N514NK
2006 Airbus A319-132 standard FAA →
earlier registrations
1 past record
- 2006
service difficulty reports
98 reports
- 1 Sep 2023
Unknown, unknown
POSSIBLE FUME EVEN IN DESCENT, MOSTLY BELOW 10K STGRONG ODOR ESPECIALLY IN CABIN UNABLE TO ISOLATE. ( PACKS A319 WITH MOD. 30626/MP K6443 (ENHANCED ECS)…
- 28 Jul 2023
Controller, faulted
"CAB PR SYS 2 FAULT, PLANE WOULD NOT DEPRESSURIZE AFTER LANDING ^P REMAINED @ 2.5 PSI. CAPTAIN HAD TO OPEN COCKPIT WINDOW-R/R CPC 2 (12HL) IAW AMM 21-31-34…
- 6 Oct 2022
Flashlight, inoperative
R2 EMERGENCY FLASHLIGHT INOP.-REPLACED EMERGENCY FLASHLIGHT IAW SPIRIT AIRLINES EMERGENCY EQUIPMENT.
- 21 Sep 2022
Megaphone, damaged
FWD MEGAPHONE VOLUME KNOB MISSING-REMOVED AND REPLACED FWD MEGAPHONE IAW DRAWING A319 EMER EQUIP. OPS CHECK GOOD
- 30 May 2022
None, none
PUNGENS DIRTY SOCK SMELL ON AIRCRAFT SAFETY CONCERN-ACCOMPLISHED TSM 05-50-00-810-836 PERFORMED DECONTAMINATION OF THE ENVIRONMENTAL CONTROL SYST IAW AMM…
- 29 May 2022
None, none
DIRTY SOCK SMELL IN AFT CABIN AFTER DECENDING THROUGH FL180-ACCOMPLISHED TSM 05-50-00-810-831 FOR CABIN ODOR. RAN BOTH PACK ON APU BLEED. ISOLATED PACKS, NO…
- 29 May 2022
None, none
DIRTY SOCK ODOR IN AFT CABIN-PERFORMED TSM 05-50-00-810-831-A INSPECTION OF THE A/C WAS PERFORMED AND ENGINES WERE INSPECTED NO EVIDENCE OF LEAKS. ENGINE…
- 14 Nov 2021
None, none
L2 DOOR ASSIST BOTTLE NEEDS SERVICE. -SERVICED L2 DOOR ASSIST BOTTLE I.A.W AMM 52-10-00.
- 2 Oct 2021
A/C Pack, odor
BURNING OIL/ RUBBER SMELL ODOR IN AFT GALLEY.-T/S A/C IAW TSM 05-50-00-810-831-A. ISOLATED SMELL/ODER TO PACK 2. PERFORMED DECONTAMINATION OF ECS IAW AMM…
- 24 Sep 2021
None, none
DURING INITIAL CLIMB - VERY LARGE SINGLE BIRD STRIKE TO AN UNKNOWN AREA OF THE AIRCRAFT. RETURNED SAP FOR INSPECTION CORRETION - JL - LEFT WINGLET.-PERFORMED…
- 8 Jun 2021
Flashlight, inoperative
AFT FACING FA JUMPSEAT FLASHLIGHT INOP-REMOVED AND REPLACED AFT FACING FA JUMPSEAT FLASHLIGHT IAW SPIRIT AIRLINES EMERGENCY EQUIPMEMT DRAWING NK319-132-EQ
- 13 Dec 2019
Bottle, low pressure
L1 DOOR ASSIST BOTTLE REQ. SVC.-SERVICE DOOR IAW AMM 52-10-00
- 20 Sep 2019
Bottle, low pressure
L1 DOOR ASSIST BOTTLE REQUIRES SVC. SVC L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001-A TO REQUIRED LIMITS.
- 21 Apr 2019
Outflow Valve, warning message
VENT SKIN VALVE FAULT AFTER ROTATION. PERFORM AVEC TEST PER AMM 21-+26-00. TESTED OK, ACFT OK FOR SERVICE. MSG CLEARED.
