N513UA
1990 Boeing 757-222 standard FAA →
earlier registrations
1 past record
- 1990
service difficulty reports
126 reports
- 10 Mar 2014
Frame, corroded
FRAME AT BS 1360 RBL 28 HAS CORROSION AT CARGO TIE DOWN.
- 10 Mar 2014
Frame, corroded
CORROSION ON FRAME IN AFT CARGO COMPARTMENT BS 1520 RBL 7 - LBL 7 MULTIPLE AREAS.
- 10 Mar 2014
Frame, corroded
FRAME AT BS 1360 RBL 28 HAS CORROSION AT CARGO TIE DOWN.
- 10 Mar 2014
Frame, corroded
CORROSION ON FRAME IN AFT CARGO COMPARTMENT BS 1520 RBL 7 - LBL 7 MULTIPLE AREAS.
- 2 Mar 2014
Crease Beam, corroded
CORROSION ON WEB BETWEEN STATION 1060L - 1080L ON TOP OF CREASE BEAM. REPAIRED CREASE BEAM WEB FROM STATION 1060L - 1080L.
- 26 Feb 2014
Floorbeam, cracked
CRACK IN RADIUS BETWEEN THE UPPER CORD & THE WEB OF THE MAIN CABIN FLOOR BEAM STATION 680, LBL 24.75.
- 23 Feb 2014
Pin, missing
LT SIDE OVERWING SLIDE DEPLOY PIN & CABLE NOT INSTALLED. INSTALLED LT SIDE OVERWING SLIDE DEPLOY PIN IAW B757 AMM 25-65-01.
- 11 Jan 2014
Warning Message, false activation
SPOILER EICAS MESSAGE IN FLIGHT. ACCOMPLISHED FIM 27-61-00-101, FIG 103, 27-09-00-101, FIG 105A. NO EXISTING FAULTS FOUND ON ALL SCM'S. SCM 1R SHOWED…
- 20 Dec 2013
Connector, defective
AUTO SPEED BRAKE DID NOT DEPLOY ON LANDING. REPLACED S10697 & CONNECTOR RT GEAR TILT SWITCH IAW WDM 27-62-01. AUTO SPEED BRAKE OPERATIONS CHECKED GOOD.
- 19 Nov 2013
Skin, delaminated
LT ENGINE NACELLE DELAMINATING. AT 10:00 POSITION A 2.5 BY 11 INCH AREA OF SKIN HAS BECOME DISBONDED AT LE. TAPPED ENTIRE AREA & FOUND TO BE SOLID, INTERIM…
- 13 Nov 2013
Release Cable, misinstalled
LT OFF WING SLIDE RELEASE CABLE NOT INSTALLED CORRECTLY. IT IS INSTALLED ON TOP OF BRACKETS NOT IN BETWEEN AS IN FIGURE 1 IAW FCD 2560-02556. NEED TO INSTALL…
- 10 Aug 2013
Warning Light, malfunctioned
AT ALTITUDE LT RECIRCULATION FAN ANNUNCIATOR LIGHT CYCLES ON AND OFF WITH ACCOMPANIED OVERHEAD LIGHT.
- 5 Aug 2013
Wire, faulty
AT ALTITUDE LT RECIRCULATION FAN ANNUNCIATOR LIGHT CYCLES ON AND OFF WITH ACCOMPANIED OVERHEAD LIGHT. FOUND WIRE FAULTY.
- 17 Jun 2013
Lamp, inoperative
R4 DOOR SLIDE LIGHT IS OUT. REPLACED LAMPS, LIGHT OPS OK.
- 13 Jun 2013
Lens, damaged
CREW REPORTS THAT DOOR 4R HAS DAMAGE ON BUSTLE INFLATION CYLINDER PRESSURE GAGE VIEWING WINDOW. PLASTIC IS CRACKED AND PUSHED IN. PERFORMED INTERIM REPAIR…
- 25 Apr 2013
Skin, dented
LEFT FUSELAGE SKIN BS 520-660, S14-20L, HAS NUMEROUS DENTS. REPAIRED PER REO G12078 REV 'A' AND EVA 70421.
- 22 Apr 2013
Cap, missing
THE TERMINATING ENDCAPS ARE MISSING ON THE ESCAPE PATH FLOOR LIGHTING AT SEATS 1, 6, 8 AND 40. REPLACED FOUR EMERGENCY LIGHT END CAPS.
