N509JB
2000 Airbus Industrie A320-232 standard FAA →
registration
- 2000
NTSB
- 21 Jan 2001
incident, Jamaica NY
service difficulty reports
79 reports
- 21 Feb 2026
Seal, leaking
FLT # 1044 PBI-PBI. CABIN PRESS CAUTION/WARNING CABIN CLIMBED TO 9800FT @ FLT270.;PERFORMED TSM TASK 21-31-00-810-809. PERFORMED GVI OF A/C NO DEFECTS NOTED.…
- 3 Sep 2025
Skin, corroded
DURING HEAVY MAINTENANCE: CORROSION ON TOP SKIN, TRAILING EDGE OVERHANG, LOWER SURFACE, BTW WX40 13 & WX4349 ( BTW RIB 8 AND 9) ON LT WING; REFERENCE SAL WO…
- 3 Sep 2025
Skin, corroded
DURING HEAVY MAINTENANCE: CORROSION ON TOP SKIN, TRAILING EDGE OVERHANG, LOWER SURFACE, BTW WX4013 AND WX4349 ( BTW RIB 8 7 RIB 9 ), ON RH WING; REFERENCE…
- 29 Mar 2025
Slat, damaged
FLT#891, BOS-TPA.' BIRD STRIKE R WING LEADING EDGE OUTBOARD OF ENGINE; REMOVED AND REPLACED RH SLAT #2 REFERENCE AMM 27-84-64. OPS CHECK GOOD AT THIS TIME…
- 5 Aug 2024
Floorbeam, corroded
DURING HEAVY MAINTENANCE: "PASSENGER CABIN, UPPER SURFACE FLOOR BEAM STRUCTURE, FR 16, BTW 'Y' - 254 AND 'Y' 254, WITH CORROSIONS (3); "RAIL DUMMY PN:…
- 5 Aug 2024
Floorbeam, corroded
DURING HEAVY MAINTENANCE: "PASSENGER CABIN, UPPER SURFACE FLOOR BEAM STRUCTURE, FR 16, BTW 'Y' - 254 AND 'Y' 254, WITH CORROSIONS (3); RAIL DUMMY PN:…
- 5 Aug 2024
Floor Support, corroded
DURING HEAVY MAINTENANCE: CORROSION ON FLOOR STRUCTURE BTW 1732 AND FR-20; "FUSELAGE FLOOR STRUCTURE, WEB AT Y 1732 BETWEEN FR 20/FR 24 WAS REPLACED I.A.W.…
- 5 Aug 2024
Floor Support, corroded
DURING HEAVY MAINTENANCE: PASSENGER CABIN, UPPER SURFACE FLOOR BEAM STRUCTURE, BTW FR 16 AND FR 18, 'Y' - 254, WITH CORROSION; PASSENGER CABIN, UPPER SURFACE…
- 5 Aug 2024
Light, no test
DURING HEAVY MAINTENANCE: EMERGENCY LIGHT OPERATIONAL TEST NOT SATISFACTORY IN R2 EMERGENCY ESCAPE SLIDE RAFT P/N D30665-709 S/N M19328; ESCAPE SLIDE/RAFT AFT…
- 5 Aug 2024
Light, no test
DURING HEAVY MAINTENANCE: EMERGENCY LIGHT OPERATIONAL TEST NOT SATISFACTORY IN L1 EMERGENCY ESCAPE SLIDE; ESCAPE SLID/RAFT FWD DOOR LH WAS REPLACED IAW AMM…
- 5 Aug 2024
Light, no test
DURING HEAVY MAINTENANCE: EMERGENCY LIGHTS OPERATIONAL TEST NOT SATISFACTORY IN L2 EMERGENCY ESCAPE SLIDE; ESCAPE SLIDE /RAFT AFT DOOR LH WAS REPLACED IAW AMM…
- 5 Aug 2024
Hinge Arm, damaged
DURING HEAVY MAINTENANCE: REMOVAL OF VERTICAL STAB ARM OF HINGES FROM #1 THRU #7 TO PERFORM INSPECTION; REF AMERICANA WO# 131-2003 S/N 00579 FOR WORK…
- 5 Aug 2024
Skin, punctured
DURING HEAVY MAINTENANCE: UPPER FUSELAGE, ON FR80 BETWEEN STGR 2RH AND STGR 3RH WITH A PUNCTURE; UPPER FUSELAGE, ON FR80 BETWEEN STGR 2RH AND STGR 3RH…
- 5 Aug 2024
Skin, corroded
