N468AA
2026 Costruzioni Aeronautiche Tecna P2010 standard FAA →
registration
- 2026
earlier registrations
1 past record
- 1988
service difficulty reports
60 reports
- 17 Apr 2016
Ballast, overheated
AIRCRAFT WAS GNDED. ACRID SMELL REPORT IN AFT CABIN ACCOMPANIED BY SMOKE COMING OUT OF LIGHTING FIXTURE. EXACT FIXTURE NOT KNOWN. R & R THE UPPER SIDEWALL…
- 2 Nov 2015
Water Separator, odor
SHORTLY AFTER TAKEOFF ROTATION, THERE WAS A FAINT, SHORT DURATION, APPROX 1 MINUTE, ODOR, EITHER A BURNING RUBBER OR OIL RESIDUE ODOR. NO SMOKE, JUST SMELL OR…
- 2 Nov 2015
Water Separator, odor
SHORTLY AFTER TAKEOFF ROTATION, THERE WAS A FAINT, SHORT DURATION, APPROX 1 MINUTE, ODOR, EITHER A BURNING RUBBER OR OIL RESIDUE ODOR. NO SMOKE, JUST SMELL OR…
- 2 Nov 2015
Regulator Valve, odor
SHORTLY AFTER TAKEOFF ROTATION, THERE WAS A FAINT, SHORT DURATION, APPROX 1 MINUTE, ODOR, EITHER A BURNING RUBBER OR OIL RESIDUE ODOR. NO SMOKE, JUST SMELL OR…
- 2 Nov 2015
Regulator Valve, odor
SHORTLY AFTER TAKEOFF ROTATION, THERE WAS A FAINT SHORT DURATION, APPROX 1 MINUTE, ODOR, EITHER A BURNING RUBBER OR OIL RESIDUE ODOR. NO SMOKE, JUST SMELL OR…
- 18 Jun 2015
Clamp, leaking
AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS OVERWEIGHT. DURING CLIMB, PACK TRIPPED OFF & THE TAIL COMPARTMENT TEMP HIGH LIGHT ILLUMINATED.…
- 17 May 2015
Slide, unsecure
AT GATE AS 1L DOOR WAS OPENED, UPON ARRIVAL, SLIDE FELL OUT OF HOUSING. REINSTALLED 1L DOOR SLIDE IAW MM 25-62-00.
- 24 Jan 2015
Skin, damaged
RIGHT ELEVATOR STATIC WICK SHOWS EVIDENCE OF LIGHTNING STRIKE DAMAGE TO UPPER AFT OTBD SKIN. REPAIRED AREA IAW FEA.
- 23 Nov 2014
Switching Unit, defective
AIR INTERRUPT, RETURNED & EMER DECLARED. LANDING UNEVENTFUL, NOT OVERWEIGHT. DURING CLIMB THE NLG RED LIGHT REMAINED LIT WITH AUTO SPOILER DO NOT USE & STALL…
- 22 Sep 2014
Band, damaged
DORSAL FIN BAND AT STATION 52.267 HOLES OUT OF ROUND. REPLACED 503 BAND IAW SRM 55-03-00.
- 19 Sep 2014
Skin, damaged
DAMAGED FASTENER HOLE IN SKIN AT STATION 151 & STRINGER 26 LT. INSTALLED SLEEVE BUSHING IN SKIN.
- 19 Sep 2014
Skin, damaged
DAMAGED HOLE IN SKIN AT STATION 160 & STRINGER 26 LT. INSTALLED SLEEVE BUSHING IN SKIN.
- 15 Sep 2014
Skin, worn
VERTICAL STABILIZER LE JUST BELOW ZFS 52 HAS WORN HOLES. INSTALLED PLUG IAW EA MD80-55-036666.
- 15 Sep 2014
Skin, worn
LEADING EDGE OF VERTICAL BELOW ZFS 52.267 WORN. ACCOMPLISHED NESTED ANGLE REPAIR IAW SRM 55-03-00 FIGURE 29.