- 8 Apr 2013
Door, cracked
LEFT MAIN WING ACCESS FUEL DOOR CRACKED. REPLACED LEFT WING FUEL PANEL.
- 7 Apr 2013
Warning Bell, no test
FIRE BELL FAILED TO RING DURING FIRE OVERHEAT TEST. OTHER FIRE INDICATIONS NORMAL. ACCOMPLISHED ENGINE FIRE OVERHEAT DETECTOR FIM 26-11-00-815-802. RESET…
- 13 Mar 2013
Fire Bottle, low pressure
PORTABLE FIRE EXTINGUISHER NEAR L1 DOOR, LOW PRESSURE PER AMM. REPLACED FIRE EXTINGUISHER PER AMM.
- 1 Feb 2013
Controller, failed
AFT CABIN AUTO CONTROL FAILURE. INOPERATIVE LIGHT ON. AFT ZONE TEMP CONTROLLER FAULTED. REPLACED TEMP CONTROLLER PER MM, OPS CHECKED NORMAL.
- 31 Jan 2013
Test Switch, failed
CAPTAIN`S OXYGEN MASK RESET - TEST SLIDER SWITCH IS STICKING AND NOT WORKING PROPERLY. REPLACED O2 STOWAGE BOX, NO LEAKS NOTED, SERVICED OXYGEN, SAFETIED…
- 27 Dec 2012
Light, missing
DOOR 2L SLIDE ARMED LIGHT MISSING. REPLACED SLIDE ARMED LIGHT, OP CHECK OKAY.
- 4 Nov 2012
Scavenge Pump, leaking
NR 2 ENGINE, INSIDE TAILPIPE IS SOAKED WITH ENGINE OIL. SERVICED NR 2 ENGINE WITH 9 QUARTS OF OIL. CLEANED TAILPIPE OF OIL ACCOMPLISHED ENGINE IDLE RUN PER…
- 30 Oct 2012
Terminal, bent
SLIDE LIGHTS INOP AT 4L AND 4R. FOUND DOOR 4L SLIDE INDICATOR TERMINAL 2 BENT OVER AND TOUCHING TERMINAL C, MADE CLEARANCE AND OPS OK. DOOR 4R HAS A BROKEN…
- 30 Oct 2012
Barrier, faulty
SECONDARY BARRIER LATCH WILL NOT ENGAGE. REPLACED SECONDARY BARRIER, LATCHES ENGAGED.
- 26 Oct 2012
Skin, damaged
AFT ACCESSORY DOOR HAS DENT NEAR TRAILING EDGE JUST LEFT OF ACCESS HANDLE. REPLACED DAMAGED DOOR OUTER SKIN IN REF TO ECRA 5240-01664.
- 25 Oct 2012
Skin, dented
L1 DOOR EXT SKIN IS DENTED AT THE LOWER AFT SECTION.
- 22 Oct 2012
Skin, gouged
GOUGES ON LWR FUSELAGE SKIN AT STA 565 & BETWEEN S-26L AND S-27L. INSTALLED INTERIM REPAIR AT LOCATION PER ECRA 5330-04344. CF REQUIRED FOR REPEAT INSPECTIONS.
- 22 Oct 2012
Skin, dented
FUSELAGE SKIN DENT STA 613 BETWEEN S-15L AND S-16L. INSTALLED INTERIM REPAIR AT LOCATION PER ECRA 5330-04346. PER ECRA CF REQUIRED FOR REPEAT INSP.
- 22 Oct 2012
Skin, dented
SMALL DENT REPORTED BY RAMP AND LOCATED PROX AT 6 FEET FWD OF DOOR 2L THRESHOLD LEVEL AREA. SAMC TEXT: DAMAGE IS AT STR 575 AND WL S15, IT IS APPROX 2 INCH…
- 22 Oct 2012
Skin, dented
FUSELAGE HAS DENT AT STA 1630 JUST BELOW STR 15L. AT C CHECK FOUND DENT TO BE AT STA 1607 NOT 1630 AND OUT OF LIMITS. INSTALLED INTERIM REPAIR PER ECRA…
- 22 Oct 2012
Skin, dented
L1 DOOR EXT SKIN HAS DENT LWR AFT SECTION. INSTALLED INTERIM REPAIR PER ECRA 5210-02322.
