N511UA
Bombardier INC DHC-8-402 FAA →
earlier registrations
1 past record
service difficulty reports
118 reports
- 2 Mar 2015
Skin, damaged
THIS NON-ROUTINE IS TO CAPTURE FABRICATION OF THE REPAIR DOUBLER AT BS 1393, BL0, IAW COA 50745 & TASK CARD 59745401C, DUE TO THIS REPAIR CAN BE ACCOMPLISHED…
- 26 Feb 2014
Unknown, smoke
SMOKE IN COCKPIT & CABIN AT CLIMB POWER WITH LT PACK RUNNING. TURNING OFF PACK STOPS SMOKE IAW SERVICE TIP MM 79-00-95-901.
- 31 Dec 2013
Fseu, malfunctioned
FLAP SLAT SENSOR CB POPPED. REPLACED FSEU 1 IAW AMM 2 7-51-01. ALL TESTS PASSED.
- 12 Nov 2013
Audio Panel, defective
LT VHF COMM AUDIO RECEPTION POOR AT 1 POSITION. RECEPTION OK AT OTHER CREW POSITIONS, 01=CAPT POSITION, 02=1ST OFF POSITION & 03=OBS POSITION. REPLACED CAPT…
- 17 Sep 2013
Light, inoperative
EMERGENCY FLOOR TRACK LIGHTING WILL NOT ILLUMINATE AT ROW 8 THRU ROW 20 WHEN TESTED.
- 15 Sep 2013
Unknown, malfunctioned
CENTER PUMP SHOWS RUNNING WITH THE FUEL PANEL CLOSED.
- 5 Sep 2013
Oil Filter, contaminated
RT ENGINE OIL FILTER EICAS AFTER START, TEMPERATURE ABOVE 35. SHUTDOWN IAW CHECKLIST. FOUND METAL IN MAIN OIL. EXAMINED CONTAMINATION IAW AMM 79-00-99 PG203.…
- 1 Sep 2013
Hydraulic Line, leaking
FOUND HYDRAULIC LEAK FROM THE LT MLG DOWNLOCK ACTUATOR LINES. PCN 170-5394 & 170-5393. REPLACED LINE 170-5393 REF IPC 32-32-51-015. OLD LINE REMOVED REF IPC…
- 8 Aug 2013
Floor Panel, damaged
AISLE FLOOR FROM ROW 4 THRU 6 IS SOFT AND SPONGY.
- 12 Jul 2013
Oxygen Mask, failed
CAPTAIN`S OXYGEN MASK SUPPLY IS RESTRICTED. INSTALLED NEW MASK, OPS CHECKED OK.
- 4 Jul 2013
Actuator, tripped
ON APPROACH, WHEN SELECTING FLAPS 1 A "L/E SLAT DISAGREE" MESSAGE WAS DISPLAYED ON EICAS. DUE TO SHORT RUNWAY ACFT DIVERTED. BITE FSEU'S NR 1 MESSAGE 310,…
- 30 Jun 2013
Windshield, arced
WINDOW EICAS MESSAGE DISPLAYED. INOPERATIVE LIGHT ILLUMINATED, INOPERATIVE LIGHT DID NOT EXTINGUISH WHEN SWITCH WAS CYCLED TO OFF THEN ON. FOUND L3 WINDOW AT…
- 6 Jun 2013
Cap, missing
EMERGENCY LIGHT END CAP IS MISSING BY SEAT 1B AND 6B. INSTALLED NEW END CAP AND SECURED.
- 6 Jun 2013
Cap, missing
EMERGENCY LIGHT END CAP MISSING AT SEATS 8C & 12C REPLACED END CAP.
- 28 May 2013
Bottle, missing
OXYGEN BOTTLE MISSING. REPLACED BOTTLE.
- 22 May 2013
Light, unsecure
EMERGENCY LIGHT LIFTING BY AFT LAV. SECURED EMERGENCY LIGHT.
