N517JB
2000 Airbus Industrie A320-232 standard FAA →
registration
- 2000
service difficulty reports
98 reports
- 10 Dec 2025
Unknown, odor
FLT 1371, LGA-FLL. TRANSIENT ODOR OFENGINE EXHAUST IN AFT GALLEY FROM TAKEOFF TO 10,000 FT. ODOR DISSAPATED AFTER THAT. NR 3 FA NOTED ODOR BUT NOT NOTED BY…
- 3 Aug 2025
Fmu, failed
FLT#2077, MCO-PUJ. (AN EMERGENCY WAS DECLARED AND AC PERFORMED AN AIR RETURN TO MCO) "AFTER VR #1 ENGINE FAILURE. GENTLE ROLLBACK NO NOISES; PERFORMED…
- 7 Apr 2025
Oil System, leaking
FLT#1704, MDE-SJU. 'DESCENDING AND PASSING THRU 9000' FLIGHT ATTENDANT REPORT AN MUSTY ODOR IN THE CABIN ; CW SECTION B2 INFORMATION NOTICES 2017-T015 AND TSM…
- 24 Mar 2025
Unknown, odor
FLT#251, HPN-RSW. 'INFLIGHT ADVISES CABIN ODOR DURING DESCENT. ODOR IMPROVED UPON DEPLANNING; PERFORMED PACK BURN IAW AMM 21-00-00 PACK OPERATES NORMAL NO…
- 23 Mar 2025
Apu, odor
FLT#583, JFK-MCO.' ON DESCENT BELOW 10000 FEET NOTICED STRONG DIRTY SOCK SMELL ON SHORT FINAL FA'S CALLED TO COMPLAIN OF A POSSIBLE FUME EVENT IN PROGRESS.…
- 21 Mar 2025
Pump, malfunctioned
FLT#595, HPN-MCO. (AIRCRAFT DIVERTED TO JFK) 'UPON CLIMBOUT FROM HPN ND GEAR RETRACTION, WE RECEIVED THE ECAM L/G DOORS NOT CLOSED. WE COMPLIED WITH THE ECAM…
- 23 Dec 2024
Door Frame, cracked
DURING HEAVY MAINTENANCE, FR 68 LH / DOOR STOP FITTING #1 HOLE LWR INBD CRACKED /1/ SB A320-53-1288 REV 02 /2/ A320 SRM 53-41-12-300-008 /3/ DOSSIER REFERENCE…
- 23 Dec 2024
Stringer, corroded
DURING HEAVY MAINTENANCE: WINGS / LH WING / BOTTOM STRINGER 3 / BOTTOM FLANGE UPPER SURFACE BETWEEN RIB 5 - 6 / CORROSION - TIME LIMITED REPAIR; REFERENCES:…
- 23 Dec 2024
Stringer, cracked
DURING HEAVY MAINTENANCE: FUSELAGE/ REAR FUSELAGE/ FR68 STGR 8R AFT FLANGE RADIUS AND HOLES/ CRACKS- PERMANENT REPAIR; REFERENCE /1/ AEROMAN EA 53-9049-24…
- 23 Dec 2024
Stringer, corroded
DURING HEAVY MAINTENANCE: CORROSION ON STRINGER OF DRY BAY LEADING EDGE AREA LOCATED BTW RIB 5 AND RIB 6 ON LH WING; REF AEROMAN WO 2024 266/1 NR 2024-444297;…
- 23 Dec 2024
Power Supply, faulted
DURING HEAVY MAINTENANCE: FAULT EPSU AT ROW 11 LH PASSENGER CABIN FIN 11WL AND FAULT EPSU AT ROW 11 RH PASSENGER CABIN FIN 12WL; REF AEWROMAN NR 2024-444555…
- 23 Dec 2024
Stringer, corroded
DURING HEAVY MAINTENANCE: CORROSION ON STRINGER OF DRY BAY LEADING EDGE AREA LOCATED BTW RIB 5 AND RIB 6 ON RH WING; WORK ACCOMPLISHED BY AEROMAN W/O 2024…
- 23 Dec 2024
Rib, corroded
DURING HEAVY MAINTENANCE: CORROSION ELEVATOR OUTBOARD RIB ON RH HORIZONTAL STABILIZER (1 EA) (CPCP FINDING); (RESOLVED ON W/O: 1316756 TASKCARD: NR-00035) REF…
- 23 Dec 2024
Frame, cracked
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 68 RH SIDE AT LOWER I/B FASTENER HOLE AT DOOR STOP FITTING#1, CRACK DIRECTION IS 6 OCLOCK, LAYER AFFECTED…
- 17 Aug 2024
Epsu, failed
FLT#2468, CHS-BOS. 'L1 AND R1 EMERGENCY EXIT SIGNS NOT LIGHTING UP; R+R EMERGENCY POWER SUPPLY UNIT (10WL) PER AMM 33-51-38. OPS CHK NORMAL.'