- 21 Mar 2019
A/C Pack, odor
ODOR FROM PACK 1 ON DESCENT-PER TSM 05-50-00-810-831-A CONFIRMED PACK 1 SOURCE OF ODOR SEE L/P 2535157-02 FOR CORRECTIVE ACTION.
- 30 Dec 2018
Control Rod, damaged
IN FLIGHT L/G DOORS NOT CLOSED ECAM MESSAGE-REPLACED NLG DOOR CONTROL RODS PER AMM 32-31-41.PERFORMED OPS TEST PER 32-22-00 OPS CHECK NORMAL FAULT CLEARED.
- 13 Sep 2018
Screw, stripped
R&R MEGAPHONE BATTERYS. SCREW STRIP ON FWD MEGAPHONE COULD NOT REMOVE BATT. R&R FWD MEGAPHONE IAW EMERGENCY EQUIPMENT DRAWING LAYOUT EQ REV 6.
- 30 May 2018
Clamp, loose
ODOR DURING DESCENT, PERFORMED A VISUAL INSPECTION OF THE NR 1 ENGINE, NO LEAKKS NOTED. ENG. OIL CONSUMPTIION OK. PERFORMED GVI OF THE A/C PACKS, FOUND PIPE…
- 29 May 2018
Unknown, odor
DURING DESCENT, HAD AN ODOR IN THE CABIN. PERFORMED TSM 05-50-00-810-831-A. PERFORMED A WALKAROUND, NO DISCREPANCIES NOTED. COMPLETED APU, NR 1 & 2 PACKS OPS…
- 20 Dec 2017
Window Frame, cracked
RIGHT WINDSHIELD FRAME D53111061211 AT FRAMES 3 - 4 CRACKED, COMPLIED WITH THE WINDHSIELD SIDE POST LOWER ATTACHMENT LOWER STIFFENER.
- 20 Dec 2017
Window Frame, cracked
LEFT WINDSHIELD FRAME CRACKED. REPAIRED IAW EO 5311-1786, REV 00.
- 20 Dec 2017
Skin, gouged
SKIN FRAMES 34 - 35, STRINGER 43L & R GOUGED. REMOVED THE GOUGES IAW 80392172 AND EO 5311-1791.
- 20 Dec 2017
Torsion Box, cracked
TORSION BOX AT FRAME 43, STR 15R CRACKED. REPAIRED IAW 80932748, AND EO 5331-1792.
- 20 Dec 2017
Door Sill, corroded
FWD RT DOOR SILL CORRODED. REPAIRED THE DOOR SILL IAW 803942001, AND EO 5311-1790.
- 20 Dec 2017
Profile, damaged
AFT CARGO CEILING PROFILE DAMAGED. REPAIRED IAW 80395404/003, CLASSIFIED AS MINOR.
- 20 Dec 2017
Skin, debonded
NR 2 ENGINE INBD FAN COWL OUTER SKIN & INNER SKIN DAMAGE SHOWS DEBONDING. COMPLIED WITH EO 5414-1719.
- 24 Oct 2017
Unknown, odor
STRONG DIRTY SOCK SMELL ON DESCENT AROUND 6,000 FEET TURNED OFF PACK 1 SMELL EVENTUALLY WENT AWAY.
- 9 May 2017
Megaphone, malfunctioned
MEGAPHONE ALARM SOUND UNLESS HELD IN THE OFF POSITION. REMOVED AND REPLACED THE FLIGHT ATTNDANT MEGAPHONE FWD, IAW DWG NK319-132-EQ, OPS CHECKED GOOD.
- 5 Dec 2016
Oxygen Mask, unsecure
OXYGEN MASK OVER ROW 11 FELT OUT OF OVERHEAD. OPS CHECK MANUAL MASK RELEASED IAW AMM 35-23-00.
- 2 Dec 2016
Door, defective
F/A AFT GALLEY O2 MASK DROPPED FROM CEILING. R&R AFT GALLEY F/A O2 MASK CONTAINER DOOR IAW B/E CMM 35-21-74. OPS TEST OK IAW AMM 35-23-00. NO FURTHER DEFECTS…
- 27 Aug 2016
Apu, odor
FUMES REPORTED BY AFT F/A'S. PERFORMED IDENTIFICATION OF THE CAUSE OF CABIN ODOR IAW TSM 05-50-00-810-8311-A. APU SUSPECTED TO BE AT FAULT. PERFORMED ECS…
- 17 Mar 2016
Panel, loose
OXYGEN MASK FELL OVER ROW 15. FOUND ALL OXYGEN MASKS SECURE. FILLER PANEL WAS FOUND HANGING, SECURED FILLER PANEL IAW AMM 25-25-11.