- 30 Apr 2013
Motor, faulty
AFT FORWARD LAV INOP - LEVEL 1. DUE TO REPEAT GRIPES OF AFT FORWARD LAVATORY FLUSH MOTOR WEAK OR NEEDS SERVICE, PLEASE ACCOMPLISH MM 38-32-00,PG 501,TOILET…
- 21 Apr 2013
Cap, missing
EMERGENCY ESCAPE LIGHTING STRIP END CAP MISSING 40C. INSTALLED NEW END CAP.
- 16 Apr 2013
Cap, missing
EMERGENCY LIGHT END CAPS BELOW SEATS 1B, 8C, AND 12C ARE MISSING. REPLACED CAPS.
- 29 Mar 2013
Microphone, broken
COPILOTS BOOM MICROPHONE BROKEN OFF HEADSET. REPLACED BOOM MIC.
- 23 Mar 2013
Door, out of adjust
L2 DOOR HARD TO ARM. ADJUSTED DOOR LINER ALSO LOWER FOOTBALL CAMS AND LWR LINKAGE.
- 15 Mar 2013
Door, leaking
R1 DOOR HAS NOISE FROM PRESSURE LEAK AND VIBRATES. REPAIRED DOOR PRESSURE LEAK PER AMM, LEAK CHECKED OK.
- 12 Mar 2013
Girt Bar, dirty
L2 DOOR WILL NOT ARM. CLEANED AND LUBED GIRT BAR HARDWARE.
- 9 Mar 2013
Bear Strap, cracked
FOUND CRACK ALONG EDGE OF BEAR STRAP IAW NDT, PART 6, 53-10-17. PERFORMED REPAIR IAW EA53 30-04213 AND ECRA5331-01691.
- 9 Mar 2013
Bear Strap, cracked
FOUND CRACK INDICATION IN BEAR STRAP AREA FROM EDGE OF DOOR CUTOUT FWD GOING THROUGH RIVET LOCATION EXTENDING APPROXIMATELY 3 INCHES. VERIFIED CRACK FROM…
- 4 Mar 2013
Oven, smoke
BURNING ELECTRICAL ODOR EMANATING FROM GALLEY OVEN. REMOVED LINER, COULD NOT FIND CAUSE OF ODOR. REPLACED OVEN. OPS CHECKED GOOD.
- 24 Jan 2013
Controller, faulty
WINDOW EICAS MESSAGE DISPLAYED. POSITION 2. (1=L FWD, 2=L SIDE, 3=R FWD, 4=R SIDE) INOPERATIVE LIGHT ILLUMINATED INOPERATIVE LIGHT DID NOT EXTINGUISH WHEN…
- 22 Jan 2013
Starter, failed
DURING START ATTEMPT OF RT ENG, START VALVE OPENED, BUT NO N2 ROTATION. GROUND OBSERVER NOTICED SPARKS SHOOTING OUT OF COWLING. SUPPLEMENTAL DATA UPDATE,…
- 15 Oct 2012
Panel, unsecure
CEILING SAGGING NEAR ROW 39. PIECE FELL FROM OVERHEAD. SECURED OVERHEAD PANEL AFT LATCH WITH INTERM REPAIR, CEILING ACCESS PANEL BETWEEN ROWS.
