- 16 Aug 2002
Panel, illuminated
DURING CRUISE, ENROUTE, THE NR1 ENGINE DRIVEN HYDRAULIC PUMP (A) SYSTEM LOW PRESSURE LIGHT ILLUMINATED. FIVE MINUTES LATER, THE NR 2 ENGINE DRIVEN HYDRAULIC…
- 30 Jul 2002
Light, failed
PILOT REPORTED THE EMERGENCY LIGHTS AT SEAT ROW 10ABC INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LIGHT ASSEMBLY. OPERATIONAL CHECK NORMAL.
- 19 Nov 2001
Battery Pack, discharged
TPA - MAINTENANCE FOUND THE LEFT OVERWING EMERGENCY LIGHT EXTINGUISHES AFTER A FEW SECONDS OF OPERATION. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK.…
- 24 Aug 2001
Hydraulic Line, cracked
DTW - FLT 1291 - ON CLIMB-OUT FROM DTW, EN ROUTE TO PHL, CAPTAIN REPORTED A FAILURE OF THE 'A' HYDRAULIC SYSTEM ALONG WITH HYDRAULIC QUANTITY LOSS. CAPTAIN…
- 21 Oct 2000
Light, failed
ROA-PIT - FLT 1295 - AFTER LANDING GEAR EXTENSION THE RIGHT MAIN GEAR DOWN LOCK LIGHT DID NOT ILLUMINATE. A VISUAL INSPECTI0N COULD NOT CONFIRM THE LANDING…
- 4 Apr 2000
Clamp, loose
CHS - FLT 1452 - ON CLIMB-OUT FROM RSW, AT FL270, CAPTAIN RECEIVED A RIGHT WING BODY OVERHEAT INDICATION. LIGHT EXTINGUISHED IMMEDIATELY AFTER BLEED SWITCH…
- 2 Mar 2000
Keelbeam, cracked
TPA - FOUND KEEL BEAM CRACKED, RBL 630 KEEL BEAM. INSTALLED DOUBLER PER SRM 53-60-12. (M)
- 3 Jun 1999
Light, inoperative
PHL - PILOT REPORTED THAT THE LOW LEVEL EMERGENCY LIGHTS IN THE AFT SECTION OF THE CABIN, AT ROWS 17-21 ABC, ARE INOPERATIVE. MAINTENANCE FOUND THE SEAT…
- 29 May 1999
Brackets, cracked
CLT - DURING Q4 CHECK, FOUND 1 INCH CRACK IN RADIUS OF VERTICAL FLANGES AT ATTACH CLIP/BRACKETS AT LBL 2 AND RBL 2 AT STATION 727D. DEFECTIVE PART REPLACED…
- 29 May 1999
Frame, cracked
CLT - DURNG Q-4 CHECK, FOUND .125 INCH CRACK IN FRAME AT STATION 400 BETWEEN STRINGER 8R - STRINGER 9R (O/HEAD BIN ATTACH). INSTALLED DOUBLER PER SRM 53-00-07…
- 29 May 1999
Floorbeam, corrosion
CLT - DURING Q-4 CHECK, FOUND 1.5 INCH BY .5 INCH CORRODED AREA ON FLOORBEAM AROUND FLOORBOARD HOLE AT BS 412 BL 0. CORROSION LEVEL 1. INSTALLED STRAP ON AFT…
- 29 May 1999
Angle, cracked
CLT - DURIGN Q-4 CHECK, FOUND 2 INCH CRACK (FASTENER HOLE TO HOLE) AT LOWER END OF BS 618 LEFT FRAME INNER CHORD ANGLE. DEFECTIVE PART REPLACED WITH IDENTICAL…
- 29 May 1999
Bracket, cracked
CLT - DURING Q-4 CHECK, FOUND .25 INCH CRACK AT ANTENNA BRACKET AT 727 D TO E. INSTALLED NEW PART, IDENTICAL NUMBER PER SRM 51-10-02. (M)
- 29 May 1999
Clip, cracked
CLT - DURING Q-4 CHECK, FOUND .125 INCH CRACK IN CLIP AT STATION 380, TOP CENTER CLIP (STRINGER TO FRAME ATTACH CLIP). DEFECTIVE PART REPLACED WITH IDENTICAL…
- 29 May 1999
Frame, cracked
CLT - DURING Q-4 CHECK, FOUND FUSELAGE FRAME CRACKED .200 INCH IN LENGTH, THREE (3) HOLES AT CLIP ATTACH ON FRAME. REMOVED DAMAGE AND INSTALLED DOUBLER PER…
- 29 May 1999
Frame, cracked
CLT - DURIGN Q-4 CHECK, FOUND .12 5INCH CRACK AT FRAME STATION 440 BETWEEN STRINGER 8L - STRINGER 9L (OVERHEAD BIN ATTACH). INSTALLED DOUBLER REPAIR PER SRM…
- 29 May 1999
Frame, cracked
CLT - DURING Q-4 CHECK, FOUND .125 INCH CRACK AT FRAME STATION 400 BETWEEN STRINGER 8L - STRINGER 9L (OVERHEAD BIN ATTACH). INSTALLED DOUBLER REPAIR PER SRM…
- 29 May 1999
Clip, cracked
