N515NK
2006 Airbus A319-132 standard FAA →
reservations
earlier registrations
1 past record
- 2006
NTSB
- 6 Sep 2019
accident, Fort Myers FL
service difficulty reports
64 reports
- 8 Jan 2023
Unknown, odor
CLIMBING THROUGH 10,000, AFT FA REPORTS ROTTEN EGG SMELL COMING FROM CABIN VENTS. DISSIPATED AFTER 10 SECONDS.-CABIN ODOR (BAD SMELL) CHECKED PER A320 TSM…
- 9 Oct 2022
None, none
ODOR IN COCKPIT AND MID CABIN DURING CRUISE,MELTING WAX OR WIRE SMELL, SEEMES TO DISAPATE WITH PACK 2 OFF, AIR STORT IN SKRG CART HAD VERY HEAVY BLACK EXHAUST…
- 20 Sep 2022
None, none
FA REPORTS FUMES SMELL OF DIRTY SOCKS LATE DESEND / APPROACH IN TO MIA-PERFORMED TROUBLESHOOTING PER TSM 05-50-00-810-831--A, R&R RECIR FILTER CARTRIIDGES IAW…
- 27 Feb 2022
None, none
F/A'S REPORTED ELECTRICAL BURNING SMELL A FEW MINUTES BEFORE LANDING UNTIL AFTER TOUCHDOWN FROM MID CABIN FORWARD. STARTED AROUND ROW 7. ( APU SYSTEM…
- 12 Dec 2021
Megaphone, failed
FWD GALLEY MEGAPHONE WONT TURN OFF. -R/R FWD GALLEY MEGAPHONE IAW AMM 25-65-51. OPS CHECK GOOD.
- 30 Jul 2021
Megaphone, inoperative
FWD MEGAPHONE INOP-R&R PER EMERGENCY EQUIPMENT DRAWING NK319-132-EQ.
- 29 Jul 2021
Megaphone, inoperative
FA REPORTS FORWARD MEGAPHONE INOP-REMOVED AND REPLACED MEGAPHONE OPS CHECKS GOOD. OK FOR SVC
- 2 Jul 2021
Pin, installed
DURING INSPECTION FOUND RH OFF WING SLIDE INFLATION RESERVOIR VALVE WITH SAFETY PIN INSTALLED. SDR REQUIRED-REMOVED SAFETY PIN FROM RH OFF WING ESCAPE SLIDE…
- 27 Mar 2020
Accumulator, low pressure
R2 DOOR ASSIST ACCUMULATOR LOW -SERVICED R2 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00.
- 10 Jan 2020
Unknown, odor
FUME / ODOR ON FINAL APPROACH MUSTY / MILDEW SMELL. PACK 1 & ENG BLEED 1 OFF AND SMELL DISSIPATES WITHIN 20 SEC. ODOR IN COCKPIT ONLY-PERFORMED TSM…
- 5 Dec 2019
Unknown, odor
FUME EVENT RIGHT AFTER T/O ISOLATED PACK 1 AND IT APPEARED TO FIX THE PROBLEM ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP…
- 18 Nov 2019
Megaphone, no test
FA FWD MEGAPHONE WOULD NOT TEST DURING PREFLIGHT -REMOVED AND REPLACED FWD MEGAPHONE IAW SPIRIT DRAWING NK 319-932-EQ A/C OK TO CONTINUE
- 11 Oct 2019
Bottle, low pressure
R2 DOOR NEEDS SERVICE -SERVICE R2 DOOR BOTTLE ASSYST IAW 52-10-00
- 5 Oct 2019
Controller, malfunctioned
AIR RETURN DUE TO THE PILOT SUSPECTING THE NR 4 SPOILER ACTUATOR WAS FLUTERING. IAW TSM 27-60-00-810-846-A FAULT WAS COMFIRMATION. R & R THE NR 2 SEC IAW AMM…
- 18 Aug 2019
Unknown, odor
FUME EVENT AFT CABIN --
- 24 May 2019
Unknown, fumes
FUME EVENT DURING DESCENT THROUGH 11000 FEET TURNED PACK 1 OFF AND SMELL WENT AWAY-OPERATED PACK 1 AND 2 FOR 30 MINS COULD NOT REPLICATE. AS PRECAUTIONARY…
- 4 May 2019
Drain Valve, leaking
HYD ENG 2 PUMP LO PR IN FLIGHT. PERFORMED INSPECTION OF YELLOW SYS HYD SYS FOUND YELLOW ACCUMULATOR AND YELLOW RESERVOIR DRAIN VLV LEAKING REMOVED AND…
- 19 Apr 2019
Structure, corroded
CORR FOUND @ RIB10-12 STR 11LH RAF01 2351058-01 OPENED LTPR NRI 5000874916-0010-REVIEWED LTPR NRI 5000874916-0010 AND HAS BEEN ACCOMPLISHED
- 19 Apr 2019
Structure, corroded
COO FOUND RIB17-189 STR 10 RH WING SKIN PNL RAF012351059-02 OPENED LTPR NRI 5000874878-0010-REVIEWED LTPR NRI 5000874878-0010 AND HAS BEEN ACCOMPLISHED.…
- 19 Mar 2019
Bottle, low pressure
DURING WEEKLY CHECK FOUND R2 DOOR BOTTLE ASSISTANCE LOW-SERVICE DOOR R2 BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00.