- 28 Sep 2012
Floorbeam, cracked
FORWARD CARGO COMPARTMENT CABIN FLOORBEAM CRACKED BETWEEN WEB AND UPPER CHORD RADIUS, BS 700, AT LBL 24.75 AND LBL 45.5. MAJOR REPAIR ACCOMPLISHED: CUT OUT…
- 28 Sep 2012
Floorbeam, corroded
FLOORBEAM TOP CORRODED AT BS 365, RBL 2 TO RBL 65. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF T-CAP AND FABRICATED AND INSTALLED A NEW CHORD,…
- 28 Sep 2012
Stiffener, gouged
RIGHT WING LEADING EDGE, INBOARD FSS 231, SPAR STIFFENER IS GOUGED. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED THE STIFFENER PER SRM 51-40-2 AND BAC DWG…
- 28 Sep 2012
Skin, damaged
FUSELAGE EXTERNAL UPPER LEFT SIDE BELOW FORWARD EDGE OF US FLAG, BUTTON HEAD RIVET IS DAMAGED. FUSE SKIN DENTED AT BS 1580 AND BETWEEN S-9L TO S-10L DUE TO…
- 28 Sep 2012
Terminal Block, loose
J1 TERMINAL BLOCK IS LOOSE ON WINDOW. WINDSHIELD REQUIRES REPLACEMENT. ISSUE COA 507402 FOR REPLACEMENT. REPLACED WINDOW PER COA 507402, REF PTT SEQ #0422088.…
- 27 Sep 2012
Skin, damaged
REMOVED FASTENER AND FOUND HOLE TO BE KNIFE EDGE. TRIMMED OUT DAMAGED SKIN AND FABRICATED A REPAIR DOUBLER AND FILLER AND INSTALLED PER SRM 53-00-01, FIG 201,…
- 23 Sep 2012
Harness, frayed
R4 DOOR ESCAPE SLIDE HARNESS LOWER ATTACH POINT FRAYED. REMOVED AND REPLACED R4 DOOR ESCAPE SLIDE HARNESS.
- 23 Sep 2012
Harness, frayed
L1 DOOR SLIDE HARNESS STRAP FRAYED. REMOVED AND REPLACED L1 DOOR ESCAPE SLIDE HARNESS.
- 23 Sep 2012
Harness, frayed
R1 DOOR SLIDE HARNESS FRAYED. REMOVED AND REPLACED R1 DOOR SLIDE HARNESS IAW AMM.
- 23 Sep 2012
Harness, frayed
R2 DOOR SLIDE HARNESS AND STRAP FRAYED. REMOVED AND REPLACED R2 DOOR ESCAPE SLIDE HARNESS.
- 23 Sep 2012
Harness, frayed
L4 DOOR ESCAPE SLIDE HARNESS LOWER CTR ATTACH POINT FRAYED. REMOVED AND REPLACED L4 DOOR ESCAPE SLIDE HARNESS.
- 23 Sep 2012
Harness, frayed
R2 DOOR ESCAPE SLIDE HARNESS LOWER CTR ATTACH POINT FRAYED. REMOVED AND REPLACED R2 DOOR ESCAPE SLIDE HARNESS.
- 19 Sep 2012
Frame, corroded
FRAME AT BS 1661 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF T-CAP AND FABRICATED AND INSTALLED A NEW CHORD, REPAIR ANGLES AND STRAPS…
- 19 Sep 2012
Skin, damaged
THIS NON ROUTINE IS TO CAPTURE FABRICATION OF THE REPAIR DOUBLER AT BS 1393, BL 0, PER COA 50745 AND TASK CARD 59745401C, DUE TO THIS REPAIR CAN BE…
- 16 Aug 2012
Floorboard, damaged
SOFT SPOT IN FLOOR AT ROW 35 AISLE. FABRICATED NEW FLOORBOARD IAW DWG 146N5752. INSTALLED FLOORBOARD IAW MM.
- 5 Aug 2012
Wire, crimped
NR 1 AUDIO SELECTOR PANEL LIGHTING FAULTY (VOLUME CONTROL, ETC). (01=CAPT, 02=FO, 03=OBS). SUPPLEMENTAL DATA UPDATE, TROUBLESHOT SYSTEM. FOUND FAULTY CRIMP ON…
- 2 Aug 2012
Liner, damaged
NR 2 ENGINE FAN SOUND ABSORBING LINER HAS A HOLE IN IT AT THE 4 O'CLOCK POSITION IT IS .750 INCH BY .750 INCH, THE HOLE IS ALSO .825 INCH DEEP. SUPPLEMENTAL…
- 27 Jul 2012
Light, inoperative
SLIDE ARMED LIGHT AT 4R DOES NOT ILLUMINATE WITH SLIDE POSITIONED TO ARM. FOUND FWD GIRT BAR SLIDER DETACHED. REATTACHED FWD FOOT AND OPERATED SEVERAL TIMES.…
- 25 Jul 2012
Wire, unsecure
AIRCRAFT RETURN TO BLOCKS FOR FIRST OFFICERS PITOT EICAS AND LIGHT ON TAXI OUT. SECURED WIRE AT K10847 PIN A1.