- 22 Oct 2012
Skin, corroded
L1 DOOR EXT SKIN HAS DENT LOWER AFT SECTION.
- 21 Oct 2012
Skin, damaged
SKIN BLEND OUT STA 500 AT S-16L REF SCAL L P 9984310. INTERIM REPAIR INSTALLED STA 500 AT S-16L PER ECRA 5330-04345.
- 21 Oct 2012
Floorbeam, corroded
STA 365 FLOORBEAM UPPER CAP HAS CORROSION BETWEEN BL 0 AND RBL 61. REF SCAL LP 9985010. MAJOR REPAIR ACCOMPLISHED: REPLACED UPPER FLOORBEAM T-CHORD STA 365.25…
- 21 Oct 2012
Pressure Deck, corroded
STA 1681 PRESSURE DECK CORRODED AT PREVIOUS REPAIRR BETWEEN RBL 12 AND RBL 46. MAJOR REPAIR ACCOMPLISHED: REMOVED PREVIOUS REPAIR & INSTALLED NEW REPAIR…
- 21 Oct 2012
Skin, dented
FUSELAGE DENT STA 1607 BELOW S-15L. MAJOR REPAIR ACCOMPLISHED: INTERIM REPAIR DOUBLER INSTALLED REQUIRES A CF FOR REPEAT INSP REF ECRA 5330-04348. ACCOMPLISH…
- 21 Oct 2012
Floorbeam, corroded
STA 1640 FLOORBEAM UPPER CAP HAS CORROSION BETWEEN LBL 12 AND RBL 60. REF SCAL LP 9984854. MAJOR REPAIR ACCOMPLISHED: REPLACED CORRODED SECTION OF FLOORBEAM…
- 21 Oct 2012
Floorbeam, corroded
STA 1660 FLOORBEAM UPPER CAP HAS CORROSION AT LBL 1. MAJOR REPAIR ACCOMPLISHED: CUT OUT CORROSION DAMAGE. FABRICATED 2 REPAIR ANGLES, FILLER, STRAP AND…
- 21 Oct 2012
Floorbeam, corroded
STA 1681 FLOORBEAM UPPER CAP HAS CORROSION BETWEEN RBL 24 AND RBL 53. MAJOR REPAIR ACCOMPLISHED: REMOVED, FABRICATED AND INSTALLED REPLACEMENT FLOORBEAM AT…
- 6 Oct 2012
Floorbeam, corroded
STA 324 FLOORBEAM HAS CORROSION ON UPPER CAP RBL 40-60. MAJOR REPAIR ACCOMPLISHED: INSTALLED NEW UPPER CAP TO FLOORBEAM AT STA 324 REF SRM 53-10-01 REPAIR 1.
- 28 Sep 2012
Pan, chafed
L2 DOOR EXTERIOR HANDLE PAN HAS CHAFE MARK. REMOVED AND REPLACED DOOR HANDLE PAN PER SRM 51-40-02.
- 28 Sep 2012
Pan, chafed
R4 DOOR EXTERIOR HANDLE PAN HAS CHAFE MARK. REMOVED AND REPLACED DOOR R4 HANDLE PAN PER SRM 51-40-02.
- 27 Sep 2012
Pan, chafed
L1 DOOR EXTERIOR HANDLE PAN HAS CHAFE MARK. REMOVED AND REPLACED L1 DOOR HANDLE PAN REF SRM 51-40-02.
- 27 Sep 2012
Pan, chafed
L4 DOOR EXTERNAL HANDLE PAN HAS CHAFE MARK. REMOVED AND REPLACED L4 DOOR EXTERNAL PAN REF SRM 51-40-02 AND CMM 52-11-25.
