~/tools/licenses/N515GJ
N515GJ
2003 Bombardier INC CL-600-2C10 standard FAA →
registration
- 2003
service difficulty reports
4 reports
- 25 Oct 2026
Warning System, intermittent
SERVICE DOOR CAUTION INTERMITTENT DURING TAXI. PERFORMED OPS CHECK OF SERVICE DOOR WARNING SYSTEM IAW AMM 52-70-00. OPS CHECKED GOOD.
- 6 Oct 2026
Pitot Head, failed
LEFT PITOT HEAT CAUTION MSG. R & R ADSHC IAW CDS AMM 30-31-15, R & R LT PITOT-STATIC HEAD IAW CDS 34-11-01, PERFORMED OPS TEST OF THE ADSHC IAW CDS AMM…
- 4 Oct 2026
Elec Connector, damaged
LEFT PITOT HEAT CAUTION MESSAGE AFTER T/O. REMOVED AND REPLACED LH PITOT PROBE HEATER CONNECTOR IAW ESPM 20-33-00 OPS CHECK GOOD SEALANT NEEDS VERIFIED CURED.
- 23 Aug 2026
Pseu, inoperative
PROXIMITY SYS 1 FAULT (B1 047818)PSEU / LA & LB IOC 6 BUSS DEGRADED. REMOVED AND REPLACED PSEU IAW CRJ 550 AMM 32-61-00 OPS CHECK GOOD.