CLT - DURING Q4 CHECK, FOUND 1 INCH CRACK IN RADIUS OF VERTICAL FLANGES AT ATTACH CLIP/BRACKETS AT LBL 2 AND RBL 2 AT STATION 727D. DEFECTIVE PART REPLACED…
- 29 May 1999
Floorbeam, corroded
CLT - DURING Q-4 CHECK, FOUND SEVERAL 1 INCH DRAIN CORRODED AREAS IN FLOORBEAM AT STATION 986.5 FROM LEFT CREASE BEAM TO RIGHT CREASE BEAM FLOOR LEVEL.…
- 29 May 1999
Mount, corroded
CLT - DURING Q-4 CHECK, FUOND 2 INCH DIAMETER CORRODED AREA IN FORWARD INBOARD LAV MOUNT AT STATION 993 RBL 19 FLOOR LEVEL. CORROSION LEVEL 1. CORROSION TASK…
- 29 May 1999
Beam, corroded
CLT - DURING Q4 CHECK, FOUND PREVIOUS BLEND OUT TOP OF T-CAP ON BEAM AT STATION 328 LBL 49, WL 208. INSTALLED REPAIR DOUBLERS AND SPLICE OT CAP PER SRM…
- 29 May 1999
Strap, corroded
CLT - DURING Q-4 CHECK, FOUND 2 INCH BY 14 INCH AREA OF CORROSION AT STRAP AT STATION 1016 TO 1038, WL 3 FLOOR LEVEL. CORROSION LEVEL 2, CORROSION TASK NR…
- 29 May 1999
T-Cap, corroded
CLT - DURING Q-4 CHECK, FOUND .5 INCH CORRODED AREA SEVERAL PLACES AT T-CAP AT BS 1016 LBL 28-33. CORROSION LEVEL 1. INSTALLED T-CAP REPAIR PER SRM 53-00-51…
- 29 May 1999
Mount, corroded
CLT - DURING Q4 CHECK, FOUND 2 INCH DIAMETER CORRODED AREA AT AFT OUTBOARD LAV MOUNT AT STATION 1012, RBL 37, FLOOR LEVEL. CORROSION LEVEL 1, CORROSION TASK…
- 29 May 1999
Angle, corroded
CLT - DURING Q-4 CHECK, FOUND 1 INCH BY 39 INCH CORRODED AREA AT Z-ANGLE AT STATION 947 TO 986. CORROSION LEVEL 1, CORROSION TASK NR C53-107-02. REPLACED…
- 29 May 1999
Angle, corroded
CLT - DURING Q-4 CHECK, FOUND 40 INCH CORROSION AT Z-ANGLE AT BS 947 TO 986. CORROSION LEVEL 1, CORROSION TASK NR C53-107-02. REPLACED Z-ANGLE PER SRM…
- 29 May 1999
Floor, corroded
CLT - DURING Q-4 CHECK, FOUND 3 INCH CORROSION AT LT LAV FLOOR PAN. CORROSION LEVEL 1, CORROSION TASK NR C53-107-02. NEW WEB INSTALLED PER SRM 51-10-02. (M)
- 29 May 1999
Bracket, cracked
CLT - DURING Q4 CHECK, FOUND 2 INCH CRACK IN LOWER FLANGE AT ANTENNA SADDLE BRACKET AT STATION 727E - 727D. REPLACED SADDLE BRACKET. (M)
- 29 May 1999
Keel Beam, corroded
CLT - DURING Q4 CHECK, FOUND .5 INCH BY 14 INCH CORRODED AREA AT RT KEEL BEAM AT BS 710 - BS 724, RBL 6.3, WL 148.5. CORROSION LEVEL 1, CORROSION TASK…
- 13 Oct 1998
Socket, failed
PIT - MAINTENANCE FOUND THE EMERGENCY FLOOR TRACK LIGHTING AT SEAT ROW 22 INOP. MAINTENANCE REMOVED AND REPLACED THE LIGHT SOCKET AT SEAT ROW 22 FLOOR TRACK…
- 13 Aug 1998
Light, inoperative
CLT - PILOT REPORTED THAT THE SEAT MOUNTED EMERGENCY EXIT LIGHT AT ROW 12 IS INOP. MAINTENANCE REMOVED AND REPLACED TWO LAMPHOLDER ASSEMBLIES AT SEAT ROW 12.…
- 18 May 1998
Light, inoperative
TPA - DURING B-CHECK, MAINTENANCE FOUND THE EXTERIOR EMERGENCY LIGHT AT THE AFT SERVICE DOOR INOP. MAINTENANCE FOUND THE LIGHT SOCKET WAS BROKEN DUE TO…
- 17 Dec 1997
Seal, failed
CLT - FLT 81 - SHORTLY AFTER LEVELING OFF AT FL330, AIRCRAFT EXPERIENCED A RAPID DECOMPRESSION. CREW DECLARED AND EMERGENCY, DESCENDED TO 10,000 FT AND…
- 20 Nov 1997
Wire Harness, failed
LAX - FLT 36 - AT DEPARTURE TIME, CREW REPORTED THAT ONE FLOOR LEVEL EMERGENCY LIGHT IN THE FORWARD CABIN WAS INOP. AIRCRAFT WAS RELEASED FOR CONTINUED…
- 10 Nov 1997
Adc, failed
