MCDU.Found…
- 2 Aug 2002
service difficulty reports
Flt 95, JFK to OAK, At cruise, Multiple spurious failures during flight: Capt PFO flickering, main PNL & PFD/main PNL lights flickering GPWS. (unassociated…
- 4 Dec 2001
Skin, damaged
FLT 74, JFK TO PBI, AT PBI, ON A WALKAROUND THE FUSELAGE SKIN WAS FOUND DAMAGED AT FRAME 24, BETWEEN STRINGER 21 AND 22. THE DAMAGE CONSISTED OF A TEAR APPROX…