- 22 Sep 2012
Structure, damaged
DOUBLER INSTALLED STA 1392 BETWEEN S-30 AND S-29L REQUIRES REPEAT INSPECTION PER SRM 53-00-01 REPAIR 3 TABLE V. DOUBLER INSTALLED STA 1392 BETWEEN S-30 AND…
- 22 Sep 2012
Fastener, damaged
FOUND OLD LIGHTNING STRIKE AT STA 1540 BETWEEN RT STR 2 AND RT STR 3. MM 53-30-95 ALLOWS REPLACEMENT OF FASTNERS AT HMV. CORRECT LOCATION OF FASTENER IS STA…
- 22 Sep 2012
Fastener, damaged
FOUND LIGHTNING STRIKE AT STA 1540 & LEFT STRINGER 5 (0 BEING AT TOP). TEMPORARY REPAIR REF SRM 5 3-00-01. REMOVED BLIND FASTENER AND REPLACED WITH A SOLID…
- 22 Sep 2012
Fastener, damaged
STA 1470 BETWEEN STR 1 AND RIGHT STR 2. FOUND OLD LIGHTNING STRIKE AT STA 1470 BETWEEN STR 1 AND RIGHT STR 2. ACCOMPLISHED TEMP REPAIR REF SRM53-00-01. WILL…
- 22 Sep 2012
Fastener, damaged
FOUND LIGHTING STRIKE AT STA 1560, LEFT STRINGER 5, (0 STRINGER AT TOP). REMOVED BLIND FASTENER AND REPLACED WITH A SOLID RIVET.
- 2 Sep 2012
Light, inoperative
FIRST CLASS SECTION OF FLOOR EMERGENCY LIGHTING INOPERATIVE. REPLACED LIGHT ASSY, OPS CHECKED GOOD.
- 25 Jun 2012
Computer, faulted
EMERGENCY DOORS MESSAGE DISPLAYED AT LIFTOFF. REPLACED CD, LT EICAS COMPUTER REPLACED. REMOVED, INSTALLED AND ADJUSTED OVERWING HATCH IAW MM 52-22-01.
- 24 Jun 2012
Target, out of adjust
EMERGENCY DOORS MESSAGE, RTFL. FOUND L4 DOOR PROXMITY SWITCH TARGET OUT OF ADJUSTMENT. ADJUSTED TARGET & SECURED LOCKING NUT, OPS CHECKED NORMAL PER MM.
- 24 Jun 2012
Target, out of adjust
FOUND L4 DOOR PROXIMITY SWITCH TARGET OUT OF ADJUSTMENT. ADJUSTED TARGET AND SECURED LOCKING NUT, OPS CHECKED NORMAL.
- 7 Mar 2012
Fuel Line, leaking
LEFT WING HAD FUEL LEAKING OUT OF WING DRY BAY HOLES FOUND DURING WALK FOR 3 SVC CHECK. RUNNING LEAK AT MOST INBOARD DRY BAY HOLE WHEN ENGINE FUEL FEED LINE…
- 21 Oct 2011
Girt Bar, obstructed
DOOR 1L IS HARD TO ARM AND DISARM. CLEANED EXCESSIVE DIRT FROM GIRT BAR AREA.
- 2 Jul 2011
Windshield, faulty
R1 WINDSHIELD EXTREMELY COLD IN FLT COMPARED TO OTHER WINDSHIELDS. NO OTHER FAULTS NOTED. REPLACED WINDSHIELD. ACCOMPLISHED, 1ST TORQUE AT 02 JULY 2011, 0830.
- 12 May 2011
Lead, damaged
EMERGENCY PATH FLOOR LIGHTING IS INOP FROM SEAT ROW 33 LEFT AND AFT. REPLACED DAMAGED LEAD ASSY AT ROW 33. RETESTED THE EMERGENCY LIGHT SYSTEM AND LIGHT CHECK…
- 8 Mar 2011
Wire, broken
EMERGENCY EXIT IND LIGHTS INOP AT LEFT FWD OVERWING EXIT AND RIGHT AFT OVERWING EXIT. REPAIRED BROKEN WIRE W3532-0694-18 WITH SPLICE 8 INCHES FROM CONNECTOR…
- 27 Feb 2011
Duct, dirty
LT/RT RECIRCULATION FANS SO LOUD THAT CHECKLIST RESPONSES AND COCKPIT COMMUNICATIONS ARE HARD TO HEAR. WHENEVER CREW USES HAND MICROPHONE IN FLIGHT, ATC HAS…
- 5 Feb 2011
Relief Valve, faulty
AIR NOISE REPORTED LT SIDE FWD OF DOOR 3L, CHECK POSITIVE PRESS RELIEF VALVES. MX REPORTED APU PNEUMATIC DUCT LEAKING AT CLAMP LOCATED AT STA 1410 (AFT PIT-LT…
- 28 Jan 2011
Clamp, faulty
AIR NOISE REPORTED, LT SIDE FWD OF DOOR 3L. SEE THIS AND CHECK POSITIVE PRESS RELIEF VALVES. LOCAL MECH REPORTS APU PNEUMATIC DUCT LEAKING AT CLAMP LOCATED AT…
- 19 Jan 2011
Crank Assy, broken
FOUND DOOR 1R EMERGENCY SLIDE ARMING MECHANISM BROKEN. REPLACED CRANK. INSPECTED INSTALLATION, SAFETY AND SECURITY.