- 21 Jul 2012
Hose, leaking
LEAK TEST FAILED. PER MM TOLERANCE IS 300 KTS (+-5 KTS), ACTUAL WAS 293.5 KTS, EXCEEDS LIMITS. FIRST OFFICERS PITOT LEAK WAS IN ELBOW AT ADC HOSE TO 'T'.…
- 9 Jun 2012
Girt Bar, disengaged
DOOR 4R ARMED WITH NO SLIDE LIGHT. FOUND FWD SIDE OF GIRT BAR NOT ENGAGED. SECURED GIRT SLIDERS AND ACCOMPLISHED, OPS CHECK PER MM 52-22-96. SLIDE OPS NORMAL.
- 1 Jun 2012
Connector, unsecure
EMERGENCY FLOOR LIGHTING NOT SECURE REAR OF AIRCRAFT. SECURED EMERGENCY PATH LIGHT CONNECTION AT FWD AFT LAV AT L4 DOOR AND SECURED PATH LIGHT COVER.…
- 29 Mar 2012
Heater, failed
RT AUX 1 PITOT FAILED PROBE HEAT TEST ON P61 PANEL-NO HEAT FROM PROBE NOTED. REPLACE PROBE.
- 29 Mar 2012
Arm, out of adjust
MAIN ENTRY DOOR IS OUT OF RIG. MADE INITIAL ADJUSTMENT TO GUIDE ARM. ALL 4 LATCH CAM FITTINGS SHOW SIGNS OF GOUGING. UPPER AFT LATCH ROLLER DAMAGED. FWD UPPER…
- 9 Mar 2012
Controller, faulty
WINDOW HEAT INOP LEFT SIDE WINDOW. SAMC TEXT: SWAPPED M191 & M192 FAULT FOLLOWED. RETURNED TO ORIGINAL POSN. NEEDS MR30415-194. REPLACED CURRENTLY INSTALLED…
- 24 Sep 2011
Slide, dislodged
DOOR 1R SLIDE PACK FELL DOWN WHEN DOOR WAS CLOSED. REINSTALLED SLIDE AND OPS CHECKED OPERATION. ALL CHECKED NORMAL.
- 1 Jul 2011
Mechanism, out of adjust
AFT RT MAIN ENTRY DOOR SLIDE ARMED INDICATOR LIGHT DOES NOT ILLUMINATE WITH SLIDE ARMED. ADJUSTED RIGHT AFT DOOR GIRT BAR MECHANISM PER AMM, OPS NORMAL.
- 13 Jun 2011
Slide, obstructed
THE 3R SLIDE DOES NOT SHOW ARMED WHEN ARMED. REMOVED LOOSE DEBRIES. SLIDE ARM AND DISARM OPERATION CHECKS OKAY.
- 25 Apr 2011
Cover, missing
EXPOSED WIRES BEHIND 6F. COSMETIC COVER MISSING AT END OF EMERGENCY LIGHT STRIP. SECURED WITH APPROVED TAPE. INSTALLED NEW COVER OVER END OF EMERGENCY LIGHT…
- 12 Apr 2011
Switch, faulty
EXTINGUISHER 1 BTL LT WILL STAY LIT WHEN TESTED. RPL NR 1 CARGO BTL DISCHARGE SWITCH, ACP TEST FROM BOTTLE TO SWITCH, TESTED GOOD PER MM. (PART# 563-3386)
- 23 Nov 2010
Girt Bar, malfunctioned
UNABLE TO DISARM DOOR 1R. GIRT BAR TO LOCKING FOOT. ALL PINS REMOVED, OPS CHECKED NORMAL. VERIFIED DR 1RT GIRT BAR ARMS PROPERLY.