DURING HEAVY MAINTENANCE: RH WING UPPER SURFACE SKIN, WITH CORROSION NEXT TO PREVIOUS DOBLER REPAIR, BETWEEN RIBS 14, 15 AND REAR SPAR; CORROSION DAMAGE ON RH…
- 5 Aug 2024
Floor Support, corroded
DURING HEAVY MAINTENANCE: PASSENGER CABIN, UPPER SURFACE FLOOR BEAM STRUCTURE, BTW FR 18 TO FR 20, 'Y' -1292 WITH CORROSION; UPPER SURFACE FLOOR BEAM…
- 5 Aug 2024
Floorbeam, corroded
DURING HEAVY MAINTENANCE: PASSENGER CABIN, UPPER SURFACE FLOOR BEAM STRUCTURE, FR 16, BTW 'Y' 254 AND 'Y' 765, WITH CORROSION; (RESOLVED ON W/O: 1282422…
- 10 Dec 2023
None, none
DURING HEAVY MAINTEANACE: AIRCRAFT REQUIRES MOD AND WEEKLY WO# 1266397 AND 1293881. ENCOMPASSED WITHIN CAS WO# 509-1266397; RETURN TO SERVICE IN ACCORDANCE…
- 28 Aug 2023
Terminal, failed
FLT#268, PUJ-JFK. 'ELECTRICAL BURNING SMELL EMENATING FROM OVERHEAD FWD GALLEY LIGHT FIXTURE (S) TURNED LIGHTS OFF SMELL DISAPATED ( THALES-AVANT IFE (ENTIRE…
- 29 Apr 2023
Unknown, unknown
FLT#6, PTP-JFK. 'SIGNIFICANT ODOR IN CABIN DURING FINAL APPROACH REPORTED BY INFLIGHT; ACCOMPLISH WITH INFORMATION NOTICE 2017-T015, SECTION A, ISOLATED FAULT…
- 9 Apr 2023
Ptu, failed
FLT#1270, CHS-LGA. (AIRCRAFT DIVERTED TO JFK) 'Y HYD RSVR LO LVL; FOUND PTU MANIFOLD TO BE AT CAUSE FOR THE LEAK. REMOVED AND REPLACED PTU MANIFOLD IAW AMM…
- 29 Apr 2022
None, none
FLT#1677, JFK-JAX. 'PACK 1 PLACED ON MEL DUE TO ODOR EVENT ( PACKS ); REF WO #1176652 PERFORMED PACK 1 AND 2 BURNED REF AMM 21-00-00-615-802A. NO ODOR WAS…
- 18 Feb 2022
None, failed
FLT # 2092, MIA-JFK. A/C FLYING UNCOORDINATED IN CRUISE ON APPROACH RUDDER TRIM WAS TRIMMING IN THE OPPOSITE DIRECTION AND CREATED A SIGNIFICANT MISS TRIM AT…
- 11 Apr 2021
Floorbeam, corroded
DURING HMV, CORROSION FLOOR BEAM + Y765 LOCATED BTW FR18 & FR19 AT FORWRD GALLEY AREA; REF AEROMAN NR 2021-113244 -REMOVED & REPLACED FLOOR BEAM +Y765 LOCATED…
- 11 Apr 2021
Skin, corroded
DURING HMV, RER AEROMAN NR 2021-113286 CORROSION UPPER SURFACE OF UPPER SKIN CENTER WING BOX AT LEVEL FR41 AND FR42 BTW Y1292 AND Y1732 IN PASSENGER CABIN;…
- 11 Apr 2021
Support, corroded
DURING HMV, COROSION LOWER SILL LOC. FR66 & FR68 STR 23R AFT GALLEY AREA ; "REF AEROMAN NR W/O# 2021-116/1 WCC# 2021-113261 REMOVED AND REPLACED LOWER SILL…
- 11 Apr 2021
Floor Support, corroded
DURING HMV, CORROSION FLOOR BEAM + Y765 LOCATED BTW FR18 & FR19 AT FORWRD GALLEY AREA ;REF AEROMAN NR 2021-113244 -REMOVED & REPLACED FLOOR BEAM +Y765 LOCATED…
- 11 Apr 2021
Skin, corroded
DURING HMV, CORROSION UPPER SURFACE OF UPPER SKIN CENTER WING BOX AT LEVEL FRAME 41 AND FR 42 BTW Y1292 AND Y1732 IN PASSENGER CABIN CPCP RELATED 571157-01 ;…
- 11 Apr 2021
Power Supply, faulted