- 20 Oct 2010
Pressure Switch, faulty
ENG FUEL FILTER EICAS, RTFL. REPLACED FUEL FILTER AND INSP. NO FAULTS NOTED. REPLACED FUEL FILTER DIFFERENTIAL PRESSURE SWITCH. RAN ENG. STATUS AND LIGHT GONE…
- 30 Jun 2010
Monitor, sparks
PAX REPORT SAW SPARKS IN OVERHEAD MONITOR AT ROW 27. MAINT REPLACE OR DEACTIVATE MONITOR BEFORE FLIGHT AND APPLY MEL 2520GY. PLACED DEFERRAL PER SAM-C FOR…
- 6 Jul 2009
Bearing, damaged
DOOR 4R DIFFICULT TO DISARM. REMOVED DOOR 4R ESCAPE SLIDE TO ACCESS DOOR ARM-DISARM LEVER MECHANISM. FOUND BEARINGS MIGRATING AND RUSTED AT UPPER TORQUE SHAFT…
- 6 Apr 2009
Skin, cracked
SKIN CRACKS FOUND ON F/O WALKAROUND UNDER LT WING OUTSIDE ENGINE POD. CLOSE INSPECTION FOUND ACCESS PANEL 521AB (ACCESS PLATE FOR LEADING EDGE SLAT OUTBOARD…
- 5 Jan 2009
Actuator, faulty
UPON GEAR EXTENSION, *GEAR DISAGREE* DISPLAYED, NO NOSE GREEN LIGHT, CYCLED GEAR TWICE, NO HELP, USED ALT GEAR EXTEND, GEAR INDICATION NORMAL. GEAR DOORS…
- 5 Nov 2008
Battery, inoperative
EMERGENCY EEL LIGHT STRIP SECTION INOP AFT OF ROW 27. REPLACED BATTERY PACK AND ONE EEL LIGHT STRIP. OP CKS NORMAL.
- 2 Jul 2008
Bottle, leaking
LOW BOTTLE PRESSURE. PRESSURE GAUGE LOCK NUT LOOSE. TIGHTENED AND REFILLED.
- 29 Jun 2008
Eec, malfunctioned
NR 2 ENG UNCOMMANDED ROLLBACK FOR 30 SECONDS. RTFL. POSSIBLE INTERNAL EEC ISSUE. REPLACED EEC AND PMA STATOR AS PRECAUTIONARY, NO REPEATS.
- 21 Jun 2008
Slide, out of tolerance
SLIDE PRESSURE AT DOOR 4L OUT OF GREEN BAND. REPLACED SLIDE ASSY, OPS CHECKED GOOD.
- 29 May 2008
Light, unsecure
EXIT PATH LIGHTING STRIP IN REAR OF AIRCRAFT HAS COME LOOSE, LAST ROW IN COACH. RE-INSTALLED EEL LIGHTING, ALL OPS TESTS NORMAL.
- 18 May 2008
Connector, loose
EEL STRIP INOP OUTSIDE OF LAV FWD OF DOOR 4L LOOSE. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SECURED LOOSE CONNECTION.
- 18 May 2008
Lamp, inoperative
EMERGENCY AISLE LIGHT BELOW STOW BIN AT SEATS 11 ABC INOP. SUPPLEMENTAL DATA UPDATE CAUSE, LAMP INOP. RELAMPED, OPS CHECKED NORMAL.
- 18 May 2008
Lens, missing
EMERGENCY AISLE LIGHT BELOW STOW BIN AT SEATS 23DEF MISSING LENS COVER. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. INSTALLED MISSING LENS COVER.