- 1 Nov 2010
Ballast, faulty
FLT ATTENDANT REPORTED ODOR OF SMOKE IN AFT GALLEY ASSOCIATED WITH FLICKERING AFT GALLEY OVERHEAD LIGHTS. ODOR DISSIPATED WITH LIGHTS OFF AFT GALLEY.…
- 21 May 2010
Wire, cut
MID LAV EMERGENCY LIGHT STRIP INOPERATIVE. REPLACED EMERGENCY LIGHT STRIP MID LAV FOUND, EMERGENCY LIGHT STRIP CUT. SUSPECT THAT WIRING CUT DURING CARPET…
- 3 Jan 2010
Socket, dirty
4 RT MED EXTERIOR EMERGENCY EVACUATION LIGHT INOPERATIVE. CLEANED SOCKET, OPS GOOD.
- 3 Jan 2010
Restraint, corroded
DOOR 1 RT SLIDE PLATE GIRT RESTRAINT HAS EXFOLIATION CORROSION. REPLACED PLATE AND 2 EA SCREWS WHILE INSTALLING SLIDE.
- 24 Jul 2009
Unknown, odor
RTO AT APPROX 75 KTS, HOT OILY ODOR WITH AN ASSOCIATED ACRID SMOKE AND/OR CONDENSATION APPEARING TO COME FROM AREA OF FLIGHT DECK WINDOWS NR 1 AND NR 2 LT. NR…
- 2 Mar 2009
Sill, defective
DOOR 3L HAS LOUD AIR NOISE. INSTALL NEW DOOR SILL AT 3L. PICKED UP ALL THE HOLES IN MIDDLE SECTION OF DOOR SILL AND STILL NEED TO RIVET THREE BRACKETS AND…
- 2 Mar 2009
Bolt, improper part
DOOR 3L SLIDE HARD TO ENGAGE. FOUND GIRT BAR ENDS NOT FULLY ENGAGING IN FLOOR FITTINGS BECAUSE OF PLAY IN ARM NR 395 OF IPC 52-11-20-032. REMOVED SLIDE ASSY.…
- 2 Mar 2009
Bolt, improper part
DOOR 3L SLIDE HARD TO ENGAGE. FOUND GIRT BAR ENDS NOT FULLY ENGAGING IN FLOOR FITTINGS BECAUSE OF PLAY IN ARM NR 395 OF IPC 52-11-20-032. REMOVED SLIDE ASSY,…
- 2 Mar 2009
Sill, defective
DOOR 3L HAS LOUD AIR NOISE. INSTALL NEW DOOR SILL AT 3L. PICKED UP ALL THE HOLES IN MIDDLE SECTION OF DOOR SILL AND STILL NEED TO RIVET THREE BRACKETS AND…
- 2 Mar 2009
Washer, out of tolerance
DOOR 3L SLIDE HARD TO ENGAGE. FOUND GIRT BAR ENDS NOT FULLY ENGAGING IN FLOOR FITTINGS BECAUSE OF PLAY IN ARM 395 OF IPC 52-11-20-032. REMOVED SLIDE ASSY,…
- 13 Jul 2008
Lamp, inoperative
EMERGENCY LIGHT AT SEAT ROW 27DEF INOP. *S/D* LAMPS INOP AT ROW 27. RE-LAMPED ASSY AT ROW 27, OPS CHECKED GOOD.
- 19 Feb 2008
Door, out of adjust
DOOR 3R HAS ARMING PROBLEMS. DOOR OUT OF ADJUSTMENT. ADJUSTED DOOR. ARMS/DISARMS NORMALLY.