- 20 Jul 2024
Wire Harness, faulted
FLT#451, BOS-MCO. 'EMERGENCY LTS AT ROWS 1ABC, 10 ABC /DEF, 11ABC NOT ILLUMINATED; AT ROWS 1ABC AND 10 ABC REPLACED EMERGENCY LIGHT HARNESS AS PER ESPM…
- 19 May 2024
Seal, leaking
FLT#2672, TPA-EWR. 'LEVEL 2 CABIN ODOR EVENT DURING CRUISE/ DESCENT DID NOT RESOLVE ON EITHER PACK AFTER FOLLOWING ISOLATION GUIDE. ODORS OBSERVED BY ALL…
- 15 Apr 2024
Proximity Sensor, faulted
FLT#371, LGA-FLL. '2L DOOR NOT ARMING ON COCKPIT DOOR PAGE; REMOVED AND REPLACED PROX SWITCH -HANDLE L AFT ESC SLIDE (7WN1) IAW AMM 52-73-11. OPS CHECK OK. NO…
- 3 Mar 2024
Unknown, odor
FLT#471, LGA-FLL. 'INFLIGHT REPORTED A LEVEL 3 FUME EVENT UPON ARRIVAL, STATING IT BEGAN AT TOP OF DESCENT UNTIL BLOCKIN; COMPLIED WITH INFORMATION NOTICE…
- 24 Feb 2024
Sensor, failed
FLT#8644, JFK-JFK. (AIRCRAFT DECLARED AN EMERGENCY) 'A TEST FLIGHT WAS REQ'D FOR REPEAT NWS FAULTS IN FLIGHT THE TEST FLIGHT WAS UNSUCCESSFUL DUE TO THE…
- 24 Feb 2024
Sensor, failed
FLT#8644, JFK-JFK. (AIRCRAFT DECLARED AN EMERGENCY) 'A TEST FLIGHT WAS REQ'D FOR REPEAT NWS FAULTS IN FLIGHT THE TEST FLIGHT WAS UNSUCCESSFUL DUE TO THE…
- 24 Feb 2024
Sensor, failed
FLT#8644, JFK-JFK. (AIRCRAFT DECLARED AN EMERGENCY) 'A TEST FLIGHT WAS REQ'D FOR REPEAT NWS FAULTS IN FLIGHT THE TEST FLIGHT WAS UNSUCCESSFUL DUE TO THE…
- 18 Feb 2024
Control Unit, failed
FLT#2330, RSW-JFK. (AIRCRAFT DECLARED AN EMERGENCY INTO JFK) 'ABOUT 50 MINS BEFORE LANDING IN JFK RECEIVED AN ECAM WHEEL/NOSEWHEEL STEERRING FAULT. WE TRIED 3…
- 2 Sep 2023
Computer, failed
FLT#211, FLL-AUS. (AIRCRAFT DECLARED AN EMERGENCY AND PERFORMED AN AIR TURN BACK TO FLL) 'UPON ROTATION AND CLIMBOUT A/C REQUIRED FWD PRESS ON STICK. ONCE…
- 17 Dec 2022
Bulb, burned out
FLT#129, JFK-RSW. 'EMERGENCY EXIT LIGHTS BULBS ARE BURNT OUT. (SEVERAL); RELAMPED EMERGENCY EXIT LIGHT BULBS IAW AMM 33-51-13. THE OPS CHECK IS GOOD. A/C OK…
- 27 Nov 2022
Indicator, malfunctioned
FLT 673, BOS - AUA. AIRCRAFT AIR TURN BACK. FUEL AUTO FEED FAULT UNABLE TO COMPLY WITH QRH WITH UNREADABLE WING TANK QUANTITY. FUEL QUANTITY FAULT RH WING XXX…
- 1 Jun 2022
Skin Panel, corroded
DURING HEAVY MAINTENACE, WINGS / LH WING / TOP SKIN PANEL 2 / TRAILING EDGE OVERHANG / LOWER SURFACE / RIB 7A / CORROSION AT PREVIOUS REPAIRED AREA –…
