N475DA
2007 Cirrus Design Corp SR20 standard FAA →
registration
- 2007
earlier registrations
1 past record
NTSB
- 5 Jun 2008
incident, Sanford FL
service difficulty reports
23 reports
- 27 Sep 1998
Battery Pack, discharged
LT OVERWING EXIT DOOR(S), EMERGENCY LIGHTS INOP. REPLACED LT OVERWING EXIT DOOR(S) BATTERY PACK, SYSTEM OPS. NORMAL PER MM.
- 26 Aug 1998
Battery Pack, discharged
FOUND LEFT OVERWING EMERGENCY EXIT LIGHT FWD POS INOP. REPLACED BATTERY PACK.
- 26 Aug 1998
Battery Pack, discharged
FIRST CLASS CEILING EMERGENCY LIGHT OUT. REPLACED BATTERY PACK.
- 23 Aug 1998
Bypass Light, illuminated
NR 3 ENG FILTER BYPASS LIGHT ILLUM. ENG WAS SHUTDOWN. ENG WINDMILLED FOR REST OF FLT. REMOVED AND INSPECTED NR 3 OIL FILTER, NO MATERIAL IN FILTER. CHIP…
- 17 Apr 1998
Stiffener, cracked
FOUND ON A1 LETTER CK, 2 SPAR STIFFENERS CRACKED AT NR 7 SLAT INBD AND OUTBD STIFFENERS AT THE OUTBD TRACK. REPLACED STIFFENERS PER MM 57-20-21.
- 17 Apr 1998
Aux Spar, chafed
FOUND ON A1 LTR CHECK, MLG CHAFING FWD SURFACE OF AUX SPAR I/B END. REPAIRED PER M/M 57-43-0.
- 17 Apr 1998
Rib, cracked
FOUND ON A1 LTR CHECK, NR 4 SLAT NOSE RIB CRACKED 1.5 INCH O/B SIDE OF ACTUATOR ROD END. REPAIRED PER M/M 57-54-0.
- 17 Apr 1998
Fitting, cracked
FOUND ON A1 LETTER CK, UPPER FLANGE OF LT INBD TENSION TIE FITTING CRACKED. REPLACED FITTING PER BOEING DWG NR 65-17509 REV M.
- 2 Nov 1997
Line, failed
HYD LINE TO NR 5 SPOILER CRACKED. CRACK IS OUTBD OF T-FITTING AND BENDS. LOST B-SYSTEM HYD FLUID. EMERGENCY EQUIPMENT CALLED OUT.
- 8 Sep 1997
Web, cracked
VERT WEB ABOVE S-DUCT AT STA 1303 HAS 2 INCH CRACKS AT LT SIDE ONE AT LWR CORNER AND ONE APPROX SIX INCHES ABOVE LWR CORNER. VERT WEB ABOVE S-DUCT AT STA 1303…
- 26 Mar 1997
Door Frame, cracked
DURING INSPECTION, FOUND TWO CRACKS AT THE LT OVERWING EXIT FRAME AT STATION 783.95. REPAIRED PER S/B 727-53-0197 REV 2 (DELTA EO 4-61904-3AD).
- 13 Mar 1997
Floorbeam, corroded
AT MIDVISIT, THE FLOORBEAM AT STA 344 WAS FOUND TO BE CORRODED. CORR WAS REMOVED PER SRM 51-10-6 OUT OF LIMITS. REMOVED FLOORBEAM FROM SPLICE TO O/B WALL LT…
- 13 Mar 1997
Floorbeam, corroded
FOUND FLOORBEAM CORRODED AROUND SCREW HOLES 2BL, 30 TO SIDEWALL STA 344. REPAIRED CHORD PER SRM 53-10-8 FIG 11.
- 4 Feb 1997
Fitting, chafed
FOUND ON F1 LETTER CK, MLG CHAFING FWD SIDE OF AUX SPAR. REPAIRED PER MM 57-43-0.
- 4 Feb 1997
Stiffener, cracked
FOUND DURING F-1 LETTER CHECK, I/B SPAR STIFFENER CRACKED AT NR 3 L/E SLAT O/B TRACK. REPAIRED PER M/M 57-20-21.
- 23 Jul 1996
Light, inoperative
FOUND BOTH EMERGENCY EXIT LIGHTS IN AFT AIRSTAIR INOPERATIVE. CLEANED BATTERY TERMINALS, OPS CK OK.
- 16 Jul 1996
Skin, gouged
DEEP GOUGE IN LWR SKIN BY LINE UP SPADE. REPAIRED PER SRM 57-50-3.
- 21 May 1996
Light, inoperative
EMERGENCY EXIT LIGHT OVER BOTTOM STEP OF AIRSTAIRS INOP. REPLACED BATTERIES AND BULB, NO HELP. REPLACED LIGHT ASSY, OPN NORMAL.
- 21 Jan 1996
Battery Pack, discharged
ON L/O CHECK, FOUND EMERGENCY LIGHTS OUT FROM ROW 27 AFT TO F/A SEAT. REPLACED BATTERY PACK M9027 AND OPS CHECKS NORMAL.
- 8 Dec 1995
Stiffener, cracked
FRONT SPAR STIFFENER, NOSE RIB ATTACH BRACKET CRACKED BETWEEN TWO LOWER FASTENERS AT NR 7 SLAT INBOARD TRACK AT APPROX IWS 588. REPLACED STIFFENER PER MM…
- 25 May 1995
Skin, cracked
FOUND DURING D-2 LETTER CHECK - 1 INCH CRACK AT SKIN WHERE NR 4 JACKSCREW FAIRING BUTTS. REPAIRED PER SRM 53-50-3 FIG 2.
- 25 May 1995
Le Skin, damaged
FOUND DURING D-2 LETTER CHECK - NR 3 T/E FOREFLAP LEADING EDGE SKIN DAMAGED. REPAIRED PER SRM 57-50-4 FIG 1.
- 6 Feb 1995
Rib, cracked
DURING SHOP INSPECTION, FOUND LEFT WING NR 3 SLAT WITH THE LOWER CHORD DAMAGED OUBOARD OF THE INBOARD UP STOP FITTING AND RIB NR 10 CRACKED AT ITS LOWER END,…