N477DA
2007 Cirrus Design Corp SR20 standard FAA →
registration
- 2007
earlier registrations
1 past record
service difficulty reports
28 reports
- 19 Mar 2012
Magneto, malfunctioned
MAGNETO MISFIRES DURING MAGNETO CHECK.
- 20 Mar 1999
Skin, cracked
LFEC INSPECTION OF THE STRINGER 4R SKIN LAP SPLICE BETWEEN FS 481 AND 681 INDICATED CRACKS IN THE LOWER FASTENER ROW OF THE LOWER SKIN PANEL. INTERNAL HFEC…
- 20 Mar 1999
Skin, cracked
LFEC INSPECTION OF THE STRINGER 4R SKIN LAP SPLICE BETWEEN FS 680 AND 740 INDICATED CRACKS IN THE LOWER FASTENER ROW OF THE LOWER SKIN PANEL. INTERNAL HFEC…
- 20 Mar 1999
Skin, cracked
LFEC INSPECTION OF THE STRINGER 4R SKIN LAP SPLICE BETWEEN FS 360 AND 481 INDICATED CRACKS IN THE LOWER FASTENER ROW OF THE LOWER SKIN. INTERNAL HFEC…
- 1 Mar 1999
Battery Pack, discharged
EXTERIOR EMERGENCY LIGHT R/S BETWEEN OVERWING EMERGENCY EXITS INOP. REPLACED BATTERY PACK, OPS CHECK GOOD.
- 3 Oct 1998
Pump, failed
ON DESCENT, HYD QUANTITY SYSTEM 'B' WENT TO .3 GALLONS AND SLOWLY CONTINUED DOWN. RAN SYSTEM 'B' FLUID LOSS INOP CHECKLIST. FOUND NR 2 'B' SYSTEM PUMP…
- 24 Sep 1998
Panel, delaminated
FOUND ON A1 LETTER CK, NR 1 SPOILER PANEL DELAMINATED. REPAIRED PER SRM 57-50-6.
- 12 May 1998
Light, inoperative
MAIN ENTRANCE EMERG EXIT LIGHTS INOP DURING EMERG LIGHT TEST. REPLACED LIGHT ASSY.
- 7 Mar 1998
Control Rack, inoperative
ON LAYOVER CK, FOUND R2 EMERGENCY OVHD LT INOP. FOUND LIGHT CONTROL RACK BAD. REPLACED SAME, INSTALLED NEW BATTERY.
- 5 Mar 1998
Skin, cracked
THE R1 DOOR SURROUND BEAR STRAP WAS FOUND CRACKED AT THE UPPER HINGE CUTOUT. THE SKIN AND BEAR STRAP WERE BOTH TRIMMED TO REMOVE THE CRACK. A REPAIR DOUBLER…
- 4 Mar 1998
Fitting, cracked
FOUND AT F2 LETTER CHECK, RT ELEVATOR HINGE SUPPORT FITTING CRACKED BETWEEN NR 2 AND NR 3 BALANCE PANELS STA 99.79. REPAIRED PER M/M 55-10-31 AND ERA 364184-14.
- 15 Jul 1997
Vert Stab, cracked
AT MV2 FOUND STA 1303 CRACK, BULKHEAD, STA 1303 IN THE VERTICAL STAB, BOTH SIDES ARE CRACKED ON WEB. STOP DRILLED CRACKS AND FABRICATED DOUBLERS PER SRM…
- 16 Jun 1997
Skin, damaged
LEADING EDGE SLAT DENTED 48 INBOARD OF OUTBOARD END. ALSO, 3, 4, 10 RIBS CRACKED. REPAIRED PER SRM 57-54-0.
- 28 Jan 1997
Bulb, failed
EMERGENCY TRACK LIGHT AT 12D-23D-26D INOPERABLE. REPLACED BULBS - OPS CHECKS OK.
- 25 Nov 1996
Window, shattered
AT FL 310 R2 WINDOW OUTER PANE CRACKED. DIVERTED TO MCO.
- 25 Aug 1996
Skin, cracked
ER/A 222419-14 PROVIDED FOR A TEMPORARY AND PERMANENT REPAIR FOR DAMAGE TO THE UPPER SKIN PANEL OF THE LAP JOINT AT FS 505 AND STRINGER 26R. DURING THE…
- 17 May 1996
Skin, corrosion
CORROSION WAS FOUND IN THE SKIN AT FS 496 AND S-27R. THE CUTOUT FOR THE CORROSION MEASURED 1.25 IB/OB AND 2.75 FORE/AFT. IN ADDITION, AN INTERNAL REPAIR…
- 17 May 1996
Skin, corrosion
CORROSION WAS FOUND IN THE SKIN AT FS 496 AND S-27R. REPAIRED PER ER/A 303236-14.
- 26 Feb 1996
Rib, cracked
DURING INSPECTION, NR 3 L/E SLAT WAS FOUND WITH CRACKED RIB AT THE ANTI-ICE T-DUCT. REPAIRED PER MM 57-54-0.
- 26 Feb 1996
Rib, cracked
DURING INSPECTION, NR 3 L/E SLAT WAS FOUND WITH CRACKED RIB JUST O/B OF THE ACTUATOR ATTACH FITTING. REPAIRED PER MM 57-54-0.
- 16 Dec 1995
Eel Power Supply, inoperative
AFT SECTION OF EMERGENCY ESCAPE PATH LIGHT INOP. REPLACED BATTERY POWER SUPPLY, OPS CHECKS NORMAL. S/N ON 0483.
- 16 Dec 1995
Eel, broken
EMERGENCY EXIT LIGHT AT GALLEY SERVICE DOOR IS BROKEN (LEFT). REPLACED LIGHT ASSY, OPS CHECKS NORMAL.
- 23 Oct 1995
Battery Pack, discharged
CENTER AISLE OVERHEAD EMERGENCY LIGHT INOP AT ROW 26. REPLACED BATTERY PACK, OPERATION NORMAL.
- 18 Oct 1995
Angle, cracked
BULKHEAD ATTACH ANGLE CRACKED AT STR 10 LT SIDE FIN STA 180.600, INSIDE VERT STAB CRAWLWAY. FOUND AT D-2 LTR CK AND REPAIRED PER MM 55-30-0.
- 1 Jun 1995
Skin, dented
DURING SHOP INSPECTION OF THE RT O/B AILERON, FOUND NR 0244, LOWER I/B SKIN BENT AND OVERSIZED HOLES. REPAIRED PER SRM 57-51-0. NR 9588, TOP SKIN HAS NUMEROUS…
- 5 Apr 1995
Actuator Support, cracked
ACTUATOR SUPPORT BOX CRACKED I/B AND O/B SIDES AT NR 1 L/E FLAP. FOUND AT D-1 LTR CK. REPAIRED PER MM 57-20-21 PG 811.
- 5 Apr 1995
Actuator Angle, cracked
THE NR 13 SPOILER OUTBD ACT ATTACH ANGLE CRACKED. FOUND AT D-1 LTR CK. INSTALLED TIME LIMITED REPAIR PER SRM 57-50-6 PG 57 TO 60.
- 5 Apr 1995
Rib, cracked
FOUND DURING D-1 LETTER CHECK, NR 5 O/B RIB FOR ACTUATOR ROD END CRACKED. REPAIRED PER MM 57-54-0 PG 3, FOR RT WING NR 5 L/E SLAT.