- 12 Sep 2014
Structure, worn
FOUND WEAR IN VERTICAL STABILIZER DORSAL FASTENER HOLES. INSTALLED REPAIR DOUBLER IAW SRM 55-03-00-001.
- 12 Sep 2014
Skin Panel, worn
FOUND WEAR IN FASTENER HOLES ON VERTICAL STABILIZER LE PANEL. INSTALLED REPAIR DOUBLER ON VERTICAL STABILIZER LE PANEL IAW SRM 55-03-00-001.
- 10 Sep 2014
Longeron, cracked
LONGERON 26 LT AT STATION 160 CRACKED. INSTALLED SPLICE REPAIR IAW SRM 53-02-00-001.
- 10 Sep 2014
Longeron, cracked
LONGERON 23 LT AT STATION 200 CRACKED. ACCOMPLISHED SPLICE REPAIR IAW SRM 53-02-00-001.
- 10 Sep 2014
Longeron, cracked
LONGERON 24 LT AT STATION 200 CRACKED. ACCOMPLISHED SPLICE REPAIR IAW SRM 53-02-00-001.
- 9 Sep 2014
Longeron, cracked
LONGERON 25 CRACKED AT STATION 160. ACCOMPLISHED REPAIR IAW SRM 53-02-00.
- 21 Apr 2013
Battery Pack, not seated
CEILING EMERGENCY LIGHTS FROM ROWS 7 TO ROW 11 INOPERATIVE. RESEATED BATTERY PACK FOR CEILING EMERGENCY LIGHTS FROM ROWS 7 TO 11. OPS CHECK NORMAL.
- 21 Apr 2013
Battery Pack, not seated
TAIL COMPARTMENT EMERGENCY LIGHTS ABOVE CATWALK INOPERATIVE. RESEATED BATTERY PACK FOR TAIL COMPARTMENT EMERGENCY LIGHTS ABOVE CATWALK. OPS CHECK NORMAL.
- 15 Jan 2012
Cusp Web, corroded
CUSP FROM STATIONS 145 TO 170 RIGHT BUTTLINE 56 CORRODED. ACCOMPLISHED DOUBLER REPAIR PER AARD 53-20-00-14.
- 12 Jan 2012
Cusp Web, corroded
RIGHT CUSP AT STATION 342 CORRODED. ACCOMPLISHED DOUBLER REPAIR PER AARD 53-20-00-16.
- 11 Jan 2012
Cusp Web, corroded
LEFT CUSP AT STATION 1142 CORRODED. ACCOMPLISHED DOUBLER REPAIR PER AARD 53-20-00-16.
- 11 Jan 2012
Cusp Web, corroded
RIGHT CUSP AT STATION 535 TO 539 CRACKED. ACCOMPLISHED DOUBLER REPAIR PER AARD 53-20-00-16.
- 7 Jan 2012
Bracket, cracked
TOP BRACKET CRACKED ON AFT PRESSURE BULKHEAD STIFFENER, 34 INCHES ABOVE FLOOR AT LEFT OUTBOARD END. INSTALLED ANGLE BRACKET ON AFT BULKHEAD STIFFENER LEFT…
- 6 Jan 2012
Cusp Web, cracked
CARGO AFT CX LT CUSP CRACKED STA 1266. INSTALLED CUSP SHEET AT STA1250-1309 LT SIDE PER AARD 53-20-00-16.
- 5 Jan 2012
Cusp Web, damaged
LEFT CUSP SHEET IS DAMAGED FROM STATIONS 1244 TO 1250. INSTALLED DOUBLER PER AARD 53-20-00-16 AND EA MD80-53-021127.
- 5 Jan 2012
Cusp Web, damaged
CUSP AT STATIONS 1244 TO 1250 DAMAGED. REMOVED DAMAGE AND INSTALLED DOUBLER PER AARD 53-20-00-16.
- 17 Dec 2011
Tie Down, corroded
CORROSION ON G-2 GALLEY AFT INBD FLOOR TIEDOWN FITTING AT STATION 216. INSTALLED UPPER G-2 GALLEY MOUNT PER AARD 51-10-00-5.