- 7 Feb 2016
Toilet, blocked
F/A REPORTS RAW SEWAGE/LIQUID SEEPING FROM FWD LAV AREA AND UNDER BULKHEAD WHERE F/A JUMPSEATS LOCATED. MAINTENANCE CONTROL AND DISPATCH REQUIRE AIR RETURN TO…
- 16 Jun 2015
Panel, loose
OXYGEN MASK COMPARTMENT LOOSE ABOVE 1 B/C. SECURED PAX PSU PANEL AT 1 B/C IAW AMM 35-21-43. NO FURTHER DEFECTS NOTED.
- 23 Apr 2015
Oxygen Mask, unwanted deploy
OXYGEN MASK, SEATS 26 DEF SELF DEPLOYED AFTER TAKEOFF. SECURED O2 MASK ASSY, CONTAINER IAW AMM 35-210. NO OTHER DEFECTS NOTED.
- 25 Feb 2015
Oxygen Mask, unsecure
16 DEF, O2 MASKS DEPLOYED. RE-STOWED MASKS AND PERFORMED TEST OF MANUAL MASK RELEASE IAW AMM 35-23-00.
- 24 Feb 2015
Oxygen Mask, unsecure
ROW 26DEF OXY MASK COMPARTMENT OPEN ON TAKEOFF. SECURED O2 PASS MASK CONTAINER IAW AMM 33-21-11.
- 5 Jan 2015
Megaphone, inoperative
FWD MEGAPHONE INOPERATIVE. R & R FWD MEGAPHONE IAW EMERGENCY EQUIPMENT LAYOUT DWG NK319-132-EQ, OPS CHECKED GOOD.
- 18 Dec 2014
Setscrew, broken
FWD MEGAPHONE SET SCREW ATTACHMENT BROKEN. R & R FWD MEGAPHONE IAW AMM 25-65-51. ALL CHECKED NORMAL
- 7 Dec 2013
Slide, unwanted deploy
R1 DOOR ESCAPE SLIDE DEPLOYED. R & R R1 DOOR ESCAPE SLIDE IAW AMM REMOVAL AND AMM INSTALL. OPS CHECKED IAW AMM, OPS CHECKED GOOD. DOOR PUT BACK TO SERVICEABLE…
- 15 Nov 2013
Cover, unsecure
DOOR RT EMERGENCY EXIT ECAM. FOUND EMERGENCY COVER FELL LOOSE, OFF ON DOOR. SECURED COVER AND DOOR LIGHT WENT AWAY FOR OVERWING EXIT. INSPECTED RT EMERGENCY…
- 10 Oct 2013
Cover, misinstalled
DURING DESCENT FROM APPROX 12,000 - 6000 FT, DOOR RT EMERGENCY EXIT ECAM. F/A CHECKED DOOR & REPORTED DOOR LIGHT ON & DOOR NOT SEALED PROPERLY. APPLIED TSM…
- 5 Oct 2013
Bottle, low pressure
LT AFT L2 SLIDE RESERVOIR PRESSURE GAUGE SHOWS AT BORDER LINE. R & R IAW AMM 25-62-44-000-012-A & 25-62-44-400-007-A. OPS CHECKED GOOD.
- 21 Sep 2013
Spar, corroded
CORROSION ON RT WING, AFT SPAR OVERHANG AT NR 3 SPOILER CENTER HINGE BRACKET INBD HING POINT. WORK ACCOMPLISHED AND CLEARED ON ROUTINE NR 7230N00361, EA T4276…
- 21 Sep 2013
Channel, corroded
BOTTOM FWD LAVATORY ATTACHMENT CHANNEL AT L1 DOOR HAS CORROSION IN CENTER ATTACHMENT HOLE. WORK ACCOMPLISHED AND CLEARED ON NON-ROUTINE 7230N00205.