- 1 Jun 2022
Frame, damaged
DURING HEAVY MAINTENACE, FUSELAGE/ NOSE FWD FUSELAGE/ FWD WINDSHIELD / CENTER POST AND CONTINUITY FITTINGS / CRACK DAMAGE - PERMANENT REPAIR (FRAME AND…
- 1 Jun 2022
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION TRAILING EDGE LOCATED TOP SKIN, LOWER SURFACE, OVERHANG AREA AT LEVEL RIB 8 ON LH WING (CPCP RELATED REFER TO MPDTASK…
- 1 Jun 2022
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION FLOORBEAM AND Y765 LOC BTW FR 41 AND FR47 IN PASSENGER CABIN; REF AEROMAN WO# 2022-5/1, NR 2022-1555841. REMOVED AND…
- 1 Jun 2022
Fitting, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION WAS FOUND IN CONTINUITY FITTING LH SIDE LOCATED ON FRAME 2 ON COCKPIT, CRACK LENGTH IS 0.110 INCHES APPROX; REF…
- 1 Jun 2022
Window Post, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION WAS FOUND IN WINDSHIELD FRAMING LOWER CENTER POST RH SIDE LOCATED ON FRAME 2 ON COCKPIT CRACK LENGTH IS .100 INCHES…
- 1 Jun 2022
Window Post, cracked
DURING HEAVY MAINTENANCE, CRACK INDICATION WAS FOUND IN WINDSHIELD FRAMING LOWER CENTER POST LH SIDE LOCATED ON FRAME 2 ON COCKPIT, CRACK LENGTH IS 0.095…
- 1 Jun 2022
Epsu, failed
DURING HEAVY MAINTENANCE, EPSU 12WL FAILED OPS TEST; REF AEROMAN NR 2022-156039 WO 2022 5/1 REMOVED AND REPLACED EPSU 12WL IAW AMM 33-51-38-000-001-A AND AMM…
- 1 Jun 2022
Light, inoperative
DURING HEAVY MAINTENANCE, EMERGENCY LIGHT ON SEAT 1 LH INOP; REF AERMAN WO 2022 5/1, NR 2022-155578; REMOVED AND REPLACED EMERGENCY LIGHT ON SEAT 1 LH IAW AMM…
- 14 Apr 2021
Battery, failed insp
FLT# 6101, FLL-MZJ. EPSU BATTERIS 10WL FAILED EMERGENCY LIGHT TEST ; EPSU BATTERIS 10WL FAILED EMERGENCY LIGHT TEST.
- 14 Apr 2021
Battery, failed insp
FLT# 6101, FLL-MZJ.EPSU BATTERY FAILED EMERGENCY LIGHT TEST ; R/R EMERGENCY LIGHT BATTERY IAW AMM 33-51-38 OPS GOOD.
- 26 Aug 2020
Servo Control, failed
FLT 119, ALB-MCO. ON DESCENT AT APPX. 16' K NOTICED VIBRATION. FA IN AFT CALLED AND ADVISE DRASTIC VIB IN REAR OF A/C. GALLEY AND FLOOR VIB; REF. T/S FOUND RH…
- 17 Jun 2020
Sign, inoperative
FLT 1505, EWR-FLL. EMERGENCY EXIT SIGN INOP AT L2 DOOR (45WL). REPLACED EXIT SIGN PER AMM 33-51-16, OPS CKS GOOD.
