- 5 Jul 1998
Battery Pack, discharged
NUMEROUS EMERGENCY EXI TAND FLOOR LEVEL LIGHTS INOPERATIVE. REMOVED AND REPLACED LIGHT BATTERY PACKS AT STATIONS 460 AND 1140. (M)
- 4 Feb 1998
Wire, failed
DURING SCHEDULED MAINTENANCE IN TUS, RIGHT AFT EMERGENCY EXIT LIGHT STAYS ON WITH POWER ON. REPAIRED WIRING TO TERMINAL LUG CONNECTION. (M)
- 15 Oct 1994
Switch, out of adjust
A/C AIR RETURN TO GATE BECAUSE E/E DOOR OPEN. OVERHEAD CAUTION LIGHT INOPERATIVE. FOUND DOOR WARNING SWITCH AT E/E DOOR OUT OF ADJUSTMENT, RIGGED DOOR SWITCH.…