- 31 Jan 2008
Oxygen Mask, misinstalled
F-O OXYGEN MASK AND SPEAKER ARE INSTALLED IN REVERSE POSITIONS. FOUND TO BE INSTALLATION ERROR (QA). REINSTALLED OXYGEM BOX AND SPEAKER BOX IN CORRECT…
- 31 Jan 2008
Oxygen Mask, faulty
CREW REPORT: CAPT OXYGEN MASK MIC INOPERATIVE. FOUND ELECTRICAL SHORT IN WIRING IN CAPT O2 MASK MIC. REPLACED CAPT O2 MASK AND MIC ASSY. OPS CHECKED NORMAL.
- 27 Sep 2007
Engine, malfunctioned
PER CREW, ENG WOULDN'T SHUTDOWN, HAD TO CYCLE FUEL CUTOFF SWITCH SEVERAL TIMES TO GET ENG TO SHUT DOWN. ALSO HAD A LOT OF FUEL VAPOR COMING OUT OF TAILPIPE.…
- 15 Sep 2007
Apu, shutdown
APU SHUTDOWN WHILE AT GATE. 10-9-07 ACCOMPLISHED FADEC BITE TEST - LAST FIVE LEGS SHOW NO FAULTS. REPLACED OIL PRESS SWITCH. APU RUNS NORMAL WITH FULL…
- 9 Sep 2007
Wire Harness, damaged
RIGHT IDG TRIPPED AFTER ENG START, GEN SW RESET, NO HELP. 10-11-07 FOUND BURNED PINS AT FIREWALL CONNECTOR D1292.N PINS B AND C. REPLACED ENGINE POWER FEEDER…
- 24 Jun 2007
Light, inoperative
DOOR 1R SLIDE LIGHT SWITCH BROKEN. [07-27-07] REPLACED GIRT BAR SLIDE ARMED LIGHT ON R-1 DOORWAY LINING PANEL. OPS CHECK GOOD.
- 20 Jun 2007
Stringer, corroded
MAIN CABIN STRINGER 17L HAS CORROSION AT BS 1198. MAJOR REPAIR ACCOMPLISHED: REMOVED STRINGER AND FABRICATED & INSTALLED A NEW -3 CHORD.
- 18 Jun 2007
Cusp Web, corroded
CORROSION ON UPPER SURFACE OF RIGHT CUSP WEB, BS 996 TO 1020. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION. FABRICATED & INSTALLED NEW WEB.
- 18 Jun 2007
Shear Tie, corroded
AFT PIT SHEAR TIE CORRODED AT STA 1460, LBL 3. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FABRICATED & INSTALLED A NEW SHEAR TIE.
- 18 Jun 2007
Intercostal, damaged
AFT PIT AT STA 1360 INTERCOSTAL BETWEEN STR 27R TO 28R IS CORRODED ON BOTTOM. MAJOR REPAIR ACCOMPLISHED: AFTER FURTHER INVESTIGATION NO CORROSION FOUND ON…
- 18 Jun 2007
Intercostal, corroded
AFT PIT BETWEEN STA 1400 TO 1420, INTERCOSTAL BETWEEN STR 27L TO 28L IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED INTERCOSTAL. FABRICATED & INSTALLED A NEW…
- 18 Jun 2007
Intercostal, corroded
AFT PIT BETWEEN STA 1420-1440, INTERCOSTAL BETWEEN STR 28R TO 29R IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION. FABRICATED & INSTALLED NEW…
- 14 Jun 2007
Floorbeam, corroded
FLOORBEAM T-CAP CORRODED AT BS 1640. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA. FABRICATED & INSTALLED NEW T-CAP SECTION.