- 16 Mar 2020
Battery, failed
SUPPLEMENTAL INFORMATION (UNIQUE CONTROL NUMBER): FLT# 905, EWR-TPA. RH EMER EXIT EPSU FAILED BITE TEST; REPLACED EPSU BATTERY PER AMM 33-51-38.
- 15 Mar 2020
Attach Fitting, worn
DURING HEAVY MAINTENANCE, FUSELAGE / KEEL BEAM / FWD LUG BORE MLG DOOR ACTUATOR FITTING / WEAR MARK - PERMANENT REPAIR ; REF/3/ RDAS PROVIDES APPROVAL OF THIS…
- 3 Jul 2019
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON MAIN CABIN FLOORBEAM Y1292 FRAME 68 STR 23L; REF NR 440578-26156 REMOVED CORROSION ON FLOORBEAM Y1292 AT…
- 3 Jul 2019
Floorbeam, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON MAIN CABIN FLOORBEAM Y1292 FRAM 67 + 16" STR 23L; REF NR 440578-26157. REMOVED CORROSION ON FLOORBEAM…
- 14 May 2019
Slide, partial deploy
FLT 6160, SXM-SJU. L1 DOOR SLIDE PARTIALLY DEPLOYED WITH DISARM POSITION AND PIN INSTALLED; ACCOMPLISHED CONTROLLED SLIDE DEPLOYMENT PER GMM 8-2. REMOVED L1…
- 30 Oct 2017
Battery Pack, inoperative
DURING HEAVY MAINTENANCE, EMERGENCY LIGHT BATTERY 10WL FAILS TEST FOR BATTERY. REMOVED AND REPLACED BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-38-000-001A.
- 20 Aug 2017
Oil Cooler, failed
DIRTY SOCK ODOR THROUGHOUT AIRCRAFT, DETECTED BY ALL FLIGHT CREW MEMBERS. ODOR ISOLATED TO APU. PEFORMED DECONTAMINATION OF THE (ECS) IAW AMM…
- 20 Aug 2017
Fan, failed
DIRTY SOCK ODOR THROUGHOUT AIRCRAFT. ODOR ISOLATED TO APU. PEFORMED DECONTAMINATION OF THE (ECS) IAW AMM 21-00-00-615-004-A. R & R DEOILER CASING SEAL ASSY AT…
- 30 Dec 2016
Bypass Valve, failed
FLT 778, LAS-BOS, AIR RETURN BACK TO LAS. FLIGHT CREW RECEIVED THE FOLLOWING MESSAGE ON ECAM, HYD G ENG 1 PUMP LO PR AND HYD G SYS LO PR. CREW ELECTED TO…
- 7 Nov 2016
Power Supply, failed
FT 1973, EMERGENCY LIGHT FAILED TEST. R & R FWD POWER SUPPLY UNIT 10WL. OPS CHECK WAS PERFORMED. OPS CHECK PASSED IAW AMM 33-51-38.
- 23 Oct 2016
Servo, failed
FLT 278, PILOT REPORTED NOSE WHEEL STEERING FAULT IN FLIGHT. THE ACFT PULLED TO THE LEFT ON TAKEOFF AND STEERING ON THE GROUND FELT STIFFER THAN NORMAL…
- 1 Aug 2016
Engine, failed
EMERGENCY DECLARED, AIR RETURN TO DEPARTURE. CREW PERFORMED A RETURN TO FIELD AFTER ENGINE 2 EXPERIENCED POSSIBLE COMPRESSOR STALL. REPORTED SEVERAL AUDIBLE…
- 14 May 2016
Relay, failed
EMERGENCY DECLARED. LANDING GEAR WOULD NOT EXTEND. PERFORMED L/G GRAVITY EXTENSION. WHEN LOWERING GEAR, GOT LANDING GEAR CONTROL ON LANDING GEAR DISPLAY;…
- 15 Apr 2016
Floor Support, corroded
CABIN FLOOR SUPPORT Y-503.4 HAS CORROSION AT FRAME 16. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM…
- 15 Apr 2016
Floorbeam, corroded
RIGHT CABIN FLOORBEAM Y-254 AND Y- 81 HAS CORROSION AT FRAME 12. R & R CABIN FLOORBEAM IAW SRM 51-7 & 51-42-11.