- 21 Sep 2013
Spar, corroded
CORROSION ON RIGHT WING AFT SPAR OVERHANG PANEL SUPPORT JUST OTBD OF NR 3 SPOILER INBD DOGBONE. BOTH SIDES OF SUPPORT, WORK ACCOMPLISHED AND CLEARED ON…
- 21 Sep 2013
Support, damaged
LEFT WING T/E OVERHANG PANEL SUPPORT JUST OTBD OF NR 3 INBD HINGE RIB 13 & 16 DAMAGED. REPAIRED IAW EA T4277, TD-J1-52-25441-2013 AND EO 5753-1313.
- 30 Jul 2013
Oxygen Mask, dislodged
O2 MASKS FELL DOWN FROM 18B. RESTOWED O2 MASK IAW AMM 35-21-43-550-801-A PERFORMED OPS TEST OF MANUAL MASK RELEASE IAW AMM 35-23-00-710-001-A.
- 27 Jul 2013
Oxygen Mask, unwanted deploy
OXYGEN MASKS AT SEATS 8 EDF DEPLOYED ON LANDING. OP CHECKED GOOD IAW ACFT MM.
- 16 Jul 2013
Latch, faulted
PSU PANEL OPENED UP & O2 MASKS DROPPED OVER ROW 8 ACFT RIGHT. PERFORMED OPS CHECK OF MANUAL MASK RELEASE OF PASSAGER OXYGEN MASK RELEASE. TESTED OK IAW AMM…
- 4 Jul 2013
Windshield, failed
LEFT WINDSHIELD HEAT SYS MALFUCTIONED, CRACKED WINDSHIELD, ARCING FLAME VISIBLE, FUMES PRESENT. R & R LT WINDSHIELD IAW AMM OPS CHECKED GOOD NO DEFECTS NOTED…
- 11 Jun 2013
Indicator, inoperative
DURING CLIMBOUT, ISIS AIRSPEED INDICATION DISAPPEARS AND RED BOX WITH SPD DISPLAYED. FOUND CLOG ON PITOT 3. CLEANED PITOT PROBE IAW AMM 34-10-00 AND DRAIN AND…
- 4 Jun 2013
Lens, broken
LEFT OVERWING EXIT MARKER LENS BROKEN. R & R LT OVERWING EXIT MARKER LENS COVER IAW ACFT MM. OPS CHECKED GOOD.
- 16 May 2013
Oxygen Mask, unknown
SEAT 8E OXYGEN MASK HAS DROPPED. PERFORMED OPS CHECK OF MANUAL MASK RELEASE (DROP CHECK) IAW ACFT MM, NO DISCREPANCIES NOTED.
- 13 May 2013
Oxygen Mask, unwanted deploy
O2 MASKS DROPPED ABOVE ROW 8. STOWED MASKS IAW AMM 35-21-43-550-801-A. PERFORMED OP TEST OF MANUAL MASK RELEASE IAW ACFT MM. OP CHECK OK.
- 28 Mar 2013
Seal, lack of lube
LOUD VIBRATING NOISE COMING FROM L1 DOOR IN FLIGHT. LUBRICATED DOOR SEAL IAW ACFT MM AND CLEANED DEBRIS FROM GIRT BAR AND LUBRICATED GIRT BAR. REMOVED ICE AND…
- 4 Jan 2013
Engine, fluctuates
POWER FLUCTUATION DURING TAKEOFF. DURING CLIMB AT F 50 ACFT SUDDENLY YAWED ENGINE NR 1 EPR DROPPED TO ZERO ALONG WITH N1 THEN RECOVERED IT APPEARS THE ENGINE…
- 8 Feb 2012
Floor Panel, corroded
UPPER FUSELAGE PAX CABIN FLOOR PANEL WITH CORROSION AT STA 7087/FR16 AND +1800. THE DAMAGED FLOOR PANEL WAS REPLACED IAW SRM REQUIREMENTS WITH A NEW ONE.