- 14 Jun 2007
Gate, corroded
R-1 DOOR UPPER GATE CORRODED. [08-07-07] REMOVED GATE ASSY FROM DOOR AND REMOVED HINGE FROM OLD GATE. REASSEMBLED HINGE ONTO NEW GATE, AND INSTALLED NEW GATE…
- 6 Jun 2007
Doubler, corroded
CABIN FLOOR SHEAR WEB DOUBLER AT RBL 50, BS 1680 HAS CORROSION ON UPPER SURFACE. [08-07-07] REMOVED CORROSION ONTHICKNESS 0.080, REMAINING 0.076 FOUND TO BE…
- 19 Apr 2007
Wedge, delaminated
INBD SLAT WEDGE DELAMINATED T/E WEDGE DELAMINATED. T/E WEDGE REPLACED WITH NEW.
- 21 Feb 2007
Door Frame, faulty
NR 2 LT MED FWD FRAME CRACKED AT UPPER HINGE CUTOUT. ALSO, EXTERNAL HANDLE DOES NOT STOW AND LATCH IN PAN AUTOMATICALLY. [SUP 4-17-07] MAJOR REPAIR…
- 20 Feb 2007
Hinge, cracked
NR 2 RT MED UPPER HINGE CUTOUT IS CRACKED ON DOOR FRAME. [SUP 4-17-07] REPAIRED DOOR 2R PER A BOEING APPROVED REPAIR SCHEME. BOEING AND UA ENGINEERING STILL…
- 9 Feb 2007
Floor Support, cracked
AFT PIT CENTER LINE FLOOR SUPPORT CHANNEL BETWEEN STA 1400 AND 1420 CRACKED. MAJOR REPAIR ACCOMPLISHED. STOP DRILLED CRACKS. APPLIED CORROSION INHIBITING…
- 7 Jan 2007
Pump, failed
RED OIL TEMP ON NR 2 ENGINE EICAS INDICATION. ACFT RETURNED TO BLOCKS. INSPECTED OIL TANK, FOUND OIL IN TANK BELOW LIP, DRAINED APPROX 2 GALLONS FROM GEARBOX.…
- 3 Sep 2005
Skin, damaged
NR 1 PYLON OB SKIN DAMAGED. REPAIRED PER SRM 54-31-99.
- 19 Sep 2004
Carbon Seal, failed
APU AUTO SHUT DOWN DUE TO LOSS OF OIL PRESSURE. SHOP FINDINGS REVEALED DRIVEN COMPRESSOR FRONT CARBON SEAL ASSEMBLY LEAKED. THE INTERNAL LIP SEAL WAS PINCHED…
- 31 Jul 2004
Duct, leaking
RETURN TO FIELD DUE TO SMOKE IN THE FLIGHT DECK. FOUND A LEAKAGE ON THE BLEED DUCT CLAMP OF THE NR 1 ENGINE INBOARD REVERSER HOLD OPEN ACTUATOR. THE ACTUATOR…
- 27 Feb 2004
Skin, lightning strike
FUSELAGE SKIN AT BS 1460 HAS LIGHTNING STRIKE ADJACENT TO A FASTENER HOLE, ALONG PRODUCTION BUTT SPLICE BETWEEN STRINGER 24L & 25L. MAJOR REPAIR ACCOMPLISHED.…
- 11 Feb 2003
Skin, damaged
SKIN DAMAGE BY JETWAY FORWARD OF DOOR 2L. MAJOR REPAIR ACCOMPLISHED. FUSELAGE SKIN REPLACED.
- 5 May 2002
Actuator, bypassing
GEAR UP DISAGREE LIGHT ILLUMINATED. NLG RETRACT ACTUATOR BYPASSING AND NOT RETRACTING GEAR. REPLACED NLG RETRACT ACTUATOR.
- 22 Aug 2001
Hose, kinked
#2 ENGINE MAIN HYDRAULIC SUPPLY LINE, FROM FIREWALL TO RIGID LINES FOUND TWISTED AND KINKED WITH APPROXIMATELY 3/4 TWIST AND COLLAPSED BENEATH SHIELDING.…
- 30 May 2001
Frame, corroded
FRAME CORRODED STA 1020 LBL 75, WL 208. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW T-CHORD REPAIR.