DURING HMV, FAULT MESSAGE EPSU UNIT EMER L FIN 11WL; REF AEROMAN NR 2021-113451 WO 2021 115/1 REMOVED AND REPLACED EPSU FIN POSITION 11WL I.A.W A.M.M.…
- 11 Apr 2021
Skin, corroded
DURING HMV, CORROSION UPPER SURFACE BTW RIB6 TO RIB7 AT LEVEL STR1 AND STR2 LEADING EDGE ON LH WING ; REF AEROMAN NR REMOVED CORROSION ON UPPER SURFACE BTW…
- 11 Apr 2021
Epsu, failed insp
DURING HMV, FAULT MESSAGE EPSU UNIT AFT L 13WL ; REF AEROMAN NR 2021-113115 WO 2021 116/1 REMOVED AND REPLACED EPSU FIN POSITION 13WL ASPER AMM…
- 11 Apr 2021
Ball Lock, out of alignment
DURING HMV, MISALIGNED SLIDE WING 193AT FLUSH BALL LOCK ; REF AEROMAN NR 2021-113247 WO 2021-116/1 R & R SLIDE WING 193AT IAW AMM 25-63-42-000-001-A
- 11 Apr 2021
Skin, corroded
DURING HMV, EA A21-330-01 WINGS / CENTER WING BOX / UPPER SKIN PANEL / UPPER SURFACE / Y1468 & STIFF 16-17 / CORROSION DAMAGE - PERMANENT REPAIR (THIS IS…
- 3 Jun 2020
Epsu, faulted
FLT 284, MCO-JFK. EPSU EXTERNAL LOAD FAULT/INTERNAL LOAD FAULT DURING OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM. PERFORMED TROUBLE SHOOTING IAW TSM…
- 3 Jun 2020
Epsu, faulty
FLT 284, MCO-JFK. EPSU EXTERNAL LOAD FAULT/INTERNAL LOAD FAULT DURING OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM. PERFORMED TROUBLE SHOOTING IAW TSM…
- 18 Jan 2020
Epsu, failed
AS PER T/C: A320-33-51-00710-003 FOUND EPSU AND BATTERY EMERGENCY LIGHT TO BE AT FAULT AT LOCATION 13WL; R & R EPSU AND BATTERY EMERGENCY LIGHT IAW AMM…
- 18 Jan 2020
Battery, failed
AS PER T/C: A320-33-51-00710-003 FOUND EPSU AND BATTERY EMERGENCY LIGHT TO BE AT FAULT AT LOCATION 13WL; R & R EPSU AND BATTERY EMERGENCY LIGHT IAW AMM…
- 27 Oct 2019
Wire Harness, damaged
FT # 2922, PBI-BOS. LAST ROW LEFT HAND ESCAPE PATH LIGHT INOP. ( FLOOR PROX EMERG ESCAPE PATH MARK SYS - INCANDESCENT LIGHTING SYS - NOT APPLICABLE TO (N703…
- 22 Aug 2019
Wire Harness, inoperative
9ABC SEAT EMERGENCY PATH LIGHTING INOP. R & R 19 ABC PATH WHITE LIGHT HARNESS 7261VCA. OPS CHECKED GOOD IAW WMM 33-51-08.
- 4 Apr 2019
Battery Pack, no test
FT # 391, EMERGENCY LIGHT TEST FAILED EPSU BATTERY 11WL; REMOVED AND REPLACED EPSU BATTERY AT FIN 11WL IAW AMM 33-51-38.
- 4 Apr 2019
Power Supply, failed
FT # 391, 3 ROWS OF LOW LEVEL LIGHTING INOP; REMOVED AND REPLACED AFT EPSU (13WL) IAE AMM 33-51-38. OPS CKD GOOD
- 4 Apr 2019
Slide, failed
FT # 391, DURING EMERGENCY LIGHT BITE AFT EPSU FAULT LIGHT FLASHING; T/S TO R2 SLIDE (POSSIBLE INTERNAL LIGHT SHORT). REMOVED AND REPLACED R2 DOOR SLIDE IAW…
- 12 Mar 2019
Battery, failed
FLT 391, BOS-TPA. EPSU BATTERY 10WL FAILS EMERG. LIGHT SYSTEM TEST; R & R BATTERY AT EPSU 10WL IAW AMM 33-51-38 SYSTEM CHECKS OK.