- 2 Apr 2008
Light, unsecure
EMERGENCY TRACK LIGHTING BY ROWS 27-29 HAS POPPED OUT. SECURED FLOOR TRACK COVER CHKS OK
- 31 Mar 2008
Smoke Goggles, damaged
CAPT SMOKE GOGGLE DAMAGED. REPLACED SMOKE GOOGLE.
- 2 Jan 2008
Light, inoperative
PER CREW, FIRE BOTTLE SQUIB TEST LIGHT DOES NOT ILLUMINATE. REPLACED CAP ASSY AS PRECAUTIONARY. TEST NORMAL. ENGINE DISCHARGE LIGHT ON PEDESTAL DOES NOT…
- 19 Dec 2007
Light, missing
EMERGENCY FLOOR LIGHTING AT ROWS 28-30 LOOSE & INTERNAL LIGHTING STRIP MISSING. APPROX 80 INCHES OF LIGHT STRIP IS MISSING. APPEARS TO BE RIPPED OUT. REPAIRED…
- 15 Dec 2007
Light, unsecure
EMERGENCY EXIT LIGHTS COMING UP NEAR ROW 28. SECURED TRACK COVER.
- 8 Dec 2007
Light, unsecure
29C 30C EMERGENCY STRIP LIGHT IN THE FLOOR IS TORN UP. SECURED AND OPS TESTED OK.
- 13 Sep 2007
Light, unsecure
EMERGENCY LIGHTING POPPED OUT OF FLOOR AT 30 ABC. 10-9-07 SECURED FLOOR LIGHTING.
- 6 Sep 2007
Light, inoperative
EMERGENCY ESCAPE PATH LIGHTS AT ROWS 23-30 INOP. REPLACED ONE LAMP AND SECURED SAME.
- 5 Sep 2007
Light, torn
EMERGENCY LIGHT STRIP AT ROW 28 TORN AND DOES NOT ILLUMINATE. REPLACED DAMAGED EEL STRIP AND SECURED IT AS PER SPECIFICATIONS.
- 24 Aug 2007
Power Supply, faulty
ESCAPE PATH LIGHTING INOP ROWS 25 TO 30.
- 30 Jul 2007
Webbing, out of position
PASSENGER ENTRY-SERVICE DOORS L FWD EVAC SLIDE ARM LEVER DIFFICULT TO POSITION. REPOSITIONED SLIDE GIRT BAR WEBBING FROM DOOR ARMING MECHANISM.
- 30 Jul 2007
Reservoir, low pressure
DOOR 1L EMERGENCY POWER RESERVOIR PSI LOW. REPLACED EMERGENCY POWER RESERVOIR FOR DOOR 1R AND ACCOMPLISHED BOTTLE INSPECTION.
- 17 Jul 2007
Strap, loose
R2 DOOR WILL NOT ARM. [08-17-07] REMOVED BUSTLE, TIGHTENED STRAPS AND OPS CHECKED OKAY. REINSTALLED BUSTLE.
- 14 Jul 2007
Skin, cracked
MED 2R UPPER HINGE CUTOUT CRACKED. MAJOR REPAIR ACCOMPLISHED: INSURANCE CUT & INSTALLED A DOUBLER REPAIR.
- 13 Jul 2007
Skin, dented
LEFT EXTERNAL FUSELAGE AT EXISTING REPAIR DOUBLERS STA 520-660, STR 14L-20L, SKIN HAS NUMEROUS DENTS.
- 13 Jul 2007
Fitting, gouged
RIGHT WING (PYLON) FITTING (SIDE LINK) FASTNER HOLE AT LOCATION F ON WING HAS INTERNAL GOUGE DAMAGE. 09-07-07 MAJOR REPAIR ACCOMPLISHED. PANEL ON PYLON 432AR…
- 13 Jul 2007
Battery, faulty
LEFT & RIGHT FWD EMERGENCY LIGHTS INOP, EXTERIOR. [07-27-07] TROUBLE SHOOT AND REPLACED BATTERY. OPS CHECK GOOD.