- 15 Apr 2016
Floorbeam, corroded
AFT CABIN FLOORBEAM -464 RT CORRODED AT FRAME 66. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-14-283-002. R & R THE FLOORBEAM IAW SRM 53-72-11, PG…
- 15 Apr 2016
Floorbeam, corroded
CABIN FLOORBEAM 254 HAS CORROSION AT FRAME 20. R & R THE FLOORBEAM IAW SRM 51-42-11.
- 15 Apr 2016
Floorbeam, corroded
AFT CABIN FLOORBEAM +Y919L CORRODED AT FRAME 66. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-14-283-002. R & R THE FLOORBEAM IAW SRM 51-42-11, PG…
- 15 Apr 2016
Floorbeam, corroded
LEFT CABIN FLOORBEAM 1292 HAS CORROSION AT FRAME 20. R & R THE FLOORBEAM IAW SRM 51-42-11.
- 15 Apr 2016
Support, corroded
AFT CABIN SUPPORT CORRODED 6 INCHES FWD OF FRAME 70 AND 16 INCHES AFT FRAME 69. R & R.
- 15 Apr 2016
Shear Web, corroded
AFT CABIN SHEAR WEB CORRODED FROM FRAME 69-70. R & R SHEAR WEB IAW SRM 51-42-11.
- 15 Apr 2016
Floor Support, corroded
CABIN FLOOR SUPPORT +254 HAS SPOTS OF CORROSION BETWEEN FRAMES 16-20; R & R THE FLOOR SUPPORT.
- 15 Apr 2016
Shear Web, corroded
AFT CABIN SHEAR WEB FRAMES 69-70 CORRODED. R & R SHEAR WEB IAW SRM 51-42-11.
- 15 Apr 2016
Support, corroded
AFT CABIN SHEAR WEB SUPPORT CORRODED 6 INCHES FWD OF FRAME 70. R & R SHEAR WEB SUPPORT IAW SRM 51-42-11.
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOOR SUPPORT CORRODED AT FRAME 66. R & R THE FLOOR SUPPORT FROM FRAME 64 TO 66 IAW SRM 51-42-11.
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOOR SUPPORT CORRODED AT FRAMES 67 - 68. R & R THE FLOOR SUPPORT IAW SRM 51-42-11.
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOOR SUPPORT -765R CORRODED FROM FRAMES 66-68. R & R THE FLOOR SUPPORT IAW SRM 51-42-11.
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOOR SUPPORT 765R CORRODED AT FRAME 66. R & R FLOOR SUPPOPRT BETWEEN FRAMS 64-66 IAW SRM 51-42-11.
- 15 Apr 2016
Floorbeam, corroded
AFT CABIN FLOORBEAM +Y1292L CORRODED AT FRAME 68. R & R THE FLOORBEAM IAW SRM 51-42-11.
- 15 Apr 2016
Floorbeam, corroded
AFT CABIN FLOORBEAM +Y1292 AT STR 23L CORRODED 2" AFT FRAME 66; R & R AFT CABIN FLOOR BEAM +Y1292 AT STR 23L 2" AFT OF FRAME 66 IAW SRM 51-42-11.
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOORBEAM +Y1292L SPLICE AT STR 23L CORRODED AT NUT PLATE HOLES FROM FRAME 66-68; R & R AFT CABIN FLOORBEAM +Y1292 AT STR 23L FROM FRAME 66-68 IAW…
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOORBEAM -Y1292 CENTER TRIPLE BEAM CORRODED AT SPLICE STR 23R 9" FWD FRAME 68; R & R AFT CABIN FLOORBEAM -1292, STR 23R IAW SRM 51-42-11.