- 17 Dec 2011
Membrane, corroded
CORROSION ON SUBFLOOR AT G-2 GALLEY AFT INBD FLOOR TIEDOWN FITTING AT STATION 216. INSTALLED SUB-FLOOR DOUBLER PER AARD 53-20-00-16.
- 17 Dec 2011
Membrane, corroded
CORROSION ON SUBFLOOR UNDER G-1 GALLEY DRAIN PAN. INSTALLED DOUBLER ON SUBFLOOR UNDER G-1 GALLEY DRAIN PAN PER AARD 53-20-00-16.
- 16 Nov 2011
Pan, cracked
CRACK IN LEFT RINGPAN AT UPPER AFT CORNER. REMOVED CRACK AND INSTALLED DOUBLER PER AARD 53-10-00-25.
- 16 Nov 2011
Cusp Web, corroded
LEFT CUSP STATIONS 1088 TO 1091 CORROSION BEYOND LIMITS. REMOVED DAMAGE AND INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.
- 15 Nov 2011
Skin, dented
DENTS IN SKIN AT STATION 256. INSTALLED DOUBLER REPAIR PER BOEING DRAWING SG09530002.
- 18 Jul 2011
Gearbox, failed
BNA - CREW REPORTED NUMBER 2 ENGINE OIL QUANTITY AND OIL PRESSURE LOSS. RIGHT ENGINE SHUTDOWN (SINGLE ENGINE TIME 10 MIN). EMERGENCY DECLARED FLIGHT RETURNED…
- 2 Jun 2011
A/C Pack, dirty
LIT - CREW REPORTED ODOR IN FLIGHT DECK AND CABIN. EMERGENCY DECLARED FLIGHT RETURNED LIT LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. ACCOMPLISHED…
- 21 Jul 2010
Filter, clogged
PHL - ON DESCENT RIGHT ENGINE OIL STRAINER CLOGGED LIGHT ILLUMINATED, IDLE POWER WAS NECESSARY TO KEEP LIGHT OUT. EMERGENCY DECLARED, LANDED PHL WITHOUT…
- 5 Jun 2010
Duct, blown
DFW - CREW REPORTED NUMBER 2 ENGINE FIRE LOOP HAD A FIRE INDICATION FOLLOWED BY WARNING BELL. EMERGENCY DECLARED RETURNED DFW LANDED WITHOUT INCIDENT.…
- 6 Nov 2009
Tire, damaged
INFLIGHT DFW TO MEX. CREW REPORTED SEVERE YAW AT ROTATION. FELT LIKE NOSE GEAR PROBLEM. ALSO CAPTAINS SLIDING WINDOW POSSIBLE CRACK. EMERGENCY DECLARED AND…
- 4 Oct 2009
Battery Pack, discharged
EMERGENCY LIGHTS AT FORWARD GALLEY CEILING INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD GALLEY CEILING LIGHTS.