- 12 Jul 2007
Skin, damaged
LEFT EXTERNAL FUSELAGE AT EXISTING REPAIR DOUBLER, FOUND STR 16L AT STA 625 HAS AN ENLARGED HOLE. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE SECTION OF…
- 12 Jul 2007
Oxygen Mask, faulty
THE O2 MASKS DID NOT DROP DURING OPS CHECK IN MAIN CABIN AT ROWS 6AB, 4AB, 4CD, 10ABC, 27ABC & FWD F/A SEAT. [08-17-07] ELECTRICAL OPS CHECK TURNED OUT TO BE…
- 7 Jul 2007
Girt Bar, corroded
R-4 DOOR, GIRT BAR RESTRAINT PLATE CORRODED. [08-08-07] REPLACED GIRT BAR RESTRAINT FITTING.
- 30 Jun 2007
Structure, damaged
MED 2L IS DAMAGED AT UPPER HINGE CUTOUT. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.
- 26 May 2007
Acm, inoperative
FLIGHT DIVERTED AFTER THE CABIN WOULD NOT PRESSURIZE. [08-07-07] FOUND ACM NOT RUNNING. ACCOMPLISHED SERVICE TIP AND OP CHECKED OK.
- 15 Mar 2007
Door Frame, cracked
THE 2L MED UPPER HINGE FRAME CUTOUT LWR RADIUS CRACKED. MAJOR REPAIR ACCOMPLISHED: COMPLETED A DOUBLER REPAIR ACCORDING TO A BOEING APPROVED REPAIR.
- 1 Nov 2006
Wheel, vibration
NOSE WHEEL VIBRATES DURING TAXI, TAKEOFF AND LANDING. PULLING DUE TO RUDDER BEING IMPROPERLY RIGGED. RUDDER RIGGED AS PER SPECIFICATION. RUDDER NOW NEUTRAL.…
- 10 Oct 2006
Unknown, unknown
DURING DESCENT INTO ORD NO RUDDER TRIM LT OR RT. REPLACED RUDDER TRIM FEEL CENTERING/TRIM ACTUATOR.
- 6 Apr 2006
Oven, overheated
FLIGHT ATTENDANT REPORTED ODOR OF SMOKE IN FWD GALLEY AREA. FLIGHT ATTENDANT REPORTS OVEN OVERHEATING AND CAUSING GALLEY CEILING TO GET VERY HOT. OVEN WAS…
- 4 Oct 2005
Light, cut
ROW 23 THROUGH 24 EEL LIGHTS INOP. REPAIRED CUT IN STRIP. REPLACED STRIP AT SEAT 25.
- 23 Jul 2005
Lamp, burned out
EMERGENCY AISLE ILLUMINATION LIGHT INOP AT ROW 5. REPLACED LAMP.
- 18 Jul 2005
Slide, leaking
TUBE ASSY FAILED AIR RETENTION TEST DUE TO EXCESSIVE POROSITY LEAKING THROUGH TUBE FABRIC NOTED ON VARIOUS LOCATIONS. DURING COMPONENT SHOP MAINTENANCE SLIDE…
- 16 Jan 2005
Aspirator, distorted
FOUND ASPIRATOR FLATTENED DURING INSPECTION FOR OVERHAUL. ASPIRATOR MIXING TUBE WAS DISTORTED AT DISCHARGE END. IT IS SUSPECTED THAT ASPIRATOR HAD BEEN…
- 13 Apr 2004
Schrader Valve, failed
LOW BOTTLE PRESSURE. LEAK DETECTED. REPLACED SCHRADER VALVE. OSV, WINSLOW, HAS ADDED ULTRASONIC LEAK DETECTION TO BOTTLE INSPECTION PROCESS.
- 2 Jun 2002
Oil Filter, obstructed
RIGHT ENGINE OIL FILTER BYPASS LIGHT ILLUMINATED. BOTH THE DELTA "P" SWITCH AND THE FILTER WERE FORWARDED TO PWA FOR INVESTIGATION. THE SWITCH WAS FOUND TO BE…
- 4 May 2002
Oil Filter, dirty
RIGHT ENGINE OIL FILTER LIGHT ILLUMINATED. OIL FILTER AND CHIP DETECTORS CHECKED CLEAN. BYPASS SWITCH CHECKED GOOD. OIL FILTER REPLACED.