- 12 Mar 2019
Fan, failed
FLT 1992, TPA-BOS. FL 330 VENT EXTRACT FAULT LOUD BUZZ FOLLOWED BY SLIGHT ELECTRICAL BURNING SMELL AVIONICS VENT EXTR CIRCUIT BREAKER POPPED (EXTRACT FAN - NO…
- 3 Dec 2018
Floor Support, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y1162 LOCATED BTW FR 68 TO FR 70 AT AFT GALLEY AREA; REF BP NR # 2018-395184 REPLACED FLOOR…
- 3 Dec 2018
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON EXTERNAL SKIN LOCATED BTWN RIB 8-9 UPPER SURFACE ON LH WING; PERFORMED PERMANENT REPAIR LOC EXTERNAL…
- 3 Dec 2018
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON EXTERNAL SKIN LOCATED UPPER SURFACE AT LEVEL RIB 7 ON LH WING; PERFORMED PERMANENT REPAIR LOC EXTERNAL…
- 3 Dec 2018
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON EXTERNAL SKIN LOCATED UPPER SURFACE BTWN RIB1-2 ON LH WING; PERFORMED PERMANENT REPAIR LOC EXTERNAL SKIN…
- 3 Dec 2018
Skin, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON EXTERNAL SKIN LOCATED UPPER SURFACE BTWN RIB 4-5 ON LH WING; PERFORMED PERMANENT REPAIR LOC EXTERNAL…
- 7 Feb 2018
Battery, failed
FLT 225, JFK-TPA. EMERGENCY LIGHT BATTERY 11WL FAILED CAP TEST. R & R BATTERY IAW AMM 33-51-01, OPS CKS OK.
- 7 Feb 2018
Battery, failed
FLT 225, JFK-TPA. EMERGENCY LIGHT BATTERY 12WL FAILED CAP TEST. R & R BATTERY IAW AMM 33-51-01, OPS CKS OK.
- 2 Feb 2017
Power Supply, failed
DURING MAINTENANCE, AN EMERGENCY LIGHTS TEST WAS CONDUCTED AND VARIOUS LIGHTS FAILED TO ILLUMINATE. R & R EPSU 10WL IAW AMM 33-51-38-000-001-A, AND…
- 6 Jan 2017
Battery Pack, inoperative
ALL CABIN EMERGENCY LIGHTS WILL NOT ILLUMINATE WHEN POWER IS LOST. R & R THE BATTERY PACKS. .OPS CHECK PASSED IAW AMM 33-51-38.
- 6 Jan 2017
Battery Pack, inoperative
ALL CABIN EMERGENCY LIGHTS WILL NOT ILLUMINATE WHEN POWER IS LOST. R & R THE BATTERY PACKS. OPS CHECK PASSED IAW AMM 33-51-38.
- 6 Jan 2017
Battery Pack, inoperative
ALL CABIN EMERGENCY LIGHTS WILL NOT ILLUMINATE WHEN POWER IS LOST. R & R THE BATTERY PACKS. OPS CHECK PASSED IAW AMM 33-51-38.
- 6 Jan 2017
Battery Pack, inoperative
ALL CABIN EMERGENCY LIGHTS WILL NOT ILLUMINATE WHEN POWER IS LOST. R & R THE BATTERY PACKS. OPS CHECK PASSED IAW AMM 33-51-38.
- 6 Jun 2015
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND FLOOR SUPPORT Y1293, CORRODED FRAME 68. REPLACED FLOORBEAM IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE, FOUND FLOOR SUPPORT Y1293 CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE, FOUND FLOOR SUPPORT Y1293 CORRODED. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE, FOUND FLOOR SUPPORT Y765 CORRODED FROM FRAMES 66 TO 68. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE, FOUND FLOOR SUPPORT Y54 FRAMES 65 TO 66 CORRODED. REPLACED FLOORBEAM IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE FOUND FLOOR SUPPORT Y765, FRAMES 66 TO 68 CORRODED REPLACED FLOOR SUPPORT IAW SRM 51-42-11.
- 6 Jun 2015
Seat Track, corroded
DURING HEAVY MAINTENANCE FOUND Y1292, AFT FRAME 64 SEAT TRACK CORRODED. REPLACED THE SEAT TRACK IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE FOUND FLOOR SUPPORT Y1292, FRAMES 67 TO 69 CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE, FOUND CABIN FWD WET AREA CORROSION ON FLOOR SUPPORT Y254 FWD OF FRAME 14. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.