- 8 Mar 2019
Megaphone, broken
FWD FA MEGAPHONE BROKEN. R&R FWD POSITION MEGAPHONE IAW AMM 25-65-1.
- 2 Mar 2019
Flashlight, inoperative
FWD GALLEY LEFT HAND & RIGHT HAND FA TAN FLASHLIGHTS INOP. R&R FWD GALLEY LEFTHAND & RIGHTHAND FA TAN FLASHLIGHTS IAW CMM 25-60-02. OPS CHECK GOOD.
- 2 Mar 2019
Flashlight, inoperative
AFT GALLEY LEFTHAND FA TAN FLASHLIGHT INOP. R&R AFT GALLEY LEFT HAND FA TAN FLASHLIGHT IAW CMM 25-60-02. OPS CHECK GOOD.
- 3 Feb 2019
A/C Pack, odor
FUME CHEMICAL SMELL ON DESCENT OUT OF 10K - PACK 1 OFF - SMELL GONE - PACK 1 ON - SMELL BACK - PACK 1 OFF - SMELL GONE. ( PACKS A319 WITH MOD 31283/MP P7125…
- 23 Jan 2019
Unknown, odor
FUME EVENT ON DESCENT SUSPECT PACK 1-PERFORMED TSM 05-50-00-810-831-A RAN APU BLEED AND PACKS. PERFORMED ENGINE RUN IAW 71-00-00. NO ORDER NOTED IN COCKPIT OR…
- 11 Jan 2019
Unknown, fumes
POSSIBLE FUME EVENT ON FINAL APPROACH ( PACKS WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 370 )--
- 12 Nov 2018
Megaphone, no test
AFT GALLEY MEGAPHONE WILL NOT TEST-R/R AFT GALLEY MEGAPHONE IAW SPIRIT AIRLINES EMERGENCY EQUIPMENT DRAWING LAYOUT NKA319-132EQ
- 11 Nov 2018
Battery, discharged
DUE TO LOW BATTERY FWD AND AFDTG MEGAPHONE-R/R AFT AND FWD MEGAPHONE I/A/W 25-65-51 OPS CHECK OK
- 7 Jun 2018
Ecs, contaminated
OILY ODOR IN THE MAIN CABIN AND FLIGHT DECK, WITH APU BLEED AIR SUPPLYING BOTH PACKS. PERFORMED A DECONTAMINATION OF THE EVIRONMENTAL CONTROL SYSTEM WITH APU…
- 1 Jun 2018
Megaphone, malfunctioned
FWD MEGAPHONE DOES NOT LIGHT UP GREEN LIGHT WHEN IN USE. R & R THE MEGAPHONE.