PIT - FL 152 - SHORTLY AFTER TAKEOFF, THE AUTO-PILOT DISENGAGED, THE FIRST OFFICERS AIRSPEED DECREASED, THE STALL WARNING SOUNDED AND THE STICK SHAKER…
- 9 Nov 1997
Charger, inoperative
PHL - MAINTENANCE FOUND A STRIP OF EMERGENCY LIGHTS IN THE FORWARD CABIN INOP. MAINTENANCE REMOVED AND REPLACED THE BATTERY AND CHARGER ASSEMBLY. OPS CHECK…
- 9 Nov 1997
Battery, discharged
PHL - MAINTENANCE FOUND A STRIP OF EMERGENCY LIGHTS IN THE FORWARD CABIN INOP. MAINTENANCE REMOVED AND REPLACED THE BATTERY AND CHARGER ASSEMBLY. OPS CHECK…
- 12 Oct 1997
Wire, broken
CLT - FOUND FLOOR TRACK LIGHTING AT ROW 3 INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE. OPERATIONAL CHECK GOOD. (M)
- 7 Oct 1997
Wire, broken
ORD - FORWARD 4 EMERGENCY FLOOR LIGHTS INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE. OPERATIONAL CHECK GOOD. (M)
- 26 Sep 1997
Socket, failed
CLT - MAINTENANCE FOUND THE FLOOR TRACK EMERGENCY LIGHTING INOPERABLE AT ROWS 9 AND 18. MAINTENANCE REMOVED AND REPLACED THE LIGHT SOCKET (PN 08169-1) AT ROW…
- 9 Sep 1997
Battery Pack, failed
MIA - EMERGENCY EXIT LIGHTS ROW 18 (FLOOR) INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK OK. (X)
- 24 May 1997
O-Ring, failed
BWI - FLT 2399 - AT FL 210, THE NR 1 ENGINE A-SYSTEM HYDRAULIC LOW PRESSURE LIGHT ILLUMINATED. CAPTAIN SHUT DOWN THE NR 1 ENGINE HYDRAULIC PUMP AND MAINTAINED…
- 18 Jan 1996
Sensor, failed
FLT NR 7015 - PIT - AFTER EXTENSION, RED NOSE GEAR LIGHT FAILED TO EXTINGUISH. MAINTENANCE REPLACED THE NOSE GEAR LOCK SENSOR. INDICATIONS NORMAL. (M)
- 29 Aug 1995
Angle, corrosion
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH CORROSION AT CLIP NUT HOLES, AFT CARGO BIN AFT CENTER BULKHEAD LOWER ATTACH ANGLE. REPLACED…
- 29 Aug 1995
Floor Beam, corrosion
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 4 INCH CORROSION BS 947.5 TO BS 967 RBL 45 ON FLOOR BEAM T-CAP. FABRICATED NEW T-CAP 18 INCHES LONG,…
- 28 Aug 1995
Stringer, corrosion
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORROSION BS 870 S-21L. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-70-11 FIG 1.…
- 25 Aug 1995
Skin, chafed
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CROWN SKIN CHAFED UNDER DORSAL FIN CONTACT AREA, S-1 BS 887 TO BS 867. INSTALLED EXT SKIN DOUBLER. REPAIRED…
- 24 Aug 1995
Stringer, cracked
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK BS 500 PLUS 4 STRINGER 16L. INSTALLED DOUBLER, REPAIRED PER EO 5393X228. (M)
- 24 Aug 1995
Stringer, cracked
INT - DURING Q-3 CHECK VISUAL, FOUND .5 INCH CRACK BS 500 C PLUS 4 STRINGER 16R. INSTALLED DOUBLER, REPAIRED PER EO 539X228. (M)
- 24 Aug 1995
Stringer, cracked
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK BS 500 C PLUS 16, STRINGER 16R. INSTALLED DOUBLER, REPAIRED PER EO 5393X228. (M)
- 24 Aug 1995
Dump Shoot Base, corrosion
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 3 INCH BY 6 INCH CORRODED AREA AFT CARGO BS 986.50- BS 1006 DUMP SHOOT BASE. INSTALLED NEW BASE PER DRAWING…
- 23 Aug 1995
Skin, cracked
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 1 INCH CRACK IN FUSELAGE SKIN BS 925. INSTALLED EXT FUSELAGE SKIN REPAIR. REPAIRED PER SRM 53-00-01 FIG 202. (M)