- 15 Apr 2016
Floor Support, corroded
CORROSION FOUND ON AFT CABIN FLOORBEAM -1292, FRAME 66, 18" AFT FRAME 67 AND 2" FWD OF FRAME 68 SPLICE; R & R AFT CABIN FLOORBEAM -1292, STR 23R IAW SRM…
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOORBEAM 1292R TRIPLE BEAM CORRODED AT SPLICE STR 23R 9" AFT FRAME 68, R & R AFT CABIN FLOORBEAM FRAME 68 -1292 AT STR 23R AS REQUIRED IAW SRM…
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOORBEAM -1292 , STR 23R AFT TRIPLE BEAM CORRODED NUT PLATE HOLES FROM FRAMES 68-69; R & R AFT CABIN FLOORBEAM FRAMES 68-69, -1292, STR 23R AS…
- 15 Apr 2016
Floor Support, corroded
AFT CABIN FLOORBEAM +Y464L AT STR 23R CORRODED AT FRAME 66 F/A SEAT MOUNTS; R & R AFT CABIN FLOORBEAM +Y464L AT STR 23R, FRAME 66 F/A SEAT MOUNTS IAW SRM…
- 9 Jul 2015
Switch, malfunctioned
RETURNED TO DEPARTURE, VHF 1 AND 2 EMMITING. R & R F/O PTT SWITCH IAW AMM 27-92-41, OPS CHECK GOOD.
- 7 Jan 2015
Bushing, worn
DIVERTED, ACFT EXPERIENCE VIBRATION CLIMBING 15,000 FT- 25,000 FT, NO ENGINE ISSUES OR OTHER SYS ISSUES. VIBRATION RETURNED ON FINAL APPROACH DURING…
- 5 Oct 2014
Skin, corroded
DURING HEAVY MAINTENANCE CHECK, LT WING TOP SKIN FOUND CORRODED AT RIB 7. REPAIRED IAW E/C A14-604-01.
- 5 Oct 2014
Skin, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION OF THE RT WING TOP SKIN AT RIB 7A. REPAIRED THE WING SKIN IAW E/C A14-605-01.
- 4 Oct 2014
Frame, cracked
DURING HEAVY MAINTENANCE, FUSELAGE FRAME SPLICE 47 HAS AN 18 INCH CRACK INDICATION AT STRINGER 5R-7R REAMED HOLES UP TO DIAMETER, PERFORMED ROTO TEST…
- 6 Nov 2013
Wire Harness, damaged
DURING MAINTENANCE CHECK, FOUND ROW 1 ACFT LT EMERGENCY PATH LIGHT INOPERATIVE. R & R EMERGENCY PATH HARNESS AT ROW 1 ACFT LT AMM 33-51-00.
- 2 Feb 2013
Rod, lack of lube
FLT 6411 MCO-TPA, ON HEAVY MAINTENANCE CHECK FOUND R1 DOOR GOES FROM DISARMED TO ARMED WITH DOOR OPEN. ADJUSTED ESCAPE SLIDE CONTROL IAW AMM 52-11-00. LUBED…
- 19 Feb 2012
Control Panel, failed
FLT 772, FLIGHT CREW REPORTED THAT CABIN EMERGENCY EXIT LIGHTS REMAINED ON WITH EMERGENCY EXIT SWITCH IN THE OFF POSITION. REMOVED AND REPLACED FORWARD…
- 11 Nov 2010
Unknown, odor
FLT 702 SJU-JFK, BURNING SMELL ROW 15, NO VISIBLE SMOKE, TURNED OFF LTV SYSTEM SMELL DISSIPATED. COMPLIED WITH TSM 23-39-00-810-801 "ELECTRICAL ODORS OR FUMES…
- 20 Feb 2009
Actuator, failed
FLT JB705 - JFK-SJU - AIR TURNBACK TO JFK, ENG 1 COMPRESSOR VANE ECAM, FAULT CYCLING EVERY COUPLE OF MINUTES, PER TSM 75-30-00-810-852. FOUND TO BE VSV…