- 27 May 2001
Frame, damaged
FRAME DAMAGED IN AFT PIT STA 1260 RBL 25. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLERS AT UPPER FLANGE.
- 25 May 2001
Crease Beam, corroded
RT CREASE BEAM CORRODED, STA 1125. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW CREASE BEAM WEB.
- 25 May 2001
Frame, dented
FRAME DENTED STA 640 STR 18L.
- 25 May 2001
Frame, damaged
FRAME DAMAGED STA 1480, BETWEEN STR 26L AND 27L.
- 22 May 2001
Floorbeam, corroded
FLOORBEAM CORRODED STA 324, RBL 57. MAJOR REPAIR ACCOMPLISHED. INSTALLED SPLICE ANGLE REPAIR.
- 21 May 2001
Beam, corroded
CREASE BEAM WEB CORRODED STA 1160-1180 LEFT SIDE. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB.
- 20 May 2001
Floorbeam, corroded
CABIN FLOORBEAM CORRODED STA 1640 RBL 11-58. MAJOR REPAIR ACCOMPLISHED. INSTALLED CAP SPLICE.
- 19 May 2001
Crease Beam, corroded
CREASE BEAM CORRODED STA 965 LEFT SIDE. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM WEB.
- 19 May 2001
Crease Beam, corroded
CREASE BEAM WEB CORRODED STA 1160-1180 RIGHT SIDE. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB.
- 16 May 2001
Floorbeam, corroded
CABIN FLOORBEAM WEB CORRODED STA 1425, STR RBL 70. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW WEB.
- 15 Dec 2000
Lever, failed
AFTER TAKEOFF UNABLE TO RETRACT GEAR. *S/D* REPLACED LANDING GEAR CONTROL LEVER MODULE.
- 12 Dec 2000
Fitting, misinstalled
UPON GEAR EXTENSION, NOSE GEAR DOWNLOCK GREEN LIGHT NOT ILLUMINATED. EICAS MESSAGE, GEAR DISAGREE STATUS, NOSE GEAR DISAGREE GEAR MONITOR. *S/D* REMOVED 1/8…
- 3 Feb 1999
Tube, leaking
SLIDE FAILED AIR RETENTION TEST DURING SHOP VISIT. *S/D* POROSITY CAUSED SEAM LEAK. UNIT WAS SENT TO VENDOR FOR EVALUATION AND REPAIR.
- 15 Nov 1997
Slide, disconnected
NR 1 RT SLIDE ENGAGE LIGHT INOP. *S/D* RESECURED GIRT MECHANISM, OPS CHECKED NORMAL.
- 11 Apr 1997
Actuator, failed
ON APPROACH LEADING EDGE SLAT DISAGREE MESSAGE WITH AMBER LEADING EDGE LIGHT BETWEEN POSITION 1 AND 5 CAME ON. *S/D* LEADING EDGE SLAT ROTARY ACTUATOR FAILED.…
- 7 Oct 1996
Fuel Pump, failed
ON APPROACH, LEFT ENGINE FLAMED OUT. ENGINE SHUTDOWN. *S/D* IMPROPER LAPPING OF BEARINGS BY THE OEM CAUSED THE FUEL GEAR STAGE BEARINGS TO BIND WITH THE…
- 9 Jul 1996
Power Supply, inoperative
CEILING EMERGENCY EXIT LIGHT INOP AT SEAT 17ABC. CHANGED POWER SUPPLY ITEM, EMERGENCY LIGHTS OPERATION CHECKS NORMAL.
- 17 Apr 1995
Sensor, failed
LANDED UNDER AMBER ALERT, BECAUSE THE LEADING EDGE DEVICES WOULD NOT EXTEND. REPLACED THE NR 1 SLAT POSITION SENSOR. SYSTEM OP CHECKED OK.