- 30 Jun 2001
Crease Beam, corroded
CABIN LT CREASE BEAM CORRODED. EXCESSIVE MATERIAL LOSS DURING CORROSION REMOVAL AT BS 757. REMOVED DAMAGE. INSTALLED NEW ANGLE WITH 2 SUPPORT STRAPS. MAJOR…
- 30 Jun 2001
Crease Beam, corroded
CORROSION ON RT CREASE BEAM, INBOARD CHORD, AT BS 324, RBL 60. REMOVED AND REPLACED CREASE BEAM DOUBLER. MAJOR REPAIR ACCOMPLISHED.
- 29 Jun 2001
Floorbeam, corroded
CABIN FLOORBEAM CORRODED. HEAVY MATERIAL LOSS DURING CORROSION REMOVAL AT BS 324, RBL 41 TO RBL 60. REPLACED T-CAP AND INSTALLED SUPPORT ANGLES. MAJOR REPAIR…
- 29 Jun 2001
Crease Beam, corroded
CABIN CREASE BEAM CORRODED. HEAVY MATERIAL LOSS DURING CORROSION REMOVAL AT BS 720-BS 760, RBL 60. REMOVED CORROSION. REPLACED CREASE BEAM ANGLE. MAJOR REPAIR…
- 26 Jun 2001
Frame, dented
AFT CARGO CIRCUMFERENTIAL FRAME DENTED STA 1400, BETWEEN STR 25L AND 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER AND STRAP REPAIR.
- 26 Jun 2001
Floorbeam, corroded
FLOORBEAM T-CAP CORRODED STA 380, LBL 48 AND LBL 58. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED T-CAP SPLICE REPAIR.
- 25 Jun 2001
Floorbeam, corroded
FLOORBEAM CORRODED STA 365, BL 0 TO RBL 64. MAJOR REPAIR ACCOMPLISHED. REPLACED UPPER T-CAP.
- 23 Jun 2001
Frame, dented
FRAME DENTED STA 1420, BETWEEN STR 25L AND 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.
- 21 Jun 2001
Floorbeam, corroded
FLOORBEAM CAP CORRODED. STA 1640, LBL 6 AND RBL 62. MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE SPLICE.
- 10 Jun 2001
Skin, damaged
DAMAGE FOUND AT THE PRODUCTION BUTT JOINT OF THE UPPER FUSELAGE SKINS AT BODY STATION 661 AND STRINGER 4R. INSTALLED DOUBLER REPAIR TO DAMAGED AREA. THIS WAS…
- 10 Jun 2001
Pressure Panel, corroded
CORROSION FOUND ON THE FORWARD EDGE OF THE AFT PRESSURE DECK AT BODY STATION 1681. INSTALLED DOUBLER REPAIR TO DAMAGED AREA. THIS WAS A MAJOR REPAIR.
- 30 Jan 1999
Mask, leaking
DIVERTED TO ORD DUE TO DECREASING CREW OXYGEN PRESSURE. *S/D* THE HOSE TO THE OBSERVER OXYGEN MASK BOX WAS REPLACED BECAUSE IT WAS FOUND LEAKING.
- 24 Sep 1997
Tube, failed test
DURING OVERHAUL OF SLIDE REMOVED FOR TIME EXPIRATION THE LOWER TUBE FAILED THE AIR RETENTION TEST. FAILURE DUE TO POROSITY IN THE LOWER TUBE INFLATABLE…
- 22 Aug 1997
Slide, loose
EVACUATION SLIDE LEVER FAILED TO MOVE/BINDING AT DOOR 1L. *S/D* SLIDE PACK CAME LOOSE. RECONNECTED ADJUSTABLE STRAP TO LATCH.
- 16 Mar 1997
Snubber, corroded
ON ARRIVAL AT ORD, FLIGHT ATTENDANT WAS UNABLE TO FULLY OPEN NR ONE LEFT PASSENGER DOOR. DOOR OPENED ONLY THREE-FOURTHS OF THE WAY. FOUND THE ROTARY SNUBBER…
- 9 Mar 1997
Fan, failed
PER CREW, SMOKE AND ODOR OCCURRED IN FLIGHT. SMOKE AND ODOR CAUSED BY FAILURE OF FORWARD EQUIPMENT COOLING FAN. REPLACED FORWARD EQUIPMENT COOLING FAN.