- 28 Dec 2008
Structure, corroded
ON WEEKLY INSP, AFT CARGO DOOR PROFILE SEAL BETWEEN FR 52 TO FR 56 HAS CORROSION AT WITH THE 5 FOLLOWING SIZE OF DEFECT LENGTH AND DEPTH. PERMANENT REPAIR…
- 18 Dec 2008
Outflow Valve, failed
FLT NR 1729, JFK-SDQ, RETURNED TO JFK, PRESSURIZATION-V/S VARIABLE FROM -1250 TO +1250 FPM IN SYS 1 & SYS 2 AS WELL AS MANUAL-OUTFLOW VALVE FLUCTUATED IN…
- 26 Jul 2007
Hydraulic System, overserviced
FLT 24, TPA TO JFK, AIR RETURN TO TPA. HYD YELLOW RESERVOIR OVERHEAT ECAM ON CLIMBOUT. PERFORMED TSM TASK 29-13-00-810-802. FOUND YELLOW RESERVOIR…
- 26 Jul 2007
Check Valve, failed
FLT 1012, JFK TO BOS, DECLARED EMERGENCY, YELLOW RSVR OVERHEAT INDICATION BOTH ON ECAM & OVERHEAD ON ENG & ELECTRIC PUMPS. T/S TSM 29-13-00-810-802. FOUND…
- 23 Aug 2006
Fan, inoperative
VENT EXTRACT FAULT. CREW REPORTED BURNING ODOR INBOUND TO PBI. REMOVED AND REPLACED EXTRACT FAN (18HQ) AND OPS CHECKED NORMAL IAW 21-26-51.
- 29 Aug 2005
Access Panel, loose
ON CLIMBOUT THRU FL220 FELT SIGNIFICANT VIBRATION IN FRONT PART OF AIRCRAFT IN BOTH PILOTS SEATS AND RUDDER PEDALS, REDUCED POWER AND LEVELED OFF AND STILL…
- 29 Aug 2005
Control Servo, out of rig
CLIMBING THROUGH FL180 FELT VIBRATION IN FLIGHT CONTROLS, RUDDERS AND PILOTS SEAT. AFT F/A'S REPORTED NOTICEABLE VIBRATION IN AFT PART OF AIRCRAFT. VIBRATION…
- 6 Jul 2005
Odor, detected
F/A NOTICED ODOR OF BURNT WIRES STARTING AT ROW 12ABC AND STRONGEST AT ROW 14ABC. LIVE TV AND CABIN FANS TURNED OFF AND PUT AC FLOW TO HIGH AND ODOR…
- 27 Nov 2003
Contactor, malfunctioned
AT START OF TAKEOFF ROLL GOT ECAM, MADE A LOW SPEED, ABORT AT APPROX 80 KNOTS & RETURNED TO GATE. REMOVED AND REPLACED THE DC SHED ESSENTIAL BUSS CONTACTOR…
- 15 Jun 2003
Power Supply, failed
WHILE ACCOMPLISHING WEEKLY CHECK, EMERGENCY LIGHT FAILED TEST; T/S TO EPSU AT RIGHT EMERGENCY EXIT. REPLACED EPSU AT RIGHT EMERGENCY EXIT WITH BORROWED PART…
- 5 Aug 2002
Hydraulic System, lack of lube
AT JFK FLT 17, JFK TO FLL, ON TAKEOFF, B-HYDRAULIC SYSTEM LOW ECAM MESSAGE. ABORTED TAKEOFF AT APPROX 75 KTS, RETURNED TO GATE. FOUND BLUE SYSTEM LOW, FOUND…
- 9 Jul 2001
Power Supply, faulty
ON DAILY MAINTENANCE CHECK EPSU FWD LEFT FAULT. REMOVED AND REPLACED EPSU UNIT IAW AMM 33-51-38. OPS CHECK GOOD.
- 7 Jun 2001
Windshield, cracked
BEFORE DESCENT FLT 43, JFK TO MCO, AT 39,000 FT, FLIGHT CREW REPORTED CRACKED CAPTAIN'S FRONT WINDSHIELD. REMOVED AND REPLACED CAPT WINDSHIELD PER AMM…