- 14 Apr 2018
Unknown, odor
DIRTY SOCK ODOR IN MID CABIN. RAN COM. CREW DID NOT SMELL ANY ODORS. ACCOMPLISHED ENGINE RUNS IAW AMM 71-00-00 WITH BOTH PACKS ON, NO DEFECTS, ODOR NOTED.…
- 28 Dec 2017
Seal, leaking
NR 1 PACK CONTAMINATED, FUMES IN COCKPIT DURING DECENT THRU 10000 FT. THE PACK WAS TURNED OFF. PERFORMED DECONTAMINATIONOF THE ECS IAW AMM 21-00-00. R & R…
- 9 Dec 2017
Flashlight, inoperative
FA AFT FLASHLIGHT INOP. R/R'D AFT F/A FLASHLIGHT IAW SPIRIT AIRLINES EMERGENCY EQUIP. DRAWING NK319-132-EQ. THIS CLEARS DMI # 230108401 MOC NOTIFIED PLACARD…
- 6 Dec 2017
Ecs, contaminated
FUME EVENT ON DESCENT FROM ABOUT 14,000' TO 9,000' DURATION ~5 MIN. DIRTY SOCK SMELL. ALL CREWMEMBERS SMELLED IT. PERFORMED DECONTAMINATION OF THE ECS IAW AMM…
- 30 Nov 2017
Carbon Seal, deteriorated
FUME EVENT ON RESENT INTO FLL FAS CALLED AT THE LEVEL OFF AT 6000 FT MSL CONTINUED TO FLL TURNED PACK 1 OFF NO CHANGE TURNED PACK 1 ON, THEM PACK 2 OFF NO…
- 28 Sep 2017
Acm, odor
WHEN DESCENDING THROUGH 3,000 FT, FA CALLED AND REPORTED A STRONG DIRTY SOCK ODOR IN CABIN. TURNED OFF THE NR 2 PACK AND FA REPORTED THAT THE ODOR DISIPATED…
- 20 Jun 2017
Unknown, odor
BURNING ODOR NOTED IN AFT CABIN. PERFORMED TSM 05-50-00, RAN THE NR 1 AND 2 ENGINES, AND APU WITH PACKS. NO ODORS DETECTED. ACFT OK FOR SERVICE.
- 16 Apr 2017
Oxygen Mask, inoperative
FIRST OFFICER`S OXYGEN MASK HEAD HARNESS WILL NOT INFLATE. REMOVED AND REPLACED THE OXYGEN MASK IAW AMM 35-12-41,PB 401. OPS CHECKED GOOD, NO DEFECTS NOTED AT…
- 20 Sep 2016
Oxygen Mask, unwanted deploy
FA OXYGEN MASK DEPLOYED FWD GALLEY. REPACKED OXYGEN MASKS IAW AMM 35-21-43-550-801-A OPS CHECKED GOOD
- 18 Sep 2015
A/C Pack, faulted
SMOKE IN COCKPIT AND CABIN, FOLLOWED BY ECAM, AIRPACK 1 REG FAULT. ACCOMPLISHED TSM 05-50-00-810-831-A, FOUND NR 1 PACK CAUSE OF SMOKE. PERFORMED OPS CHECK OF…
- 22 Jun 2015
Oxygen Mask, inoperative
O2 MASK INOPERATIVE. R & R PRIMARY OBSERVER MASK, 5757HM IAW AMM 35-12-41. OPS CK GOOD.
- 26 Jun 2014
Oxygen Mask, leaking
FO'S OXYGEN MASK HAS A LOOSE SEAL. R & R F/O'S OXYGEN MASK IAW AMM 35-12-41, PB 401. OPS CHECKED GOOD.
- 10 May 2014
Oxygen Mask, inoperative
PRIMARY OBSERVER'S OXYGEN MASK INOPERATIVE. R & R OXYGEN MASK IAW AMM 35-12-41-000-002-A/ 400-002-A. OPS CHECKED GOOD IAW AMM 35-12-41-710-001.
- 28 Feb 2014
Battery Pack, no test
EMERGENCY BATTERY AT 12WL FAIL CAPACITY TEST. R & R EMERGENCY BATTERY 12WL IAW AMM.
- 3 Dec 2013
Oxygen Mask, inoperative
OXYGEN MASK AT OBSERVERS SEAT INOPERATIVE. R & R OXYGEN MASK IAW AMM. OPS CHECKED GOOD.
- 13 Nov 2013
Oxygen Mask, unwanted deploy
OXYGEN MASKS DEPLOYED AT ROW 16 ACFT LT. STOWED O2 MASKS AT SEAT ROW 16ABC IAW AMM. PERFORMED OPS CHECK OF MANUAL RELEASE OF OXYGEN MASKS IAW AMM. OPS CHECKED…
- 8 Nov 2013
Oxygen Mask, dislodged
OXYGEN MASKS IN AFT GALLEY FELL. STOWED MASKS IAW AMM. PERFORMED MANUAL MASK RELEASE IAW AMM. DROP TESTED GOOD AT THIS TIME.
- 7 Nov 2013
Oxygen Mask, dislodged
AFT GALLEY OXYGEN MASK FELL DURING LANDING. PERFORMED OPS CHECK OF MANUAL RELEASE. OPS CHECKED GOOD.