- 8 Feb 2012
Floor Panel, corroded
UPPER FUSELAGE PAX CABIN OVER FLOOR LEVEL FROM STA7087 TO STA8077 FR20 FLOOR PANEL WITH CORROSION AT SEVERAL PLACES. DAMAGED FLOOR PANEL WAS REPLACED IAW SRM…
- 8 Feb 2012
Floor Panel, corroded
UPPER FUSELAGE PAX CABIN OVER FLOOR LEVEL, FROM STA 7087/FR16 TO STA 8077/FR20 BETWEEN -Y203 AND -Y1219, FLOOR PANEL 222EF WITH CORROSION AT SEVERAL PACES.…
- 8 Feb 2012
Floor Panel, corroded
UPPER FUSELAGE, PAX CABIN OVER FLOOR LEVEL, FROM STA7087/FR16 TO STA8077/FR20, BETWEEN -Y1219 AND -Y1600 FLOOR PANEL 222FF WITH CORROSION AT SEVERAL PLACES.…
- 6 Feb 2012
Skin, corroded
NR 1 ENGINE PYLON AFT LOWER SECTION, INBD AND OTBD SKINS FAIRING WITH CORROSION. THE DAMAGED SKIN WAS REPLACED IAW SRM 51-72-11, PARA 4 AND 6.
- 6 Feb 2012
Skin, corroded
NR 2 ENGINE PYLON AFT LOWER SECTION, INBD AND OTBD SKIN FAIRING WITH CORROSION. THE DAMAGED PARTS WERE REPLACED IAW SRM 51-72-11, PARA 4 AND 6.
- 6 Feb 2012
Attach Bracket, corroded
FUSELAGE LT MLG ACTUATOR ATTACHMENT BRACKET BEARING AREA WITH CORROSION. A TEMPORARY REPAIR WITH A LIFE OF 40000 FC MINIMUM WILL BE INSTALLED IAW REPAIR…
- 3 Feb 2012
Shear Web, corroded
UPPER FUSELAGE PAX CABIN, AFT FLOORBEAM AREA, SHEAR WEB CORRODED AT STA 29921 FR70 AND +Y1800. THE DAMAGED SHEAR WEB WAS REPLACED IAW SRM REQUIREMENTS, UNDER…
- 3 Feb 2012
Support, cracked
LOWER FUSELAGE, LT LATERAL AVIONICS COMPARTMENT, STA 7087/FR 16 ON LEVEL STRINGER 27, WASTE DRAIN DUCT SUPPORT WITH CRACK. THE DAMAGED SUPPORT WAS REPLACED…
- 1 Feb 2012
Channel, cracked
NR 2 ENGINE PYLON UPPER SECTION AT RIB 8, RT SIDE CHANNEL CRACKED. REPAIRED IAW SRM 54-52-12, FIG 208.
- 1 Feb 2012
Channel, cracked
NR 1 ENGINE PYLON UPPER SECTION AT RIB NR 7 INBD SIDE CHANNEL CRACKED. REPAIRED IAW SRM 54-52-12, FIG 208.
- 1 Feb 2012
Channel, cracked
NR 2 ENGINE PYLON UPPER SECTION AT NR 7 RIB, INBD SIDE CHANNEL WITH CRACK. REPAIRED IAW SRM 54-52-12, FIG 208.
- 1 Feb 2012
Beam, corroded
UPPER FUSELAGE PAX CABIN LT FWD DOOR SILL BEAM WITH CORROSION AT ESCAPE SLIDE GIRT BAR FITTINGS AREA. A REPAIR IS GOING TO BE PERFORMED IAW REPAIR GUIDELINES…
- 1 Feb 2012
Sill, corroded
UPPER FUSELAGE PAX CABIN RT FWD DOOR SILL BEAM WITH CORROSION AT ESCAPE SLIDE GIRT BAR FITTINGS. A REPAIRED IAW REPAIR GUIDELINES REF. NR 70557953/006 UNDER…
- 26 Nov 2011
Slide, low pressure
R2 DOOR SLIDE PRESSURE INDICATION IN THE RED. R & R R2 ESCAPE - SLIDE IAW 25-62-44, PB401.