- 6 Jun 2015
Floor Support, corroded
DURING HEAVY MAINTENANCE, FOUND FLOOR SUPPORT Y1732 FWD FRAME 66 CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.
- 23 Mar 2015
Deu, malfunctioned
ON MAINTENANCE CHECK FOUND EMERGENCY LIGHTS FAIL THE TEST. EPSU COM EMERGENCY "L" IS DISPLAYED. R & R DEU 300RH4-B IAW AMM 23-73-47-000-001 AND…
- 11 Oct 2011
Light, defective
FLT 527 EWR-MCO, FWD CENTER OVERHEAD EMERGENCY LIGHT SIGN DIM. RELAMP SIGN IAW AMM 33-51-16. OPS CHECK GOOD.
- 21 Apr 2011
Power Supply, failed
ON GROUND MX CHECK - LT EPSU TEST FAILED. R & R LT EPSU IAW AMM 33-51-38. OPS CHECK NORMAL.
- 16 Apr 2010
Eec, failed
FLT 1622 LGB-LGB ENG 2 COMPRESSOR ECAM FIRST CAME ON WITHIN ONE MINUTE OF T/O WITH THRUST REDUCTION (DISAPPEARED QUICKLY) CONTINUED TO RE-APPEAR WITH EA…
- 29 May 2009
Proximity Sensor, failed
FLT 916, ORD-JFK, LPG GEAR DISAGREE, GEAR UNLOCK ECAM, WHEN LANDING GEAR WAS LOWERED THE LEFT MAIN DOWN AND LOCK INDICATION WAS IN DISAGREEMENT. ECAM WHEEL…
- 31 Oct 2008
Control Handle, failed
FLIGHT 908, ORD-JFK, RETURN TO ORD, LANDING GEAR HANDLE WILL NOT MOVE. HANDLE LOCKED IN DOWN POSITION AFTER TAKEOFF. REMOVED AND REPLACED LANDING GEAR LEVER…
- 2 Oct 2005
Outflow Valve, failed
VENT SKIN VALVE FAULT ON T/O ROLL, ABOUT 60 KTS. REMOVED AND REPLACED SKIN AIR OUTLET VALVE IAW AMM 21-26-53. OPS OK.
- 16 Jan 2005
Odor, detected
CABIN CREW REPORTED BURNING RUBBER ODOR IN CRUISE OF FLT. ODOR BARELY DETECTABLE. INSPECTED THE AIRCRAFT CABIN IAW (ATA 23-39)LIVE TV SYSTEM INTEGRITY CHECK…
- 6 Apr 2004
Acm, seized
AFTER TAKE OFF AT LGB, ON CLIMB SMELL AND VISIBLE INDICATION OF SMOKE IN CABIN PASSING THRU 10K/FT. AIR TURN BACK TO LGB. FOUND LT NR 1 PACK AIR CYCLE MACHINE…
- 26 Feb 2002
Slide, unserviceable
R2 DOOR EMERGENCY SLIDE INDICATED LOW PRESSURE. REMOVED AND REPLACED R2 DOOR SLIDE IAW AMM CHAP 25-62-44.
- 26 Feb 2002
Lamp, inoperative
EMERGENCY LIGHT AT SEAT 14C INOPERATIVE. ITEM ON MEL 33-50-03 AS PART IS NIS.
- 8 May 2001
Oxygen Bottle, discharged
IN FLIGHT, FLT NR 20, TPA TO JFK, F/A'S ADMINISTERED OXYGEN TO PAX FROM POB IN AFT GALLEY. FWD A/C RIGHT POB WOULD NOT FLOW WHEN ATTEMPT WAS MADE TO USE IT,…
- 23 Jan 2001
Sensor, malfunctioned
FLT 14 - JFK-FLL - EN ROUTE, THE LGCIU NR 1 FAULTED. AT GEAR EXTENSION CREW OBSERVED XX''S ON GEAR IND WITH TRIANGLE GREEN ON SECONDARY IND. MX CONTROL WAS…
- 17 Sep 2000
Light, inoperative
AT JFK, DURING DAILY CHECK, EMERGENCY LIGHTS FAILED SYSTEM TEST WITH MESSAGE, EPSU EXT LOAD AFT LEFT DISPLAYED. T/S SYSTEM PER TASK 33-51-00810-0808, CHECK…