- 29 Oct 2013
Oxygen Mask, unwanted deploy
AFT F/A OXYGEN MASK DROPPED. REPACKED MASK ASSY IAW AMM. PERFORMED OPS CHECK OF MANUAL MASK RELEASE IAW AMM. OPS CHECKED OK.
- 17 May 2013
Seal, leaking
SQUEALING NOISE FROM OVERWING EXIT LT IAW TSM 52-11-00-810-826-A. INSPECTED SEALS ON LEFT OVERWING EXIT HATCH IAW ACFT MM. NO ISSUES FOUND WITH FRAME OR HATCH…
- 7 Apr 2013
Fitting, corroded
LT WING AFT SPAR RETRACTION FITTING EVIDENCE OF CORROSION. REPAIRED AND REWORKED CORROSION ON RETRACTION FITTING IAW DWG RI R572-48389 AND EA5720-1306.
- 7 Apr 2013
Bulb, burned out
RT OVERWING PANEL AFT EMERGENCY LIGHT LAMP OUT. REPLACED LAMP IAW AMM 33-51-15-400-001A. OPS CHECKED GOOD IAW 33-51-15-710-053A.
- 7 Apr 2013
Connector, disconnected
RT OFFWING SLIDE EMERGENCY LIGHTING CONNECTOR PLUG FOUND DISCONNECTED. RECONNECTED RT OFFWING SLIDE CONNECTOR PLUG IAW AMM 25-62-42-400-001A. OPS CK GOOD IAW…
- 7 Apr 2013
Battery Pack, failed
EPSU BATTERY PACK FAILED TEST. R & R BATTERY IAW AMM 33-51-38-000-002A AND 35-51-38-400-002A. OPS CHECKED GOOD IAW AMM 33-51-00-710-001A.
- 7 Apr 2013
Cotter Pin, missing
RT ELEVATOR SUPPORT ARM INBD SERVO AFT ATTACH BOLT MISSING COTTER KEY. INSTALLED COTTER KEY ON RT ELEVATOR SUPPORT ARM AFT ATTACH BOLT IAW AMM…
- 7 Apr 2013
Cotter Pin, missing
RT ELEVATOR SUPPORT BRACKET INBD SERVO MISSING COTTER KEYS. REPLACED COTTER KEYS ON RT ELEVATOR SUPPORT BRACKET IAW AMM 55-16-42-400-001 & 20-21-11-900-001A.
- 7 Apr 2013
Reservoir, low pressure
RT OVERWING ESCAPE SLIDE BOTTLE HAS LOW PRESSURE. R & R ESCAPE SLIDE RESERVIOR IAW AMM 25-62-46-00-001A & 25-62-46-400-001A. OPS CHECK GOOD IAW AMM…
- 7 Apr 2013
Lanyard, misinstalled
L2 DOOR SLIDE MOORING LINE AND ELECTRICAL WIRING INCORRECTY INSTALLED. CORRECTED L2 DOOR SLIDE MORING AND ELECTIRCAL WIRING.
- 7 Apr 2013
Knob, missing
FWD MEGAPHONE MISSING KNOB. REPLACED KNOB IAW MM.
- 7 Apr 2013
Knob, missing
AFT MEGAPHONE MISSING VOLUME KNOB. REPLACED KNOB IAW MM.
- 7 Apr 2013
Lens, cracked
R1 EMERGENCY DOOR LOWER LENS CRACKED. R & R LENS COVER IAW MM.
- 7 Apr 2013
Fuel Tank, fod
FOUND 6 INCH DIAMETER, APPROXIMATELY 2 FEET IN LENGTH OF PVC CONDUIT WEDGED IN LT WING FUEL TANK AFT SURGE DOOR. REMOVED PVC PIPE AND INSPECTED IAW MM.
- 7 Apr 2013
Fuel Tank, fod
FOUND 6" DIAMETER, APPROX 2 FT LENGTH OF PVC CONDUIT WEDGED IN RT WING FUEL TANK AFT SURGE DOOR. REMOVED PVC PIPE AND INSPECTED IAW MM.
- 11 Apr 2008
Apu, fire
VISIBLE FLAMES FROM APU. SHUT DOWN APU/DISCHARGED FIRE BOTTLE. INSPECTED APU INTAKE, EXHAUST, AND COMPARTMENT NO PHYSICAL DAMAGE NOTED. APU DEACTIVATED AND…