- 8 Feb 2011
Attach Fitting, stuck
L1 DOOR GIRT BAR HOLDING CLIP STUCK DOWN. PERFORMED OPS TEST PROCEDURE OF THE GIRT BAR ASSY IAW AMM TASK 25-62-44-710-060, OPS CHECKED GOOD.
- 7 Oct 2010
Panel, corroded
L2 DOOR PANEL AT FLOOR CORRODED.
- 27 Sep 2010
Sill, corroded
RT SILL PLATE HAS CORROSION.
- 27 Sep 2010
Shear Plate, corroded
RT SHEAR PLATE HAS CORROSION.
- 27 Sep 2010
Beam, corroded
RT Z-BEAM FR 68 HAS CORROSION.
- 27 Sep 2010
Beam, corroded
RT Z-BEAM AT FR67 AND FR68 HAS CORROSION.
- 27 Sep 2010
Beam, sheared
RT Z-BEAM AT FR 69 HAS SHEARED FASTENERS.
- 26 Sep 2010
Bearing, corroded
RT ELEVATOR NR 4 HINGE BEARING IS EMITTING RUST AND SQUEAKS WHEN ELEVATOR IS MOVED.
- 26 Sep 2010
Seat Track, corroded
SEAT TRACK AT Y1292 AT FR66 HAS CORROSION.
- 26 Sep 2010
Floorbeam, corroded
FLOORBEAM AT Y-765 BETWEEN FR67 AND FR68 HAS CORROSION.
- 26 Sep 2010
Floorbeam, corroded
LT FLOORBEAM AT FR67 HAS CORROSION.
- 26 Sep 2010
Floorbeam, corroded
LT FLOORBEAM AT FR68 HAS CORROSION.
- 26 Sep 2010
Seat Track, corroded
SEAT TRACK AT Y765 AT FR 66 HAS CORROSION.
- 26 Sep 2010
Floorbeam, corroded
FLOORBEAM AT Y300 BETWEEN FR68 AND FR69 SHOWS SIGNS OF CORROSION.
- 26 Sep 2010
Seat Track, corroded
SEAT TRACK AT Y1292 AT FR 66 HAS CORROSION.
- 26 Sep 2010
Beam, sheared
LT Z-BEAM AT FR 69 HAS SHEARED FASTENERS.
- 26 Sep 2010
Bearing, corroded
LT ELEVATOR NR 4 BEARING IS EMITTING RUST.
- 24 Sep 2010
Skin, corroded
RT AFT AVX COMP CORROSION AT SKIN AIR VALVE INLET DUCT,
- 25 Jul 2010
Seal, leaking
JUST NORTH OF VOR, NOTICED AN UNUSUAL LOW OIL QTY IN THE NR2 ENG. WE ALSO HAD AN FAA MX INSP IN THE OBSERVERS SEAT. A 3 DAY SERVICE CHECK WAS DONE THE NIGHT…
- 31 Jul 2009
Valve, failed
NR 1 BLEED FAULT FOLLOWED BY LOSS OF CABIN PRESSURE. PERFORM ECAM EMERGENCY DECENT. ACFT WAS FERRIED.
- 20 Feb 2009
Floorbeam, corroded
FOUND CORROSION ON FLOORBEAM AT FR69 Y254. REMOVED AND REPLACED FLOORBEAM.
- 19 Feb 2009
Floorbeam, corroded
EVIDENCE OF CORROSION AT FR 68 AND Y765 BELOW AFT GALLEY. REMOVED AND REPLACED FLOORBEAM.
- 19 Sep 2007
Floorbeam, corroded
FLOORBEAM AT Y765 BETWEEN FR 67 AND FR 69 HAS CORROSION. REPLACED FLOORBEAM.
- 19 Sep 2007
Floorbeam, corroded
FLOORBEAM AT -Y765 FR 66 CORRODED. REPLACED FLOORBEAM.
- 19 Sep 2007
Floorbeam, corroded
FLOORBEAM AT Y765 AND FR 66 CORRODED. REPLACED FLOORBEAM.
- 19 Sep 2007
Floorbeam, corroded
FLOORBEAM AT R-2 DOOR ENTRANCE BETWEEN FR67 AND FR68 (-Y1292) CORRODED. REPLACED FLOORBEAM.