- 6 Jan 2009
Seal, torn
DFW INFLIGHT RIC TO DFW - CREW REPORTED MODERATE BUMP IN FLIGHT FOLLOWED BY FORWARD ENTRY DOOR NOISE. CABIN ALTITUDE ROSE TO 9500 FEET. DESCENDED TO FL190.…
- 23 Jun 2008
Regulator, malfunctioned
DEN INFLIGHT T1055/23JUN. CREW REPORTED ODOR AND HAZE IN CABIN. RETURNED TO DEN AND LANDED WITHOUT INCIDENT. NO EVIDENCE OF FIRE FOUND. REPLACED RT AIR…
- 28 Mar 2008
Battery Pack, dislodged
LGA - EMERGENCY LIGHTS AT OVERHEAD SEAT ROW 28 TO AFT OF CABIN INOPERATIVE. RESEATED BATTERY PACK FOR EMERGENCY LIGHT AT OVERHEAD SEAT ROW 28 TO AFT OF CABIN.…
- 28 Mar 2008
Lamp, inoperative
LGA - EMERGENCY LIGHT AT TAIL COMPARTMENT INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT TAIL COMPARTMENT. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 28 May 2007
Battery Pack, inoperative
LGA - EMERGENCY LIGHT AT FIRST CLASS SECTION INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT FIRST CLASS SECTION. SYSTEM GROUND CHECKED NORMAL…
- 16 Feb 2007
Seal, dirty
ORD INFLIGHT T1349/16FEB - CREW UNABLE TO RETRACT LANDING GEAR. RETURNED TO ORD AND LANDED WITHOUT INCIDENT. CLEANED AND REPLACED SEALS, BEARING PLATE, AND…
- 16 Feb 2007
Strut, leaking
ORD INFLIGHT - UNABLE TO RETRACT LANDING GEAR. THREE GREEN INDICATION AT ALL TIMES. GEAR HANDLE WOULD NOT MOVE FULL RANGE. LANDED ORD WITHOUT INCIDENT. FOUND…
- 17 Mar 2004
Module, inoperative
DFW - SEAT MOUNTED EMERGENCY LIGHT IN FORWARD SECTION ARE DIM. REPLACED NUMBER ONE CONTROL MODULE AND BATTERY AND REPLACED NUMBER TWO BATTERY FOR SEAT MOUNTED…
- 30 Jan 2004
Battery Pack, inoperative
TPA - EMERGENCY EXIT PATH LIGHTS AT ROWS 4 THROUGH 19 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY EXIT PATH LIGHT AT ROWS 4 THROUGH 19. SYSTEM GROUND…
- 30 Jan 2004
Battery Pack, inoperative
TPA - CEILING EMERGENCY EXIT LIGHTS AT ROW 19 AND 20 INOPERATIVE. REPLACED BATTERY PACK FOR CEILING EMERGENCY EXIT LIGHTS AT ROW 19 AND 20. SYSTEM GROUND…
- 19 Apr 2001
Controller, defective
TUL - FLT 1704 - EN ROUTE ORD-EWR, AT 33,000 FEET, CREW REPORTED DROP IN ALTITUDE TO 10,000 FEET. DEPLOYED OXYGEN MASKS, AND LANDED EWR WITHOUT FURTHER…
- 16 Apr 2001
Coalescer Bag, dirty
ORD - FLT 1326 - EN ROUTE ORD-TPA - SHORTLY AFTER TAKEOFF, CABIN FILLED WITH SMOKE. RETURNED ORD AND LANDED WITHOUT INCIDENT. REPLACED COALESCER BAGS.…
- 15 Mar 2001
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT ROW 9 INOPERTIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT ROW 9. SYSTEM GROUND CHECKED NORMAL…
- 3 Nov 2000
Pump, defective
ORD - FLT 792 - EN ROUTE ORD-EWR - DURING INSPECTION, BEFORE FLIGHT, CO-PILOT DETECTED SMOKE IN WHEEL WELL AREA. REPLACED AUXILIARY ELECTRIC HYDRAUIC PUMP.…
- 1 Jan 1999
Wire, chafed
DFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS IN FIRST CLASS WERE INOPERATIVE. REPAIRED EMERGENCY FLOOR PATH LIGHTING WIRE AT SEAT ROW 3DEF.…
- 8 Mar 1997
Air Distribution, odor
DFW - FLT 1284 - DURING APPROACH TO DFW, BURNING ODOR NOTED IN AFT CABIN AND RT LAVATORY SMOKE DETECTOR SOUNDED SEVERAL TIMES. ODOR DISSIPATED AND DETECTOR…
- 28 Feb 1996
Coalescer, dirty
DFW - FLT T1341 - AFTER TAKEOFF MEM DURING INITIAL CLIMB-OUT, SLIGHT ODOR NOTED IN COCKPIT AND CABIN. ODOR DISSIPATED AFTER 10 MINUTES OF FLIGHT AND AIRCRAFT…
- 11 Dec 1995
Csd, defective
OAK - FLT 1769 - DURING CRUISE, THE LEFT ENGINE FIRE WARNING CAME ON. LEFT THROTTLE WAS RETARDED AND FIRE WARNING EXTINGUISHED. LANDED OAK WITHOUT INCIDENT.…